Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02

Post by hanoues on setting date and time on CPX-E CODESYS Forge talk (Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21

Post by tortilla on J1939 connection between two devices CODESYS Forge talk (Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23

Post by william-blandon on RecipeManCommands.ReloadRecipes CODESYS Forge talk (Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23

Post by bmatlove on Re-create CoE online window in Visu CODESYS Forge talk (Post)
Hello, I am trying to re-create the CoE online window within a Visu for purposes of checking and interacting with device parameters occasionally for maintenance purposes. To minimize reliance on using the IDE for misc interactions. Ideally, I would like to exactly mimic the CoE online window within the IDE. I assume that it uses a few tricks to minimize overhead, such as only polling registers which are within the visual scope, for example. I'm afraid it might be too much to ask for a pre-built drop-in Visu module to exist for this task. Do I have any options aside from manually re-creating all the logic to do this, relying heavily on SdoInfo function blocks? Is there a way for me to reference the device ESI file to shortcut the process of determining how many registers there are and getting the address for each?
Last updated: 2025-12-27

Post by nickpoon on SysProcessCreate stopped working after SP21? CODESYS Forge talk (Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02

Post by konstantin on CAM Motion Recover after STO CODESYS Forge talk (Post)
Hello Mr. Seidel, both the master and the slave axis are modulo. Basically the situation is as follows: One master cycle is 100 units. Slave's modulo length is 2000 units. In the CAM table I defined 10 master cycles on X axis - 1000 units and on the Y axis is the slave - 2000 units. Then depending on the master position 0 to 1000 units the slave's position is plotted on the Y axis - 0 to 2000 units. For example, while the master is executing the 3rd cycle i.e. above 200 units, I trigger the STO function of the slave and it stops. The master executed his cycle but the slave was stopped during the execution. How can I set the slave to continue the CAM sequence from the point where it stopped i.e. third cycle of the master? When I reset the slave error and sync again, everyrhing starts from master's 0 position. Best Regards Konstantin Kolev
Last updated: 2026-02-13

Post by charleskirkland on Connect to Azure IoT Hub CODESYS Forge talk (Post)
It sounds like your TLS setup is basically correct, since the handshake works via OpenSSL, so the issue is likely on the CODESYS side rather than the certificates themselves. From what I’ve seen with the Azure IoT Hub Client SL library, you should double-check that the SAS token is actually being generated and passed correctly to the function blocks (especially wsDeviceSaS) and that the MQTT/HTTPS FB is really triggered cyclically-otherwise the controller won’t initiate the connection at all. Also, make sure DNS, time (NTP), and full certificate chain trust are properly configured on the controller, since IoT Hub authentication depends on them even when using SAS tokens. Another thing worth checking is the library/runtime version-there are reports that certain versions changed behavior and caused connection issues. I’d recommend starting with the official demo project (AzureMQTTDemo) and comparing it step by step with your setup to see what’s missing or not triggered. Speed Stars
Last updated: 2026-04-27

Post by timvh on USB Game Controller with Raspberry Pi CODESYS Forge talk (Post)
I'm not sure it will work, but you could try it with the CmpCharDevice library. You could create a function block that looks something like this: As input for the filename, you have to use your Linux device, e.g.: '/dev/input/event0' '/dev/input/by-path/platform-button@23-event' Off course you must also pass the pointer to the memory where the data can be written to and the size (count in number of bytes) of the buffer. FUNCTION_BLOCK FB_CharDevice VAR_INPUT szFilename: STRING; pbyBuffer : POINTER TO BYTE; udCount : UDINT; END_VAR VAR_OUTPUT iState : INT := 0; nrBytesRead : DINT; END_VAR VAR xInit : BOOL := TRUE; dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice: CmpCharDevice.CmpCharDevice_Implementation.RTS_IEC_HANDLE := -1; Result : CmpCharDevice.CmpCharDevice_Implementation.RTS_IEC_RESULT; END_VAR IF xInit THEN hDevice := CmpCharDevice.CDOpen(szFilename, dFlags ,Result); // if it would not succeed, the result is -1 (Invalid handle) IF hDevice <> 16#FFFFFFFF AND Result = 0 THEN iState := 5; END_IF xInit := FALSE; END_IF IF iState = 5 THEN nrBytesRead := CmpCharDevice.CDRead(hDevice, pbyBuffer, udCount, Result); ELSE nrBytesRead := 0; END_IF Make sure you close the connection properly, maybe by overwriting the default FB_Exit method of the FB: // Clean up device IF hDevice <> 16#FFFFFFFF THEN __TRY CmpCharDevice.CDClose(hDevice,Result); __CATCH ; __ENDTRY iState := 0; END_IF
Last updated: 2026-05-01

