Search talk: word bit

 
<< < 1 .. 4 5 6 7 8 .. 12 > >> (Page 6 of 12)

Post by tehthoams on Library Search not working CODESYS Forge talk (Post)
Also, Codesys 3.5.19.30 64 bit.
Last updated: 2023-10-17

Post by durstloescher on Codesys Input Detector CODESYS Forge talk (Post)
Perfect, works after a bit Try & Error, Thank you!
Last updated: 2024-02-16

Post by wiresplus on INT_TO_WORD function not working CODESYS Forge talk (Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26

Post by alimans on Hex string CODESYS Forge talk (Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
CODESYS runtime version 4.9.0.0 for your Pi. ssh user should be pi. This is for RasperrPi Os 32 bit. If you are on RasperryPi OS 64Bit use Arm 64bit SL product as Runtime.
Last updated: 2023-09-11

Post by mp9876 on Device User Logon CODESYS Forge talk (Post)
Following up on the invalid user authentication on the target Not 100% sure what the problem was but following my post I managed to create an administrator level user. Then my next issue was that I could not connect to the device. I might have flipped the device from a 64 bit version to a 32 bit version so I did UPDATE DEVICE back to the 64 bit version; still could not connect somehow. Then I did two things at the same time that fixed my problem: Wiped the Codesys Control Win 64 bit version and installed the 32 bit version Installed latest Codesys Control Win V3.5 SP20 (released today) I wish I knew which one of these actions fixed the problem but at least the problem is solved. Hoping this post may help someone one day
Last updated: 2024-03-19

Post by ph0010421 on How to transfer data from DINT to Union(16 Bools) which I need to use in Few FBs CODESYS Forge talk (Post)
In the Struct, change the 'BOOL' to 'BIT'
Last updated: 2023-12-14

Post by jeroen on Ramp function CODESYS Forge talk (Post)
Hi, will check the CodeSys function blocks. Didn't know those and usually the OSCAT lib is a bit more advanced. Kind regards!!
Last updated: 2024-01-10

Post by reinier-geers on ERROR no connection With RPI CODESYS Forge talk (Post)
Same problem, CHange SSH. Bit now the Install Button is deactivated ? Why ?
Last updated: 2024-01-11

Post by lyngaansns on CODESYS Installer CLI - commands syntax description CODESYS Forge talk (Post)
You can do APInstaller.CLI.exe --installAddOn -? for example for a little bit more information.
Last updated: 2024-03-04

Post by paro on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
CmpApp https://forge.codesys.com/prj/codesys-example/application-man/home/Home/
Last updated: 2024-06-17

Post by nano on Modbus TCP/IP slave communication errow CODESYS Forge talk (Post)
please tell us the exact error message from diagnostic. U can view it at devicetree in the node-element diagnostic from modbus-configuration. u also can activate the function auto-reconnect in master and increase a little bit the timeout and the repetition to male thw communication a little bit more robust
Last updated: 2024-02-04

Post by garrian on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
Thanks for your reply. I belive it is contiguous, I'm writing to adress 0 to 4. Or, do you mean something else? Well, something is happening. If I on the client set adress 1,2,3 to true, only 1 is set to true on the server side. On the client side, the data is array of word. But on the server side, the coils are array of bool. Holding register is array of word on server side. Can this be a problem? Attached screenshot of how it looks at the server side.
Last updated: 2 days ago

Post by felipemsgarcia on EtherCAT - Force Control Word CODESYS Forge talk (Post)
What worked for me: Use SMC_SetControllerMode and set the nControllerMode to SMC_nocontrol. With that, you can control the drive via Modes of Operation(16#6060) and Controlword(16#6040) directly. Hope that helps, Cheers!
Last updated: 2023-08-31

Post by ben1 on How to write multiple coils (Modbus FC15) CODESYS Forge talk (Post)
Yeah that is odd - sometimes you have to do what you have to do unfortunately. Have you tried sending consecutive bits in the word instead - ie. instead of [0].0. [1].0, [2].0 etc, send [0].0,[0].1, [0].2 etc. ?
Last updated: 2 days ago

Post by adaffern on Runtime on Raspberry pi5 stops after 15 seconds CODESYS Forge talk (Post)
Hi Guys, I'm new to CODESYS on the pi and I'm struggling to get it working. My issue is that the runtime keeps stopping after approximately 15 seconds. I have installed the runtime package 4.11.0.0 on the pi, trying on both a 64 bit and 32 bit OS. Looking at old forums it all references the 4B and the fact they used 32 bit Debian bullseye (the last version of raspberry pi os) however the pi 5 doesn't offer this version when I try select it in the imager. Has anyone managed to get running using the pi 5? Any help would be greatly appreciated. Thanks, Adam
Last updated: 2024-06-10

