Post by fabmorlino on Codesys v3.5 SP11 and Python scripts CODESYS Forge talk (Post)
Hi, I'm using codesys from a while, but I 'm not able to write phyton scripts. I whould like generate a PC txt file with the content of specific GVL codesys table, or better for my scope: a txt file from a STRUCT defined in CODESYS project. Any kind man could help me with some clue? Thanks Fabrizio
Last updated: 2024-04-05

Post by hanoues on Holding brake release CODESYS Forge talk (Post)
I've tried using the SMC3_BrakeControl function block to control the brake, but unfortunately, it's not functioning as expected. Despite setting the appropriate parameters and inputs, the brake control does not operate correctly. Any insights or suggestions on resolving this issue would be greatly appreciated. STATE_MANUAL.UNLOCK_BRAKE: IF Button_release_brake THEN GVL.drum1_Control_Brake:=TRUE; FBA.T11_ContBrake.bExecute := TRUE; GVL.manual_state := STATE_MANUAL.WAIT_FOR_BRAKE_RELEASE; END_IF STATE_MANUAL.WAIT_FOR_BRAKE_RELEASE: IF FBA.T11_ContBrake.bDone THEN FBA.T11_ContBrake.bExecute := FALSE; GVL.manual_state := STATE_MANUAL.WAIT_START_BUTTON; END_IF
Last updated: 2024-04-08

Post by danwoodlock on Rpi zero w lost license after 4.11 update CODESYS Forge talk (Post)
Just adding some info: Today I found this post: https://forge.codesys.com/forge/talk/Runtime/thread/264bd530d4/ followed the steps suggested started with a fresh install of raspbian lite, installed 4.11, and then attempted to import my license update file. I get this when I do: Any help is appreciated.
Last updated: 2024-04-15

Post by k2saki on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment . CODESYS Forge talk (Post)
Hi, gseidel. Thank you so much for your advice. I have created a program to preprocess G-code as follows 1.SMC_ReadNCFile2 2.SMC_Interpreter 3.SMC_CheckVelocities Then I put SMC_OUT_QUEUE in SMC_Interpolator. Where should I insert SMC_SmoothMerge and SMC_SmoothPath? Or are there any example link for it ?
Last updated: 2024-04-30

Post by arslan on G Code Position Shifting CODESYS Forge talk (Post)
Dear friends, I have a issue that. I would like to give a zero offset of any axis in G-Code by G54 from PLC code as below demonstration. N000 G00 X0 Y0 Z0 N010 G54 (offset from PLC) N020 G01 X0 Y0 Z0 . . How to fix it! BR
Last updated: 2024-05-02

Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
I'm trying to get the OPC server setup on my machine and currently I'm not having luck. I went ahead and got my license setup. However when I go to run WinCoDeSysOPC.exe I get an error message that I don't have the code meter licenses installed. Does anyone have any ideas on how I can fix this issue?
Last updated: 2024-05-02

Post by andrej on Channel timeout CmpChannelMgr CODESYS Forge talk (Post)
Hello, I use Codesys RTE 3.5.16.5. If I connect to the PLC I often get the following message: (see printscreen) 1. Channel timeout CMpChannelMgr. 2. Closing connection CmpChannelMgr. Can you tell me, what the meaning of this is? What does the number 1250030,1220020 resp. c400:0a0a:015a:0301 refer to? I could find any information in the online help. Thanks a lot.
Last updated: 2024-05-08

Post by matthew on New Ladder Diagram conversion does not work due to missing features CODESYS Forge talk (Post)
Hi @eschwellinger Just wondering if there is any update when the Expression or part of it has no effect will be fixed? Also have the ability to open an FB when online and offline. It would also be great to be able to view the ST code block when online.
Last updated: 2024-05-14

Post by mani-i4point0 on CODESYS Development System V3 ( 3.5.19.70 ) on Windows Virtual Machine CODESYS Forge talk (Post)
Hi, I have a requirement where in need to install a CODESYS Development System V3 ( 3.5.19.70 ) on a Window 10 which is running in VM. Is there any limitation of functions and features of using CODESYS Development System V3 ( 3.5.19.70 ) installed in Window 10 which is running in VM. Please do advice. Best Regards, Mani
Last updated: 2024-05-14

Post by mani-i4point0 on CODESYS Development System V3 ( 3.5.19.70 ) on Windows Virtual Machine CODESYS Forge talk (Post)
Hi, I have a requirement where in need to install a CODESYS Development System V3 ( 3.5.19.70 ) on a Window 10 which is running in VM. Is there any limitation of functions and features of using CODESYS Development System V3 ( 3.5.19.70 ) installed in Window 10 which is running in VM. Please do advice. Best Regards, Mani
Last updated: 2024-05-14

Post by xiaoyan on Generic EtherCAT slave CODESYS Forge talk (Post)
Hello Well i need some basic advice. My protegoD drive is shown deactivated in the device tree. i can see its variables and other i/o in online mode but the device itself is deactivated. how can i address this issue. is there any configuration error.using ethercat link to connect to protegoD by Primo MC plc
Last updated: 2024-05-16

