Search talk: string to word

 
<< < 1 .. 21 22 23 24 25 .. 226 > >> (Page 23 of 226)

CODESYSControl_User.cfg - link to documentation? CODESYS Forge talk (Thread)
CODESYSControl_User.cfg - link to documentation?
Last updated: 2024-06-11

Data to server CODESYS Forge talk (Thread)
Data to server
Last updated: 2025-11-11

Post by jami on Reading multiple lines from csv file CODESYS Forge talk (Post)
Hello, i am trying to read multiple lines from csv file with caa file library and oscat. I have wrote 7 lines in the csv with separation '$R$L'. In my "extracting values" part I check line feeds and chars. After that I convert my buffer to string with oscat but I'm only able to read the first line from the csv. No matter if I even change start position where I start converting the buffer, I only get the first line. Here's my code for the reading and extracting value parts: 4: (*Reading the file*) fileread.hFile := filehandle; fileread.pBuffer := ADR(buffer); filesize1:=SIZEOF (buffer); fileread.szbuffer:=filesize1; fileread.udiTimeOut := 100000; fileread(xExecute := TRUE); IF fileRead.xDone THEN iFilesize:=TO_INT(fileread.szSize); writestate:=3; fileRead.xExecute := FALSE; END_IF 5: (*Extracting values*) //here i check the number of line feeds and chars. It works WHILE i < ifilesize DO c:=buffer[i]; IF c= 10 THEN IF lineindex<=99 THEN lineIndex := lineIndex + 1; END_IF ELSIF c <> 13 THEN IF charIndex <= 1000 THEN charIndex := charIndex + 1; END_IF END_IF i := i + 1; END_WHILE // Here i convert the buffer to string and transfer it to filelines:ARRAY[0..99] of string[254]. trig(CLK:=BUTTON); IF trig.Q THEN fileLines[i2]:=oscat_basic.BUFFER_TO_STRING(PT:=ADR(buffer), Size:=TO_UINT(fileread.szBuffer), start:=TO_UINT(bufferStart), stop:=TO_UINT(filesize1)); i2:=i2+1; bufferstart:=bufferstart+80; END_IF If anyone has idea how to read multiple lines, it would be nice. Even if you have example codes that work, that would help a lot.
Last updated: 2025-07-18

Post by taqamert on Codesys 2.3 & Peak PCAN CODESYS Forge talk (Post)
Despite working on it for days, I haven't achieved any results. I followed the necessary steps one by one as mentioned in the file you sent, but there hasn't been the slightest change. I couldn't find the step you mentioned "Set the 'Can Board Type' to PCAN USB" in the Word document. There is no such setting anywhere I looked. Is there a more detailed explanation available, or can you explain it in more detail? What am I missing?
Last updated: 2024-07-16

Post by gseidel on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
Hi jonasz, you already solved it, I'm answering here for the sake of others with a similar question. You can provide the slope of the A/B/C axis with the U/V/W word. See example 3 here: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cnc_din66025_additional_axis.html If you don't want to change the G-Code, the function block SMC_RecomputeABCSlopes can compute the slopes automatically. https://content.helpme-codesys.com/en/libs/SM3_CNC/Current/SM_CNC_POUs/SoftMotion-CNC/SoftMotion-Function-Blocks/SMC_RecomputeABCSlopes.html Best regards, Georg
Last updated: 2024-04-30

Post by risele on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
You are welcome. Also note, that it's valid only if you modbus-device use same real/float value representation (IEEE 754). That's true for most of systems. But some devices may have other representation, such as integer + position of the decimal point, for example 123.456 is integer = 123456 and position = 3 Also note, that, ones again, depending on endianess of each system, you may also need to swap not just words, but bytes. TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; bVal:ARRAY[0..3] OF BYTE; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE than swapping may be something as VAR A,B,C,D:BYTE; //Bytes of the real value uIn, uOut:u_Real; rVal:REAL; ModbusReg1,ModbusReg2:WORD; END_VAR uIn.rVal:=rVal; uOut.A:=uIn.D; uOut.B:=uIn.C; uOut.C:=uIn.B; uOut.D:=uIn.A; ModbusReg1:=uOut.wVal[0]; ModbusReg1:=uOut.wVal[2]; Or you even need to reorder bits... Ones again, sending float/real values is not defined by Modbus protocol itself, so it is hardware- and software-dependent. The Modbus Poll (and most of modbus tools) have configuration parameters that will properly swap bytes on their side. Ones again, that's very helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/
Last updated: 2026-02-19

Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable CODESYS Forge talk (Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29

Post by imdatatas on TO_STRING operator not working for IMPLICIT ENUM CODESYS Forge talk (Post)
Hi Everyone, It is a very useful feature to be able to obtain the enum value as a string with the TO_STRING operator by defining {attribute 'to_string'}. However, unfortunately the same function does not work for IMPLICIT ENUMs. I hope that {attribute 'to_string'} behavior can also work for Implicit Enumeration data types in one of the upcoming Codesys versions. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_to_string.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_implicit_enumeration.html Best regards, Imdat
Last updated: 2025-03-27

Post by yannickasselin on How to sort JSON object in codesys CODESYS Forge talk (Post)
Just adding: sSubscriberdata := ''; Right before your memcopy should fix the extra characters. It is because your are copying 36 characters into a string which can contain more than 36 characters and there is garbage left in the extra characters. Regarding the parsing of json, I usually build a structure that mirrors the json data and use the available methods in the IIoT library to parse the data and fill the structure.
Last updated: 2024-05-08

Post by tba123 on Script engine, git checkout, Project Environment CODESYS Forge talk (Post)
Hi, I clone a git repository with VersionUpdateFlags.SilentMode, works fine But now I want to checkout a specific commit (with branch_copy command). When using the branch_copy command there is no VersionUpdateFlags and I get this annoying "Project Environment" prompt, blocking further execution of my script without user input. I already tried something like system.prompt_answers[???] = PromptResult.Cancel but I don´t know the string I need here.. The goal is to have a script that clones a repository and compiles every tag + create compiled libraries.
Last updated: 2024-06-10

Post by antonz on CoDeSys v3.5: creating libraries for both 32-bit and 64-bit controllers CODESYS Forge talk (Post)
Looking for thoughts on creating libraries that can be used on both 32-bit and 64-bit controllers. We are currently writing software in CoDeSys for both target types and will continu to do so for the near future. Projects are always unique, no straight forward copy/paste, yet there is enough similarity between them to use libraries for recurring logic. I do not want to create and maintain twice for both platforms if this is not absolutely necessary. I am aware of useful datatypes like __XWORD, __XINT, __UXINT. Still looking for more information and/or sample code for portable pointer arithmetic. In addition to that: how should one go about when creating and working with compiled libraries? Would I need to compile the same lib twice, once for 32-bit targets once for 64-bit targets? I would end up with two different libs with the same namespace, which does not sound elegant to me. Note: I did not intentionally make the previous paragraph bold. The forge forum software seems to do this automatically upon insertion of a word which starts with two underscores, e.g. __XWORD (yeah, here we go again :) )
Last updated: 2025-08-25

Post by macros8 on Alarm Management - latched variable represented as Text list CODESYS Forge talk (Post)
Hi, I haven´t noticed you put the comment here. I thing it´s a bit different. What I want is to have detail errors of technology in data type e.g. INT. This variable I would latch to the corresponding error msg but I would like to get it convert to text from the text list and not keep it in INT form. Example. Main error Valve Error: SubErrors 1 - Both sensors 2 - Not retracted in time 3 - Not pulled out in time In HMI Main error + latch SubErrors => "Valve Error: Both sensors" The benefit is that text lists are part of translation and can be easily manipulated. I know I can create whole string msg in PLC but then, it lose advantage of Alarm management. Thanks. M.
Last updated: 2023-11-07

