Post by kuegerls on CSV Utility SL
CODESYS Forge
talk
(Post)
Hello, I want to read a CSV file using the CSV Utility SL library, but I encounter an 'invalid_handle' error during initialization. What could be the cause? For my test program see the screenshot. I have purchased a license, and it is also installed on my PLC. Thank you in advance. Best regards, Stefan.
Last updated: 2024-05-13
Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13
Post by matthew on Persistence Manager Backup
CODESYS Forge
talk
(Post)
Hi @eschwellinger yes I have been using xDoubleStorage It happened again and I checked and the files were still there with there contents, restarting codesys or rebooting would not even reload them. Doing a download and then starting the PLC loaded them and began working again. Some sort of mismatch error or something?
Last updated: 2024-05-14
Post by schnepper on How to delete main action from SFC Step
CODESYS Forge
talk
(Post)
I added a main action to an SFC step, and then tried to delete it. There is no delete option in the SFC menu nor in the right click menu of the step. I deleted the action from the device tree, but building results in and error saying the action is not defined. Is there a way to delete a main action?
Last updated: 2024-05-23
Post by totorovic on IO-LINK Package - new license model
CODESYS Forge
talk
(Post)
Hello, I'm using th IDE Combivis studio 6 (codesys based) and I get an error message when I use IO-link. "The license is missing or invalid. The API is running in demo mode." However the package Manager indicates that no licence is required. It used to work, it seems that the free package has become a paying one. Can Codeys confirm this? BR
Last updated: 2024-06-06
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by rikher on Error: Too few outputs exixts for the box 'MemCopy' (minimum is 1).
CODESYS Forge
talk
(Post)
I am using MemCopy Function for this example: https://www.youtube.com/watch?v=DeTCT5Vyn28&t=482s It is from library WagoSysPlainMem. I want to use this for an MQTT example. However, Codesys is complaining the block does not have outputs. How to fix this?
Last updated: 2024-06-19
Post by mait-tim on Errors after moving from SP18 to SP20/21
CODESYS Forge
talk
(Post)
Hello, Im running into a problem after moving from SP18 to SP20 or SP21. After the update I have an error with the TextFieldInmputHandler.VariableWritten which is implemented if de visualisation part of my software. The interface seems to have changed. I cannot find the new implementation. Does anyone know how to solve this issue.
Last updated: 2025-10-20
Post by mait-tim on Errors after moving from SP18 to SP20/21
CODESYS Forge
talk
(Post)
Hello, Im running into a problem after moving from SP18 to SP20 or SP21. After the update I have an error with the TextFieldInmputHandler.VariableWritten which is implemented if de visualisation part of my software. The interface seems to have changed. I cannot find the new implementation. Does anyone know how to solve this issue.
Last updated: 2025-10-20
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
Hello everyone, following corrupted data on the SD card of our Pi3B+ provided with a machine, we reinstalled a CODESYS image for Raspberry Pi, but we cannot find the 4.9.0.0 runtime that is compatible with the project. Currently, the machine is on 4.1.0.0, and we tried a more recent version 4.13.0.0, but there are error messages. Thanks in advance.
Last updated: 2025-10-24
Post by mg0815 on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks
CODESYS Forge
talk
(Post)
I use Codesys 3.5.21.1 too I have absolutelly the same fault. Do you know the solution? I get the same massages accept the last one (up to your's from 2025-08-03 04:38) The last messages do not appear. (your's later than 2025-08-03 04:40) Reagards Mg
Last updated: 2025-11-04
Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct)
CODESYS Forge
talk
(Post)
Hi Helpers I'm trying to work with stepper motor on Rasp 5 for the first time. So I'm pretty new.π₯here. I've used: https://forge.codesys.com/drv/sm3raspistepper/home/Home/ but I get the following error when I insert. I also get 6 errors when I "rebuilder" after installering "SM_Drive_RaspStepper_direct" from the tree. Hope there is help for me. Thanks in advance /Klaus
Last updated: 2025-11-04
Post by willebro on "Distributed clocks are not synchronized, Rea time problem on hardware" ?
CODESYS Forge
talk
(Post)
https://forge.codesys.com/forge/talk/Engineering/thread/632c29cb93/#8d94 The above comment is the best, but if you just want to see it work you can try disabling the distributed clock. It's not the right thing to do but it should resolve that error.
