Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
The machine I'm currently using (Celeron J1900) already has the Kernel RT patch. I checked the performance according to the documentation. After running CyclicTest for 4 cores, the value for each core is around 6-7. I went through the entire process according to the documentation (I envy the TaskMonitor results in the documentation). The documentation states: "CODESYS Virtual Safe Time Provider The CODESYS Virtual Safe Time Provider is a standard interface that the user can use to transfer a second and external time base to the CODESYS Virtual Safe Control. The implementation is done as a client, which must run on another system with an independent time base." How do I implement this? I've been struggling for two weeks now - I'm too old to give up.
Last updated: 5 days ago
Post by jeindhoven on Deploying to raspberry pi 5 hangs
CODESYS Forge
talk
(Post)
Hi CoDeSys support forum, hope that this is the correct place to ask this. Might be double as i am new to Codesys and dont know all terminology. I am trying to test Codesys with a virtual plc on a raspberry pi 5. Already figured that i need Tools -> Deploy Control SL, enter Communication parameters. Codesys says "Connected". Then tab "Deployment", there i select "CODESYS Control for Raspberri Pi SL" and "4.16.0.0 (all)". Click "Install" and the gui turns grey and unresponsive. The titlebar says "Untitled1.project - CODESYS (Not Responding)" as well. Restarting Codesys and checking shows no package was installed. How to deploy the runtime? Thank you in advance for your time. Edit: After some patience, an error showed up: "Error when sending ssh heartbeat: Session operation has timed out" "Error installing codesyscontrol" Any pointers to what remote command might have failed, or log of some sort, would be welcome. Software versions: Codesys version 3.5.21.10 Raspberry pi 5 (deployment machine): $ uname -a Linux raspberrypi 6.1.21-v8+ #1642 SMP PREEMPT Mon Apr 3 17:24:16 BST 2023 aarch64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 11 (bullseye) Release: 11 Codename: bullseye $ apt list --installed | grep openssh-server openssh-server/oldstable,now 1:8.4p1-5+deb11u3 arm64 Development machine: $ uname -a Linux 2B 6.1.0-35-amd64 #1 SMP PREEMPT_DYNAMIC Debian 6.1.137-1 (2025-05-07) x86_64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm VirtualBox Version 7.0.26 r168464 (Qt5.15.8) Virtual OS: Windows 10 Pro 64-bit (10.0, Build 19045) .NET version 4.0.30319.42000
Last updated: 2025-06-22
I want to control a industrial machine with "CODESYS Control Win V3" and a Profibus_DP slave
CODESYS Forge
talk
(Thread)
I want to control a industrial machine with "CODESYS Control Win V3" and a Profibus_DP slave
Last updated: 2018-09-24
Difference between CODESYS Control RTE x64 and CODESYS Control RTE V3 x64
CODESYS Forge
talk
(Thread)
Difference between CODESYS Control RTE x64 and CODESYS Control RTE V3 x64
Last updated: 2021-05-10
Post by erictur on CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC
CODESYS Forge
talk
(Post)
UC3100 comes with Arm Cortex-A8 1 GHz and belongs to Moxa Industrial Linux 1 (Debian 9) for Arm-based Computers. I tried to install the CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC. Unfortunately, the Third-party requirements: - libc >= 2.27 (required by CodeMeter Runtime) of the CODESYS Control for Linux ARM SL cannot be met on the Debian 9, which comes with glibc 2.24. I read the post by @johnlee (Getting Start with Codesys Control for Linux SL) (https://forge.codesys.com/forge/talk/Runtime/thread/0a515ced3f/). Where he discusses installation of CODESYS Control for Linux ARM SL on Debian 9. There was CODESYS Linux runtime v3.5.14 availble and it was successfully intalled on the Debian 9. However, the CODESYS Store has the oldest version V4.1.0.0 32 bit available. There is no way to find the CODESYS Linux runtime v3.5.14. So is there any work around for this? Or I cannot install the CODESYS Runtime on any of the Moxa IPCs based on the Moxa Industrial Linux 1 (Debian 9)?
