Post by eschwellinger on Codesys Tools Update Raspberry ist nicht vorhanden aktualisieren im Geraete ansicht geht auch nicht
CODESYS Forge
talk
(Post)
Hallo Alex, hier im Deploytool gibt man nur an welches Packet man installiert - das deploy Tool schaut auf dem Zielsystem: Ist es ein Arm64 oder Arm 32 System: Abhängig davon wird für 64Bit: Für Pi MC: armv7l Für Pi SL: armv6l Für Pi 64: aarch64 Beispiel Pi 64B it OS [CmpRasPi] Architecture=aarch64 in /etc/codesyscontrol/CODESYSControl_User.cfg gesetzt. Sprich wenn du das ändern willst kannst du das in diesem Config File ändern oder aber hier im Deploy Tool:
Last updated: 2025-01-23
Post by respl on IFM EXOR Network variable Error
CODESYS Forge
talk
(Post)
We are connected IFM CR711S to Exor EX710. We are exchanging data using network variables. Both devices are configured on same project so no need to use file source. When tested application it works fine. But after 3 months same application not working. We are able to send data from CR711 to EX710 but data from Ex710 to CR711s works only for one scan when we cold reset CR 711S. Can somebody help to find out error.
Last updated: 2025-03-17
Post by simone on Preferred way of managing Ip-adress/es for linux (debian) host?
CODESYS Forge
talk
(Post)
Hi pernockham, I think you should ask your device vendor. For some time I used one from an Italian company where they had made a library where you can manage the ip with a function (something like SetIPAddr...), it was based on connmann on linux. From my little experience is better to use the "default" way, so for me is to manage the config file on interfaces or use the ip addr utility
Last updated: 2025-03-24
Post by ggis on Manage Gateways between different CODESYS IDE versions
CODESYS Forge
talk
(Post)
Hi, I'd like to share the list of gateways between different versions (and sandboxes) of Codesys IDE. I refer to the list that is managed in Device > Communication Settings (as described in https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_edt_device_communication_settings.html ) Can I export/import that list? Or is there a file that I can copy from one installation to another one? Thank you GG
Last updated: 2025-05-28
Post by berkdan on SMC_ReadNCFile2 is always busy
CODESYS Forge
talk
(Post)
Hello, I’m using CODESYS V3.5 SP18. When I try to use SMC_ReadNCFile2 to read the file /PlcLogic/gcode.nc, the function block's bBusy output remains TRUE indefinitely. Can you help me understand what I might be doing wrong? Here is how I’m calling the function block. The value of strFileName is 'gcode.nc'. fbReadFile( bExecute := bExecute, sFileName := strFileName, bAbort := bCycleStop, fDefaultVel := RetainVariables.xSlowVelocity, fDefaultAccel := RetainVariables.xAcc, fDefaultDecel := RetainVariables.xDec, b3DMode := TRUE, bParenthesesAsComments := TRUE, fDefaultVelFF := RetainVariables.xFastVelocity, fDefaultAccelFF := RetainVariables.xAcc, fDefaultDecelFF := RetainVariables.xDec, ErrorID => gCNC.eErrorId, errorPos => gCNC.eErrorPos, ErrorProgramName => gCNC.eErrorProgName, bBusy => bReadFileBusy, sentences => sentencesss ); Thanks in advance for your help.
