Post by dhumphries on How to determine code size
CODESYS Forge
talk
(Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05
Post by rafaelbrito on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
CODESYS Forge
talk
(Post)
When trying to use the Visualization ToolBox, no objects appear and the following error appears. Could you tell me what this error could be? The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. Can anyone tell me what this error is?
Last updated: 2024-12-03
Post by sturmghost on Mimic behavior of the visualization button element with a custom button
CODESYS Forge
talk
(Post)
Im wondering how Codesys is doing the mouse event capturing with their visualization button element? If you add such a button without configuring any input configuration event (like OnMouseDown) or button state variable and then click on the button, the button changes to the visual pressed state and back if you release the button (so they must react to an OnMouseDown event). But how? If I try to mimic this behavior with my custom button visualization element (like a basic rectangle) I need to use an input configuration event to change the color of the button (to make it look like the button was pressed on OnMouseDown event). When I try to add this button via a Frame-Element to my main visualization page I'm unable to use an input configuration event on the Frame-Element because the input configuration event on the button element won't be evaluated anymore (it seems like you can't stack input fields, e.g. invisible input elements, onto each other). Hence the button is not shown pressed anymore. How they do it?
Last updated: 2024-08-04
Post by anderson on function block output
CODESYS Forge
talk
(Post)
so it is not possible for me to use the function blocks and through them I can select the digital outputs of the PLC so that pulses and direction are output, or some function block that does this reading and in it I can program the pulse and direction outputs for the drive?
Last updated: 2024-01-09
Post by scarter on Import/Export PLCOpen xml Task Configuration
CODESYS Forge
talk
(Post)
I'm Having the same issue. If I highlight PLC Logic and import it erases everything else and replaces the Task config. If I highlight the Application I get the same result. Simple manual fix is click and drag the task config onto the origional Application, and delete the second one. Easy fix but not the expected result of importing task config.
Last updated: 2024-01-17
Post by rmaas on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia
CODESYS Forge
talk
(Post)
Hi, Im not sure if this is what you mean, but i do succesfully use the IoDrvEthercatLib.ETCSlave.InputData and IoDrvEthercatLib.ETCSlave.OutputData to read from and write to beckhoff DI and DO cards. Very convenient as you can make an FB with an VAR_IN_OUT of type IoDrvEthercatLib.ETCSlave and only have to pass the slave reference... So i am not using .ETCSlave_Diag but .ETCSlave...
Last updated: 2024-02-13
Post by matthew on Persistence Manager Backup
CODESYS Forge
talk
(Post)
Hi @eschwellinger yes I have been using xDoubleStorage It happened again and I checked and the files were still there with there contents, restarting codesys or rebooting would not even reload them. Doing a download and then starting the PLC loaded them and began working again. Some sort of mismatch error or something?
Last updated: 2024-05-14
Post by tk096 on Motion FB Error
CODESYS Forge
talk
(Post)
Hi, Softmotion Robotics does not support tracking in/out to dynamic coordinate systems with relative movements. Is MC_MoveLinearAbsolute an option? See SMC_RELATIVE_MOVEMENT_TRACKING_CS in https://content.helpme-codesys.com/en/libs/SM3_Error/Current/SM3_Error/SMC_ERROR.html Concerning the other error: Do you use any motion function blocks of SM3_Basic to move a single axis of the robot in your application?
Last updated: 2023-10-20
Post by programmierer on Implementing UDP Communication
CODESYS Forge
talk
(Post)
Hello everyone, I hope you can help me with my problem. I am new to programming and am currently working with a WAGO controller in our lab, which controls a heat pump. My goal is to send the electrical power of the heat pump (Pel_WP) via a UDP connection to a specific IP address. I am using Codesys version 2.3 and following the guide I found here: https://forge.codesys.com/forum/de/396/genmed-Konfiguration%20der%20UDP%20Kommunikation%20Cosesys%20S7.pdf. I have adapted the guide to suit my needs. The data sending works since I can force the reception value Pel_WP and the data is sent accordingly. However, I am having trouble with the receiving part. The reception value is not being correctly received, and the diSocket variable shows -1. The connection between the heat pump and the WAGO controller seems to be set up correctly, as the heat pump is listed under the communication parameters with the correct IP address. I have also attached images to provide a better view of the setup. I would greatly appreciate any support or suggestions for a solution. Thank you in advance!