Post by shamcke on Array with generic constant as persistent variable CODESYS Forge talk (Post)
Hello, I have written a function block that uses a generic constant for the upper bound of an array. I wanted to have this array in the persistent memory area, thus I constructed my FB as follows: FUNCTION_BLOCK FbWithGenericArrayLength VAR_GENERIC CONSTANT uiArrayLength : UINT := 10; END_VAR VAR PERSISTENT arr : ARRAY[1..uiArrayLength] OF INT; END_VAR In my PLC_PRG I declare an instance of said FB PROGRAM PLC_PRG VAR myFb : FbWithGenericArrayLength<10>; END_VAR This compiles just fine. When I let CODESYS fill my persistent list, it adds duplicate entries {attribute 'qualified_only'} VAR_GLOBAL PERSISTENT RETAIN // Generated instance path of persistent variable PLC_PRG.myFb.arr: ARRAY [1..uiArrayLength] OF INT; // Generated instance path of persistent variable PLC_PRG.myFb.arr: ARRAY [1..uiArrayLength] OF INT; END_VAR so I manually delete the duplicate. When i now compile, I get errors ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... [ERROR] Sandbox_FW31: PersistentVars [Device: PLC Logic: Application](Line 4): C0161: Border 'uiArrayLength' of array is no constant value [ERROR] Sandbox_FW31: PersistentVars [Device: PLC Logic: Application](Line 4): Type of mapped variable is not equal to original type Compile complete -- 2 errors, 0 warnings Build complete -- 2 errors, 0 warnings : No download possible Is is simply not possible to use a generic constant for the persistent array? Thanks in advance. Edit: It seems I can manually replace the uiArrayLength in the persisten list by the value 10 I used as the generic constant for this particular instance.
Last updated: 2026-05-29

Post by struccc on Wish: CODESYSControl.cfg - again CODESYS Forge talk (Post)
Before creating this topic, I was browsing the search results for CodesysControl.cfg - many results, and I remember very well, it's a problematic issue for a long time. To summarize: there were many requests for documentation on this file - the most comprehensive reply is: https://forge.codesys.com/forge/talk/Runtime/thread/ebbf851a3d/#eb85 Hi, not really, this is covered by the manual which you get if you use a runtime toolkit which is not free of charge. Maybe we need to extract the config file part from that documentation if that is possible. BR Edwin I am not sure how much is this relevant, since we buy SL License directly from CODESYS... I think it is a reasonable demand, to get documentation on the configuration entries affecting the documented behaviour of the runtime system and it's components The actual reason I bring up this issue again can be read here: https://forge.codesys.com/forge/talk/Runtime/thread/febad3cc40/#0e12 but mostly my frustration about noticing some new, unknown and undocumented entries in my configuration file. Again. And this happens a lot recently. Just some examples: Changes with SysFile - and mandatory use of IEC path Introduction of Mandatory user management File transfer service now disabled by default SysProcess - allowed commands The above mentioned CmpApp parameters... And finally (Regaridng windows install): With the newer versions, the installation directory (together with the configuration file) tends to hide itself to some super silly location under the roaming profile data of local system account. I am not sure if this change was documented somewhere, but was a very unpleasant one. Someone could please explain the reason and the concept of the introduction of this release specific directories (I am sure, there is a good reason) - how to use them properly? - How to re-introduce user configuration (to preserve configuration data between versions)? - How to do version - to version migrations properly? - How to keep old version of runtime available and ready to start with it's original configuration and application? - ... Therefore, the lack a regularly updated description of CodesysControl .cfg , including all the configuration entries, together with their default values for different runtime versions is really a big deficiency.* This should be done for all components storing or just seeking data from this file... (Maybe there is such thing but I failed to find???) It is regularly causing trouble when introducing a new version (together with the long awaited bug fixes and enhancements), what has changed it's default behaviour for security or other practical reasons. I agree this is very important, and it is logical to change the default options: But it must be documented historically, and make it easily available, so we can prepare better for the upgrade of the runtime. Forge talk is a great source, but not very practical for this kind of documentation purposes... Thanks in advance for CODESYS staff 🙏🙏🙏 (Ps.: It would look rather silly, if some members of the user community prepares this documentation on a Forge Wiki page... Or??? Should we?)
Last updated: 2024-11-21