Last updated: 2025-06-16
Post by nguyenkhoi on Omron R88D-KN08H-ETC with a raspberry on top... (over ethercat)
CODESYS Forge
talk
(Post)
hi everyone, continuing the part about omron g5 axis and nx-ecc201 omron, but i have a problem with not being able to scan with "model with Z code suffix of omron china", it seems that the available softmotion file is not fully compatible mapping, often causing ethercat communication error DC distributed clock after every 10-12 hours of continuous running! omron driver: R88D-KN08H-ECT-Z
Last updated: 2025-07-01
Post by manuknecht on Persistence Manager does not save alphabetically first value
CODESYS Forge
talk
(Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17
Post by umdee on Error when monitoring LAD programs
CODESYS Forge
talk
(Post)
System Information from the computer being used: OS Name Microsoft Windows 11 Pro Version 10.0.22631 Build 22631 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Manufacturer Dell Inc. System Model Latitude 5500 System Type x64-based PC System SKU 08B9 Processor Intel(R) Core(TM) i7-8665U CPU @ 1.90GHz, 2112 Mhz, 4 Core(s), 8 Logical Processor(s) BIOS Version/Date Dell Inc. 1.3.11, 6/11/2019 SMBIOS Version 3.2 Embedded Controller Version 255.255 BIOS Mode UEFI BaseBoard Manufacturer Dell Inc. BaseBoard Product 0M14W7 BaseBoard Version A00 Platform Role Mobile Secure Boot State On PCR7 Configuration Elevation Required to View Windows Directory C:\WINDOWS System Directory C:\WINDOWS\system32 Boot Device \Device\HarddiskVolume1 Locale United States Hardware Abstraction Layer Version = "10.0.22621.2506" User Name CARDASSIA-IX\Engineer Time Zone Eastern Daylight Time Installed Physical Memory (RAM) 16.0 GB Total Physical Memory 15.8 GB Available Physical Memory 4.67 GB Total Virtual Memory 18.5 GB Available Virtual Memory 2.52 GB Page File Space 2.63 GB Page File C:\pagefile.sys Kernel DMA Protection Off Virtualization-based security Not enabled Windows Defender Application Control policy Enforced Windows Defender Application Control user mode policy Off Device Encryption Support Elevation Required to View Hyper-V - VM Monitor Mode Extensions Yes Hyper-V - Second Level Address Translation Extensions Yes Hyper-V - Virtualization Enabled in Firmware Yes Hyper-V - Data Execution Protection Yes
Last updated: 2024-03-19
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20
Post by william-blandon on RecipeManCommands.ReloadRecipes
CODESYS Forge
talk
(Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23
Post by simone on Cannot connect to webvisu on localhost
CODESYS Forge
talk
(Post)
As I wrote before on the title, I have difficulties to connect to see webvisu from localhost. The story: while waiting for the plc+hmi to arrive, I'm preparing the software, mainly the visual parts trough the control Win3 x64 (same version as the ide 3.5.20.10). The problem is that I can't see the webvisu with the installed webbrowser. I don't know if this is a problem, but I changed the port to 9001 (randomly "free") because 80, 8000, 8080, 8088, 3000 are all occupied by other projects (all on the Apache server). Is there something wrong with the config file? This is the url: localhost:9001/webvisu_app.htm and here the config file part "CmpWebServer". [CmpWebServer] ;The handling of startup/shutdown of the webserver: ;0->automatically start, shutdown only on shutdown of the runtime;1->automatically start, could be shutdown on demand ;2(default)->start/shutdown on demand;3->start on demand, shutdown only on shutdown of the runtime StartupType=0 ;The TCP port the webserver listens on WebServerPortNr=9001 LocalAddress=localhost ;LocalAdapterName=LAN-Connection LocalAdapterName=EthernetPCPLC ;LocalAdapterNameUnicode=L\00A\00N\00-\00C\00o\00n\00n\00e\00c\00t\00i\00o\00n\00 LocalAdapterNameUnicode=E\00t\00h\00e\00r\00n\00e\00t\00P\00C\00P\00L\00C\00 Thanks for all the help!
Last updated: 2024-07-11
Post by solve-it on SysFileOpenAsync
CODESYS Forge
talk
(Post)
