Post by eschwellinger on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old CODESYS Forge talk (Post)
yes, but use ARM64SL package pi package does not have codemeter lite embedded
Last updated: 2024-09-18

Post by thn-power on How to change OPC NodeId IdentifierType CODESYS Forge talk (Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20

Post by danielbeers on Automation Server + Pi Gateway + PLC w/ CAN CODESYS Forge talk (Post)
Hello, I have a project using some EPEC PLC's. Some of them are programmable using Ethernet and some use CAN. We currently have a Raspberry Pi that is acting as a gateway to the Codesys Automation Server and is successfully working for the PLC's communicating over ethernet. I am trying to achieve a similar result for the PLC's that have only CAN access. I have PEAKCan drivers on the Pi, and can successfully send/receive messages. But the Gateway does not recognise the PLC when scanned from the Automation server online. Is there a library or service that exists to translate the CAN messaging, to the Edge Gateway, and be able to achieve remote access with the Automation Server? Or is this not possible without creating something custom? Cheers, Daniel
Last updated: 2024-09-22

Post by pierre on difference between stub file and source file in scriptengine CODESYS Forge talk (Post)
same situation for DeviceID. In the stubfile this is Deviceid
Last updated: 2024-09-23

Post by ph0010421 on How to manage variable types larger than 64 bits - Ethernet/IP CODESYS Forge talk (Post)
My guess is that's a STRING, not an INT type. And it's 128 bytes, not bits
Last updated: 2024-09-23

Post by zatalian on Visualization Toolbox in German CODESYS Forge talk (Post)
Is there a solution for this problem? Same here where the OS language was french during the installation of codesys (SP20 Patch2)
Last updated: 2024-09-26

Post by andrebrandt on how to extract the name of an FB to a variable CODESYS Forge talk (Post)
Hi mr. Do you have the script? Cause the link is down.
Last updated: 2024-09-27

Post by andrebrandt on how to extract the name of an FB to a variable CODESYS Forge talk (Post)
Hi mr. Do you have the script? Cause the link is down.
Last updated: 2024-09-27

Post by andrebrandt on how to extract the name of an FB to a variable CODESYS Forge talk (Post)
Hi mr. Do you have the script? Cause the link is down.
Last updated: 2024-09-27

Post by timvh on Visuutils FbOpenDialog(Extended) not open Dialog from POUs CODESYS Forge talk (Post)
I had a similar situation recently where this didn't work, but read to the end to see the solution. The reason is that CODESYS only downloads visualisations (dialogs) if they are part of the project or linked to the project. In your case the dialog is not loaded onto the controller. But the solution is pretty simple: Double click on the Visualization Manager in your application. Select the Tab "Visualizations". Here you can see that your dialog is not "checked". Do this manually and load your project on the controller. Then your code should be able to open the dialog, because now it exists on the controller.
Last updated: 2024-09-28

Post by jacobwago on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
Hello, I have experienced the same issue as described above but for the Modbus Serial configurator. Looking for a solution. In v3.5 SP19 Patch 7 the Modbus Serial Master Slave configurator has a "virtual" limit of 10 channels. In v3.5 SP18 Patch 5 this virtual limit does not exist. I can successfully copy back and forth from 18 to 19 with out any build error. However, this is not a good solution for our customers. What is even more confusing is that the IoDrvModbus library is the same version (4.3.0.0) for both SP18 and SP19. Please help in providing a fix to the virtual channel limit of 10 in SP19. Thanks,
Last updated: 2024-09-29

Post by dangjoris on raspistepper error after install CODESYS Forge talk (Post)
Hi, I am in the same situation. Is this still your best method? To go back to sp17? best regards
Last updated: 2024-09-30

Post by lsislsis on RPI Serial port connects with no errors but not data being transmitted or received CODESYS Forge talk (Post)
Is there any solution because we have the same problem with other hardware?
Last updated: 2024-09-30

Post by rmaas on Change remote targetvisu updaterate? CODESYS Forge talk (Post)
Hi, Is it possible to change the updaterate for a remote targetvisu? BR, Rinie
Last updated: 2024-10-02

Post by lsislsis on Alarms Placeholder CODESYS Forge talk (Post)
Hello. Is there any way to set placeholder for Alarms Storage at Usb Flash Disk? Regards
Last updated: 2024-10-03

Post by robinluckey on IDE window handling bugs, windows diasppear, multi monitor setups CODESYS Forge talk (Post)
Codesys Windows (Main window as well as pop-ups) often appear outside of the viewable are in Windows when using multiple Monitors. This is exacerbated (happens more very often), when working on a notebook with different Monitor setups at different locations (which kind of is standard nowadays). The windows (not even the main Window) can not be recovered using standard short cuts like WIN + Arrow keys, alt + tab etc. The only way we found to recover the windows is by changing the Monitor positions in thew Windows Display Settings and than changing them back EVERY TIME a pop us is displayed. This makes using Codesys close to unbearable. All my colleagues face the same problem and do not have this problem with any other IDE. Please help.
Last updated: 2024-10-11

Post by eschwellinger on Persistent variables are not read after initialization CODESYS Forge talk (Post)
no need to activate application composer. It is part of the licensefree part.
Last updated: 2024-10-11

Post by eschwellinger on EThercat Dynamic configuration CODESYS Forge talk (Post)
start point for doing this is for sure this example here: https://content.helpme-codesys.com/en/libs/EtherCATStack/Current/EtherCATStack/pou-ETCMasterStack/DynamicConfig/fld-DynamicConfig.html
Last updated: 2024-10-16

Post by pietrobalint on Persistent variables are not read after initialization CODESYS Forge talk (Post)
What do you mean it is part of the licensefree part? I attached my error message.
Last updated: 2024-10-20

Post by bjarne-pagaard on OPC UA Server Status on Win RTE CODESYS Forge talk (Post)
The Control RTE is 3.5.18.20, using the symbol configuration for exposure of variables.
Last updated: 2024-10-22

Post by timvh on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
RS485 doesn't seem very logical to use in VPLC's in my opinion. I also don't know if this is supported.... But for TCP/IP, I think you still need to configure the Nic settings. See the attached png. In my case enp6s0. When changing this setting, restart the VPLC. What is really nice, is that you don't have to configure the IP address setting in Linux. By setting the Nic to a certain IP address in the CODESYS instance configuration, this is automatically done for you. I only tested this with EtherCAT, but I guess this works the same for Modbus TCP/IP.
Last updated: 2024-10-23

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
I made a mistake it is not end0 but eth0. But I have the same error.
Last updated: 2024-10-23

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
Your right, much easier with Linux control SL ARM. Everything is working.
Last updated: 2024-10-24

Post by eschwellinger on How to use PLC_Open FBs with PROFINET servodrive (PROFIdrive layer) CODESYS Forge talk (Post)
At the moment, no chance to do this - this is not supported
Last updated: 2024-10-30

Post by eschwellinger on TargetVisu controls are incorrectly positioned CODESYS Forge talk (Post)
yes this is a bug, please disable the overlay functionality in the Visualisation Manager in your project
Last updated: 2024-11-03