Post by ricola on Change default node Id name on Raspberry Pi CODESYS Forge talk (Post)
EDIT : https://forge.codesys.com/forge/talk/Engineering/thread/cb5a492aa0/ hyplcmotion - 2022-12-16 Found out how! Needed to connect to PFC200 via Putty, and open CodesysControl.cfg with “sudo nano /etc/CODESYSControl.cfg”. Then adding following command to the end of file, and use the name you want, save/close CODESYSControl.cfg, and reboot your PLC. [CmpOPCUAProviderIecVarAccess] CustomNodeName= PFC200 Hi! , I'm digging up this issue cause we have still this long name within current versions on CodesysControl. Is it a lock for "demo" licences or can it be changed in some way ? This DeviceSet name is too way long with spaces inside, not easy to handle with string parsing... Cheers !
Last updated: 2024-10-10

Post by timo on String nach erlaubten/unerlaubten Zeichen durchsuchen CODESYS Forge talk (Post)
Hallo, Ich bastele gerade an einer möglichst einfachen Möglichkeit mit der ich prüfen kann ob ein String Sonderzeichen enthält. Mein Ansatz ist ein ST FB mit einer Case Schrittkette. Ich vergleiche jedes Zeichen des Strings mit allen Zeichen eines vorher definierten Strings erlaubter Zeichen, der A-Z, a-z und 0-9 enthält und ggf angepasst werden kann, wenn ich weitere Zeichen erlaube. Leider wird meine j Zählervariable nicht richtig ausgeführt. Hat da jemand eine Idee? Oder gibt es eine einfachere Lösung/einen fertigen FB den ich mir anschauen kann? FUNCTION_BLOCK Sonderzeichen_Check VAR_INPUT inputString : STRING; // Zu prüfender String startCheck : BOOL; // Startsignal END_VAR VAR_OUTPUT ok : BOOL; // TRUE, wenn keine ungültigen Zeichen END_VAR VAR i : INT := 1; // Input-String Zähler j : INT := 1; // erlaubte Zeichen Zähler allowedChars: STRING := 'ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789'; // Erlaubte Zeichen currentChar : STRING[1]; // Aktuelles Zeichen step : INT := 0; // Schritt END_VAR CASE step OF 0: // Warten auf Start IF startCheck THEN step := 10; END_IF 10: // Initialisierungen i := 1; j := 1; ok := TRUE; // Standard: ok step := 20; 20: // Durchgehen des Eingangs-Strings IF i <= LEN(inputString) THEN currentChar := MID(inputString, i, 1); // Aktuelles Zeichen step := 30; ELSE step := 70; // Alle Zeichen ok END_IF 30: // Durchgehen der erlaubten Zeichen IF j <= LEN(allowedChars) THEN step := 40; // Zu Schritt 40 ELSE step := 60; // Ungültiges Zeichen END_IF 40: // Vergleich IF currentChar = MID(allowedChars, j, 1) THEN i := i + 1; // Nächstes Zeichen im Input step := 20; ELSE j := j + 1; // Nächstes erlaubtes Zeichen step := 30; END_IF 60: // Ungültiges Zeichen ok := FALSE; // Setze auf FALSE step := 0; 70: // Alle Zeichen ok step := 0; END_CASE
Last updated: 2025-01-20

Post by risele on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
First, if you don't need to change conversion rules in runtime, take a look at "Unit conversion" module (Application -> add object -> UnitConversion). You can specify there biderectional conversion with different units, limits and so on. Second, since MODBUS don't have "real" types but only general 16-bit registers and Real is 32-bit, generally you need a byte-was conversion Real <> two Words. Note, that depending on the devices on both sides, there are two options: Real-> Word1, Word2 or Real-> Word2, Word1, where Word1 is minor register in Modbus register pair and Word2 is major. You can use simple union: TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE and convert it as following: VAR myUnion:u_Real; rValue_TO_SEND:REAL; rValue_TO_GET:REAL; END_VAR myUnion.rVal:=rValue_TO_SEND; rValue_TO_GET:=myUnion.rVal; Note, that WORD-order should be properly set in MODBUS registers, otherwise you will get strange values. This tool is helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/ Alternative, you can use functions as REAL_TO_DW and DW_TO_REAL from OSCAT_BASIC, for example.
Last updated: 2026-02-19

