Post by pouyavakili on Execute Codesys Tests with python CODESYS Forge talk (Post)
❓ Issue: TestManager Not Available in Python Script (AttributeError) 🙏 Question: Why does project.get_testmanager() not work in scripting, even though Test Manager is installed and licensed, and the script runs in GUI mode? Is there a way to ensure the Test Manager interface is loaded or accessible from the scripting environment? 🧠 Summary: I'm trying to automate test execution using the CODESYS scripting engine (Python) via a script that opens a project, builds the application, and runs tests from a TestRepository.xml. Although the Test Manager works manually in the IDE, it fails when accessed via script with the following error: AttributeError: 'ScriptObject' object has no attribute 'testmanager' 🧪 Test Setup: CODESYS version: 3.5.21.10 Test Manager: Installed and licensed (works in the IDE manually) Project: Contains a test repository, which can be executed via the GUI Script execution method: powershell Start-Process -FilePath "C:\Program Files\CODESYS 3.5.21.10\CODESYS\Common\CODESYS.exe" ` -ArgumentList @( '--profile="CODESYS V3.5 SP21 Patch 1"', '--runscript="C:\Scripts\run_tests.py"' ) -Wait 📜 Script Summary: python project = projects.open(project_path) application = project.active_application application.build() This fails: testmanager = project.get_testmanager() ❗ Problem: Calling project.get_testmanager() or application.testmanager throws an AttributeError, even though the same project and test repository work in the GUI.
Last updated: 2025-07-23

Post by ph0010421 on How to create a stopwatch? CODESYS Forge talk (Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08

Post by aseitzinger on CODESYS Control for Linux SL on virtual machine? CODESYS Forge talk (Post)
Hello, there in different information available regarding the possibility to run CODESYS Control for Linux SL on a virtual machine. https://forge.codesys.com/trg/linux-sl/home/Home/ says CODESYS Control for Linux SL is a runtime system, which can run on any Debian based X86 PC, VM or Cloud container... https://store.codesys.com/media/n98_media_assets/files/2302000005/3/CODESYS%20Control%20for%20Linux%20SL_de.pdf says CODESYS Control for Linux SL can not be used on virtual hardware Currently I run the package mentioned on a virtualized debian machine running in PROXMOX Virtual Environment 7.4-17 and apart from huge jitter it runs without problems. The CODESYS key is passed as a USB defice to the VM. I wonder why there are different statements regarding the suitability in virtual machines and if the jitter would be reduced by installing CODESYS runtime on the host installing CDS runtime on the host and using a preemptive kernel (if available for the PROXMOX installation leaving CDS runtime where it is (on the virtualized debian machine) and install a preemptive kernel on the host and on the guest... Any advice is appreciated. Greets Arno
Last updated: 2024-01-08

Post by anlebr on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi I am trying use the Codesys Communication Manager to set up an Opc ua server with a custom information model. As a start I am using the Boiler model available on Opc foundations github page. I am testing with a Wago CC100 and using Codesys V3.5 SP19 Patch 6. I get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://opcfoundation.org/UA/Boiler/ with a minimal publication date from 15/12/2023 but the device has only a model from 15/09/2021 installed. Probably the information model from 15/09/2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway, both versions are available in the repository. How can I solve this?
Last updated: 2024-03-13

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
System Information from the computer being used: OS Name Microsoft Windows 11 Pro Version 10.0.22631 Build 22631 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Manufacturer Dell Inc. System Model Latitude 5500 System Type x64-based PC System SKU 08B9 Processor Intel(R) Core(TM) i7-8665U CPU @ 1.90GHz, 2112 Mhz, 4 Core(s), 8 Logical Processor(s) BIOS Version/Date Dell Inc. 1.3.11, 6/11/2019 SMBIOS Version 3.2 Embedded Controller Version 255.255 BIOS Mode UEFI BaseBoard Manufacturer Dell Inc. BaseBoard Product 0M14W7 BaseBoard Version A00 Platform Role Mobile Secure Boot State On PCR7 Configuration Elevation Required to View Windows Directory C:\WINDOWS System Directory C:\WINDOWS\system32 Boot Device \Device\HarddiskVolume1 Locale United States Hardware Abstraction Layer Version = "10.0.22621.2506" User Name CARDASSIA-IX\Engineer Time Zone Eastern Daylight Time Installed Physical Memory (RAM) 16.0 GB Total Physical Memory 15.8 GB Available Physical Memory 4.67 GB Total Virtual Memory 18.5 GB Available Virtual Memory 2.52 GB Page File Space 2.63 GB Page File C:\pagefile.sys Kernel DMA Protection Off Virtualization-based security Not enabled Windows Defender Application Control policy Enforced Windows Defender Application Control user mode policy Off Device Encryption Support Elevation Required to View Hyper-V - VM Monitor Mode Extensions Yes Hyper-V - Second Level Address Translation Extensions Yes Hyper-V - Virtualization Enabled in Firmware Yes Hyper-V - Data Execution Protection Yes
Last updated: 2024-03-19

