Search talk: Object reference not set to an instance of an object

 
<< < 1 .. 263 264 265 266 267 .. 293 > >> (Page 265 of 293)

Post by benemenn on OPC server in "Communication manager" CODESYS Forge talk (Post)
Same Issue here. If I understood correctly codesys plans to discontinue the classic SymbolConfigurations. But somehow, the CommunicationManager doesnt seem to support structures or arrays.
Last updated: 2025-03-31

Post by vincerex on SFTP access CODESYS Forge talk (Post)
hello everyone, is there a library or a way to access to SFTP server using Codesys? SysSocket library is only suitable for FTP it seems. I didn't find any other suggestion on the web Thanks for your help VinceReX
Last updated: 2025-04-01

Post by andrax on Variable Length Array - Cannot mix variable and fixed length dimensions? CODESYS Forge talk (Post)
Arrays with variable lengths are a bad idea. This makes your system unstable and can lead to crashes. Declare your array large enough to reserve enough memory
Last updated: 2025-05-24

Post by ph0010421 on Codesys running in Docker on Linux OS CODESYS Forge talk (Post)
Hello I need to make the Linux serial ports (ttymcx0, 1, 2 and 3) available to Codesys (Com1, 2...) Is there a guide? Is it something I do when I deploy the Codesys SL? thanks
Last updated: 2025-06-09

Post by milan-svarny on Redundancy problem - primary PLC suddenly goes to simulation state CODESYS Forge talk (Post)
Hi Ivanmaltar, please , did you solve the problem? i have the same case. Second PLC is going suddenly to Sim. state Thank you
Last updated: 2025-06-18

Post by ben1 on Login to Visu optional CODESYS Forge talk (Post)
It sounds like you are trying to use the device user management, but you can use the visu user management found in the Visu Manager for this.
Last updated: 2025-07-10

Post by wagokurt on CODESYS Visualization M License Fails to activate on Linux SL CODESYS Forge talk (Post)
I have successfully activated a CODESYS Control Performance M on a Linux IPC. When I try to activate the CODESYS Visualization M license it fails with this error. Any ideas? This is a WAGO 752-9401 FW4, running Debian 12.
Last updated: 2025-08-21

How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20? CODESYS Forge talk (Thread)
How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
Last updated: 2025-10-07

Using CoDeSys on Raspberry Pi to poll ModbusTCP slave data, and uplink by using LoRaWAN ATIM ACW-XB CODESYS Forge talk (Thread)
Using CoDeSys on Raspberry Pi to poll ModbusTCP slave data, and uplink by using LoRaWAN ATIM ACW-XB
Last updated: 2019-01-08

transfer Files from one controller to other controller on Canbus ( both controller are developed on codesys v3.5 CODESYS Forge talk (Thread)
transfer Files from one controller to other controller on Canbus ( both controller are developed on codesys v3.5
Last updated: 2017-07-17

Get Visu button position and size to open dialog via script depending on button location in screen CODESYS Forge talk (Thread)
Get Visu button position and size to open dialog via script depending on button location in screen
Last updated: 2020-10-26

I create python script Upload my script online to controller each time I get the password dialog CODESYS Forge talk (Thread)
I create python script Upload my script online to controller each time I get the password dialog
Last updated: 2020-09-25

Is there any way to remove the warning for having two enumerators with the same value in the same enum? CODESYS Forge talk (Thread)
Is there any way to remove the warning for having two enumerators with the same value in the same enum?
Last updated: 2016-12-22

Post by snhatton on Trace commands via Test Manager CODESYS Forge talk (Post)
One option could be to use a trigger variable to execute your trace and then toggle that variable from a step within a test case.
Last updated: 2023-12-08

Post by smartcoco on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
I have also been troubled by this issue for a long time, to the extent that I have to implement a recipe management library myself. Codesys version used: 3.5.19.40
Last updated: 2023-12-16

Post by giackanto on Eoe issues with Windows and Linux CODESYS Forge talk (Post)
Hi eschwellinger, I changed the name to tap2 due to network issues with Debian (I don't know why it changes the tap0 IP every time the program restarts). Anyway, I think the tap name doesn't affect the connection.
Last updated: 2023-12-20

Post by reinier-geers on Add licence CODESYS Forge talk (Post)
Hi I want to add a licence. I dont have the dongle jet. I tried a Stick. I dont see a Container. My Controler deliverer Dont put a motion licencens because its to expensive. How can i add a licensens?
Last updated: 2023-12-28

Post by marekxc on Little endian to Float from Modbus RTU CODESYS Forge talk (Post)
Maybe try going back to step one and: Var Reg1: WORD; Reg2: WORD; Reg12: DWORD; Value: REAL; end_var // program Reg1:= 4096; Reg2:= 14884; Reg12:= (reg2 * 65536) + reg1; Value:= DWORD_TO_REAL(Reg12);
Last updated: 2023-12-28

Post by reinier-geers on Power off CODESYS Forge talk (Post)
For power off i need to give a MC_Reset ???? Why ??? To power up i need MC_Power , but when i reset the inputs it doesnt power off the drive ! Why ? If i would use the controlword on ethercat it would. Why nog in MC ?
Last updated: 2024-01-12

Is it possible to use debug functions such as Step Execution while the PLC ladder is in Running? CODESYS Forge talk (Thread)
Is it possible to use debug functions such as Step Execution while the PLC ladder is in Running?
Last updated: 2024-01-16

Post by masmith1553 on C0564 Warning Message CODESYS Forge talk (Post)
Hello, After updating from SP18 to SP19 I am receiving multiple C0564 warning messages after I compile. Does anyone know how to fix the warnings?
Last updated: 2024-01-25

Post by jfd1981 on Ethernet/IP Issue CODESYS Forge talk (Post)
Hello all. I am trying to bring a stepper drive online, and it seems to be configured correctly, BUT I have the Orange triangle near it, and the diagnostic screen says "register session at the adapter"
Last updated: 2024-01-26

Post by eschwellinger on Access to the path *** is denied CODESYS Forge talk (Post)
sorry this is wrong here: (but important for signature problems) please update the CODESYS Installer to 2.2.1 version by downliad it from here: https://store.codesys.com/de/codesys-installer.html there is a problem on his auto update function. This will solve it!
Last updated: 2024-01-31

Post by saugat10 on Problem installing Multicore codesys control in raspberry pi 4 CODESYS Forge talk (Post)
I have Raspbian bullseye (32 bit) installed in my raspberry pi 4. I want to install codesys control multicore in my pi but the option is greyed out when i try to install it. Am i missing something?
Last updated: 2024-02-07

Post by goki on WAGO RS485 (753-652) on a 750-362 CODESYS Forge talk (Post)
Forgot to describe the pictures. Modbus1: is the actual configuration in codesys 3.5 Modbus2: is the config in WAGO I/O Modbus3: is the configuration from the old one with Beckhoff twincat (we are changing from Beckhoff to wago and codesys)
Last updated: 2024-02-08