Post by eschwellinger on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
for the package you net to install 32bit support(to have the native timprovider availble to deploy) sudo apt-get install libc6:i386 Then native Safeplc and native Safetimeprovider should be available to install. Raspi yes - but there is no official package available till now and you need have a rt_preemt patched kernel on the Pi, then it works like charm
Last updated: 2025-11-18
Post by rafaelbrito on Integration C Code
CODESYS Forge
talk
(Post)
I tried to use C code in the library that I have been developing in the project, but without success. I tried to use the CODESYS Control SL Extension Package to generate XXXdep.h and XXXltf.h, but without success. Do you have a better example of how to generate these files and how to compile them?
Last updated: 2024-12-03
Post by helcioburd on How long can a WSTRING be in CodeSys V3?
CODESYS Forge
talk
(Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02
Post by r0udy on Adress problem
CODESYS Forge
talk
(Post)
Hi, I 've just started a new project. Translating SoMachine (SCHNEIDER) to CODESYS 3.5.18//DEMO (EATON XC303) I succeed (I think so) to copy FB, STRUCT,... and I also integrated old library. When I build F11, I have a first problem : - Adress out of rang - Overlay It's strange, usually %ML100 > %MB800 Here ONLINE: %ML100 > %MB100 !! I don't understand why ? And idea ? Thanks
Last updated: 2025-08-06
Post by masmith1553 on SDO generation
CODESYS Forge
talk
(Post)
If you add any device to the CANOpen Manager it will send messages to verify the device is on the network. Do you have the Enable expert settings check box checked in the General tab? have you added any SDOs in the SDOs tab? I avoid using the CANOpen Manager and just use the CAN_Tx and CAN_Rx blocks from the library.
Last updated: 2024-01-25
Post by florian on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Codesys has a motion libraries (SoftMotion), but you need to buy a licence keys for them to work. the most basic one is SoftMotionLight. you just have to select your drive in the device view and add a SoftMotionLight CiA402 axis. then the library is added to your project. You can use the SML_* motion FBs and configure the axis now.
Last updated: 2024-03-22
Post by gatto on variables between two applications
CODESYS Forge
talk
(Post)
Hello, I'm experimenting with two applications. I was able to start stop applications with the CmpApp library. Currently in my test the variables declared in the first application are not visible and writable in the second. I ask if there is the possibility of having variables that are visible both in the first application and in the second.
Last updated: 2024-06-22
Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon
CODESYS Forge
talk
(Post)
I got this code working again. 3S/CoDeSys, your level of obfuscation and lack of documentation turns a simple task into a monumental complex challenge. The issue was that at some point the IecVarAccessLibrary changed and no longer allowed using IBaseTreeNode to retrieve a child or the number of children. The attached code has been updated to use IIecVarAccess6.VarAccBrowseGetChildByIndex instead. The code was also cleaned up but is still a work in progress. The current example only works one layer deep. This means native data types, arrays, and single-layer structures are supported. However, structure arrays and nested structures are not yet supported.
Last updated: 2025-08-25
Post by dekelec on Codesys 2.3 & Peak PCAN
CODESYS Forge
talk
(Post)
IF you have an USB interface type in "Peak_USB" for CAN card driver (Name of CAN card driver). No need to add libraries for communication via CoDeSys Gateway. For other card types contact PEAK support and they will help you. Regards,
Last updated: 2024-07-08
Post by pietrobalint on Persistent variables are not read after initialization
CODESYS Forge
talk
(Post)
Hi, I have Raspberry Pi 5 and I would like to use persistence manager too. But Codesys support said that Application Composer not compatibile with my runtime. Could you recommend a solution?
Last updated: 2024-09-01
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
BTW - I had a chat with a Beckhoff support engineer. He explained that if you use sync0 and sync1, two frames per cycle are expected.
Last updated: 2024-09-19
Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Do someone have any information on this topic ? We tried several different CM4 boards without success, and we cannot install the licenses we bought anymore... Isn't CodeSys supposed to support CM4 Raspberry pi ?
