Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
If support for a containerized CODESYS runtime with a license isn't feasible, then I've considered an alternative approach: I've purchased and activated a "CODESYS Control Basic S" license on my Windows notebook, where I already have the Codemeter Control Center installed. Upon activation, I can see the CODESYS license as active on my notebook. Subsequently, I followed the instructions provided in this link (https://faq.codesys.com/display/CDSFAQ/How+to%3A+Setup+a+Wibu+Network+Server+Access+for+Licenses) to configure the Wibu runtime in the CODESYS container to access my external license server hosted on my notebook by editing the CODESYSControl_User.cfg file accordingly. However, it's worth noting that I'm still receiving a response from the Licensing Manager indicating that the runtime is persistently searching for a dongle instead of recognizing the soft container. So how can I get my runtime licensed now? Any ideas?
Last updated: 2024-03-20

Post by tecnocons on Trouble Writing Files to External Paths in CODESYS CODESYS Forge talk (Post)
Hello everyone, I'm encountering an issue in CODESYS regarding writing files to external paths. Despite correctly configuring the placeholder in the CODESYSControl_User.cfg file to allow access to an external folder, CODESYS doesn't seem to write any files, and no errors are reported. The issue on the older versions was absent with no placeholders. I've checked the operating system permissions, and they seem to be in order, but the issue remains. Has anyone faced a similar situation or has any suggestions on how I might resolve this problem? Any help would be greatly appreciated. Thank you in advance for your support. I'm using raspberry PI as a logger. RPI3 Buster Codesys 32bit SL V4.11 Codesys Win64 3.5.20 [SysFile] PlaceholderFilePath.1=/home/pi/scan, $SCAN$
Last updated: 2024-04-09

Post by bschraud on UnerwĂĽnschte Username- und Passwortabfrage im Browserfenster CODESYS Forge talk (Post)
Hallo, die Option CallVisuServicesDirectly=1 verändert das Verhalten leider nicht. In Codesys gibt es noch in den Einstellungen der Webvisu den Eintrag unter Login-Visualisierung. Das Löschen dieses Eintrages ergibt aber auch keine Änderung. Evtl. wird bei der neuen Codesys Version für die Webvisu eine https Verbindung vorausgesetzt. Zu dem Thema bin ich im Thread https://forge.codesys.com/forge/talk/Visualization/thread/5767230df2/ auf die Beschreibung im Installationsverzeichnis unter file:///C:/Program%20Files/CODESYS%203.5.20.0/GatewayPLC/Documentation/WebServerSSL_de.pdf gestoßen. Allerdings gibt es dort Diskrepanzen zwischen der Verzeichnisstruktur auf meinem Gerät und in der Beschreibung. Also werde ich in dieser Richtung weiterforschen. Vielleicht hat noch jemand einen Tip, wie die Webvisu schnell auf https umgestellt werden kann. Vielen Dank!
Last updated: 2024-04-10

Post by dkugler on build (F11) / generate code using a python script file CODESYS Forge talk (Post)
thank you very much! I found the generate_code methode, but struggled with the primary and active_application. With this expample I will be able to play around. If the code generation takes a minute or more I often switch to other programs and don't notify the process is finished. So now I'll get an alert and will switch back immediately. My next little project will be, to beep different if there are errors and a seperate script to do the download incl. the user management data base without stopping at the dialogs asking for onlinechange/complete download and overwriting an existing database and as goody, play a beep/sound again.
Last updated: 2024-04-11

Post by stewnguth on New License not working. CODESYS Forge talk (Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23

Post by spice on WebVisu Recipe Save/Load CODESYS Forge talk (Post)
I'm currently reworking the controls on a cnc press brake and wanted to load various recipes as programs to run. I'm using a 2d array of REALs to store the X and Y coordinates as well as some other program parameters in a recipe. I'd like to store all of the recipes on a computer used as the HMI that way the text files can be edited and uploaded offline. I'm using Automation Directs P2CDS-622 Can this be done through webvisu? If not would a license for Codesys HMI SL on the computer allow me to accomplish this? I've attached the Project File Thanks, Spice
Last updated: 2024-05-31

Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3) CODESYS Forge talk (Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10

Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device CODESYS Forge talk (Post)
Hello, CODESYS Control is running on my RevPi, and my system communicates over a CANbus with a master using the ConnectCan module (Slave - CANopen Device). The communication works perfectly fine so far. However, as soon as I call a Python script with "SysProcessExecuteCommand2" that creates a CSV file and executes without errors, the master does not adopt any changes to the Transmission Process Data Objects (TPDOs). I don't quite understand what one has to do with the other, and perhaps someone can help me with this. Here is my script call: SysProcess.SysProcessExecuteCommand2(pszCommand:='python /home/pi/test.py', pszStdOut:=sCMDOutput, udiStdOutLen:= SIZEOF(sCMDOutput), pResult := ADR(eResult)); Thank you in advance! Best regards, Stefan
Last updated: 2024-06-20

Post by wchin on Passing EtheNetIP adapter device into a Function Block to access it's IO CODESYS Forge talk (Post)
We are creating helper function blocks for our VFD(EtherNetIP). How should I set it up so that I can pass the device into and out of the Function Block so that ideally I can access the IO of the device by devicename.channelname. So something like for example we have a VFD with a start bit that is in the ControlWord channel and a SetVelocity that is a channel. And we want to create a Function Block called StartVFD. So I declare something like: FUNCTION_BLOCK StartVFD VAR_IN_OUT device: ioDrvEthernetIP.RemoteAdapter; END_VAR VAR_INPUT velocity : REAL; So in the code it would look something like device.SetVelocity := velocity; device.ControlWord.6 := True; We have a pretty basic eds file for our VFD and can update it if necessary. Thanks in advance.
Last updated: 2025-10-28

Post by wchin on Passing EtheNetIP adapter device into a Function Block to access it's IO CODESYS Forge talk (Post)
We are creating helper function blocks for our VFD(EtherNetIP). How should I set it up so that I can pass the device into and out of the Function Block so that ideally I can access the IO of the device by devicename.channelname. So something like for example we have a VFD with a start bit that is in the ControlWord channel and a SetVelocity that is a channel. And we want to create a Function Block called StartVFD. So I declare something like: FUNCTION_BLOCK StartVFD VAR_IN_OUT device: ioDrvEthernetIP.RemoteAdapter; END_VAR VAR_INPUT velocity : REAL; So in the code it would look something like device.SetVelocity := velocity; device.ControlWord.6 := True; We have a pretty basic eds file for our VFD and can update it if necessary. Thanks in advance.
Last updated: 2025-10-28

Post by wchin on Passing EtheNetIP adapter device into a Function Block to access it's IO CODESYS Forge talk (Post)
We are creating helper function blocks for our VFD(EtherNetIP). How should I set it up so that I can pass the device into and out of the Function Block so that ideally I can access the IO of the device by devicename.channelname. So something like for example we have a VFD with a start bit that is in the ControlWord channel and a SetVelocity that is a channel. And we want to create a Function Block called StartVFD. So I declare something like: FUNCTION_BLOCK StartVFD VAR_IN_OUT device: ioDrvEthernetIP.RemoteAdapter; END_VAR VAR_INPUT velocity : REAL; So in the code it would look something like device.SetVelocity := velocity; device.ControlWord.6 := True; We have a pretty basic eds file for our VFD and can update it if necessary. Thanks in advance.
Last updated: 2025-10-28

Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16

Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40 CODESYS Forge talk (Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16

Post by jp0951269346 on How to reset forgotten User Management / Administrator password on CODESYS Control Win V3 (V3.5 SP22 Patch 2)? CODESYS Forge talk (Post)
Hi everyone, I forgot the Administrator credentials for my local Soft PLC (CODESYS Control Win V3x64) running on CODESYS V3.5 SP22 Patch 2 (Windows 11). When I try to login/connect to the device, it asks for the Device User Management username and password. I checked the CODESYSControl.cfg file, which points the working directory to: Windows.WorkingDirectory=%APPDATA%\CODESYS\CODESYSControlWinV3x64\905D4E32 However, I cannot locate the actual database/credentials files in AppData or ProgramData to clear them, and resetting the runtime directory doesn't seem to clear the authentication prompt. Could anyone please advise the correct steps to completely reset or wipe the User Management credentials for the Control Win V3.5 SP22 runtime? Thank you in advance!
Last updated: 2026-08-25

