Post by eschwellinger on PFC100 Licensing fails
CODESYS Forge
talk
(Post)
possible to use a newer version? maybe it is /var/opt/codesys/cmact_license in your version
Last updated: 2024-03-19
Post by kevinrn on Licensing info not available.
CODESYS Forge
talk
(Post)
I'm facing a similar issue. @eschwellinger, can you also send me a preliminary version? Thank you in advance.
Last updated: 2024-03-21
Post by eschwellinger on License problem gateway
CODESYS Forge
talk
(Post)
as a workaround just plug your USB key to the CODESYS PC - and activate the ticket by the browser license.codesys.com
Last updated: 2024-03-27
Post by eschwellinger on Rpi zero w lost license after 4.11 update
CODESYS Forge
talk
(Post)
Please write to 'my question' in the CODESYS Store.
Last updated: 2024-04-16
Post by eschwellinger on License problem gateway
CODESYS Forge
talk
(Post)
Is this a computer with installed CODESYS ? Codemeter is needed to activate licenses via Browser...
Last updated: 2024-04-17
Post by eschwellinger on Licensing info not available.
CODESYS Forge
talk
(Post)
we recommend to do it with the official virtual plc version..will send a version.
Last updated: 2024-05-23
Post by eschwellinger on New License not working.
CODESYS Forge
talk
(Post)
please use 'my question' in the CODESYS Store to ask for support
Last updated: 2024-05-24
Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10
Post by gennady on Licensing info not available.
CODESYS Forge
talk
(Post)
Hello, I'm having the same problem. But I used HCFA PLC, the error message is same.
Last updated: 2024-07-09
Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins
CODESYS Forge
talk
(Post)
OPTO22 Codesys Activation license not active.
Last updated: 2024-09-11
Post by irshad on Bought a license, but can't activate
CODESYS Forge
talk
(Post)
Hi, Am having the same issue.. Charge ID ch_3Q8iRXJ3NuAV8W161ZdlLsBm
Last updated: 2024-10-11
Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Because we bought several raspberry pi licenses that can only be activated with a raspberry pi runtime.
Last updated: 2024-10-17
Post by davidbo on RPI How to login for a copy of the SD image
CODESYS Forge
talk
(Post)
I had one RPI device where I could login. I copied the SD-flash over to another SC-flash. This new SD-flash was inserted in the new device. I can boot the new device but I cannot login why? How can I install an application on this new device? Control 4.4.0.0 cat os-release PRETTY_NAME="Raspbian GNU/Linux 11 (bullseye)" NAME="Raspbian GNU/Linux" VERSION_ID="11" VERSION="11 (bullseye)" VERSION_CODENAME=bullseye ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs"
Last updated: 2023-10-18
Post by eschwellinger on Correct CAN Driver for EL6751
CODESYS Forge
talk
(Post)
Hi, for Control Win : add CmpEL6751CanDrv in the c:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE\CODESYSControl.cfg [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=CmpEL6751CanDrv for Linux SL or Pi or any ARM device - I think it is already static loaded as component - see plclogger on startup
Last updated: 2023-09-20
Post by mehmetembedded on Linux ARM64 SL, GPIO Access
CODESYS Forge
talk
(Post)
Hello. I am using TI AM64x evaluation board TMDS64EVM. It has 8 leds connected via I2C to SoC.I wanna control them via codesys GPIO device. Is that possible? If so how I can do it. I had no problem installing codesys runtime, and running program on device. But when it comes to GPIO access, It couldn’t make it.
Last updated: 2024-05-08
Post by mehmetembedded on Linux ARM64 SL, GPIO Access
CODESYS Forge
talk
(Post)
Hello. I am using TI AM64x evaluation board TMDS64EVM. It has 8 leds connected via I2C to SoC.I wanna control them via codesys GPIO device. Is that possible? If so how I can do it. I had no problem installing codesys runtime, and running program on device. But when it comes to GPIO access, It couldn’t make it.
