Visu Symbols and target visu
CODESYS Forge
talk
(Thread)
Visu Symbols and target visu
Last updated: 2018-07-13
SMC_NCInterpreter with SMC_RoundPath and SMC_ToolRadiusCorr
CODESYS Forge
talk
(Thread)
SMC_NCInterpreter with SMC_RoundPath and SMC_ToolRadiusCorr
Last updated: 2020-05-18
System Date and Time Function
CODESYS Forge
talk
(Thread)
System Date and Time Function
Last updated: 2024-01-05
System libs and I/O Drivers
CODESYS Forge
talk
(Thread)
System libs and I/O Drivers
Last updated: 2024-02-02
Socket communication with username and password
CODESYS Forge
talk
(Thread)
Socket communication with username and password
Last updated: 2024-02-24
Raspberry and problem with runtime
CODESYS Forge
talk
(Thread)
Raspberry and problem with runtime
Last updated: 2024-02-28
Codesys v3.5 SP11 and Python scripts
CODESYS Forge
talk
(Thread)
Codesys v3.5 SP11 and Python scripts
Last updated: 2024-04-05
OPC-UA and other communication questions
CODESYS Forge
talk
(Thread)
OPC-UA and other communication questions
Last updated: 2024-04-06
CODESYS Control Standard S and Beaglebone
CODESYS Forge
talk
(Thread)
CODESYS Control Standard S and Beaglebone
Last updated: 2024-05-11
Data source and safety PLC
CODESYS Forge
talk
(Thread)
Data source and safety PLC
Last updated: 2024-06-17
Get DataSources Items list and status
CODESYS Forge
talk
(Thread)
Get DataSources Items list and status
Last updated: 2024-06-18
Wbm/runtime and visualization login
CODESYS Forge
talk
(Thread)
Wbm/runtime and visualization login
Last updated: 2024-06-25
Unhandled exception and refactoring error
CODESYS Forge
talk
(Thread)
Unhandled exception and refactoring error
Last updated: 2025-12-10
CODESYS HMI and 2 monitors
CODESYS Forge
talk
(Thread)
CODESYS HMI and 2 monitors
Last updated: 2026-01-13
Resize and position Numpad/Keypad
CODESYS Forge
talk
(Thread)
Resize and position Numpad/Keypad
Last updated: 2026-04-15
TCP communication and TCP Streams
CODESYS Forge
talk
(Thread)
TCP communication and TCP Streams
Last updated: 2026-06-16
Lenze i950 Servo and WAGO PFC200
CODESYS Forge
talk
(Thread)
Lenze i950 Servo and WAGO PFC200
Last updated: 2026-02-13
Post by martinlithlith on Relay board / relays for raspberry pi 3 b+
CODESYS Forge
talk
(Post)
hi! im planning a project on a raspberry with Codesys. For this I'll need a number of relays to control heating and fans, all a max of 24v and about 2a. How would i know if the board / relays i buy will be working with Codesys? Does every hat work or does it need a library/driver? is there a list of drivers/libraries created? as this is a hobby project all tips on a relay board or single boards that works with codesys and not to expensive are very welcome.
Last updated: 2023-09-03
Post by miodusy on File transfer via visu and codesys automation server
CODESYS Forge
talk
(Post)
I have a problem with the file transfer library. Namely, it does not work via the codesys server. (error 5; overtime, and visualization resets). They operate mostly in local chains. I tested different browsers and VPN from the router. It works everywhere, except through access from the codesys automation server. The client, having many machines under one account, prefers to keep it that way rather than use an individual VPN just to download a backup. Does anyone have an idea what the problem is? Sylwester M.
Last updated: 2024-03-07
Post by androidzz on Json Builder problem?