Post by caprez95 on Trace Restart Visuelement CODESYS Forge talk (Post)
Hello everyone. I've been struggling with the problem for a long time that I can't reset (restart) a trend (visual element). With the example I have now managed to control the trace recording via the CmpTraceMgr library. But how do I get this trace recording into a visual element? The code looks like this: // Configure trace IF xInit THEN // Create a trace packet PacketConfig.pszName := ADR('IECTraceConfiguration.Trace1'); // Name of trace PacketConfig.pszApplicationName := ADR('IECTraceConfiguration'); // Name of the application PacketConfig.pszIecTaskName := ADR('Task'); // Name of the task PacketConfig.pszComment := ADR('Demo packet'); PacketConfig.ulEveryNCycles := 1; PacketConfig.ulBufferEntries := 1000; PacketConfig.ulFlags := TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_TIMESTAMP_MS AND TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_AUTOSTART; IF (NOT fbTraceManager.CreatePacket(PacketConfig := PacketConfig, hPacket=>hPacket1)) THEN xError := TRUE; END_IF // Create a trace record RecordConfig.pszVariable := ADR('iSignal'); // This is the name of variable to record RecordConfig.tcClass := INT_TO_UDINT(TypeClass.TYPE_INT); // Type of the recording variable RecordConfig.ulSize := SIZEOF(iSignal); // Size of the recording variable pApp := AppFindApplicationByName('IECTraceConfiguration', 0); AppGetAreaOffsetByAddress(pApp, ADR(iSignal), ADR(RecordConfig.tvaAddress.taAddress.Area.usArea), ADR(RecordConfig.tvaAddress.taAddress.Area.ulOffset)); // Get and set area offsets RecordConfig.tvaAddress.ulAddressFlags := TRACE_VAR_ADDRESS_FLAGS_IEC OR TRACE_VAR_ADDRESS_FLAGS_AREA_OFFSET; RecordConfig.ulGraphColor := 16#FF00FF00; // green RecordConfig.ulGraphType := 1; // Line with points IF (NOT fbTraceManager.AddRecord(RecordConfig := RecordConfig, hPacket := hPacket1, hRecord => hRecord1)) THEN xError := TRUE; END_IF xInit := FALSE; END_IF // Starts the recording IF xStart THEN IF (NOT fbTraceManager.StartPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStart := FALSE; END_IF // Stop the recording IF xStop THEN IF (NOT fbTraceManager.StopPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStop := FALSE; END_IF // Reset the recording IF xReset THEN IF (NOT fbTraceManager.ResetPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xReset := FALSE; END_IF
Last updated: 2024-06-04

Post by caprez95 on Deleting the trend recording history CODESYS Forge talk (Post)
Hallo Ich möchte eine laufende Trendaufzeichnung stoppen, den Inhalt löschen und Trend-Diagramm auf 0 zurücksetzen. Laut Codesys soll das mit dem folgenden Code möglich sein: You can insert an input element in the visualization which the operator can use to delete the previous value recording in the trend visualization at runtime. The curve displayed until then is removed and the display starts over. In the application (example: in the program PLC_PRG), implement the following code: itfTrendRecording : ITrendRecording; itfTrendStorageWriter : ITrendStorageWriter; itfTrendStorageWriter3 : ITrendStorageWriter3; sTrendRecordingName : STRING := 'TrendRecording'; itfTrendRecording := GlobalInstances.g_TrendRecordingManager.FindTrendRecording(ADR(sTrendRecordingName)); xClearHistoryTrend: BOOL; IF xClearHistoryTrend THEN itfTrendRecording := GlobalInstances.g_TrendRecordingManager.FindTrendRecording(ADR(sTrendRecordingName)); IF itfTrendRecording <> 0 THEN itfTrendStorageWriter := itfTrendRecording.GetTrendStorageWriter(); IF __QUERYINTERFACE(itfTrendStorageWriter, itfTrendStorageWriter3) THEN itfTrendStorageWriter3.ClearHistory(); END_IF END_IF In the visualization of the trend recording, add a button for deleting the previous curve. Configure its Toggle property with the variable PLC_PRG.xClearHistoryTrend. ⇒ When xClearHistoryTrend is set to TRUE, the previously recorded curve is deleted. The recording immediately starts again. Dies löscht auch die Daten vom Trend, aber das Diagramm wird nicht auf 0 zurückgesetzt, sondern läuft einfach da weiter wo man gestoppt hat. Braucht es für den Diagramm-Reset noch einen zusätzlichen Befehl? Gruss
Last updated: 2024-06-11