Post by swol on HTML 5 - Controls -> Change Content-Security-Policy settings CODESYS Forge talk (Post)
Sorry for being late to the party... so it is not possible to use the webbrowser tool to display external websites in a visu anymore? As it is not possible to simply "adjust the ContentSecurityPolicyIncludeTrustedOrigins setting in the automatically generated webvisu.cfg.json file" as stated in the docs? We need to display data read from a Raspberry Pi (part of our computer network) in our webvisu. We used to do it by entering the Pi's IP address as the URL variable in the webbrowser element but now (I don't know since when, I'm new on the job) "The page’s settings blocked the loading of a resource (frame-src) at 'IP address' because it violates the following directive: “default-src 'self' 'unsafe-inline'”. What are the options for displaying the data?
Last updated: 2025-11-11

Post by ranadheer on Assistance for MQTT configure with external broker (Mosquitto) CODESYS Forge talk (Post)
Hi everyone Am trying to make establish MQTT connection , where am using IIOT example for this as a demo mode. where i had given IP-address of of local Linux application as a 172.31.239.67 and port number as 1883 in the PLC_PRG itself, and preparing the publish message by manually as " this is from published message", and this should receive at the subscriber side. Aim: To make communicate external publisher to the CODESYS by using MQTT protocol. By any chance having reference documents about this implementation please share here. and suggest the process to make it possible. I had uploaded reference project file after updating address in th PLG_PRG, kindly assist to configure with the broker
Last updated: 2025-12-03

Post by arwie on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
An other approach is to split the application into a hard real-time part running in CODESYS and the business logic running in Python asyncio. The business logic part is usually bigger and changes more often. As Python code is pure text, vscode and git are your friends. A performance example on YouTube (CODESYS SoftMotion + Python): https://www.youtube.com/watch?v=BT-L0H_4Aic Docs and code on GitHub: https://github.com/arwie/controlOS_demo/blob/main/docs/codesys_python_link.md Real-time variable exchange between a CODESYS application and a Python application running in parallel, using POSIX shared memory.
Last updated: 2026-06-21

Post by afrazeh2026 on Curtis 1226BL Drive CODESYS Forge talk (Post)
Subject: Curtis 1229-4105 CANopen (CiA 301 / CiA 402) Hello everyone, I am developing a battery-powered industry vehicle using a Curtis 1229-4105 motor controller together with a Siemens S7-1200 PLC and an HMS (Ixxat) CANopen Master. I am looking for someone who has practical experience with the Curtis 1229-4105 CANopen implementation. I would appreciate your help with the following questions: Does the Curtis 1229-4105 support only CANopen CiA 301, or does it also support CiA 402? Is an EDS file available for this controller? Is the CANopen Object Dictionary available? Has anyone successfully communicated with the Curtis 1229-4105 from a Siemens S7 PLC or another CANopen master? Are the CANopen PDOs and Object Dictionary based on the standard CiA profile, or are they Curtis-specific? Any documentation, examples, or practical experience would be greatly appreciated. Thank you very much.
Last updated: 2026-07-15

Post by brouwyka on JSON Utilities - JSON file written with invalid structure CODESYS Forge talk (Post)
Hey there! I am currently running into the exact same issue (and have also posted to a similar post here: https://forge.codesys.com/forge/talk/Engineering/thread/c45929e2f1/#e27f). The JsonData object has all inexes & parent indexes in the way I expect, everything is correctly "linked". It purely seems that the writer is incorrectly parsing said JsonData, not based on parent & child index, but on something else that breaks it and puts things at the root, instead of the specified parent index. Did you ever manage to find a solution, or another way of achieving your JSON composing? I'm currently working on Codesys V3.5 SP19 Patch 7 with IIOT Libraries SL 1.13.0.0, specifically JSON Utilities SL 1.13.0.0 (to send requests to APIs with JSON bodies using Web Client SL 1.13.0.0).
Last updated: 2026-06-08