Post by jeffg on ERROR: GetNetLinkSockAndInfoByMac(): could not open netlink socket: Too many open files CODESYS Forge talk (Post)
I just installed codesys runtime on a raspberry pi Cortex-A72 (ARM v8) 64-bit SoC @ 1.5GHz (Compute Module 4) I am running on Codesys control for raspberry pi 64 SL ver 4.13.0 and I keep getting a crash after about five to ten minutes. This program was running fine on a 32bit system with runtime 4.8 previously but they upgraded the panel PC cause it got smashed. Looking at the logs I see this error "ERROR: GetNetLinkSockAndInfoByMac(): could not open netlink socket: Too many open files" at the time of crash. I do have a UDP socket open for a serial to ethernet adapter and im wondering if maybe its opening a bunch of sockets and while receiving messages, Im not sending anything to the device only receiving. Below is the code used for the UDP VAR // Scale Comm fbPeerServer : NBS.UDP_Peer; ipAddress : NBS.IPv4Address; fbReceive : NBS.UDP_Receive; xPeerActiv : BOOL := TRUE; abyReceive : ARRAY [0..255] OF BYTE; sLastValidReceive : STRING(255); udiIndex : UDINT; END_VAR IF xPeerActiv AND NOT fbPeerServer.xBusy THEN ipAddress.SetInitialValue(ipAddress := gvlSettings.sIPAddres); fbPeerServer(xEnable := TRUE, itfIPAddress := ipAddress, uiPort := gvlSettings.uiPort); END_IF fbPeerServer(); fbReceive(xEnable := fbPeerServer.xBusy, itfPeer := fbPeerServer, pData := ADR(abyReceive), udiSize := SIZEOF(abyReceive)); IF fbReceive.udiCount > 0 THEN IF fbReceive.udiCount < SIZEOF(sLastValidReceive) THEN SysMem.SysMemCpy(pDest := ADR(sLastValidReceive), pSrc := ADR(abyReceive), udiCount := fbReceive.udiCount); // Set End of String sLastValidReceive[fbReceive.udiCount] := 0; END_IF END_IF If anyone as seen this I could really use some help figuring it out. I included the Log report
Last updated: 2024-09-19

Post by gorditron on I2C Communication with CODESYS Forge talk (Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag fĂĽr die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte fĂĽr den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer fĂĽr den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer fĂĽr die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle fĂĽr das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
CODESYS Control for PFC200 4.13.00 CODESYS IIoT Libraries SL 1.11.0.0 Application Based License: CODESYS Control Standard M I have (2) projects with similar code base and both using Wago PFC200. On the second project I am seeing 2 things that I have not been able to resolve: 1) Errors in the log under the Ethernet Item: IoDrvEthernet: [PCI\E1Q51CE62] Could not be found on target! Please check the Ethernet settings. 2) Exception for CPU Load. "Processorload watchdog: plcload=100, maxplcload=95" I have slowed down cyclic tasks on this project, even though on the first project there is actually more code - and it does not exhibit this behavior. In looking at the CPU loading via Linux 'TOP' command there appears to be 20% idle. So plenty of headroom (my opinion). In an effort to troubleshoot I have duplicated the target hardware on my bench. It ran overnight without a CPU load exception. On the test system, I have tried (3) version of the ethernet device. 3.5.16.0 3.5.17.0 and 4.2.0.0 Presently the log does not show the error, but status says the module reports an error. I really do not know if this issue is related to the CPU load exception. The issue does not appear to effect ethernet communications (ModbusTCP or SNMP or Webvisu or PuTTy into Linux Shell). On my test bench I have ModbusTCP slave simulators for all ModbusTCP slaves, but only (1) of the (5) SNMP devices present.
Last updated: 2025-01-21