Just realized that it is the /dev/input/js0 file. Don't think this is a prob either. Found the ConfigFile. Where and how to add /dev/input/js0? raspberry [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 [SysTarget] TargetVersionMask=0 TargetVersionCompatibilityMask=0xFFFF0000 [CmpLog] Logger.0.Name=/tmp/codesyscontrol.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=1000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC [CmpSettings] FileReference.0=SysFileMap.cfg, SysFileMap FileReference.1=/etc/CODESYSControl_User.cfg [SysExcept] Linux.DisableFpuOverflowException=1 Linux.DisableFpuUnderflowException=1 Linux.DisableFpuInvalidOperationException=1 [CmpWebServer] ConnectionType=0 [CmpOpenSSL] WebServer.Cert=server.cer WebServer.PrivateKey=server.key WebServer.CipherList=HIGH [SysMem] Linux.Memlock=0 [CmpCodeMeter] InitLicenseFile.0=3SLicense.wbb [SysEthernet] Linux.ProtocolFilter=3 [CmpSchedule] ProcessorLoad.Enable=1 ProcessorLoad.Maximum=95 ProcessorLoad.Interval=5000 DisableOmittedCycleWatchdog=1 [CmpUserMgr] AsymmetricAuthKey=6873d655ac1f166f3743feea42d2f3dd1b39ae40 [CmpSecureChannel] CertificateHash=09fd8d52be4ddd45a709bc9c95e2aa093b3f5695 [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpMask=1 ;raspberry [ComponentManager] ;Component.1=CmpGateway ;Component.2=CmpGwCommDrvTcp ;Component.3=CmpGwCommDrvShm [SysCom] ;Linux.Devicefile=/dev/ttyS [CmpBlkDrvCom] ;Com.0.Name=MyCom ;Com.0.Baudrate=115200 ;Com.0.Port=3 ;Com.0.EnableAutoAddressing=1 [SysProcess] Command.0=shutdown [CmpApp] Bootproject.RetainMismatch.Init=1 ;Application.1=Application ;Application.1=Application ;Application.1=Application Application.1=Application [CmpRasPi] Architecture=armv6l [CmpRedundancyConnectionIP] [CmpRedundancy] [CmpSrv] [IoDrvEtherCAT]
Last updated: 2024-07-16
Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3
CODESYS Forge
talk
(Post)
Some findings on this issue: PEAK CAN Driver is the same as in every PCI card from PEAK. I updated the inf file. Here are my steps: 1. Include right VendorID into the *.inf file 2. Disable Windows driver check (Disable WHQL check). This you need because 3S driver is not certified. You will find steps via google or ask chatgpt :) 3. Select: Select driver from a list and navigate to the folder. Say yes to install an uncertified driver. 4. Driver installed and device without errors I did the same with CAN Card from ESD, but here you dont need to include the vendor ID. In ANY CASE it was not successful. The RTIOwdmgeneric is not available in Codesys or anyhow accassable :( I wonder that it fails in two cases, two suppliers, two driver in the same way. How can RTIOwdmgeneric implemented into the project?
Last updated: 2024-12-20
Post by pernockham on Persistence Manager: Config File not found?
CODESYS Forge
talk
(Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20
Post by laurits on Max lines of code, codesys CNC ?
CODESYS Forge
talk
(Post)
Hi, okay here's the project, it's a modified version of "CNC Example 10: Programming Dynamic CNC Paths", no need for G Code text file (i have also tried with G code text file, same problem) in "PROGRAM PLC_PRG" you can set bStart to true, and the program should start running, go to "PROGRAM CNC" and you can see axis moving. lrXpos := IoConfig_Globals.XAixs.fSetPosition; lrYpos := IoConfig_Globals.YAxis.fSetPosition; Now you can can change the number of movements in the the "PROGRAM PLC_PRG" From this number of movements in "program PLC_PRG" BUF : ARRAY[0..32010] OF SMC_GEOINFO; xp : ARRAY[1..32000] OF REAL; yp : ARRAY[1..32000] OF REAL; to this number to this number of movements BUF : ARRAY[0..132010] OF SMC_GEOINFO; xp : ARRAY[1..132000] OF REAL; yp : ARRAY[1..132000] OF REAL; Now if you start the program again you should see an error in the "sMC_Interpolator: SM3_CNC.SMC_Interpolator;" function block Let me know if you can not get it running.
Last updated: 2025-06-03
Post by kevintumibay on Struggling to connect to EK1100 to Raspberry Pi
CODESYS Forge
talk
(Post)
SUMMARIZED VERSION OF QUESTION: I'm trying to connect a Raspberry Pi running "Codesys Control for Raspberry Pi" to a Beckhoff EK1100, unfortunately, when I try to connect I get the following messages SEE FIRST PICTURE DETAILED VERSION OF QUESTION: Hi everyone, I'm a college student that is super interested in learning about PLCs. I wanted to dive into the subject and decided to follow this great Instructables article: https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/ Thank you in advance for your help! My current setup is as follows: 1. I have Codesys Control for Raspberry Pi, version 4.14.0.0, (https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html) installed on a Raspberry Pi 3B. 2. I am using my smartphone hotspot to create a network. 3. I have CODESYS 3.5 SP21 (64 bit) installed on my Windows 11 laptop. 4. Both the Raspberry Pi and my laptop are connected to the smartphone hotspot network (I am wirelessly connecting to the Raspberry Pi). Connecting to the Raspberry Pi from CODESYS on my laptop: 1. I launch Codesys Installer -> I install Codesys Control for Raspberry Pi (link to the software). 2. I launch Codesys 3.5 SP21 (64 bit) on my laptop. 