Last updated: 2024-05-08
Post by eschwellinger on Recipe Manager - Not Creating Recipe Files
CODESYS Forge
talk
(Post)
With Linux SL and Windows Control Win - with this example https://forge.codesys.com/prj/codesys-example/recipe-manageme/home/Home/ We see in the PLClogic directory the generated recipe files see my screenshot. c:\ProgramData\CODESYS\CODESYSControlWinV3x64\XXXXXXXX\PlcLogic\Hello.RecipeDef.txtrecipe c:\ProgramData\CODESYS\CODESYSControlWinV3x64XXXXXXX\PlcLogic\ABC123.OtherRecipes.txtrecipe
Last updated: 2024-05-21
Post by kees-b on PLCnext Phoenix Contact
CODESYS Forge
talk
(Post)
Hello We started with the new design of Codesys, through a "CODESYS Control Standard S" license. However, after installing the license, connecting, etc. (without any problems), we cannot get the program into the PLC with entries that we have not seen before. Is there anyone who has also experienced this? Better yet, does anyone have the solution?
Last updated: 2024-01-24
Post by eschwellinger on License problem gateway
CODESYS Forge
talk
(Post)
most important information are missing: Which CODESYS Version? Which runtime version? Which plc type (manufacturere).. Not all plc manufacturer already support application based licenses. From your pictures I see you have activated 4 axis Motion (which is an applications based license type) does only work on plc's which do support this.
Last updated: 2024-04-25
Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License
CODESYS Forge
talk
(Post)
I'm trying to get the OPC server setup on my machine and currently I'm not having luck. I went ahead and got my license setup. However when I go to run WinCoDeSysOPC.exe I get an error message that I don't have the code meter licenses installed. Does anyone have any ideas on how I can fix this issue?
Last updated: 2024-05-02
Post by totorovic on IO-LINK Package - new license model
CODESYS Forge
talk
(Post)
Hello, I'm using th IDE Combivis studio 6 (codesys based) and I get an error message when I use IO-link. "The license is missing or invalid. The API is running in demo mode." However the package Manager indicates that no licence is required. It used to work, it seems that the free package has become a paying one. Can Codeys confirm this? BR
Last updated: 2024-06-06
Post by karol-abktech on Raspberry and problem with runtime
CODESYS Forge
talk
(Post)
Hi, My problem is with raspberry pi 4 with 2 GB ram,. Install codesys is correct but runtime works only few seconds or I can connect with device few seconds. I can ping raspberry and in system info I can see " !!!! Warning: no runtime license - running in demo mode(~2 hours)" but it is 2 minutes after runtime. When I press Start runtime I have another few seconds when I can connect to raspberry. After this time I couldn't find device. Of course, reapet start runtime works every time on few second. Raspberry is new and works with fresh install raspberry os 32 bit. Where should I start looking for solve of my problem ?
Last updated: 2024-02-14
Post by forest on SM Drive license error
CODESYS Forge
talk
(Post)
Hi, when it comes about license, I used INVTmatic Studio, which uses Codesys, for programming INVT plc. I bought Codesys Modbus license, it was not expensive, and then realised that INVT didn't have License Manager option (greyed out in program) which is needed for using of Codesys License. I contacted support from INVT, but developers told me that option is still not available. So depending on environment for programming Codesys, you can or not use Modbus license. Good thing about this version of Modbus TCP it works both direction. I could send commands and receive feedbacks from drive. But communication stops after 30 mins. So I used simple version of ethernet modbus which is somewhere in INVT or Condesys library (I can check tomorrow) which works only one way. I could send cmd to drive, and control it, but didn't have any feedback, like some readings back in PLC. which is bad, but at least I could start it and it didn't fail after 30 mins.
Last updated: 2024-01-10
Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
Thanks for this - I have now been looking in to just having an extra (non-RTE) runtime on the same machine, as you suggest. I will probably proceed this way. Even though it still seems very odd to me, that variable exchange to a different runtime is easier than between applications on the same controller. There will be some fun with the licensing, it seems. Does anyone know if it is possible to specify which license container/specific license the runtime is going to use at runtime. Let's say I have two available licenses with different resources available, for example one license allows multicore and multiple EtherCAT channels, but not many visu tags (for the RTE). Another with less resources but a lot of visu tags (for the Visu controller). Let's say the program in one of the controllers could be fully licensed by either of the two available licenses, but picks the 'largest' first. A bit later, the larger application starts, but is left with the smaller license.. How can I make sure that the 2 runtimes select the right license at startup?
Last updated: 2024-10-01
[operating system] command to detect whether runtime is over LINUX or WIN ?
CODESYS Forge
talk
(Thread)
[operating system] command to detect whether runtime is over LINUX or WIN ?
Last updated: 2020-02-24
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.