CODESYS Forge
talk
(Post)
Dear reader, I am using the codesys JSON utilities SL, 1.9.0.0 library. And then specifically the FB JSONBuilder. I need to create a main object with at least 2 objects in it. The first object is no problem, but I cannot insert the second object into the main object. See attached my code and the result I get. I am assuming that I am doing something wrong with the parent index but have tried a lot and can't get it done. Kind regards, Rob
Last updated: 2024-03-11
Post by yannickasselin on How to sort JSON object in codesys
CODESYS Forge
talk
(Post)
Just adding: sSubscriberdata := ''; Right before your memcopy should fix the extra characters. It is because your are copying 36 characters into a string which can contain more than 36 characters and there is garbage left in the extra characters. Regarding the parsing of json, I usually build a structure that mirrors the json data and use the available methods in the IIoT library to parse the data and fill the structure.
Last updated: 2024-05-08
Post by installwhat on C0077 on one machine but not another
CODESYS Forge
talk
(Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11
Post by artem1223 on Synaxis of library declarations in the ST
CODESYS Forge
talk
(Post)
Codesys 3.5 17.30, plc - crevis GN-9373. I need to use RTC of pls for write in registers (need to check difference of writen 100 and 200 registers). For this i try to use SysTimeRtc (SysTimeRtc.SysTimeRtcGet) but its not working. After it i tryed to use SysTimeGetMs and something like this but still not working. Library? Mb but check project, SysTime with SysTimeRtc already, all what i know - already is here. Its my first try to learn ST (early used fbd and ladder, yeah), pls help with it. Mb problem with a syntaxis, but im not sure.
Last updated: 2025-11-26
Post by micik on Using Codesys example problems
CODESYS Forge
talk
(Post)
Hello to all, I'm totally new to Codesys, but I do have some PLC programming experience, mosty with Siemens TIA and STEP7. I have just installed Codesys 3.5. sp19 and I have downloaded example with Ethernet Rockwell 1734AENT. The example can be found here: https://forge.codesys.com/prj/codesys-example/rockwell-1734-c/home/Home/ After opening, I had to manually update devices (Device, Ethernet, IP Scanner, EthernetIP adapter). However, when trying to build the project, I get the following errors: [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library System_VisuElemXYChart has not been added to the Library Manager, or no valid license could be found [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library system_visuinputs has not been added to the Library Manager, or no valid license could be found [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIP]: C0040: Function 'ProcessUpdateConfigurationQueue' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): IoDrvStartBusCycle [IoDrvEtherNetIP]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): Cyclic [GenericServiceUnConnected]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] cip object, 4.4.1.0 (3s - smart software solutions gmbh): ForwardOpenService [ConnectionManager]: C0040: Function 'GetAssemblies' requires exactly '3' inputs [ERROR] iodrvethernetipadapter, 4.4.0.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIPAdapter]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs Compile complete -- 7 errors, 13 warnings Build complete -- 7 errors, 13 warnings : no download possible! What could be the reason for this errors and how to rectify them? Thank you!
Last updated: 2024-02-01
Post by mp9876 on Problem using MeasureFrequence FB
CODESYS Forge
talk
(Post)
Hi everyone, new at Codesys and PLC programming in general. I am using Codesys Win V3.5 SP20 I would like to measure an encoder's frequency output (obtaining that pulse train from Factory IO) and intended to use the MeasureFrequence FB (Intern/CAA/Utilities/CAA Mathematics/3.5.19.0). As mentioned in the title what I need to measure is low frequency, such as lower than 40hz (a cycle every 25mS) or so; I could even go lower frequency if required as this is for test purposes) therefore I am not expecting problem measuring a low frequency with that FB The library in question appears to be installed as I can retrieve it from the Library Repository. I can also see it from the Device's Library Manager. Problem arises when I am trying to instantiate this particular FB. I go like this: VAR MeasF:MeasureFrequence; END_VAR Please note that as soon as I start typing the "MeasureFrequence", the MeasureFrequence comes out as a viable option in auto-typing; seems to indicate that the FB is recognized somehow. But there is no way I can compile this as it comes back with the following: C0046: Identifier 'MeasureFrequence' not defined. Tried to rename that to ABC instead of MeasF; same issue. Possibly that the library is not properly installed ? Placeholder ? I would greatly appreciate a bit of guidance if possible. Thank you and regards, Mike