Post by trusty-squire on SysProcessCreate2 on Linux runtime CODESYS Forge talk (Post)
Hi, I'm trying to launch a continuously running python script from Codesys and monitor the script status inside the Codesys runtime (running on a Linux enviroment). For now I'm testing with the below to emulate a continuously running Python script: #test.py i = 0 while True: i += 1 I'm able to successfully run the script using SysProcessExecuteCommand2 (I can see the Python process running in the task manager). However, this "freezes" the Codesys execution of the task - it sits on that command and will not continue until the Python script ends. I've proven this works by using the task monitor to kill the process, then Codesys continues on happily through the task. What I want to do is use SysProcessCreate2 to set up the Python script as a background task and monitor the process using SysProcessGetState. This always results in the error "ERR_OPERATION_DENIED". I know that I'm able to execute commands (as above), so my config should be correct. Is SysProcessCreate2 functional on a Linux environment? Is there something in the config file I'm missing? Here's my "working" code that uses SysProcessExecuteCommand2: VAR bTest : BOOL; sCommand : STRING := '/usr/bin/python3 /var/opt/codesys/PlcLogic/Application/test.py'; refCommand : REFERENCE TO STRING REF= sCommand; sOutput : STRING; refOutput : REFERENCE TO STRING REF= sOutput; result : RTS_IEC_RESULT; END_VAR IF bTest THEN SysProcessExecuteCommand2( pszCommand:= refCommand, pszStdOut:= refOutput, udiStdOutLen:= SIZEOF(sOutput), pResult:= ADR(result) ); bTest:= FALSE; END_IF And here's the code that always results in the ERR_OPERATION_DENIED error: VAR bTest : BOOL; sApp : STRING := '/usr/bin/python3'; sCommand : STRING := '/var/opt/codesys/PlcLogic/Application/test.py'; refApp : REFERENCE TO STRING REF= sApp; refCommand : REFERENCE TO STRING REF= sCommand; hResult : SysProcess.RTS_IEC_RESULT; hHandle : SysProcess.RTS_IEC_HANDLE; END_VAR IF bTest THEN hHandle := SysProcessCreate2( pszApplication:= refApp, pszCommandLine:= refCommand, ulFlags:=SYSPROCESS_CREATEFLAG_HIDDEN, pResult:= ADR(hResult) ); bTest:= FALSE; END_IF Here's the relevant section from the config file at /etc/codesyscontrol/CODESYSControl.cfg: [SysProcess] Command=AllowAll Appreciate any support or ideas. Thanks!
Last updated: 2025-03-16

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' °C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' °C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by t-probst on Strong Private Key Protection for Encryption Certificates CODESYS Forge talk (Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22