Last updated: 2024-10-15
Post by jonasz on TargetVisu not accepting touch inputs
CODESYS Forge
talk
(Post)
So, in my case, the solution is to uncheck the option to support client animation and overlay native elements. Visualisation Manager -> Settings -> General Settings
Last updated: 2025-08-19
Post by hclai on Table Content with Multilanguage
CODESYS Forge
talk
(Post)
I have an data structure which intend to list in a table and let user to add the content to the table. How can we able to support for displaying different language in the content of the table? which is dynamic to the user input.
Last updated: 2024-01-10
Post by anttimurtsi on Html5 controls error
CODESYS Forge
talk
(Post)
Im trying to create new HTML5 controls to my project but every control that i create gives a error "It is only usable with active overlay support and within visualisation on webvisu" ive looked to fix this problem but havent found anything that wouldve solved it.
Last updated: 2024-01-29
Post by jdjennings1962 on Is there any support for I2C on Raspberry Pi?
CODESYS Forge
talk
(Post)
Here are the links to the specific hardware we are trying to use: https://learn.adafruit.com/adafruit-dc-and-stepper-motor-hat-for-raspberry-pi/powering-motors https://www.sparkfun.com/products/16476
Last updated: 2024-02-29
Post by macros8 on Viewing PDF in WebBrowser Visual Element
CODESYS Forge
talk
(Post)
No, you canΒ΄t. I have only tried different browsers on my PC and then on my HMI device. Unfortunately the deviceΒ΄s browsers did not support pdf file as I needed so I had to switch to *.txt.
Last updated: 2024-03-01
Post by tvm on Timer On Vijeo
CODESYS Forge
talk
(Post)
Vijeo doesn't support TIME variables, so the easiest thing to do is convert to a STRING in your program, and use that variable. You could use TimeAsString:= TIME_TO_STRING(TimeVar) to get a string that looks like this: T#5h10m45s200ms
Last updated: 2024-05-07
Post by s1mon on Two OneWireMaster on one Raspberry PI 5
CODESYS Forge
talk
(Post)
yes sure. Thx for your support! This is the Codesys project stripped down only to my EtherCat and OneWire Configuration. The Project now contains only one OneWire Master on GPIO4.
Last updated: 2025-10-20
Post by unusual-data on C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
you can try to disable "Visualization Manager - Settings - Support client animations and overlay of native elements " selection" It worked for me, thank you.
Last updated: 2025-12-18
Post by struccc on Wish: CODESYSControl.cfg - again
CODESYS Forge
talk
(Post)
Before creating this topic, I was browsing the search results for CodesysControl.cfg - many results, and I remember very well, it's a problematic issue for a long time. To summarize: there were many requests for documentation on this file - the most comprehensive reply is: https://forge.codesys.com/forge/talk/Runtime/thread/ebbf851a3d/#eb85 Hi, not really, this is covered by the manual which you get if you use a runtime toolkit which is not free of charge. Maybe we need to extract the config file part from that documentation if that is possible. BR Edwin I am not sure how much is this relevant, since we buy SL License directly from CODESYS... I think it is a reasonable demand, to get documentation on the configuration entries affecting the documented behaviour of the runtime system and it's components The actual reason I bring up this issue again can be read here: https://forge.codesys.com/forge/talk/Runtime/thread/febad3cc40/#0e12 but mostly my frustration about noticing some new, unknown and undocumented entries in my configuration file. Again. And this happens a lot recently. Just some examples: Changes with SysFile - and mandatory use of IEC path Introduction of Mandatory user management File transfer service now disabled by default SysProcess - allowed commands The above mentioned CmpApp parameters... And finally (Regaridng windows install): With the newer versions, the installation directory (together with the configuration file) tends to hide itself to some super silly location under the roaming profile data of local system account. I am not sure if this change was documented somewhere, but was a very unpleasant one. Someone could please explain the reason and the concept of the introduction of this release specific directories (I am sure, there is a good reason) - how to use them properly? - How to re-introduce user configuration (to preserve configuration data between versions)? - How to do version - to version migrations properly? - How to keep old version of runtime available and ready to start with it's original configuration and application? - ... Therefore, the lack a regularly updated description of CodesysControl .cfg , including all the configuration entries, together with their default values for different runtime versions is really a big deficiency.* This should be done for all components storing or just seeking data from this file... (Maybe there is such thing but I failed to find???) It is regularly causing trouble when introducing a new version (together with the long awaited bug fixes and enhancements), what has changed it's default behaviour for security or other practical reasons. I agree this is very important, and it is logical to change the default options: But it must be documented historically, and make it easily available, so we can prepare better for the upgrade of the runtime. Forge talk is a great source, but not very practical for this kind of documentation purposes... Thanks in advance for CODESYS staff πππ (Ps.: It would look rather silly, if some members of the user community prepares this documentation on a Forge Wiki page... Or??? Should we?)
