Search talk: Support client animations and overlay of native elements

 
<< < 1 .. 32 33 34 35 36 .. 219 > >> (Page 34 of 219)

Post by bertus on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Hello all, I am trying to run a XY trajectory from a static G-Code file. Everything works except the smoothing/blending of the corners. My setup: Codesys v3.5sp18 Raspberry Pi 4 CODESYS Control for Raspberry Pi SL, using demo license. Zero axes (only using the interpolator). The order of processing for my decoding is: SMC_NCDecoder (ok) SMC_SmoothMerge (ok) SMC_SmoothPath (not ok) SMC_LimitDynamics SMC_CheckVelocities I created following instances and buffers: fbNCDecoder: SMC_NCDecoder; fbSmoothMerge: SMC_SmoothMerge; fbSmoothPath: SMC_SmoothPath; fbLimitDynamics: SMC_LimitDynamics; fbCheckVelocities: SMC_CheckVelocities; aNCDecoderBuffer: ARRAY[0..49] OF SMC_GeoInfo; // buffer stage 1 (fbNCDecoder) aSmoothMergeBuffer: ARRAY[0..19] OF SMC_GeoInfo; // buffer stage 2 (fbSmoothMerge) aSmoothPathBuffer: ARRAY[0..99] OF SMC_GeoInfo; // buffer stage 3 (fbSmoothPath) aLimitDynamicsBuffer: ARRAY[0..39] OF SMC_GeoInfo; // buffer stage 4 (fbLimitDynamics) My original G-Code file has a lot of short G1 elements but this example, I reduced it to a simple square: N000 G51 D10 N010 G38 O1 N020 G00 X0 Y0 F50 E1000 E-1000 N030 G01 X0 Y-37.5 N040 G01 X-75 Y-37.5 N050 G01 X-75 Y37.5 N060 G01 X0 Y37.5 N070 G01 X0 Y0 N080 G50 N090 G39 O1 In the Codesys CNC settings, I have these instances activated: SMC_SmoothMerge SMC_SmoothPath SMC_LimitDynamics SMC_CheckVelocities And with those settings (and the path-preprocessing button actived), the G-Code viewer shows the square with nicely blended corners (see attached picture). However, when running it on the PLC, it doesn't blend the corners at all. Below the relevant part of my code. The process is started with bDecode. // stage 1: decoding G-code fbNCDecoder( ncprog := square, bExecute:= bDecode, bAbort:= NOT bDecode, nSizeOutQueue := SIZEOF(aNCDecoderBuffer), pbyBufferOutQueue := ADR(aNCDecoderBuffer) ); // stage 2: merge short linear segments fbSmoothMerge( bExecute := bDecode, poqDataIn := fbNCDecoder.poqDataOut, nSizeOutQueue := SIZEOF(aSmoothMergeBuffer), pbyBufferOutQueue := ADR(aSmoothMergeBuffer), piMaxDifference := PI_MAX_DIFFERENCE, usiMaxDegree := 5, wFeatureFlag := 1, wAdditionalParamNumber := 0, dMinimumCurvatureRadius := D_MIN_CURVATURE_RADIUS ); // stage 3: smooth corners fbSmoothPath( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothMerge.poqDataOut, eMode := SMC_SMOOTHPATHMODE.SP_SPLINE5_MIN_CURVATURE, eAddAxMode := SMC_SMOOTHPATHADDAXMODE.SPAA_NONE, nSizeOutQueue := SIZEOF(aSmoothPathBuffer), pbyBufferOutQueue := ADR(aSmoothPathBuffer), dAngleTol := D_ANGLE_TOL, bSymmetricalDistances := TRUE, bImprovedSymmetricCuts := TRUE ); // stage 4: keep acc/dec and velocity within limits fbLimitDynamics( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothPath.poqDataOut, wAxis := 16#07, nSizeOutQueue := SIZEOF(aLimitDynamicsBuffer), pbyBufferOutQueue := ADR(aLimitDynamicsBuffer), bIncludePathSettings := TRUE, dMaxVel := 2500, dMaxAccDec := 10000 ); // stage 5: check the path speed fbCheckVelocities( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbLimitDynamics.poqDataOut, dAngleTol := D_ANGLE_TOL); pathQueue := fbCheckVelocities.poqDataOut; // repeat until MaxDuration ... Any idea what I'm doing wrong? Is smooth path supposed to work at all when using a demo license? Thanks.
Last updated: 2025-12-17

