Post by eschwellinger on Editor FIND highlight color
CODESYS Forge
talk
(Post)
To change the color of search result markings (the "find color") in the CODESYS Text Editor using Themes, follow these steps: Go to the menu: Tools → Options. In the Options dialog, select the Text editor category. Switch to the Theme tab. Here, you can select your desired color theme for the text editor. The available color schemes (themes) are stored in the installation directory in the Themes folder. To specifically adjust the color for search result markings, go to the Text Area tab within the Text editor options. Here, you can customize the Selection color – Inactive parameter, which determines the color used to highlight search results. Changing the theme will apply a new set of color settings, including those for selections and search highlights. If you want further customization, you can manually edit or create your own theme files in the Themes folder of your installation directory Example "c:\Program Files\CODESYS 3.5.21.50\CODESYS\Themes\myDefault.editortheme" https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_options_text_editor.html
Last updated: 2026-03-12
Post by taywinkel on Virtual Keyboard Support on Login Page
CODESYS Forge
talk
(Post)
I am in the process of getting a visualization to work with the codesys keyboard. I created a custom keyboard which works fantastic for all input fields in the main visualization. I created a user management for my runtime, which gave me the standard blue login page. The codesys keyboard does not show up when trying to enter the usernam or password. I have tried every setting: changing the keyboard back to the standard codesys keyboard, and changing various settings on the visualization manager with no success. I can only use a physical keyboard connected to the device to enter the password. I did try removing the keyboard to no success either. I even tried creating my own login page so I could guarantee the keyboard showed up. This ended in disaster as I could not figure out the very complicated VisuUserManagement and VisuUserManagementDialog library, and documentation is contradictory or lacking. I imagine that an on screen keyboard is essential for many people's projects when using touchscreen panels, so I am wondering what others are doing. I would rather not use an external virtual keyboard (external to codesys) because this causes its own complications (I am working on a linux build with high securities).
Last updated: 2026-03-22
Post by martinlithlith on Raspberry Pi: List of available drivers / libraries
CODESYS Forge
talk
(Post)
As most of the posts are moved here around 2015, what would be the right version of codesys to run? Would it be better to install a older version of codesys or should i keep on downgrading libraries? Is there any work done to update theses libraries? It´s been a few years since the last update in this post, are there new libraries/devices for raspberry being added/posted somewhere else? Thanks, Martin
Last updated: 2023-10-17
Post by snhatton on Running webvisu with Codesys Control Win V3 in Simulation Mode
CODESYS Forge
talk
(Post)
Yes, you can use the CODESYS ControlWin V3 Soft PLC. However, if simulation is enabled on the device this will disable all communication, so you need to turn off simulation to view the visualization in a web browser. In simulation mode, all IO and communication is disabled for standalone testing. In addition, make sure to set the start visualization in the WebVisu object in the application tree. I hope this helps!
Last updated: 2023-12-04
Post by vamsi on How to configure gateway for programming RPi 2B using Codesys
CODESYS Forge
talk
(Post)
I found out what I was doing wrong. I was entering the wrong IP in the gateway. I found that I have to enter the RPi's IP in the gateway field from this post https://forge.codesys.com/forge/talk/Runtime/thread/01703ca970/#d9f6 But I do not understand why it has to be the RPi's IP. Could anyone help me in clarifying this?
Last updated: 2024-07-10
Post by timvh on No source code available for this object
CODESYS Forge
talk
(Post)
The message means that you (CODESYS) tries to open the function block, but this is not possible because the library which contains the FB is compiled. You either get this when you try to manually open the function block (while editing the application), but it could also happen that an exception occurs in the running application and CODESYS tries to show the location where it occured. If it happened in an FB of the compiled library, it cannot show this and you could get this message too.
Last updated: 2024-07-16
Post by taqamert on Codesys 2.3 & Peak PCAN
CODESYS Forge
talk
(Post)
Despite working on it for days, I haven't achieved any results. I followed the necessary steps one by one as mentioned in the file you sent, but there hasn't been the slightest change. I couldn't find the step you mentioned "Set the 'Can Board Type' to PCAN USB" in the Word document. There is no such setting anywhere I looked. Is there a more detailed explanation available, or can you explain it in more detail? What am I missing?