3. I go to file --> new project --> standard project --> in the pop-up I select "Codesys Control for Raspberry Pi" and "Structured Text" 4. I click on tools -> Deploy Control SL (on older versions of Codesys you would click on "update Raspberry Pi", I got that information from this video: link) 5. Inside Deploy Control SL --> I go to the "communication" menu and I input the IP address of my Pi, the password, and click on connect. 6. Inside Deploy Control SL --> I go to the "deployment" menu and I install Codesys Control for Raspberry Pi SL and Codesys Edge Gateway for Linux 7. Now I double click on "device" in the left hand tree and put in the IP address of my Raspberry Pi and click on connect --> success! I am able to connect! SEE SECOND PICTURE Powering the EK1100 and connecting it to the Raspberry Pi: 1. I am supplying the EK1100 with 24 V across the + and - pins. 2. I have jumper wires going from the + pin to the 24V pin and from the - pin to the 0V pin. SEE THIRD PICTURE 4. I am pretty confident that the EK1100 is receiving power because the "LED Us 24 V" and "LED Up 24 V" are lighting up. 5. I then run an ethernet cable from the EK1100 to the Raspberry Pi port (the Raspberry Pi is connected to my laptop wirelessly over WiFi). I think this connection should also be good since the LINK/ACT LED lights up. Trying to connect to the EK1100: 1. Back in Codesys I right-click on "Device" in the left tree and then in the pop up I click on "add device". 2. I then click on EtherCAT Master. 3. Next in a terminal window I SSH into the raspberry Pi and run the "ifconfig" command. 4. From there I get the MAC address for eth0 --> in my case: b8:27:eb:29:a9:25 5. Then, back in Codesys I double click on "EtherCAT Master" in the left hand tree. I then paste the MAC address into the "Source Address (MAC)" field. 6. I go to the Beckhoff official website and download the XML files for EtherCAT: https://www.beckhoff.com/en-en/products/i-o/ethercat-terminals/ek1xxx-bk1xx0-ethercat-coupler/ek1100.html? 7. I unzip those files in my computer into some folder that I can remember. 8. Back in Codesys I click on "Tools" --> "Device Repository" --> "Install" --> and then on the "Beckhoff EK11xx.XML" file. 9. In theory the necessary XML file is now installed. 10. THIS IS WHERE I RUN INTO THE PROBLEM: I then click on login --> I right click on EtherCAT_Master and then scan for devices --> and nothing. 11. It just doesn't detect it. On top of this whenever I login I get those orange triangles on the left on my tree. When I check the Log I get the messages at the very first screenshot of this post. SEE FOURTH PICTURE Solutions that I have tried to resolve this problem: 1. I thought it was maybe the .XML file so I installed all the .XML files from the EtherCAT folder that I downloaded. That didn't fix it. 2. I went on the Wayback Machine and got the .XML files from 2018 as I thought maybe an older version would work. This file of EtherCAT folders had a .XML file named "Beckhoff EKxxxx.XML" I thought this would work because that's the name of the file the guy in the Instructables used (https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/). That didn't do anything. 3. I ran the PLC on my computer instead of the Raspberry Pi and tried to connect to the EK1100, in case the issue was with the Raspberry Pi, but I still ran into the same error from the picture above: "Attention! The device was not found in the repository. Vendorcode: 0x0. Productcode: 0x0. Revision: 0x0". SEE FIFTH PICTURE 4. I reinstalled Codesys, I was originally on version 3.5 SP20 when I did this, I upgraded to 3.5 SP21 with no success. 5. I then thought the solution might be to first add the EK1100 hardware before connecting so I did the following: 6. Right click on "EtherCAT Master" on the left hand tree --> then click on "add device" --> then I added the "EK1100 EtherCAT Coupler (2A E-Bus)" MY THEORY OF WHAT IS CAUSING THE PROBLEM: I asked ChatGPT for help and it said that it might have something to do with the revision number. On the physical EK1100 it says "Rev. Nr.: 0018". I believe that this means that I need to a revision 0018 XML file but if you look in Codesys it says the version is 16 (picture above). This is confusing because I got my .XML file from the official Codesys website so it should be the most up to date version possible. I searched and I searched and I couldn't find a version 18 .XML file, I don't even now if this exists. Any help you can provide is greatly appreciated, I don't know what to do anymore and I really really want to get this working. Thank you!
