Post by eksheep on Unit Tests and C007: Unknown Type CODESYS Forge talk (Post)
Hello, I am attempting to implement unit tests for my POUs. When building and running the unit tests I receive error C007: Unknown Type for all types defined in the library, Standard, 3.5.18.0. Which is included in the POU Library Manager. Any input would be appreciated. TIA.
Last updated: 2025-08-27

Post by sven01 on Documentation / Usage Help For Scripting Engine Libraries CODESYS Forge talk (Post)
Hi, I am still not able to figure out how to use the the classes and their functions. πŸ˜” Let's say I would like to use the function "importfile()" from the class "ScriptTextListObject.ScriptTextListMarker". I would be grateful for an additional example. Thanks! 😊
Last updated: 2023-08-21

Post by yannickasselin on MQTT QoS 1 & 2 CODESYS Forge talk (Post)
Anyone? Please? The Codesys documentation clearly states that QoS 1 & 2 are supported for Publisher and Subscriber. I really need to make this work for an important project. Thank you
Last updated: 2024-10-29

Post by arwie on Wish: CODESYSControl.cfg - again CODESYS Forge talk (Post)
Agree! Me and my customers are buying SL Licences from the store but we don't get proper documentation of the runtime! Only a few hints of the entries in CodesysControl.cfg are spread all over the Internet.
Last updated: 2024-11-26

Post by paulg on CODESYSControl_User.cfg - link to documentation? CODESYS Forge talk (Post)
Is there somewhere in the Codesys help files that generally details what configuration options are available for this file, and what details it logs regarding the configuration file? Or is that going to differ by libraries being used? Thanks!
Last updated: 2024-06-11

Post by gseidel on MC_Phasing state explenation CODESYS Forge talk (Post)
Hi kenth1973, it is not a matter of who created the function block. It is just that we don't have, and don't provide, documentation about internal implementation details... Hope you can understand that, Georg
Last updated: 2025-12-17

Post by lacypaige on Engineering Dissertation Help & Assignment Assistance. CODESYS Forge talk (Post)
This thread is for discussing engineering dissertation help, including research methods, choosing a topic, writing, and data analysis. Whether you need advice on structuring your dissertation, understanding industry trends, or solving research challenges, this is the place to ask questions and share ideas. Feel free to exchange tips, discuss best practices, and get support with engineering assignments and dissertations.
Last updated: 2025-03-19

Post by ralfki on PLC shell CODESYS Forge talk (Post)
Hello together, hopefully somebody could help me. I wanted to import a certificate to trusted folder using the plc shell (cert-import). Does somebody know how I can do it with the library CmpPLCShell Thank you for your support.
Last updated: 2024-11-20

Post by matt-purcell on Which Lib to use, connect to a socket with URL instead of IP address CODESYS Forge talk (Post)
I've been searching through these libraries, syssocket and net base services and they all seem to use the same structure for IP address for the connect function, SOCKADDRESS. At a glance, it doesn't look like that'll work, maybe it's just missing in the documentation somewhere?? I'm wondering if anyone has done it.
Last updated: 2024-06-17

Post by installwhat on Initialization of POUs (FB_Init) CODESYS Forge talk (Post)
Hi I was wondering if there's a pattern I can employ to acheive what you're doing but with a "reference to" and also allowing for online changes? Someone told me that the new beckhoff keeps references safe during online changes but all the documentation I've found suggests that's not the case. The easiest thing is to use fb_init for normal vars and pointers and references can be added in the function body every cycle and this allows for method calls after so far as I can tell.
Last updated: 2024-07-29

Post by ofey on EtherCAT fieldbus CODESYS Forge talk (Post)
Okey, thank you! Do you think it is something in this library, that makes it possible to do the configuration in a PRG? https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/IoDrvEtherCAT.html#id1 I think the codesys modbus libraries support configuration and connection to modbus slaves without having to add the slave devices in the device tree. Just do it from function blocks inside the program. I was hoping for something similar with EtherCAT.
Last updated: 2024-04-10

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by martinla on New Codesys Library Dependencies CODESYS Forge talk (Post)
When creating a new Codesys library, I am getting 2 errors for missing libraries. I can see that I am using newer versions of these in the library manager (3.5.17.0 and 3.5.19.0 opposed to 3.5.8.0 and 3.5.7.0 stated in the errors). IDE Version is V3.5 SP19 Patch 6. The "Download missing libraries..." button in Messages list is not doing anything. Why is it looking for older versions of these libraries? Can this be fixed by using the newer versions? How can I download & install the older version of these libraries?
Last updated: 2024-02-29

Post by installwhat on raspistepper error after install CODESYS Forge talk (Post)
I've had issues getting the raspistepper installed, all due to errors upon installation. The closest I get is the pictured error. The functions are in the sm3_shared library. I can add this library but that leaves 2 issues. I don't actually know, and I really want to understand this, why the required dependencies haven't been installed correctly. If I add the library it's only available with through the namespace. What can I do to both understand and resolve this? Thanks edit codesys 64 3.5.20.0 - same error on other versions too sm3 raspi stepper 0.0.0.5
Last updated: 2024-04-20