Last updated: 2025-12-16
Post by aniket-b on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
Thanks Georg for responding. I have followed the suggestion mentioned in the real time problem. However, it does not solve the problem. The weird part is, the robot stops at the same position randomly and it does not stop when I increase the speed of the motion.
Last updated: 2025-12-23
Post by blitz on SMC_ERROR SMC_CGR_INVALID_POSPERIOD
CODESYS Forge
talk
(Post)
Codesys - SMC_ERROR SMC_CGR_INVALID_POSPERIOD - Invalid modulo period less than or equal to zero or greater than half the bus bandwidth. Has anyone seen this error and actually understands what it means and how to get rid of it? I tried to work around it by reducing the number of increments on the drive but then the drive itself starts throwing errors.
Last updated: 2025-12-15
Post by yoeri on Python Scripted Save_Archive with noUI
CODESYS Forge
talk
(Post)
Is there any update on this? Running codesys 3.5.19.70 proj = projects.open(project_path, primary=True, update_flags=flags) This gives an error only when using --noUI exception System.NullReferenceException: Traceback (most recent call last): File "C:\Project\ci\build.py", line 14, in <module> SystemError: Object reference not set to an instance of an object. Exit code: 1</module>
Last updated: 2026-01-30
Post by ofey on Codesys Soft PLC OPC UA server
CODESYS Forge
talk
(Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Hello I'm trying to use DirOpen to access a directory where then I can read/list the files inside. But I can't list any files because DirOpen.xError is always true. In eError the message is this: " ERROR_UNKNOWN Local library error ID (0: no error; 5101: time out)**** " I have in the file explorer the path 'C:\CodesysTest\Aluminium' and to make sure I also created in the plc a folder to 'prj/Recipes/Aluminium'. I tried using the different paths, but in both it happens the same thing.Inside the folder Aluminium there is two csv files, that I want to list. I added in the library manager CAA Files and CAA Types. I am using the example of https://content.helpme-codesys.com/en/libs/CAA%20File/Current/Examples.html#directory but not matter what I do, I can't get the list the names of the files. What am I missing?
Last updated: 2024-07-31
Post by sean-barton on Ambiguous namespace in library dependencies
CODESYS Forge
talk
(Post)
I am trying to install the MQTT Client SL in an existing project I have been working on for years. After adding the library to the project, and without adding any other code, upon building I get a C0180: Ambiguous namespace 'MBM' error between the memory block manager (MBM) in the NetBaseSrv dependency of the MQTT Client SL library and the memory block manager (MBM) in the CAA CanL2 dependency of the 3S CANopen stack library. I have tried: * setting "Only allow qualified access to all identifiers." in the properties for both the parent libraries. * deleting the 3S CANopen stack library. Upon (re)building the error simply points to another conflicting library - there are many. * deleting the Library Manager and rebuilding it. * adding the memory block manager library (used in the NetBaseSrv) manually and changing its namespace to MBM3S. None of the above allow me to access the MQTT library through its namespace (MQTT). Adding the memory block manager manually removes the C0180 error, but the MQTT library is not accessible - i.e. mqttClient : MQTT.MQTTClient; highlights the mqttClient as "Identifier 'MQTT.MQTTClient' not defined". Is there anything else I can try?
Last updated: 2025-01-09
Post by pernockham on Persistence Manager: Config File not found?
CODESYS Forge
talk
(Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20
Post by imdatatas on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR]
CODESYS Forge
talk
(Post)
Dear @gseidel, Thank you for your reply. The exact version of Codesys and its compiler was 3.5.21.20. The compiler version was fixed and could not be changed in project settings. Since I couldn't continue due to this compilation error, I temporarily overcame this issue as follows. -- I completely uninstalled Codesys 3.5.21.20 and completely deleted the Codesys folder in the C:\ProgramData folder. -- I restarted my computer and installed Codesys 3.5.19.70. -- I updated the Codesys Installer and all its add-ons to the latest versions. -- The project that was giving me the compilation error I mentioned before is now open with Codesys 3.5.19.70, compiled it, and successfully downloaded it on the device. -- I haven't encountered the same problem anymore. I think this issue is related to SP21 and its compiler. Frankly, I'd expect a project created with an older version to compile without errors after opening it with the latest Codesys version and updating all libraries. Regards, imdatatas
Last updated: 2025-09-26
Post by mavitia on Application based license problem - Modbus TCP
CODESYS Forge
talk
(Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.