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23

Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16

Post by gallusrrr on usb2can in Codeysy 3.5 Can Gateway CODESYS Forge talk (Post)
Hallo und guten Morgen, Ich danke fĂĽr die RĂĽckmeldung. ich habe das oben geschriebene durchgefĂĽhrt und auch festgestellt das mit die Commandos fĂĽr die Can befehle noch fehlen. (Google angeschmissen und geschaut auch gefunden) sudo apt-get install can-utils (damit auch jemanden anders der Post hilft) AnschlieĂźend habe ich das CAN System komplett aufgebaut so das ich mit einen anderen CAN Adapter schauen konnte ob die Nachricht auch ankommt. die Nachricht kommt an :) danach habe ich follgende Ausgabe: pi@Codesys:~ $ sudo ip -s -d link show can0 3: can0: <noarp,up,lower_up,echo> mtu 16 qdisc pfifo_fast state UP mode DEFAULT group default qlen 10 link/can promiscuity 0 allmulti 0 minmtu 0 maxmtu 0 can state ERROR-ACTIVE restart-ms 0 bitrate 250000 sample-point 0.875 tq 250 prop-seg 6 phase-seg1 7 phase-seg2 2 sjw 1 brp 12 gs_usb: tseg1 1..16 tseg2 1..8 sjw 1..4 brp 1..1024 brp_inc 1 clock 48000000 re-started bus-errors arbit-lost error-warn error-pass bus-off 0 0 0 0 0 0 numtxqueues 1 numrxqueues 1 gso_max_size 65536 gso_max_segs 65535 tso_max_size 65536 tso_max_segs 65535 gro_max_size 65536 parentbus usb parentdev 1-1.4:1.0 RX: bytes packets errors dropped missed mcast 3549 819 0 0 0 0 TX: bytes packets errors dropped carrier collsns 32 4 0 0 0 0</noarp,up,lower_up,echo> (Sorry habe kein Speicherplatz im Web um Bilder anzuzeigen..) man kan sehen das die Nachricht abgeht und auch 32 Byte Empfangen worden sind. Die nachricht ist auch am anderen CAN Adapter sichtbar gewesen. Wie bekomem ich den einrichteten Adapter in Codesys rein? das ich den Befehl sudo ip link set can0 up type can bitrate 500000 das ich die Einrichtungs des Can Adapters noch in die Rasperry Start rutine nehmen muss ist mir klar. Ich bedanke mich .
Last updated: 2024-01-18

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I updated the docker container runtime to version 4.11.0.0. and build the container with this "Dockerfile" FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.11.0.0" ENV EDGE_VERSION "4.11.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package '*codemeter*.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package '*codesyscontrol*.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codemeter start && /etc/init.d/codemeter-webadmin start && /etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"] Now cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 8.00 of 2023-Nov-28 (Build 5967) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. But still CODESYS development system reports that it needs a dongle and when I click install that "value cannot be null. Parameter name: containerToLicenses" It seems that Codemeter is forced to look for a dongle instead of a CMsoftcontainer. Can you confirm that CODESYS licensing works also when CODESYS is installed in a Docker container?
Last updated: 2024-03-21

Post by leandroct on Error reading files after runtime update from 4.0.0.0 to 4.8.0.0 CODESYS Forge talk (Post)
Since version 19 they changed how file access is handle. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 The CodesysControl.cfg is at C:\ProgramData\CODESYS\CODESYSControlWinV3x64\xxPROJECT_NUMBERxx\ Here the email they sent me: "with the 3.5.19 Version we changed how files are handled. See following issue: CDS-81506 - CODESYS Control SysFile system file access vulnerability. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 Here is the official release-note: [[COMPATIBILITY_INFORMATION]] With the activation of ForceIecFilePath the file access from IEC is now restricted to the configured paths only (file sandbox)! [SysFile] ForceIecFilePath=1 (new default) The standard path is the current directory, the PlcLogic subfolder or a configured path. Every file access outside of this path is configured via PlaceholderFilePath, for example access to temporary files or removable media: [SysFile] PlaceholderFilePath.1=/tmp, $TMP$ PlaceholderFilePath.2=/media/usb, $USB$ PlaceholderFilePath.2.Volatile=1 For more information see our tutorial FilePath & Placeholders. To restore the old behavior ForceIecFilePath may be configured as follows: [SysFile] ForceIecFilePath=0 BUT WE HIGHLY RECOMMEND TO LEAVE THIS SETTING AT ITS NEW DEFAULT VALUE! "
Last updated: 2024-05-07