Post by clarenced on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks CODESYS Forge talk (Post)
Using codesys v3.5 SP21 Patch 1. We are using Visualization to display alarms. Other then the automatically created AlarmManagerTask, there is no code written to call AlarmStorage_Prg. Any ideas why we would be seeing this error in the log? The runtime actually shutdown. Not sure if that was caused by this error or not. 2025-08-03T02:45:35.444Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T03:48:15.294Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T04:38:11.557Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * 2025-08-03T04:38:11.576Z, 0x0000010f, 8, 1, 0, #### Exception: SysSemEnter - Semaphore deadlock detected - owner thread died [tid:726740] - system may be in an inconsistent state. 2025-08-03T04:38:11.576Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-08-03T04:38:11.576Z, 0x00000001, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-08-03T04:40:12.308Z, 0x00000001, 1, 0, 35, CODESYS Control shutdown... 2025-08-03T04:40:13.436Z, 0x00000071, 1, 0, 13, Webserver stopped 2025-08-03T04:40:13.437Z, 0x00000114, 2, 1, 0, !!!! Warning: task_signalhandler_exit [MainTask] lost cycles: 14809 2025-08-03T04:40:13.497Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IecVarAccess</cmp>, <id>0x00001007</id> <ver>3.5.3.64</ver> 2025-08-03T04:40:13.506Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>AlarmMgr</cmp>, <id>0x00001012</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.513Z, 0x00000071, 2, 0, 14, !!!! Warning: Unbalanced calls to WebServerRequestRunning/WebServerReleaseRunning 2025-08-03T04:40:13.513Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IECVisualization</cmp>, <id>0x0000100c</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:50:17.708Z, 0x00000001, 1, 0, 36, CODESYS Control shutdown done
Last updated: 2025-08-04

Post by madskaizer on Task Priority Documentation? CODESYS Forge talk (Post)
Hi All I was watching the Wago PFC300 webinar ( https://www.wago.com/global/lp-thank-you-onlineseminar-pfc-300 ), and the presenters comment about priority 1 being way above the Ethernet task priority, so that a priority 1 PLC program can actually loose SCADA connection, made me try to round up some hard evidence on Codesys Priorities. I find there is very little information on "correct" task priority configuration. There is a lot of different hardware manufacturers, using Codesys Runtime, that has different descriptions in their manuals on how to set up priority. https://doku.amk-motion.com/en/Subsystems/PDK_202975_A-Serie_en/Content/Projekt/AMKAMAC/PDK_202975_A4-A5_Produktbeschreibung/Funktionalitaet/PLC-Programming/PLC%20Tasks.htm?TocPath=PLC-Programming%7C_____7 https://product-help.schneider-electric.com/Machine%20Expert/V1.1/en/SoMProg/index.htm?#t=SoMProg%2FTask_Editor%2FTask_Editor-7.htm&rhsearch=priority&rhhlterm=priority&rhsyns=%20&SUBSTRSRCH=1 https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_f_task_configuration.html So my questions :) 1) If there is only 1 PLC_PRG task, does priority matter? 2) What is the priority of Ethernet / communication, if nothing is entered? 3) What is the priority of Codesys OPC UA server? 4) Some users here on forge mentions that Wago PLC programs should run as priority 11, but where does this recommendation origin from? 5) What are you recommendations for a relatively slow process, like building automation? It uses OPC UA for communication to SCADA, maybe some MODBUS-RTU and MODBUS-TCP, usually around 100 I/O, been running with everything in a single task at priority 1, 50-100ms cycle time. Some controllers have separate MODBUS tasks, but doesn't seem like a big difference. How would you recommend splitting up communication, IO fieldbus and programs into differently prioritized tasks? I know its a complex matter and all about my application, but I really miss there was just some kind of guidance in the documentations and with all new standard Codesys programs having priority 1 as default, makes it seem less important, than it really is.
Last updated: 2025-08-11

Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-20

Post by jickisticki on Witch library? CODESYS Forge talk (Post)
Crafting my Fellowship Personal Statement was like weaving the threads of my aspirations into a tapestry of words. Each sentence became a brushstroke, painting a vivid portrait of my journey and ambitions. Beyond being just a document, it became a mirror reflecting the depth of my experiences. Like a conductor guiding an orchestra, my personal statement was composed to resonate with my unique voice. In the realm of specialized opportunities, this statement serves as a compass, guiding me toward the next chapter of my professional growth. With each word, I felt the guidance of mentors shaping my story into an eloquent narrative.
Last updated: 2023-08-17

Post by ellcap on Did a library update and now can't open project CODESYS Forge talk (Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25

Post by matthew on New Ladder Editor Issues CODESYS Forge talk (Post)
Hi There, When using the new ladder editor there is no option for function blocks to Remove uncalled FB call parameters. I also see no update function block. When you double click the function block it no longer opens the function block. I also now get warnings if I insert FB call without a contact in front. Warning is: (Impl)): C0373: Expression or part of it has no effect I take it the new editor must work differently? The only reason for using new ladder editor is the ST execute/block editing is far better, If you have alot of text in the old ST execute the editor window is very small and when online it's even worse. The new ST block seems a lot better Thanks!
Last updated: 2023-10-10

Post by smartcoco on The text list provided outside the library is not available for visualization controls within the library. CODESYS Forge talk (Post)
I have a project called 'DemoProject' and a library called 'DemoLib'. Create a visual control named "DemoVisu" in the library, with a selection box of type "ComboBoxInteger" in the space. Now 'ComboBoxInteger' requires a 'Text list'. This "Text list" is provided when I call the "DemoVisu" control of the "DemoLib" library in "DemoProject". And this text list is in 'DemoProject'. I found that 'ComboBoxInteger' no longer works at this time. Other visual controls that use text lists also have this issue. I hope there is a good solution to this problem.
Last updated: 2023-10-16

Post by dhumphries on install codesys runtime on linux CODESYS Forge talk (Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04

Post by appling on License status of Linux 64Bit runtime via CLI CODESYS Forge talk (Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04

Post by opineiro on Stack overflow with really simple function CODESYS Forge talk (Post)
Hi, I have an issue with a function which sends a message through API Rest. I'm using a function from httpCLient library. I have tested this function inside a program and it works fine. But when I want to use it inside a function (so I can call it simultaneously from 2 different points on the main program) it gives a stack overflow error. In detail it says: "C0297 Stack Overflow on Main Task. Stack sizes... Call hierarchy:" I have simplified as much as I can the function, but I'm hitting a wall with this. Anybody has an idea of what's wrong? Thanks!
Last updated: 2024-09-16

Post by rmaas on TargetVisu for Linux SL not starting CODESYS Forge talk (Post)
Hello, I am trying to get TargetVisu for Linux working but i am having some troubles. The problem is that after installation it is not starting automatically on boot and i cannot start it from the update Targetvisu tool. When i try i get the following error (see attached screenshot) The file /opt/codesysvisualization/scripts/codesysvisualization_start.sh is missing... Steps performed: - installed fresh Debian 12.7 on virtual machine - installed all required libraries as described here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html - then installed the TargetVisu for Linux SL 4.13.0.0 using the Codesys IDE Does someone know how i can fix this? Best Regards, Rinie
Last updated: 2024-10-02

Post by pistola on Case Function - Multiple Conditions, Is it possible? CODESYS Forge talk (Post)
Looking at the help (https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_st_instruction_case.html). I don't think it is possible but I figured I'd ask. I'm looking at have a case that evaluates two variables, instead of having multiple If Else statements I was hoping I could just use a case. Example * Case Var1 & Var 2 of 10 & 10: Instruction Code 10 & 20: Instruction Code 20 & 20: Instruction Code End_Case Obviously I tried typing as noted above and Codesys threw an error. But I was wondering if there was a different way of programming to make something like this work? If not I'll just use a bunch of If Else Statements, Thanks.
Last updated: 2024-11-03