Last updated: 2024-08-02
Post by callumo1 on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
Thanks for the reply. I want to be able to check if any dialogs are open of any name. I already have a function similar to what you have send but I don't want to have to run it for all the different dialog names. Thanks
Last updated: 2023-09-26
Post by stiller on OPC UA RPI 4.8.0.0 Status Code / "out of range"
CODESYS Forge
talk
(Post)
Hello, I have an OPC-UA server with an information model. For many values, there is a defined range (e.g., 0 to 100). If a client enters a value outside this range (e.g., 120), the StatusCode should change to Bad. How can I accomplish this? Any help is appreciated! Thank you in advance. Best regards, Christian Stiller
Last updated: 2024-07-10
Post by reinier-geers on Energie price
CODESYS Forge
talk
(Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03
Post by reinier-geers on Energie price
CODESYS Forge
talk
(Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03
Post by pietrobalint on Retain / Persistent Variables in Codesys for Raspberry Pi
CODESYS Forge
talk
(Post)
I made hardware reboot and it still not working. I also tried Persistence Manager which need Application Composer Single License but Codesys support said that my runtime do not compatibile with it and it will avaiable in 2025 only. So I hope I will figured out how to use this code.
Last updated: 2024-08-31
Post by thewizard8 on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi All, I finally figured out how to solve it. The only away that I got it to work was to define parity to None on modbus configuration, and now works like a charm. Just for the record I'm using the GPIO port pins (8,10) and a RS485 to ttl shield that you can find online. Thanks all for the support! Regards Ricardo
Last updated: 2024-03-19
Post by martinlithlith on Relay board / relays for raspberry pi 3 b+
CODESYS Forge
talk
(Post)
hi! im planning a project on a raspberry with Codesys. For this I'll need a number of relays to control heating and fans, all a max of 24v and about 2a. How would i know if the board / relays i buy will be working with Codesys? Does every hat work or does it need a library/driver? is there a list of drivers/libraries created? as this is a hobby project all tips on a relay board or single boards that works with codesys and not to expensive are very welcome.
Last updated: 2023-09-03
Post by mmoncada on Dinamically loading recipes
CODESYS Forge
talk
(Post)
I'm having trouble with the initial loading of recipes. I can create them and load one or the other, but when the program restarts the recipes are not listed. I'm calling: RecipeManCommands.ReloadRecipes and then RecipeManCommands.GetRecipeCount which returns 0 recipes. None of the methods returns error and if i call them again after RecipeManCommands.CreateRecipe RecipeManCommands.ReadAndSaveRecipe getRecipeCount returns the number of recipes created. When i restart the system, once again they are not listed even though the recipe files are there. Any ideas? Martin Btw, Codesys 3.5 SP 16 Path 9
Last updated: 2023-12-06
Post by hismoon on Inheritence of struct,
CODESYS Forge
talk
(Post)
Using a UNION instead of a STRUCT alone should give you that flexibility and only occupy memory once. And if you want to be really elegant, you could use an FB, which only holds PUBLIC VAR. Because a POU can use "EXTENDS"/inheritance. In CODESYS V3, an FB has a lot in common with C++ classes. Using ANY or ALIAS is rarely a good idea. It neither won't be pretty, nor have good readability and requires you to create a lot of error-prone things around it.