Post by timvh on How to implement an interface (IElement)? CODESYS Forge talk (Post)
See: https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ This contains an application "OnlineChangeSafeLinkedListExample". What you should do is create a new interface which has your "Priority" property. Then your FB should extend the base element function block and implement your own interface: E.g. FUNCTION_BLOCK MyElement EXTENDS COL.LinkedListElementBase IMPLEMENTS I_MyInterface Then the __QUERYINTERFACE does the magic to check if your "element" also implements your interface. Something like this: // Compares this element with itfElement. // Returns 0 if the elements are equal, < 0 if the element is less than itfElement, // > 0 if the element is greater than itfElement. // This method will be called from sorted collections (e.g. |COL.SortedList|) to sort the elements. // IMPORTANT: The underlying value to be compared with MUST NOT be changed during the lifecycle of the object. METHOD ElementCompareTo : INT VAR_INPUT (* The element to compare*) itfElement : COL.IElement; END_VAR VAR itfIntElement : I_MyInterface; xResult : BOOL; END_VAR // We use integer iInt1 for sorting. xResult := __QUERYINTERFACE(itfElement, itfIntElement); IF xResult THEN IF iInt1 < itfIntElement.Priority THEN ElementCompareTo := -1; ELSIF iInt1 > itfIntElement.Priority THEN ElementCompareTo := 1; ELSE ElementCompareTo := 0; END_IF ELSE ElementCompareTo := -1; END_IF
Last updated: 2024-07-22

Post by climblinne on Calling OPC UA Methods from UaExpert CODESYS Forge talk (Post)
Hello, I hope someone could help me. I installed the newest Codesys 3.5 SP 20 Patch 1. When loading the demo files from @i-campbell I can upgrade them to the latest version and everthing works on the OPC-UA client side as expected (object "a" is visible, I can use the "ExampleMethod"). Now I * remove the "Information Model", * delete the "OPC_UA_Symbols Objects", * Add "Information Model" again * add "TestRootObjectType" again and "Generate IEC declarations" * and search for mapped instances (to get instance "a" again) Very good still working as expected. Now I delete the OPC_UA_Symbols and add it again referring to the "objecttest" from 16.9.2020. Also I redo the steps from above. The result is now, that I can't see the "a" object in the "Root/Objects" folder. Why ist this and how can I make it running? I think, it could may be a different version of the UA configuration file. I tried to build my own model definition files and got the same problem (but I am really not an expert). When someone has a actual model, which is also running in the actual Codesys I would be very grateful. Or even better, how to make the correct model in e.g. UA Modeler SW (I followed the description https://documentation.unified-automation.com/uamodeler/1.6.0/html/howprojnet_sec.html).
Last updated: 2024-07-01

Post by leandroct on Creating Boot Application not working CODESYS Forge talk (Post)
I have a Control Win V3.5 SP20 (64-bit) application, and until now, I open the program (with a password) and download it. However, I need to give the client the option to install the program on the Controller, without them having to open it and access the code. So, I followed these steps: 1 – In the Online => Create Boot Application menu, I saved the generated files in a directory: Application.app Application.crc PlcLogic\visu\ directory with several files 2 – In the SysTray, I ran the PLC, and it created a directory. In the root of this directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E84889DB), I pasted Application.app and Application.crc. Since it created a \visu directory, I pasted the PlcLogic\visu\ files generated in Create Boot Application into it. 3 - In the general Codesys directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64), I edited CodesysControl.cfg, adding: [CmpLog] Application.1=Application 4 - When running the PLC, nothing happens and the TargetVisu screen does not open. What I'm doing wrong?
Last updated: 2025-09-03

