Post by trycyclepower on Only single ehternet ip drive is communicating
CODESYS Forge
talk
(Post)
Hi all, I have two ethernet IP drives not communicating together. If I disable one, then other one starts working. ENIPScnannerIOTak cycle is setup as 20ms. Also, PLC updating variables setting is on.
Last updated: 2024-03-08
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
to fix this I used a sp17 codesys and changed the project setting softmotion version to 4.6.2.0. I'm not sure if I should have had such difficulties but it works now.
Last updated: 2024-04-21
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
to fix this I used a sp17 codesys and changed the project setting softmotion version to 4.6.2.0. I'm not sure if I should have had such difficulties but it works now.
Last updated: 2024-04-21
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5
CODESYS Forge
talk
(Post)
the project has only one OneWire Master - so if you add the setting "PlaceholderFilePath.2=/sys/devices/w1_bus_master2, $OneWire2$ to the config file it will fail and the Ethercat task will be blocked by the OneWire Master readings?
Last updated: 2025-10-21
Post by eschwellinger on EtherCAT status errors
CODESYS Forge
talk
(Post)
Setting IRQ priorities using shell commands irq-list and irq-set-prio for the network adapter which is used for Ethercat. This is here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization_linux.html
Last updated: 2025-11-25
Post by julianramirez on Codesys Trend - setting Y axis minimum and maximum as variables - error
CODESYS Forge
talk
(Post)
Hello Hannibal, I am using real vars and it works, however, if I update those vars in real time it doesnt quite change it on y axis, do you think it is because it is not an integer?
Last updated: 2026-05-21
Post by george32 on TCP Server
CODESYS Forge
talk
(Post)
Thank you for your advice Rinie, I have tried to follow this example but found one problem.When I disconnect with Hercules the system does not acknowledge the lost of its connection this could result in critical errors. Because of this error I am trying to implement the Syssocket library. With this library I am having a problem which I could not solve. I have the following code: ip_adres : STRING :='0.0.0.0'; port : WORD := 5000; iStep : INT := 1; // Socket information Socket_handler : SysSocket_Interfaces.RTS_IEC_HANDLE; Socket_handler_result : SysSocket_Interfaces.RTS_IEC_RESULT; Socket_adress : SysSocket_Interfaces.SOCKADDRESS; Addres_Convert : SysSocket_Implementation.RTS_IEC_RESULT; // Bind information Bind_handler : SysSocket_Interfaces.RTS_IEC_RESULT; // Listener Information Listener_handler : SysSocket_Interfaces.RTS_IEC_RESULT; Addres_Convert := SysSocket_Implementation.SysSockInetAddr(szIPAddress:= ip_adres,pInAddr:= ADR(Socket_adress.sin_addr)); Socket_adress.sin_family:= SysSocket_Interfaces.SOCKET_AF_INET; Socket_adress.sin_port := SysSocket_Implementation.SysSockHtons(usHost:= port); CASE iStep OF 1: // Create Socket Socket_handler :=SysSockCreate( iAddressFamily :=SysSocket_Interfaces.SOCKET_AF_INET, diType:=SysSocket_Interfaces.SOCKET_STREAM, diProtocol:=SysSocket_Interfaces.SOCKET_IPPROTO_TCP, pResult:=ADR(Socket_handler_result)); IF Socket_handler = SysSocket_Interfaces.RTS_INVALID_HANDLE THEN iStep := 1; ELSE iStep := 2; END_IF 2: Bind_handler := SysSocket_Implementation.SysSockBind( hSocket:=Socket_handler, pSockAddr :=ADR(Socket_adress), diSockAddrSize:=SIZEOF(Socket_adress) ); 3: Listener_handler := SysSocket_Implementation.SysSockListen( hSocket :=Socket_handler, diMaxConnections :=1); END_CASE When I am trying to get this working, the SysSockBind function gives a value of 16#207 which means adress already in use. I find this weird because of the IP-adress of 0.0.0.0. I think I am converting the Ip-adress in the wrong way, but the code does not give a error arround this. So therefore I cannot find the solution to this problem. I hope someone could help me with this problem. Thanks in advance George
Last updated: 2025-02-20
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by dclements on Feature Request: Read-Only References / Pointer-to-Const Support
CODESYS Forge
talk
(Post)
I would like to suggest adding support for persistent read-only references or pointers in CODESYS, similar to a C++ pointer-to-const (const T*). For example, something conceptually similar to: POINTER TO CONSTANT ST_MyData or REFERENCE TO CONSTANT ST_MyData The important distinction is that the reference itself may still be passed around or reassigned, but the referenced object cannot be modified through that reference. CODESYS currently supports VAR_IN_OUT CONSTANT, which provides read-only reference semantics for parameters, but there does not appear to be an equivalent type that can be stored in a variable or returned from a method. A practical use case is a registry that owns long-lived definitions. The registry needs to retain ownership of the data while downstream systems maintain persistent references to it. Currently, the main options are: Return the struct by value, which loses reference semantics and requires a copy. Return POINTER TO ST_Definition, which allows consumers to modify registry-owned data. Convert the structure into a Function Block and expose a getter-only interface, which provides the desired encapsulation but introduces more complexity and memory overhead. A read-only reference/pointer type would allow libraries to expose persistent, zero-copy access to internally owned data while preserving encapsulation. This would be particularly useful for library APIs and object-oriented CODESYS architectures where ownership of data should remain with one component while other components are allowed to observe it. Similar requests for constant references/pointers have been discussed on CODESYS Forge previously, so this appears to be a recurring use case rather than something specific to one application.
Last updated: 2026-09-01
Ranges, Lambdas, on Fixed arrays of structs
CODESYS Forge
talk
(Thread)
Ranges, Lambdas, on Fixed arrays of structs
Last updated: 2023-08-31
Save jitter measure of main task in file
CODESYS Forge
talk
(Thread)
Save jitter measure of main task in file
Last updated: 2020-08-07
Ged rid of lines on Chart XY
CODESYS Forge
talk
(Thread)
Ged rid of lines on Chart XY
Last updated: 2022-04-05
Resolution of visualization (for RPi's LCD 800x480)
CODESYS Forge
talk
(Thread)
Resolution of visualization (for RPi's LCD 800x480)
Last updated: 2015-11-22
The configuration file of the PLC
CODESYS Forge
talk
(Thread)
The configuration file of the PLC
Last updated: 2016-04-11
Where is data of ENIP getAttributeSingle stored?
CODESYS Forge
talk
(Thread)
Where is data of ENIP getAttributeSingle stored?
Last updated: 2023-04-20
Encryption of application and communication not working
CODESYS Forge
talk
(Thread)
Encryption of application and communication not working
Last updated: 2021-11-04
Adding a scaling factor to text sizes of different languages
CODESYS Forge
talk
(Thread)
Adding a scaling factor to text sizes of different languages
Last updated: 2017-03-31
The intent of two Library Managers in a Project
CODESYS Forge
talk
(Thread)
The intent of two Library Managers in a Project
Last updated: 2016-08-22
Initialization of visualization variables and cyclic code execution
CODESYS Forge
talk
(Thread)
Initialization of visualization variables and cyclic code execution
Last updated: 2023-10-01
Access project information of references library by script
CODESYS Forge
talk
(Thread)
Access project information of references library by script
Last updated: 2023-10-23
License status of Linux 64Bit runtime via CLI
CODESYS Forge
talk
(Thread)
License status of Linux 64Bit runtime via CLI
Last updated: 2023-12-04
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.