Post by wildcard on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13

Post by manuknecht on Opening a Dialog on a specific Client from ST CODESYS Forge talk (Post)
I managed to find a solution that seems to work reliably. As the VU.Globals.CurrentClient-filter accesses the CURRENTCLIENTID or at least a similar, internal variable it can only be used if called from a certain client (e.g. from a button in a visualization). My solution works by implementing a new client filter that compares the client ID of all clients to the ID of the last client that was used. The variable containing the data of the last client is defined as: G_LastClient : VU.IVisualizationClient; // Copy of last client that detected click This last client is then updated every time a button is pressed using the Execute ST-Code input configuration of the button: G_LastClient := VU.PublicVariables.Clients.Current; Next, I created a function block that implements the client filter interface as so: FUNCTION_BLOCK FB_LastClientFilter IMPLEMENTS VU.IVisualizationClientFilter VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR END_VAR Then i added a method to the FB called IsAccepted which is used to filter out the client. When creating the method, it should automatically be filled with the according variable declaration, as it is defined in the interface: (* For every client can be desided, if it is accepted. ``TRUE``: Client is accepted*) METHOD IsAccepted : BOOL VAR_INPUT (* The client, to check*) itfClient : VU.IVisualizationClient; END_VAR Now the client can be compared to the last used client as such: // check if clientID corresponds to clientID of last recorderd client IF itfCLient.ClientId = G_LastClient.ClientId THEN IsAccepted := TRUE; ELSE IsAccepted := FALSE; END_IF To make use of this custom client filter, initialize a variable with the client filter: LastClient : FB_LastClientFilter; // Client filter to find last used client Then use this client filter when opening or closing a dialog from ST: fbOpenMyDialog(itfClientFilter:=LastClient,xExecute:=TRUE,sDialogName:='VIS_MyDialog_DLG');
Last updated: 2023-09-27

Post by tcarlbom on Read tag values using external program CODESYS Forge talk (Post)
This is my first time posting in this forum and I am new to codesys. I am a fullstack developer and I am trying to figure out how the following. What would be the best approach to create a own/custom tag browser? Either directly in codesys ide or using a separate custom program (perhaps a winforms application). 1.a. Shall I parse the .project xml file to get a list of all tags in the project? 1b. Shall I use python scripting in codesys ide to get a list of tags? Once one have selected some tags. These tags shall be exposed to a python program which will be acting as a edge computer. It’s fine to be able to import a file. 2a. I found a library called codesys plchandler which (as I understand) acts a rest api server. Is this correct? If so, can I query the api from a custom python script, ie can query what tags exist in project and or read tag values? My research so far. From earlier projects I know that using opc ua would be perfect for this but from my opinion it’s bloating the plc since it’s resource intensive. So opc ua is not an option. Codesys automation server is neat. But I don’t want to rely on some cloud services and subscription based pricing. There seem to be several interesting codesys libraries like mqtt, tcp server and NVL sender which would help me expose plc tags. But all have a common problem. One have to manually write what tags which will be used in these function blocks. I want a similar experience like “selecting” tags in the opc ua or the codesys tracing, ie a tag browser.
Last updated: 2024-06-28

Post by youness on No source code available (cip object) CODESYS Forge talk (Post)
Hi yotaro, hope your problem was resolved. I had the same, but with an other library title. This exception is not detected during compilation, but rather at a given position in the program (when switching to a given visualization). Although the exception is generated at this point, it does not involve the visualization in question. This error is due to one of 3 reasons: 1) A division by zero somewhere: The program is able to detect divisions by zero at compile time. But in the case of a variable, which takes a valid value at init and changes to 0 at a later stage. 2) An invalid pointer: (either because it has a value of 0, or because it points outside the memory reserved for the program) is being dereferenced. Locate any pointers or interfaces you have in the code and check them - you should also be wary of mixing inline modifications and pointers. 3) Array overflow: Generally when a processing operation is executed outside the array's definition range. Example: a write loop with n iterations is executed on an array of dimmension n-1. On the other hand, the error message may not appear. In the latter case, the error may have fatal consequences, as the overflow has induced writing to potentially forbidden memory areas. This problem can be explained by the fact that it's not always the adjacent memory areas of PLC_PRG that are overwritten, but the memory areas that are randomly allocated to the array during compilation. In this case, however, there is no entry in the log, so you need to integrate the "Implicit Check function", which checks the line of code generating the error. To integrate this functions, click on Application --> POU for implicit controls Regards,
Last updated: 2024-07-16

Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14

Post by fmon on Modbus TCP client reconnection problem CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED". Is it normal ? It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus client reconnection. What is different at the first client connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-17