Post by abauza on Image Pool using in other libraries CODESYS Forge talk (Post)
Hi im Albert, im developing libraries for my PLCs and i have some issues on visualization part. First of all I have done a library that have a image pool with a list of 4 gifs "ImagePoolErrors" (i've tested in other projects and it works) but the problem comes when i create another library that in the visualization part contains images from my image pool library, when i simulate a program that includes a instance of my second library object the visualization images dont show, any of them, i've checked all the references and tried some options of the image properties but without any difference. Here is the screenshots of the first library (that contains Image Pool) and the second library (that includes images of the image pool first library) and the visualization simulation (with the missing image gif issue). Any idea of what i forgotten in the process? If you need any detail of the library or of the project or you need the library file, ask me, thank on advance
Last updated: 2024-08-19

Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS) CODESYS Forge talk (Post)
Thanks So Much for the reply! Were using the Weidmuller UV66-ADV-10-CAP-W The HMI is pointed to the URL which is assigned through u-OS. Basically when you log into the controller's webserver via browser you can view the installed apps. One of which is the Codesys runtime. When you click on that it takes you to the visualization. That corresponding url is what the HMI is looking for. I apologize I don't have that on hand as I'm in the office right now. I don't think I tried connecting using the port you mentioned and https in lieu of the u_OS URL. I can certainly try. Out of the box the u-OS is set for HTTP. Since we're isolated I havent changed that yet. When this has happened while logged on via chrome on my laptop, simply refreshing brings the visualization right back. In the case of the HMI in kiosk mode, we power cycle the HMI to force a reconnect, log back in u-OS and the visualization is back.
Last updated: 2023-09-06

Post by jegerjon on Testing of Codesys program CODESYS Forge talk (Post)
I have a simulation function that toggle xSimActive. I map all IO variables to "IO GVLs" when xSimActive=0. I map IO corresponding SimIO GVL to "IO GVLs" when xSimActive=1. Then I write code for the simulation program that runs when xSimActive=1. Typically increase flow corresponding to pump speed, simulate tankfilling corresponding to flow and so on. I made a FC that require a correct code to activate simulation to avoid unintended activation by service dept. When comissioned remove any possibility to activate simulation. Super when officetesting and supporting service dept. + cheap as it requires no additional equipment, and it is easier to support customer later on in the life cycle as you can test proposed changes without setting up a testlab.
Last updated: 2023-12-07

Post by jegerjon on Testing of Codesys program CODESYS Forge talk (Post)
I have a simulation function that toggle xSimActive. I map all IO variables to "IO GVLs" when xSimActive=0. I map IO corresponding SimIO GVL to "IO GVLs" when xSimActive=1. Then I write code for the simulation program that runs when xSimActive=1. Typically increase flow corresponding to pump speed, simulate tankfilling corresponding to flow and so on. I made a FC that require a correct code to activate simulation to avoid unintended activation by service dept. When comissioned remove any possibility to activate simulation. Super when officetesting and supporting service dept. + cheap as it requires no additional equipment, and it is easier to support customer later on in the life cycle as you can test proposed changes without setting up a testlab.
Last updated: 2023-12-07

Post by toffeebonbon on EL7041-0052 - does it run with EL7041 SoftMotion? CODESYS Forge talk (Post)
I let this project rest for a while and picked it up last week. I have been in contact with the support from beckhoff and got the information that the terminals were identical (communication wise). As the Log of the Axis (not the drive's log) shows the error when trying to write into the register 0x8012 and set the value for an encoder to a value that is the default - at least according to the manual - I was wondering if it is possible to "not write that value" to skip that part? Or am I misunderstanding the way the library communicates with the drive?
Last updated: 2024-07-24