Post by mgengler on Recipe Manager - Not Creating Recipe Files CODESYS Forge talk (Post)
Thanks for info... However, I changed the directory to: C:\ProgramData\CODESYS\CODESYSControlWinV3x64\58719825\PlcLogic\Recipes It still displays the content of this folder OK, however still will not write or read files. Is this the PLCLogic area you speak of? I also tried adding this path the the CodesysControl.cfg file. But still can't get it to work. Any additional direction would be appreciated!
Last updated: 2024-05-20

Post by rd76065 on Opto 22 Groov PR2 Modbus TCP Master communication CODESYS Forge talk (Post)
Previously, I have used ModbusEthernet_04 library for Wago for ModbusTCP Master communicational in Codesys V2.3. How to use same communication of similar UDT for Opto22 Groov PR2 PLC in Codesys V3.5 SP20. Can I use OSCAT library - Network -MB_Client or IODrvModbusTCP - ModbusRequest for this requirement? If any other please guide.
Last updated: 2024-05-31

Post by davidmic on Is it possible to profile builds? CODESYS Forge talk (Post)
Hi I have a large project (which I can't share here), builds take multiple minutes. My computer is reasonably new (i7-10610U, 32gb ram), and I don't think my company will let me upgrade. Is there any way to profile/inspect the build process? My goal is to figure out why builds take so long, then hopefully I can make them faster.
Last updated: 2024-06-05

Post by davidmic on Is it possible to profile builds? CODESYS Forge talk (Post)
Hi I have a large project (which I can't share here), builds take multiple minutes. My computer is reasonably new (i7-10610U, 32gb ram), and I don't think my company will let me upgrade. Is there any way to profile/inspect the build process? My goal is to figure out why builds take so long, then hopefully I can make them faster.
Last updated: 2024-06-05

Post by kumareasu on Persistent variable storage CODESYS Forge talk (Post)
Is there any function function block which can store the persistent variable in HDD/SSD immediatley. My observation is that the persistent variable is getting stored when we shut down or restart the system (Windows+ CoDeSys RTE SL ). the persistent variables are not stored in HDD/SSD, if I power off the system without proper shutdown. Seeking your feedback.
Last updated: 2024-06-12

Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device CODESYS Forge talk (Post)
I have now conducted some tests. The problem occurs when the Python script establishes an OPCUA connection, even if I only establish the connection without reading or writing any data. Is there another way to exchange data between Python and CODESYS without having to put in a lot of effort?
Last updated: 2024-06-24

Post by xabier on License Activation Problems CODESYS Forge talk (Post)
I bought two license and install with out problems....but the problem was when i changed the image in my controler and when i want activated again the license i have a problem Appear this 2 softcontainer and i can´t install any license again... Can someone help me please?
Last updated: 2024-06-24

Post by koppit on SysComRead Timeout Parameter CODESYS Forge talk (Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26

Post by snguyen on Any ways to prevent Infinite scroll when moving an object to the left or top edge? CODESYS Forge talk (Post)
I've been making few HMIs and I'm starting to get annoyed that whenever I try to align an object to the left or top side of the frame, it quickly scrolls into that direction infinitely. Is there a way to prevent that?
Last updated: 2025-10-24

Post by fahrettin on CODESYS 3.5.17.30 Setup Error CODESYS Forge talk (Post)
While trying to install CODESYS 3.5.17.30 (64-bit) on my Windows 11 computer, I'm getting the errors below. The first error occurs near the end of the installation. Once you bypass it, the installation returns the second error. Do you have any suggestions for a solution? By the way, I've tried this on several PCs, but I haven't found a solution.
Last updated: 2025-10-30

Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
I AM VERY GRATEFUL FOR YOUR HELP. I HAVE INSTALLED: CODESYS SOFTMOTION VER. 4.19.0.0 AS SEEN IN THE ATTACHED FILE. BUT IT DOESN'T CHANGE THE FACT THAT I GET 6 ERRORS WHEN I HAVE INSTALLED SM_Drive_RaspiStepper_Direct DO YOU HAVE ANY SUGGESTIONS ON WHAT I CAN DO NOW? /KLAUS
Last updated: 2025-11-10

Post by scrisp on Source code changes since last download CODESYS Forge talk (Post)
Why does CODESYS 3.5 show the message “Source code changes since last download” even though I did not create or modify any new variables? When I go online with the PLC, it detects changes and suggests synchronizing, but nothing was actually changed in the project. What could cause this and how can I fix it?
Last updated: 2025-11-28

Post by michaelhepiroc on CIA405.RECV_EMCY CODESYS Forge talk (Post)
Hi Reinier, I'm wondering if you managed to get this FB to work? I was just trying it, and found it not to work, I get an EMCY message in the CodeSys program under the Device Status, but the FB doesn't pick up any EMCY messages from the Bus. Cheers.
Last updated: 2025-12-08

Post by gatto on warning C0195 CODESYS Forge talk (Post)
Good morning dear codesys users. I'm using 3.5.20.40 and I get this warning C0195 when I assign an initial value to xyz. However, if I do it on a single byte (abc), it doesn't display any warning. Why? VAR_GLOBAL abc : BYTE := 100 ; xyz : ARRAY [1..10] OF BYTE := [10(100)] ; END_VAR