Post by sangeetnenwani on Test Driver Availability in CODESYS 64-bit and Test Manager 5.1.0.0 CODESYS Forge talk (Post)
I’m operating with CODESYS in a 64-bit configuration and the Test Manager at version 5.1.0.0, where I’m attempting to use project scripts from an earlier version. These scripts call for certain test drivers that are not present in my installation. It’s unclear whether the absence is due to the 64-bit system, an update in the test drivers, or if I need to enable or install additional elements. For instance, the loadproject(Codesys.Base) command is missing, but loadproject(testmanager.project) is available. The FileIO command for CODESYS isn’t accessible, yet the testmanager’s driver for it exists, as does the execuptscript command.
Last updated: 2024-08-06

Post by sangeetnenwani on Test Driver Availability in CODESYS 64-bit and Test Manager 5.1.0.0 CODESYS Forge talk (Post)
I’m operating with CODESYS in a 64-bit configuration and the Test Manager at version 5.1.0.0, where I’m attempting to use project scripts from an earlier version. These scripts call for certain test drivers that are not present in my installation. It’s unclear whether the absence is due to the 64-bit system, an update in the test drivers, or if I need to enable or install additional elements. For instance, the loadproject(Codesys.Base) command is missing, but loadproject(testmanager.project) is available. The FileIO command for CODESYS isn’t accessible, yet the testmanager’s driver for it exists, as does the execuptscript command.
Last updated: 2024-08-06

Post by alexgooi on Modbus writing on value change CODESYS Forge talk (Post)
The way I usally tackle this is by syncing only words (then you are able to use the FB above). If you then want to write a Boolean simply type it like this. Value[1].0 := Bool1; Value[1].1 := Bool2; Value[1].2 := Bool3; Uints have the same number of bits than a INT/WORD so these ones will work as well (they are only represented diffrently). A Real will work but you will loose some infomration in the conversion. If you want to keep the information you can convert 2 words to a float with a function (for example with the IEEE-754 standard) . In this way the syncing to the server is very simple and in the Codesys Program you decide what part of the word you want to use.
Last updated: 2024-04-03

Post by schorge on Modbus RTU Slave CODESYS Forge talk (Post)
Ich wĂĽrde gerne bestimmt Modbus RTU Slave Adressen auslesen, leider bekomme ich keine Werte vom Bus. Verbindung erfolgt ĂĽber einen Raspberry mit Modbus RS485 Adapter, welcher erfolgreich verbunden ist. Mit einem IOBroker kann ich die Daten erfolgreich auslesen. In der Modbus_COM_Port => Modbus_Serial_Device habe ich Input Register 4000 %QW und Startadressen auf Input Register 3000, als Variable ein Array[0..2999] of Word, kann aber keine Werte auslesen.
Last updated: 2023-12-06

Post by rajesh008 on i can't declear the address in GVL - codesys SP19 Patch5 CODESYS Forge talk (Post)
The “_AB AT %IW0:word; ” if i called the value then im getting this error. like below "the declartion of the variable with an address assignment cannot be used in a PRG or GVL with the attribute 'subsequent'" This is happening when the GVL is selected in Redundancy Configuration. if i un-select the address declaration is working fine
Last updated: 2024-05-13

Post by dkugler on Converting hex bytes to float CODESYS Forge talk (Post)
have a look at UNIONs. With a union you are able to write single bytes to the same adress area which belongs to a float variable at the same time. I like to do a lot of convertions belonging to interfaces and fieldbus in this way, f.eg. word / byte swapping etc.
Last updated: 2024-08-06

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
please use latest version 4.9.0.0 and it is mandatory to have a user pi on your device.
Last updated: 2023-09-11

Post by baldeep on Codesys Raspberry Runtime 4.10.0.0 and RSM Utility 3.5.19.0 CODESYS Forge talk (Post)
I had been using Codesys Raspberry 4.9.0.0 Runtime for a Project with CAA File 3.5.19.0. But now with Update 4.10.0.0 and Raspberry pi 64 Bit.....i cannot compile my code as RSM Utility 3.5.19.0 is not recognised. Any help? Regards
Last updated: 2023-11-20

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
raspberry pi is running ubuntu, so it has the codesys control for linux arm 64 bit, IDE is 3.5.19, both were installed last week from the latest versions online, im currently out of the PC but will upload some evidence ASAP
Last updated: 2023-12-18