Last updated: 2025-03-30
Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
I have a project with several buttons and dialogs. Most of the dialogs are opened using the Open Dialog action of the Input configuration of the buttons. Some dialogs are openend using the FbOpenDialogExtended FB of the Visu Utils library and the FbOpenDialogExtended FB is called in the Execute ST-Code action. I am also using the FileOpenSave dialog from Visu Dialogs which requires an OnDialogClosed action to read out. I realized that the OnDialogClosed action which is meant for the FileOpenSave dialog also triggers if a dialog is closed, which was previously openend using the FbOpenDialogExtended FB. Is there a way to detect which dialog was closed last and specify to which dialogs the OnDialogClosed action reacts?
Last updated: 2023-09-20
Post by ellcap on Did a library update and now can't open project
CODESYS Forge
talk
(Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25
Post by damian177 on Codesys V3.5 + Pixtend v1.3 + RaspberryPi
CODESYS Forge
talk
(Post)
Hi, I use Pixtend v1.3 with my RaspberryPi with Codesys V3.5 SP15 Patch1. Actually in my project I used two packages: - CODESYS Contro for Raspberry PI 3.5.15.10 - PiXtend for CODESYS 1.3.8.0 Now I would like to extend my project about the IIot Libraries SL package, I installed them. Next I added SMS_Service_SL 1.0.0.8 version library and I have problem with compile my project because I get error: [ERROR] PiXtend_DemoProject_q: Library Manager [Device: PLC Logic: Application]: Could not open library '#CAADTUtil'. (Reason: The placeholder library 'CAADTUtil' could not be resolved.) Any have idea what can I do to properly add SMS library to my project?
Last updated: 2023-09-26
Post by ofey on Modbus TCP communication
CODESYS Forge
talk
(Post)
Hi! I tried setting up the PLC I'm working with (Beijer GN-9373) to connect to a modbus master running on a laptop. I have an ethernet connection (via USB-C to ethernet) between the laptop and the controller. I have tried following tutorial on how to set this up. I have added an ethernet device with the IP-address of the PLC. Further I added a ModbusTCP_Slave_Device with default settings. I get the error "Failed to open TCP Port: 1" when I try to go online with the PLC. Earlier I tested the exact same set up with the soft PLC from codesys. I can then read/write values correctly with the Modbus master i have running on the laptop. Hope anybody can help me with this, thanks in advance!
Last updated: 2023-10-06
Post by dhumphries on install codesys runtime on linux
CODESYS Forge
talk
(Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04
Post by wiresplus on How to Connect / Go Online without re-downloading the project
CODESYS Forge
talk
(Post)
Hello, I have a PLC in a remote location. I can connect to it, but when I use a different PC, it asks me to re-download to the PLC - which will a) interrupt production and b) cause version issues. Codesys being open-source, if someone else has made changes, I need to be able to connect, upload the current project, compare it with mine and then decide what next. Every time I connect, it says Warning: An application 'Application' is currently in RUN mode on the PLC. As there is no matching compile information, this existing application needs to be replaced. Click 'Yes' to download the latest code or 'No' to abort. What am I doing wrong?
Last updated: 2024-04-13
Post by installwhat on C0077 on one machine but not another
CODESYS Forge
talk
(Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11
Post by ron-rp on Errors with VisuUserManagement library
CODESYS Forge
talk
(Post)
Hi all, I've played a bit with the VisuUserManagement library, and some other security option in my project, and I started getting this error when logging in - see attached pic. something to do with a specific screen in the library - VUM_Login. Also, Codesys started to ask me to log in to the library when logging in, asking to log in as user of the groups Maintainer or Owner, which I dont know either users (attached pic). when I close the login screen and try to log in to the PLC again, everything works again until I close and open Codesys. I do use user and password to login to the PLC, and this login screen is fine I know the user and pass I setup. anyone know what did I do wrong here and how to fix it?
Last updated: 2024-06-25
Post by abrarsk on SysCom Library Usage
CODESYS Forge
talk
(Post)
Hello all, I am facing issues with using SysCom library. With SysCom23 library things were simple but since we are migrating to 64bit systems, I am writing a Porting program. With SysCom23, opening the comport was as simple as providing the ComPort no. which returns the Handle as a DWORD. dwHandle:=SysComOpen(Port); But the new library is a bit different. It is asking for 2 input parameters to open the Com Port - Port Number and POINTER to RTS_IEC_RESULT IF hCom = 0 THEN hCom := SysComOpen(ComSettings.sPort, ADR(pResult)); How should I use the RTS_IEC_Result? I can find RTS_IEC-REUSLT under SysType2Interfaces of SysCom library. Also, can someone give me a general understanding of this RTS_IEC_REULT and RTS_IEC_HANDLE, etc.?
Last updated: 2024-08-05