Last updated: 2024-07-16
Post by elektron785 on Dongle von Linux-Modul (ARM64) nicht erkannt
CODESYS Forge
talk
(Post)
Die Ausgabe bei lsusb ist im ersten Post im Bild usb.png zu sehen - der Dongle wird als WIBU Systems CmStick erkannt. Um Codesys als Soft-PLC darauf zum laufen zu bekommen habe ich das Addon Codesys Control for Linux ARM SL installiert und mir einen Docker gebaut mit den Dateien: codesyscontrol_linuxarm64_4.10.0.0_arm64.deb und codemeter-lite_7.60.5625.503_arm64.deb Wenn ich den Docker ausführe sind die beiden Programme ja inbegriffen und Codemeter sollte eigentlich die Erkennung des Dongles sicherstellen. Gibt es eine Möglichkeit festzustellen, dass Codemeter korrekt ausgeführt wird?
Last updated: 2024-09-05
Post by paulpotat on cm4 runtime problem
CODESYS Forge
talk
(Post)
Hello again, After looking into it, I noticed that the release note of "CODESYS Control for Raspberry PI 4.13.0.0" mentions a bug fix titled "Support Compute module 4". Is it possible to have more details about this fix from the CodeSys team please ? Because I have several CM4 boards with the same hardware revision / OS but some of them works with the 4.10 runtime and others only works with the 4.13 runtime...
Last updated: 2024-09-09
Post by stribor on Passing properties as VAR_IN_OUT variables.
CODESYS Forge
talk
(Post)
I am designing a custom slider object and i ran into a problem when i want to use properties with it. I can update the basic variables if i have a slider variable defined as VAR_IN_OUT, but it does not work with properties. How can i achieve same functionality that some basic objects have (for example basic Slider that comes withing the codesys libraries) such that i can pass both variables and properties to it and they can be modified within the object? I am using Codesys V3.5 SP20 Patch 5.
Last updated: 2025-03-01
Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess)
CODESYS Forge
talk
(Post)
Wow! Thanks mr Strucc. Changed to service to run as local acc, and now log works! The service (run from local acc) is using this config: C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg The path you first mentioned (c:\Windows\System32\config\systemprofile\AppData\Roaming) has no CODESYS folder in it (Windows 11 24H2 b26100.3194). Thanks for your help :)
Last updated: 2025-03-06
Post by jvfred on Reading a negative number
CODESYS Forge
talk
(Post)
I have a Codesys-based Eurotherm E+PLC400 connected to Codesys HMI SL for visualization. I am also bringing in several Pressure Indicators via the Ethernet. Everything works; however, the Pressure indicators sometimes read a negative value. When they do, the displayed value on the screen reads "65532." While I know what it represents, the customer freaks out and wants it to read "0" or a negative number. The value comes in as an integer, just in case that matters. Does anyone have any ideas?
Last updated: 2025-05-22
Post by sandro66 on Application-based license Modbus Channels
CODESYS Forge
talk
(Post)
Hi Gatto, Using version 3.5.21.xx, it is no longer possible to use Modbus function blocks (I make extensive use of these FBs.)as shown in the example. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_modbus_example.html The compiler detects one Modbus instance for each instance of the communication FB block. The example program above, although simple, reports 8 Modbus instances when compiled with the latest version. Codesys Support says that you must use fieldbus I/O mapping, but this will result in the loss of the ability to programmatically modify communication parameters. Sandro
Last updated: 2025-09-04
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Dear Eschwellinger, Thank you for the response. Does that mean that the license-manager inside the Codesys-IDE does not work with this setup anymore? Because when I use this I get the notification that there is no dongle attached to the device (see picture). And If I insert the license by the deploy tool, can I then redeploy the Codesys virtual control container, or does this erase the license completely?
Last updated: 2025-09-30
Post by svn123 on In Simulation Mode, logic is not executing
CODESYS Forge
talk
(Post)
Please check the attached snapshot. I am converting an int to real and storing in rVlv01_SV and then scaling the value using LIN_TRAFO. In the bottom Status Bar of Codesys, both RUN and SIMULATION are visible. When I enter value 100 as input to INT_TO_REAL instruction and press Ctrl-F7, the value can be seen at the input but the logic seems not to work. I searched for help but could not find anything relevant. What could be the reason. Codesys ver3.5.11 svn
Last updated: 2023-12-25
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
the TCA9548a does not work in Codesys. In Pyton this is only queried once and in Codesys cyclically. Of course you can also insert a terminating resistor in each port, then you should have no problems. I use this one: https://botland.de/8-bit-multiplexer/12723-qwiic-mux-breakout-8-kanal-modul-mit-i2c-multiplexer-tca9548a-sparkfun-bob-16784-5904422341428.html You can simply set the library to the latest version. You do not need Oscat. Do you need an example project for the BMP280?