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
I have several libraries which contain values that should be saved on a PLC. As apparently no Persistent Variable List is available within Libraries, I use the Persistence Manager to create a Persistence Channel in the Project which imports the library. I then specify the persistence channel in the library using the {attribute 'ac_persist':='PersistenceChannel_CT'} specifier. This generally works very well and gives me exactly the properties I require. However, it came to my attention that the (alphabetially) first value from the library is not saved in the created ASCII file. When checking the content of the Persistence Channel, it shows all the variables as defined in the library. But the created file does not contain the first value and it is not restored after restart or reset. (see attached picture) I disabled Periodic Saving and set xSaveOnChange to TRUE and so the file usually updates immediately after changing one of the values. When changing the first value, it does not update which is consistent with this value not being saved. I also created a sample project and library from scratch which shows the same issue both using a Raspberry Pi and using a Linux machine. Does someone know what the reason for this could be or did someone make similar experiences? Looking forward to hearing your suggestions. Thanks in advance and best wishes Manuel
Last updated: 2023-10-17

Post by smartcoco on The text list provided outside the library is not available for visualization controls within the library. CODESYS Forge talk (Post)
I have a project called 'DemoProject' and a library called 'DemoLib'. Create a visual control named "DemoVisu" in the library, with a selection box of type "ComboBoxInteger" in the space. Now 'ComboBoxInteger' requires a 'Text list'. This "Text list" is provided when I call the "DemoVisu" control of the "DemoLib" library in "DemoProject". And this text list is in 'DemoProject'. I found that 'ComboBoxInteger' no longer works at this time. Other visual controls that use text lists also have this issue. I hope there is a good solution to this problem.
Last updated: 2023-10-16

Post by benediktenger on Access project information of references library by script CODESYS Forge talk (Post)
Hi, I need to accesss to project information of a referenced library in the project. At least I need the "Released" flag from these information to check that no project gets shipped with unreleased libraries. Unfortunally, I do not get this information by script. I archieved to get the library reference object and the managed library object but both won't give me this flag but only basic information like company, name, version, etc. Here is my code: # get the library refernces proj = projects.primary objects = proj.get_children(recursive=True) for object in objects: if object.is_libman: for libref in iter(object): if libref.is_placeholder and isinstance(libref.effective_resolution,str): print(libref) print(libref.name) # get the managed libraries libs = librarymanager.get_all_libraries() for lib in libs: print(lib.displayname) print(lib.version) Does somebody know how do get these information?
Last updated: 2023-10-23

Post by abrarsk on SysCom Library Usage CODESYS Forge talk (Post)
Hello all, I am facing issues with using SysCom library. With SysCom23 library things were simple but since we are migrating to 64bit systems, I am writing a Porting program. With SysCom23, opening the comport was as simple as providing the ComPort no. which returns the Handle as a DWORD. dwHandle:=SysComOpen(Port); But the new library is a bit different. It is asking for 2 input parameters to open the Com Port - Port Number and POINTER to RTS_IEC_RESULT IF hCom = 0 THEN hCom := SysComOpen(ComSettings.sPort, ADR(pResult)); How should I use the RTS_IEC_Result? I can find RTS_IEC-REUSLT under SysType2Interfaces of SysCom library. Also, can someone give me a general understanding of this RTS_IEC_REULT and RTS_IEC_HANDLE, etc.?
Last updated: 2024-08-05

Post by alexgooi on FB_INIT in library CODESYS Forge talk (Post)
Dear Forum, I currently have a challenge. I have a library with some communication classes. These communication classes need to be linked to an interface like this: Devices_and_controllers.Comm_Frame.Modbus_GVL_Link.KNX_TCP[Interface_Index] := THIS^; This is executed via a FB_Init() method. When I try to do this in a program this works fine. But when I declare the FB_Init() in the library the FB_Init() method is being called but the link is not made (interface still has the value 0000000000). The Objects and interfaces are defined in the library (GVL), so I’m assuming the data should be there. When I call the FB_Init method explicitly in the program it also works fine. Whys is this not working when it is all defined in the library? And is it even possible to create a structure like this in Codesys? Kind regards Alex
Last updated: 2024-05-22

Post by toffeebonbon on EL7041-0052 - does it run with EL7041 SoftMotion? CODESYS Forge talk (Post)
I let this project rest for a while and picked it up last week. I have been in contact with the support from beckhoff and got the information that the terminals were identical (communication wise). As the Log of the Axis (not the drive's log) shows the error when trying to write into the register 0x8012 and set the value for an encoder to a value that is the default - at least according to the manual - I was wondering if it is possible to "not write that value" to skip that part? Or am I misunderstanding the way the library communicates with the drive?