Post by jshirazi on Restore license on Raspberry Pi CODESYS Forge talk (Post)
Hi, I recently got a license for Raspberry Pi, after license activation I made a backup copy of "CMLicenseNew.WibuCmRaU" file to a safe place. Things got complicated and I tried to downgrade OS for some reason after that I tried several times/ways to restore my license with no luck. the specifications are as follows: Raspberry Pi 4 Model B Rev 1.1 codesyscontrol 4.10.0.0 SDK 3.5.19.30 Logs: **** ERROR: CodeMWriteLicenseFile: 'CMLicenseNew.WibuCmRaU' failed: Container not found or Server dose not support .... So if someone know a solution for this please kindly help me. Regards
Last updated: 2024-02-03

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I checked it using the very same docker container version like colleague moon and the command returned root@nt0001c02c5533:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. Result: 0 CmContainer(s) listed. (CodeMeter not running) Please consider that we intend to license a codesys ARM64 SL in a docker container.
Last updated: 2024-03-20

Post by denizerm on Deploy Control SL cant find Podman CODESYS Forge talk (Post)
Hello, CODESYS seems to have problems finding the container engine. In the "Deploy Control SL" window, after connecting via ssh, it simply says: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.4.199) [WARNING] Error detecting container architecture running podman info yields normal results. My podman info output is as follows: home/Admin$ podman info host: arch: amd64 buildahVersion: 1.35.3 cgroupControllers: - cpu - memory - pids cgroupManager: systemd cgroupVersion: v2 conmon: package: Unknown path: /usr/bin/conmon version: 'conmon version 2.1.10, commit: affab49967eb62f75d2a47398344ab053326289f' cpuUtilization: idlePercent: 99.36 systemPercent: 0.3 userPercent: 0.34 cpus: 4 databaseBackend: sqlite distribution: codename: scarthgap distribution: redagv version: 1.0.0 eventLogger: journald freeLocks: 2040 hostname: secure-automation-os idMappings: gidmap: - container_id: 0 host_id: 1000 size: 1 - container_id: 1 host_id: 100000 size: 65536 uidmap: - container_id: 0 host_id: 1100 size: 1 - container_id: 1 host_id: 100000 size: 65536 kernel: 6.6.65-intel-pk-standard linkmode: dynamic logDriver: journald memFree: 6115598336 memTotal: 8086278144 networkBackend: cni networkBackendInfo: backend: cni dns: {} ociRuntime: name: crun package: Unknown path: /usr/bin/crun version: |- crun version 1.14.3.0.0.0.8-89d44-dirty commit: 89d44467e3b410b73f2065756a12789be45b855b rundir: /run/user/1100/crun spec: 1.0.0 +SYSTEMD +SELINUX +APPARMOR +CAP +SECCOMP +EBPF +YAJL os: linux pasta: executable: /usr/bin/pasta package: Unknown version: "" remoteSocket: exists: true path: /run/podman-shared/podman.sock security: apparmorEnabled: false capabilities: CAP_CHOWN,CAP_DAC_OVERRIDE,CAP_FOWNER,CAP_FSETID,CAP_KILL,CAP_NET_BIND_SERVICE,CAP_SETFCAP,CAP_SETGID,CAP_SETPCAP,CAP_SETUID,CAP_SYS_CHROOT rootless: true seccompEnabled: true seccompProfilePath: "" selinuxEnabled: false serviceIsRemote: true slirp4netns: executable: /usr/bin/slirp4netns package: Unknown version: |- slirp4netns version 1.2.0-beta.0+dev commit: unknown libslirp: 4.7.0 SLIRP_CONFIG_VERSION_MAX: 4 libseccomp: 2.5.5 swapFree: 0 swapTotal: 0 uptime: 1h 36m 10.00s (Approximately 0.04 days) variant: "" plugins: authorization: null log: - k8s-file - none - passthrough - journald network: - bridge - macvlan - ipvlan volume: - local registries: localhost:5000: Blocked: false Insecure: true Location: localhost:5000 MirrorByDigestOnly: false Mirrors: null Prefix: localhost:5000 PullFromMirror: "" search: - localhost store: configFile: /home/serviceuser/.config/containers/storage.conf containerStore: number: 2 paused: 0 running: 2 stopped: 0 graphDriverName: overlay graphOptions: {} graphRoot: /data/containerfiles graphRootAllocated: 119952025600 graphRootUsed: 13801246720 graphStatus: Backing Filesystem: extfs Native Overlay Diff: "true" Supports d_type: "true" Supports shifting: "false" Supports volatile: "true" Using metacopy: "false" imageCopyTmpDir: /var/tmp imageStore: number: 4 runRoot: /run/user/1100/containers transientStore: false volumePath: /data/containerfiles/volumes version: APIVersion: 5.0.2-dev Built: 1711987427 BuiltTime: Mon Apr 1 16:03:47 2024 GitCommit: bb81e85a430fa95d23a15b77c717fd68bf06ebf2 GoVersion: go1.22.12 Os: linux
Last updated: 2025-10-22