Last updated: 2025-07-10
Post by latassan on RaspberryPi 5 gateway problem
CODESYS Forge
talk
(Post)
Hello, I'm trying to use a raspberryPi 5 as a PLC. I fixed its IP address, I can ping it. I've also installed the CODESYS Control for Raspberry Pi 64 SL runtime on it. So I've created a gateway (IP address of the Raspberry, TCP port 1217). I see the green dot next to this gateway. When I do a network scan, I can see my raspberry (see photo). When I try to connect to it, I have to define an administrator profile, which I do. On validation, I see a message: No device is responding to the scan request. I've checked that port 1217 is listening on the raspberry, I've uninstalled the runtime then installed it again, but I can't connect. Also, when I try to configure the user groups before connecting, I see that Offline mode is not supported by the device, even though I'm connected to it in the Deploy Control SL tab. When I try to refresh, I see: Gateway not configured properly. How can I connect to my Raspberry? Have I defined my gateway incorrectly?
Last updated: 2025-06-12
Start Control Win Softmotion Runtime
CODESYS Forge
talk
(Thread)
Start Control Win Softmotion Runtime
Last updated: 2023-08-23
Moved To: Control double acting valve
CODESYS Forge
talk
(Thread)
Moved To: Control double acting valve
Last updated: 2016-10-18
Axis control whit Softmotion question
CODESYS Forge
talk
(Thread)
Axis control whit Softmotion question
Last updated: 2019-08-08
IO-Karten fΓΌr Control Win
CODESYS Forge
talk
(Thread)
IO-Karten fΓΌr Control Win
Last updated: 2016-01-19
Python script command for "Access Control"
CODESYS Forge
talk
(Thread)
Python script command for "Access Control"
Last updated: 2024-07-18
Codesys + BeagleBone PLC +LED control
CODESYS Forge
talk
(Thread)
Codesys + BeagleBone PLC +LED control
Last updated: 2024-08-12
Codesys Virtual Control - startup problem
CODESYS Forge
talk
(Thread)
Codesys Virtual Control - startup problem
Last updated: 2024-08-19
control loop library IIR filter
CODESYS Forge
talk
(Thread)
control loop library IIR filter
Last updated: 2025-08-01
Cursor to move to a control
CODESYS Forge
talk
(Thread)
Cursor to move to a control
Last updated: 2025-08-12
Control for Raspberry Pi 4.17
CODESYS Forge
talk
(Thread)
Control for Raspberry Pi 4.17
Last updated: 2025-09-08
Electric shutter with slider control
CODESYS Forge
talk
(Thread)
Electric shutter with slider control
Last updated: 2017-10-14
Revision Control without ENI
CODESYS Forge
talk
(Thread)
Revision Control without ENI
Last updated: 2011-06-07
Safety (SiL2) mit Control Win
CODESYS Forge
talk
(Thread)
Safety (SiL2) mit Control Win
Last updated: 2018-08-07
Variable text for register control element
CODESYS Forge
talk
(Thread)
Variable text for register control element
Last updated: 2020-01-22
OPC Really slow with Control RTE
CODESYS Forge
talk
(Thread)
OPC Really slow with Control RTE
Last updated: 2019-06-11
Control Win as Ethernet/IP master
CODESYS Forge
talk
(Thread)
Control Win as Ethernet/IP master
Last updated: 2022-09-06
codesys PN control --> S7-1516
CODESYS Forge
talk
(Thread)
codesys PN control --> S7-1516
Last updated: 2021-06-28
CoDeSys Control for Raspberry Pi
CODESYS Forge
talk
(Thread)
CoDeSys Control for Raspberry Pi
Last updated: 2020-01-31
stepper motor speed and position control
CODESYS Forge
talk
(Thread)
stepper motor speed and position control
Last updated: 2020-07-24
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.