Last updated: 2024-01-02
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
the TCA9548a does not work in Codesys. In Pyton this is only queried once and in Codesys cyclically. Of course you can also insert a terminating resistor in each port, then you should have no problems. I use this one: https://botland.de/8-bit-multiplexer/12723-qwiic-mux-breakout-8-kanal-modul-mit-i2c-multiplexer-tca9548a-sparkfun-bob-16784-5904422341428.html You can simply set the library to the latest version. You do not need Oscat. Do you need an example project for the BMP280?
Last updated: 2024-01-02
Post by toby on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option
CODESYS Forge
talk
(Post)
Hi Edwin, Thanks for the message. My apologies I should have researched this more thoroughly before posting on here. I found a solution to my issue on this post: https://forge.codesys.com/forge/talk/Runtime/thread/6455efaa17/ I needed to run the 'CODESYS Installer' as an Admin, then install the RPi package v4.10.0 in to my package (v3.5 SP19 Patch 5). Thanks, hope you have a good day. Toby
Last updated: 2024-01-09
Post by durstloescher on Codesys Input Detector
CODESYS Forge
talk
(Post)
Good morning, I am currently working on implementing a display dimmer. I want the display to dim after X minutes. This works so far. The implementation is done via the Linux subsystem, to which a command is sent to dim the display. However, my problem is resetting the timer when input is received. I want the dimming timer to be reset with each click/touch. Unfortunately, I can't find a suitable solution for this. Are there any ways to do this? Codesys v3.5 SP19 Patch 2
Last updated: 2024-02-15
Post by nano on Is there any support for I2C on Raspberry Pi?
CODESYS Forge
talk
(Post)
hello jdj this question can be answered well with a pretty good forge documentation: https://forge.codesys.com/drv/io-drivers/doc/Generic/ u r also able to create in codesys directly an iec-code by using the i2c-interface as driver using the codesys ide and st depending on the stepperdriver, used in yöur hat, its possible that an driver is already available in the device-repository. which mcp-device is used on the hat?
Last updated: 2024-03-01
Post by remcoborghuis on C0032 Error to type Pointer to IoConfigParameter
CODESYS Forge
talk
(Post)
Hi All, I'm using codesys on a raspberry PI. I use V3.5 SP18 Patch 2 development system and codesys for raspberry pi 4.8.0.0. Sometimes when I build the project I get error messages C0007: Expression expected instead of ',' and C0032: Cannot convert type 'Unknow type: '!!!'ERROR'!!!" to type 'POINTER TO IoConfigParameter'. I can't click on the message to bring me to the fault. After I do a "Clean all" the build finishes successful. Anyone who can help me with this problem? Thanks! Remco Borghuis
Last updated: 2024-03-25
Post by dkugler on Codesys SVN
CODESYS Forge
talk
(Post)
Don't set on SVN. The service phase has started in March 2024 and will be discontinued in 2027. We actually use SVN and have to switch to GIT in the future. As I informed, there is no way of getting a single SVN or GIT licence. I' dont understand, why Codesys forces us customers to pay for an expensive Professional Edition paket from year to year using only one part of it! If you find a way to buy a single licence, let me know.
Last updated: 2024-04-29
Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors
CODESYS Forge
talk
(Post)
Update: I started over. I saved progress at each step. all compiled zero errors, zero warnings. Pre-processor messages remain, but I can make progress. Until I try to re- load the project file in Codesys. Re-loaded files error as above when compiled, even though they compiled error-free immediately before saving. Is my installation borked? (Not easy to re-install due to IT madness...)
Last updated: 2024-05-03
Post by totorovic on Softmotion not working with simulation mode
CODESYS Forge
talk
(Post)
Good morning, I think that the mode Simulation does not support the Softmotion functionnality because it runs the CODESYS process with normal priority wich is not a good thing for real-time behavior. If you want to test your PLC project, please use a Codesys Control Softmotion (and your computer must have the Ethercat driver installed) or much easier, download your code into the C6 Smart. BR
Last updated: 2024-05-13
Post by kris-samoy on Get Alarm status in Codesys
CODESYS Forge
talk
(Post)
I am rather new to Codesys and I'm trying to figure out how to get the status of an alarm. This to interlock the start of a device until the alarm has been acknowledged... I am not sure if IAlarm.GetState (METH) can be used for this purpose. If yes then could someone please briefly explain how to use this? https://content.helpme-codesys.com/en/libs/AlarmManager/4.1.0.0/Interfaces/pou-IAlarm/GetState.html Thx & grtz, Kris
Last updated: 2024-06-03
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.