Post by wbj0t on Raspberry Pi CM4. CoDeSyS files corrupted after hard reset. CODESYS Forge talk (Post)
Hello everyone. Raspberry Pi CM4 after some 1 week of work was hard reset mannualy several times and after these hard resets User Management file was missed (when click login button, enter login/password, error: User Management File missed). Also programm can not open file via SysFile library, but this file exists and size of him is 0 bytes, but must be more any way (I keep some kind of archive via this lib). What happens, how files corrupted? Where do I need try to find this error of the codesys or system whole? In the log files of codesys nothing interesting about this happens. Thanks for reading Is this enough hold PlcLogic and SysFileMap.cfg as reserve copy in another place for restoring the programm? And how automate restoring actions if programm files corrupted?
Last updated: 2024-09-16

Post by pernockham on How to manage soft container licenses for (remote) multi units? CODESYS Forge talk (Post)
Using Codesys runtime for Linux and thinking of the process of preparing multiple such systems for my customer. I don't necessarily have physical access to these units, they can be (very) remote. The idea so far is to use an image to install the Linux OS and codesys runtime. Application updates can be done by distribution of the PlcLogic/Application/application.app and application.crc files. But whats the most practical way of managing the license for these units? Do each controller need to be physically connected to a License Manager instance or can licenses be distributed by means of a license file for each unit? I believe that the license should be stored in soft containers for each unit. Help and insights appreciated! Per
Last updated: 2025-04-04

Post by forest on SM Drive license error CODESYS Forge talk (Post)
Hi, when it comes about license, I used INVTmatic Studio, which uses Codesys, for programming INVT plc. I bought Codesys Modbus license, it was not expensive, and then realised that INVT didn't have License Manager option (greyed out in program) which is needed for using of Codesys License. I contacted support from INVT, but developers told me that option is still not available. So depending on environment for programming Codesys, you can or not use Modbus license. Good thing about this version of Modbus TCP it works both direction. I could send commands and receive feedbacks from drive. But communication stops after 30 mins. So I used simple version of ethernet modbus which is somewhere in INVT or Condesys library (I can check tomorrow) which works only one way. I could send cmd to drive, and control it, but didn't have any feedback, like some readings back in PLC. which is bad, but at least I could start it and it didn't fail after 30 mins.
Last updated: 2024-01-10

Post by niloufar on Execution Order of Function Blocks CODESYS Forge talk (Post)
Hi, Our program incorporates various function blocks and programs written in different languages such as St and SFC. They implement numerous actions and methods using different languages from their function blocks. My question is whether the execution order of function blocks is associated with the programming languages used. I understand that cycle time can be configured in the task configuration, but I'm curious if there is a specific sequence order of execution for function blocks written in different languages. For example, all function blocks in (ST) are executed first, followed by the execution of (SFC). Specifically, when the function is written in (ST) and the action is implemented in (SFC). I modified all function blocks in the main PLC program and configured a task configuration for the main program.
Last updated: 2023-12-13

Post by dhumphries on How to determine code size CODESYS Forge talk (Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05

Post by rafaelbrito on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. CODESYS Forge talk (Post)
When trying to use the Visualization ToolBox, no objects appear and the following error appears. Could you tell me what this error could be? The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. Can anyone tell me what this error is?
Last updated: 2024-12-03