Post by hanoues on setting date and time on CPX-E CODESYS Forge talk (Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21

Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16

Post by mp9876 on Device logon problem following fresh install CODESYS Forge talk (Post)
All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. ‘Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh install: YES then: Initially went with Administrator twice (user & password) but it did not like it. No device is responding to …: Continued by setting a new user Pressed OK and obtained the following message: Stopped and Restarted PLC at that point: Obtained the following: Attempted to login a 2nd time without success. Then I scanned the network to see if matching device can be detected: Only way to get it detected was to remove the tick in the ‘Hide non-matching devices…’ Attempted a WINK but got a return like this one: REFRESH either @ Users and Groups or @ Access Rights returns: Then created user ‘mp’ at Project level ang logged in: Understandably device user mp9876 was not valid for the Project. Device information A few questions comes to my mind following these connection attempts: 1- Gateway not configured properly message pops out because of a non-compatible device ? 2- Why would the device not be compatible ? 3- Any way to make the device compatible ? 4- Any ideas on how to get this connectivity problem to the device solved ?
Last updated: 2024-03-17

Post by alessandro on SysMemCmp SysMemCpy CODESYS Forge talk (Post)
VAR Data1:ARRAY[1..10] OF SINT ; Data2:ARRAY[1..10] OF SINT ; Data3:ARRAY[1..10] OF SINT ; Data4:ARRAY[1..10] OF SINT ; ex_1 : BOOL ; ex_2 : BOOL ; enable : BOOL :=0 ; END_VAR // PROGRAM // The scope of this example is compare and copy the values of two ARRAY only if some value is different using SysMemCmp and SysMemCpy. // In this 2 example we don't use a FOR cicle for do this, and pBuffer1 and pBuffer2 is just a pointer to ARRAY. See details in Library util.SysMem of Codesys // The compare funcion util.SysMem.SysMemCmp is bidirectional if Data1 chanege respect Data2 ex_1 go to 1 and if Data2 change respect Data1 also // but the copy function util.SysMem.SysMemCpy work only from source ARRAY pSrc:=ADR(Data1) to destination ARRAY pDest:=ADR(Data2) // Example 1 Full ARRAY compare and copy // This compare 2 different equal ARRAY and if there is some difference ex_1 go to 1 and if you give enable he copy Data1 in Data2 ex_1 := TO_BOOL(util.SysMem.SysMemCmp(pBuffer1:=ADR(Data1), pBuffer2:=ADR(Data2), udiCount:=SIZEOF(Data1))); IF ex_1 AND enable THEN util.SysMem.SysMemCpy(pDest:=ADR(Data2), pSrc:=ADR(Data1), udiCount:=SIZEOF(Data1)); END_IF // Example 2 Only selected area of the ARRAY compare and copy // This compare 2 different equal ARRAY starting from position number [3] for 4 byte in this case start at position [3] and finish at position number [6] // and if there is some difference only in area [3..6] of the ARRAY ex_2 go to 1 if you give enalbe he copy Data3[3..6] in Data4[3..6] // if something change in other array position[0..2] or [7..10] are ingnored ex_2 := TO_BOOL(util.SysMem.SysMemCmp(pBuffer1:=ADR(Data3[3]), pBuffer2:=ADR(Data4[3]), udiCount:=4)); IF ex_2 AND enable THEN util.SysMem.SysMemCpy(pDest:=ADR(Data4[3]), pSrc:=ADR(Data3[3]), udiCount:=4); END_IF // Attention udiCount input is intended in <byte> in the example 1 I pass to udiCount:=SIZEOF(Data1) for compare and copy the intere ARRAY and // SIZEOF pass the size of intere ARRAY in byte to the function input, in this 2 examples I used variable type SINT each one occupie 1 byte and one position in the ARRAY // and in the example 2 I pass udiCount:=4 for compare and copy only 4 position of Data3/4[3..6] if you want to extend this example and use it for an ARRAY OF WORD // remember that each WORD will occupe 2 byte (16 bit) and you will have to pass udiCount:=SIZEOF(Data1) if you need to compare intere ARRAY example 1 // but need udiCount:=(42) for the example 2 because need to compare and copy 4 word each occupie 2 byte (16 bit). // For REAL (32 bit) need udiCount:=SIZEOF(44) for LREAL or (64 bit) need udiCount:=SIZEOF(416) // a good rule is calculate the dimension of the ARRAY in byte without empty space at the end, multiple of data type number for variable bigger then 8 bit // Example : If you want to create an ARRAY for 5 REAL (32 bit) each occupie 4 byte the correct size is ARRAY[0..19] OF REAL 54=20 position. // NOTE : In the example the position of compare function util.SysMem.SysMemCmp is first and the copy function util.SysMem.SysMemCpy inside the IF is after // in one cycle of the program the two array is compared and if there is some difference and enable are copied. // If you move util.SysMem.SysMemCmp after the IF cycle he will copare the ARRAY in the current cycle but the copy of the value will do in the next cycle.</byte>
Last updated: 2025-10-24