Post by bbm1995 on Camera RTSP Feed CODESYS Forge talk (Post)
Hi dgrard, I had the same issue for a long time, but on a WAGO webvisu. Now I'm glad that I can share my solution. I don't know if you are trying to use the webvisu or the target visu, but this works on webvisu: Get "go2rtc" and set it up according to the documentation. I'm running the Windows binary. Here's my example of the go2rtc.yaml config file (contains working example streams): api: listen: ":1984" # default ":1984", HTTP API port ("" - disabled) origin: "*" # default "", allow CORS requests (only * supported) static_dir: "www" # default "", folder for static files (custom web interface) tls_listen: ":443" # default "", enable HTTPS server tls_cert: "./SSL/fullchain.pem" tls_key: "./SSL/privatekey.pem" streams: # Streams with multiple links will fall back on the next link. ABUS TVIP48511: - rtsp://<username>:<password>@<hostname>:<port>/ch1/main - rtsp://<username>:<password>@<hostname>:<port>/ch1/sub # Diagnostic connections Kirchhoff Institute for Physics - Germany: http://pendelcam.kip.uni-heidelberg.de/mjpg/video.mjpg Blanton Bottling, Kentucky - USA: http://camera.buffalotrace.com/mjpg/video.mjpg Tokyo - Japan: http://61.211.241.239/nphMotionJpeg?Resolution=320x240&Quality=Standard Tampere Hacklab - Finland: http://tamperehacklab.tunk.org:38001/nphMotionJpeg?Resolution=640x480&Quality=Clarity Soltorget Pajala - Sweden: http://195.196.36.242/mjpg/video.mjpg Kaiskuru Skistadion - Norway: http://77.222.181.11:8080/mjpg/video.mjpg webrtc: listen: ":8555" #ice_servers: # - urls: [ "stun:localhost:3478" ] # username: "" # credential: "" Access the webinterface of go2rtc and get the link of your stream. Use the link as for your browser frame in the visualization. Depending on your device, you need to be able to access the file /etc/lighttpd/lighttpd.conf or /etc/lighttpd/webvisu.conf and change the contents similar to this one, otherwise you'll get CORS and CSP errors in the browser and you won't be able to view the stream on the webvisu: # Webvisu specific settings $SERVER["socket"] =~ port_webvisu_used_any { url.redirect += ( "^/webvisu/?$" => "/webvisu/webvisu.htm" ) $HTTP["url"] =~ "^/webvisu/?" { var.response_header_policy_webvisu = ( # CSP for WebVisu, allowing inline sources. "Content-Security-Policy" => "default-src 'self' 'unsafe-inline'; media-src *; frame-src *", # CORS for WebVisu, allowing any origin to access. "Access-Control-Allow-Origin" => "*", # Tell older browsers that this page can only be displayed if all ancestor # frames are same origin to the page itself. "X-Frame-Options" => "SAMEORIGIN" ) # Response header policy for WebVisu setenv.set-response-header = var.response_header_policy_webvisu setenv.set-response-header += var.response_header_policy_common }
Last updated: 2023-11-14

Post by struccc on Application failing to boot after system reboot CODESYS Forge talk (Post)
I started to experience the same issue, after upgrading to 3.5.19 , and still persists with 3.5.20.3 , using CodesysControlWinV3 x64 on Windows. Unfortunately, this is a live application, normally it is running for months without interruption - so it was a surprise at the last cold start... It was not possible to go online with the original version, so I couldn't see the application, or system status, just the log message. First time I manually clean the Application from the PlcLogic directory (there was no coredump file in there), then I could start the runtime service, and do a fresh download, and set the bootproject. I could not try a cold system reboot - it's in a 24/7 production environment, and I was under heavy pressure to start... What I did, I have created a backup from the * complete * runtime directory, from the failed, and fixed version - before and after download. This directory in my case C:\ProgramData\CODESYS\CODESYSControlWinV3x64\55096128 - At the next shutdown, it was sufficient to copy back this backup completely, and could start the runtime service afterwards. Ugly, but local staff with some skills can do it without programming tool... I don't store any live data, configuration, log files, persistent data in this directory - the only reason I need this is to edit the CodesysControl... .cfg file.... And to see the logfiles in emergencies like this. The application concerned doesn't use any retain area. - exactly for these reasons - Maybe that is causing the problem with the newer runtime versions As far as I see, this problem occurs only if the power of the Windows PLC is interrupted without a proper shutdown. Unfortunately, this can happen sometimes. The newer versions, seems tp modify CodesysControl.cfg on the fly, and register the applications, and bootproject information after download. (I don't really see CodesysControl.cfg a proper location for this... but that's just my feeling) So now I had a look at CodesysCotrol.cfg on my laptop and I found: [CmpRetain] ;Retain.SRAM.Size=0x200200 ;Retain.SRAM.Address=0xFA3C5776 ;SimulateSRAM=1 [CmpApp] ;Bootproject.CreateOnDownload=0 ;Bootproject.StoreOnlyOnDownload=0 ;Bootproject.InvalidateByRename=1 ;Bootproject.InvalidateBySetting=1 ;Bootproject.InvalidateNever=0 ;PersistentForce=0 ;RetainType.Applications=InSRAM ;RetainType.Applications=OnPowerfail ;RetainType.Applications=None ;Exception.Hardware.GlobalStop=1 Application.1=MyTestAppNoRetain The last line appeared after download and boot project creation. Maybe... Should set RetainType.Applications=None? I wonder about all these settings, but... Will write separately about it. I hope this helps a little...
Last updated: 2024-11-21