Last updated: 2024-11-21
Post by trusty-squire on How to revert to previous version library
CODESYS Forge
talk
(Post)
Hi, I'm experiencing a bug with the latest version of SoftMotion CNC library (4.17), where the 3DPath object in Visu is missing all the important properties. I've verified that a previous app I was working on with library version 4.16 did not have this issue and the issue is duplicated in that project when I update it to 4.17. I've already submitted a bug report, but for the time being I need to revert the project I'm currently working on back a revision. I've tried right clicking on the library but the option to select the version is greyed out. Can anyone help me?
Last updated: 2024-09-05
Post by caliberbishop on Having trouble using the Web Client SL library
CODESYS Forge
talk
(Post)
Hello, I'm trying to use the Web Client SL library, I installed it in the IDE (did not purchase a license yet, as this is still a proof of concept so demo mode is good enough) and added it to the library manager. However, when trying to define a FB of the type WebClient I get a "Identifier 'WebClient' not defined" error message, setting the type to Web_Client_SL.WebClient did not work as well. Opening the example project the FBs defined there give the same error message. From the problem in the example project I deduce this is not a syntax problem, so maybe a license problem, but there should be a working demo mode, so what am I missing? IDE v 3.5.21.30 Library v 1.12.0.0 Thanks
Last updated: 2025-10-04
Post by forest on SM Drive license error
CODESYS Forge
talk
(Post)
Hi, when it comes about license, I used INVTmatic Studio, which uses Codesys, for programming INVT plc. I bought Codesys Modbus license, it was not expensive, and then realised that INVT didn't have License Manager option (greyed out in program) which is needed for using of Codesys License. I contacted support from INVT, but developers told me that option is still not available. So depending on environment for programming Codesys, you can or not use Modbus license. Good thing about this version of Modbus TCP it works both direction. I could send commands and receive feedbacks from drive. But communication stops after 30 mins. So I used simple version of ethernet modbus which is somewhere in INVT or Condesys library (I can check tomorrow) which works only one way. I could send cmd to drive, and control it, but didn't have any feedback, like some readings back in PLC. which is bad, but at least I could start it and it didn't fail after 30 mins.
Last updated: 2024-01-10
Post by alimans on OPC-UA Server, Symbol Set: Raise an error: Object reference not set to an instance of an object.
CODESYS Forge
talk
(Post)
Hi everyone, I just created a very simple library without any code and, added it to my very simple project. after adding this library, I get an error when I try to open "Symbol Set" in "OPC UA Server" in "Communication Manager". Here is the code of my POU in the library: FUNCTION_BLOCK POU VAR eCommand : (CMD_NONE:=0, CMD_RESET:=-1) INT := CMD_NONE; END_VAR Attached is the error that I get. I also noticed that by removing the enumeration variable above (eCommand), I can open the "Symbol Set" again. Anybody has any idea why this error is raised and how could I use enumeration variables without error in "OPC UA Symbol Set"?
Last updated: 2024-08-08
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.