Post by kut69 on Retain / Persistent Variables in Codesys for Raspberry Pi CODESYS Forge talk (Post)
Hi, I am interested in details about the .ret file in the filesystem. I have already a project where the file is used (write on demand, read by start) and I want to share it as 'default input' for test devices using the identical application. Opening the .ret file content in a hex editor (I only use a single string retain var) I asked myself what the meaning of the first 24 bytes is. It neither contains a handle to the application nor a reference to the variable. Is this maybe a timestamp? Or a CRC/checksum? Regards, Thomas
Last updated: 2025-05-19

Post by dhumphries on Toggling Visualizations using HMI Physical Buttons CODESYS Forge talk (Post)
Nothing wrong with ladder, in a lot of applications it is simpler than ST or CFC, you're a lot less likely to have syntax issues in a ladder diagram than in structured text as long as you stick with traditional ladder elements. Your attempt was almost valid, but you tried to change the currentvisu variable using a blend of structured text and ladder, which isn't allowed. You need to use the MOVE operator and define the visualization name as a string on the input side and the visuelems.currentvisu as the target on the output side.
Last updated: 2024-02-28

Post by sumit on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
dhumphries, I changed the datatype this time from BYTE to USINT (because that's what my adapter is sending: array of uint8_t). The text "New Help String" you saw in previous screenshots is just the description of the input/s (it can be anything). I also looked into the logs (see attached) for that ! sign next to the device, I found that connection is being timeout. I tried some suggestions from online such as increase the RPI but still got connection timeout issue, also by changing the datatype, I still don't see incoming data from the adapter, although its visible on wireshark. thanks,
Last updated: 2024-03-07