Post by sturmghost on Mimic behavior of the visualization button element with a custom button CODESYS Forge talk (Post)
Im wondering how Codesys is doing the mouse event capturing with their visualization button element? If you add such a button without configuring any input configuration event (like OnMouseDown) or button state variable and then click on the button, the button changes to the visual pressed state and back if you release the button (so they must react to an OnMouseDown event). But how? If I try to mimic this behavior with my custom button visualization element (like a basic rectangle) I need to use an input configuration event to change the color of the button (to make it look like the button was pressed on OnMouseDown event). When I try to add this button via a Frame-Element to my main visualization page I'm unable to use an input configuration event on the Frame-Element because the input configuration event on the button element won't be evaluated anymore (it seems like you can't stack input fields, e.g. invisible input elements, onto each other). Hence the button is not shown pressed anymore. How they do it?
Last updated: 2024-08-04

Post by anderson on function block output CODESYS Forge talk (Post)
so it is not possible for me to use the function blocks and through them I can select the digital outputs of the PLC so that pulses and direction are output, or some function block that does this reading and in it I can program the pulse and direction outputs for the drive?
Last updated: 2024-01-09

Post by scarter on Import/Export PLCOpen xml Task Configuration CODESYS Forge talk (Post)
I'm Having the same issue. If I highlight PLC Logic and import it erases everything else and replaces the Task config. If I highlight the Application I get the same result. Simple manual fix is click and drag the task config onto the origional Application, and delete the second one. Easy fix but not the expected result of importing task config.
Last updated: 2024-01-17

Post by rmaas on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia CODESYS Forge talk (Post)
Hi, Im not sure if this is what you mean, but i do succesfully use the IoDrvEthercatLib.ETCSlave.InputData and IoDrvEthercatLib.ETCSlave.OutputData to read from and write to beckhoff DI and DO cards. Very convenient as you can make an FB with an VAR_IN_OUT of type IoDrvEthercatLib.ETCSlave and only have to pass the slave reference... So i am not using .ETCSlave_Diag but .ETCSlave...
Last updated: 2024-02-13

Post by matthew on Persistence Manager Backup CODESYS Forge talk (Post)
Hi @eschwellinger yes I have been using xDoubleStorage It happened again and I checked and the files were still there with there contents, restarting codesys or rebooting would not even reload them. Doing a download and then starting the PLC loaded them and began working again. Some sort of mismatch error or something?
Last updated: 2024-05-14

Post by tk096 on Motion FB Error CODESYS Forge talk (Post)
Hi, Softmotion Robotics does not support tracking in/out to dynamic coordinate systems with relative movements. Is MC_MoveLinearAbsolute an option? See SMC_RELATIVE_MOVEMENT_TRACKING_CS in https://content.helpme-codesys.com/en/libs/SM3_Error/Current/SM3_Error/SMC_ERROR.html Concerning the other error: Do you use any motion function blocks of SM3_Basic to move a single axis of the robot in your application?
Last updated: 2023-10-20

Post by programmierer on Implementing UDP Communication CODESYS Forge talk (Post)
Hello everyone, I hope you can help me with my problem. I am new to programming and am currently working with a WAGO controller in our lab, which controls a heat pump. My goal is to send the electrical power of the heat pump (Pel_WP) via a UDP connection to a specific IP address. I am using Codesys version 2.3 and following the guide I found here: https://forge.codesys.com/forum/de/396/genmed-Konfiguration%20der%20UDP%20Kommunikation%20Cosesys%20S7.pdf. I have adapted the guide to suit my needs. The data sending works since I can force the reception value Pel_WP and the data is sent accordingly. However, I am having trouble with the receiving part. The reception value is not being correctly received, and the diSocket variable shows -1. The connection between the heat pump and the WAGO controller seems to be set up correctly, as the heat pump is listed under the communication parameters with the correct IP address. I have also attached images to provide a better view of the setup. I would greatly appreciate any support or suggestions for a solution. Thank you in advance!
Last updated: 2024-08-02

<< < 1 .. 32 33 34 35 36 .. 219 > >> (Page 34 of 219)

Showing results of 5462

Sort by relevance or date