Post by pistola on Error during Updating the Visualisation CODESYS Forge talk (Post)
I've got a visualization I'm working on with some rectangles and lines. When I simulate the program I get an Error and Message in my message box, "Error during Updating the Visualisation:" and "Overflow error." Any ideas on how to fix this? I only have 70 elements total for this visualization. I am using absolute movement for a few of the elements, would this cause the issue? The visualization seemed fine before I added these movement elements, but there is only 7 that move, that doesn't seem like it should over load the system. I am currently testing using simulation so I'm not sure if that has an effect either. I tried looking in the codesys help manual and couldn't find anything referencing this.
Last updated: 2024-11-19

Post by gseidel on Beckhoff AS1060 and EL7041 configuration CODESYS Forge talk (Post)
Hi pmanuele, while I don't have firsthand experience with the EL7041 and the step motor AS1060, there are two things you can check: If you use an external encoder, please make sure you use the alternative device description calles "EL7041 1Ch. Stepper motor output stage (50V, 5A) Rev24 with external Encoder". The SoftMotion driver will set the feedback type automatically, and use the correct object for the actual position (16#6010:21 instead of 16#6010:20) If you have problems with changing the controller mode, I assume to velocity, please make sure you change the PDO mapping so that the actual velocity (16#6020:33) and set velocity (16#7010:33) are mapped by PDO. Hope this helps, Georg
Last updated: 2024-12-23

Post by trusty-squire on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hi, Is there a way to read the homed status from the EtherCAT drive directly? I am currently flagging the homed status on the succesful completion of the MC_Home function block, but I have had false triggers where the drive didn't actually execute the homing procedure but the MC_Home FB is marked as complete without error. I looked at other MC/SMC function blocks but the closest I can find is the "Homing" bit from MC_ReadStatus FB, but this doesn't show if the drive is succesfully homed, only that it's homing. Any guidance is welcome. Thanks!
Last updated: 2025-01-07

Post by ton on String nach erlaubten/unerlaubten Zeichen durchsuchen CODESYS Forge talk (Post)
Hi Timo, FUNCTION Sonderzeichen_Check : bool VAR_INPUT sInputString : STRING; // Zu prüfender String END_VAR VAR i: INT; iAsc: INT; END_VAR Sonderzeichen_Check:= TRUE; FOR i:= 0 TO len(sInputString) - 1 DO iAscii:= sInputString[i]; //Get ASCII value //Check value between 48('0') and 65('9') or between 65('A') and 90('Z') or between 97('a') and 122('z') or IF iAscii >= 48 AND iAscii <= 57 OR iAscii >= 65 AND iAscii <= 90 OR iAscii >= 97 AND iAscii <= 122 THEN //iAscii valit ELSE Sonderzeichen_Check:= FALSE; END_IF END_FOR Diese FUNCTION anrufen: VAR xTest1: BOOL; xTest2: BOOL; sCheck: STRING; END_VAR xTest1:= Sonderzeichen_Check(sInputString:= 'abcuharoahse89347KEWDL'); //=TRUE xTest2:= Sonderzeichen_Check(sInputString:= 'abcuharoahse89347KEWDL?'); //=FALSE IF Sonderzeichen_Check(sInputString:= 'CheckThisSting,') THEN sCheck:= 'OK'; ELSE sCheck:= 'NOT OK'; END_IF
Last updated: 2025-01-20

Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue CODESYS Forge talk (Post)
Hello, I noticed that version 0.0.0.6 is now available, so I tested it using CODESYS V3.5 SP19 Patch 7 and SoftMotion 4.17.0.0. While the project compiles and downloads without issues, I encountered a problem with the 'Enable: GPIO pin number that is set when the axis is enabled (with MC_Power) (0: not used)' functionality — it no longer works (HIGH level not present at the output pin). I observed the same behavior with version 0.0.0.5, whereas version 0.0.0.4 functions correctly. Could you help me identify what might be causing this issue or suggest how to resolve it? Thanks.
Last updated: 2025-03-19

Post by beginner on ERROR: Demo mode for SoftMotion Basic expired. Feature stopped! CODESYS Forge talk (Post)
Hello. Please help me. Sometimes SoftMotion starts in demo mode and stops working after 2 hours. When I check with the license manager, it is recognized normally. I checked the log. After changing online or logging in with a download, the message "**** ERROR: Demo mode for SoftMotion Basic started. Will expire and stop!" was left. Even if you change online or log in with a download, this phenomenon may not occur. Please tell me how to solve this problem. Thank you in advance. Codesys Ver 3.5.20.0 SM3 Basic SoftMotion Ver 4.16.0.0 ※This text was translated using a translator.
Last updated: 2025-03-25