Last updated: 2025-03-14
Post by installwhat on Ethercat and profinet on together
CODESYS Forge
talk
(Post)
I'm curious about the impact of having profinet and Ethercat (specifically softmotion so frame at start of task?) running together. Since it's advised to access the data from the bus task should have both profinet io and ethercat on the same task? Are there any implications around this one should be aware of especially since the frame at task start is just, so far as I'm aware, an ethercat thing? Thanks
Last updated: 2025-04-08
Post by eschwellinger on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore
CODESYS Forge
talk
(Post)
1) https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html -> SL: Restrictions The combination of Raspberry Pi and a CODESYS Runtime is for private use, test and teaching purposes. Commercial use is not permitted. 2) you could switch between them by /etc/codesyscontrol/CODESYSControl_User.cfg [CmpRasPi] Architecture=armv7l for MC: armv7l for SC: armv6l for 64Bit: aarch64 or in the Deploytool:
Last updated: 2025-08-06
Post by timvh on I want to show the current recipe name in the visualization screen
CODESYS Forge
talk
(Post)
Maybe the easiest solution for you is to add one STRING variable to your recipe and enter the name of the recipe in variable value. This is little bit double the work (naming the recipe and entering the value of the STRING variable), but in that case you always have the current value of the variable which you can read from the application and show in the visualization.
Last updated: 2025-09-04
Post by dominggus on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
I still have the same problem even when updating to CODESYS Recipes 4.3.0.0. My scenario: I'm trying to save/load an array of structs using the Visu: - Execute Command > "SaveRecipeAs" works properly - Execute Command > "LoadWriteRecipe" works not entirely: the structs of array[6] and array[7] should have been empty but were duplicates of array[4] and array[5]... the struct contains 26 variables and the array's length is 30.. Maybe there is a upper limit on recipe variable count?
Last updated: 2024-03-02
Post by andy-yemm on Assertion Failed
CODESYS Forge
talk
(Post)
I had similar assertion failed error messages today. I am fairly new to Codesys. I tried using SFC for the first time, I usually use ST. Anyway I had errors in some of my transitions. I copied and pasted transition code and forgot to change the target of the code. I started getting lots of the assertion errors but now I have sorted out the problems and it compiles OK the assertion error messages seem to have stopped. There do not seem to be any other responses to your post, did you resolve your problem?
Last updated: 2024-03-19
Post by riccardo on VisuElems.CurrentUserGroupId is not stable
CODESYS Forge
talk
(Post)
Goodmorning TimvH, Thanks for the reply. I don't know if your solution solve my trouble yet, I am going to see the link you sent me. In the mean time I try to explane better what I need to do. I have a turbine system that get in alarm under some condition (E.g low speed of turbine) and block the itself. When the system is stoped there is no speed turbine and the system cannot start. To give to the operetor the possibility to bypass the alarms, there is an acknoledgement alarm pushbutton. This bypass must not work for everyone but only for those client that perform the login by (User Management). Furthermore, if the user perform the (manual or automatic) logout in alarm conditions, the acknowlegment must be annulled and block the system again. To do this, I need to know if an operator is logged in the page and is working to fix the problem; otherwise the syste must autoturn off again. Now I go to study your solution, if I have explaned better and you have another idea tell me please.
Last updated: 2023-11-16
Post by abinvest579 on TCP Client
CODESYS Forge
talk
(Post)
Hi All, I am using codesys based plc to read and control magna power DC supply over LXI protocol using SCPI command. To connect device required socket programming for that i am using Net base service library function block TCP_Client to establish connection over TCP/IP , TCP_Write to write SCPI commands and TCP_Read to read data from Magna power DC supply. I have attached screenshot for logic developed. I am able to connect and write commands to device but i not receiving any information from device. For writing Commands i also tried various end of line character like \n,<nl>, A, D, 10, 13, 0x0A, 0x0D but not received any status from device. For testing purpose i am using simple command '*IDN?' to read data. Also if tried to check on hercules software what data actually plc read, first it read correct data after that is read wrong data as see in screen shot. 'Hello World' was correct read and after that Codesys in replaced with 'Codesysorld' that is not correct way. Same issue also appeared for send data. Any one have face same issue how i can read data directly from device correctly and send data please suggest solution on this.</nl>