Post by mariapaola on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3 CODESYS Forge talk (Post)
Hi, Would really appreciate your insights in this issue I have. I am currently using a WAGO 750-881 with multiple IO devices. For one of them I already occupied the MODBUS Master configuration tool so I cannot overwrite it for my other devices. I have a total of two serial interfaces WAGO 750-652. The first one is instantiated in COM2 and doesn't need any protocol since the information comes in an specific formatting that need little code to differentiate between needed info. This one is working just fine. The second one is where I have an issue. I have tried to instantiate the port using MODBUS library modb_L05.lib to properly receive the data from an ARDUINO and I am absolutely unable to open the port: Signal DEVICE2.fbModbus.MODBUS_EXT_MASTER.Interface.Com_Port_Ist_Offen is never TRUE, among with all other signals from that interface, while signal DEVICE1.COM2.Com_Port_Ist_Offen is TRUE, and the other signals also read as TRUE or FALSE. I have tried instantiating the second one as the first one, changing COM3 to COM4, I've tried a lot of things but it wont ever open the channel. I don't know if you have any recommendations for me. For both physical modules, both witness LEDs A and E are on. First one is instantiated like this: PROGRAM DEVICE1 VAR wBaudRate : WORD := BAUD_9600; bDataBits : BYTE := 8; bParity : BYTE := 0; bFlowControl : BYTE := 3; (RS422 FullDuplex with continous send) i : INT; COM2 : SERIAL_INTERFACE; xOpenPort2 : BOOL := TRUE; ( Flag to open the Port ) xInitPort2 : BOOL; ( Flag to initiallize the Port ) ReceiveBuffer2 : typRing_Buffer; END_VAR COM2( bCOM_PORT_NR := 2, cbBAUDRATE := wBaudRate, cbsBYTESIZE := bDataBits, cpPARITY := bParity, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := bFlowControl, utRECEIVE_BUFFER := ReceiveBuffer2, ptSEND_BUFFER := ADR(SendString2), xINIT := xInitPort2, xOPEN_COM_PORT := xOpenPort2, iBYTES_TO_SEND := LEN(SendString2)+1, xSTART_SEND := xSendActive2 ); Second one like this: PROGRAM DEVICE2 VAR COM4 : SERIAL_INTERFACE; xInitPort4 : BOOL := TRUE; xOpenPort4 : BOOL := TRUE; ReceiveBuffer4 : typRing_Buffer; fbModbus : MODBUS_EXTENDED_MASTER_RTU; fbError : enumMB_ERROR; stQuery : typModbusExtendedQuery; stResponse : typModbusResponse; au16Data : ARRAY[0..14] OF WORD; i : INT; tPoll : TON; END_VAR COM4( bCOM_PORT_NR := 4, cbBAUDRATE := BAUD_9600, cbsBYTESIZE := 8, cpPARITY := 0, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := 2, ( RS-485 half-duplex ) utRECEIVE_BUFFER := ReceiveBuffer4, xINIT := xInitPort4, xOPEN_COM_PORT := xOpenPort4, xSTART_SEND := xSendActive4, ); stQuery.SlaveAddress := 1; stQuery.FunctionCode := 3; stQuery.Read_StartAddress := 0; stQuery.Read_Quantity := 15; (Poll code) fbModbus( ENABLE := TRUE, bCOM_PORT := 4, ( COM4=> 750-652 port ) cbCOM_BAUDRATE := BAUD_9600, cpCOM_PARITY := 0, csCOM_STOPBITS := 1, cbsCOM_BYTESIZE := 8, cfCOM_FLOW_CONTROL := 2, TimeOut := T#500ms, StartFunction := xStart, ExtQuery := stQuery, Response := stResponse, MB_Error => fbError ); FOR i := 0 TO 14 DO au16Data[i] := stResponse.Data[i]; END_FOR;
Last updated: 2025-11-28

Post by testlogic on Sending Sequential Modbus TCP Packets CODESYS Forge talk (Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06

Post by andrej on Write to File on soft PLC winV3x64 CODESYS Forge talk (Post)
Hello all, I would like to store some data in text file. I use the soft PLC Win V3x64, on Windows 10. I use the SysFile Library 3.5.17.0. If I store the file directly in the in the directory of the PLC i.e. in '/CODESYSControlWinV3x64/E1FA7ABE/PlcLogic/LogAU.txt' the file is correctly filled with the data. However, If I use an absolute path to a different directory no data is stored in the respective file. Despite the fact that the respective file exists and the Filehandler is correctly opened (see in picture _fdSysFHandle <> -1). // sFileName : STRING := 'LogAU.txt'; // STORES FILE IN ../CODESYSControlWinV3x64/../PlcLogic/LogAU.txt' sFileName : STRING := 'C/Temp/LogAU.txt'// DOES NOT WORK --------------------- // FILE DESCRIPTOR _fdSysFHandle := SysFile.SysFileOpen( szFile:= sFileName,am:= SysFile.AM_APPEND,pResult := ADR(_Result)); Does some have an idea where the problem is, resp. how I can get store a file in an arbitrary directory. Thanks a lot and kind regards Andreas
Last updated: 2023-10-24

<< < 1 .. 21 22 23 24 25 .. 226 > >> (Page 23 of 226)

Showing results of 5637