Search talk: -128到127是什么数据类型

 
<< < 1 .. 58 59 60 61 62 .. 887 > >> (Page 60 of 887)

Post by thommy54 on CODESYSControl_User cfg richtig konfigurieren CODESYS Forge talk (Post)
Hallo, nach Erwerb eines neueren Raspberry pi 4 (V1.5) musste ich zwangsläufig von Codesys 3.5.16 hochwechseln - ich habe auf 3.5.20.1 geupdated. Da schlugen mir plötzlich ne Menge Einschränkungen entgegen, deren Behebung einige Zeit dauerte. Eine davon ist, das ein SysFile.SysFileOpen nicht mehr funktioniert. Ich habe das Problem mit Einträgen in der /etc/CODESYSControl.cfg behoben: [SysFile] FilePath.1=/etc/, 3S.dat IecFilePath.1=/proc/, cpuinfo IecFilePath.2=/proc/, iomem PlaceholderFilePath.1=/sys/devices/w1_bus_master1, $OneWire$ PlcLogicPrefix=1 ; ; ---------------------- ; selbst eingefügt PlaceholderFilePath.2=/home/root, $my_home_root$ PlaceholderFilePath.3=/etc/init.d, $my_conf$ PlaceholderFilePath.4=/var/lib/mpd, $my_music$ PlaceholderFilePath.5=/root/Rasp_SPS_Filesystem, $my_Rasp$ Ob die Einträge sich etwas überlappen, kann mir gern jemand sagen, das ist aber nicht das Problem. Ich habe bei den vielen Versuchen, das Teil zum Laufen zu bringen, bemerkt, daß die Einträge auch ganz schnell mal verschwinden. Das ist ja auch so beschrieben, wenn die nächste Version kommt, sind meine Einträge weg. Da ich ähnliche Probleme mit dem Funktionieren von "SysProcessExecuteCommand2()" hatte, die ich ebenfalls mit Einträgen in die /etc/CODESYSControl.cfg hätte beheben können, habe ich gelesen, das man "private" Einträge lieber in die Datei /etc/CODESYSControl_User.cfg machen soll. Gesagt getan und "SysProcessExecuteCommand2()" lief: [SysProcess] Command=AllowAll Command.0=shutdown Aber auch irgendwo stand, das so ein Beteichner wie [SysFile] oder [SysProcess] nur einmal in den beiden Files /etc/CODESYSControl.cfg oder(!) /etc/CODESYSControl_User.cfg vorkommen darf. Das ist nun die eigentliche Frage! Ist das so ? Bei [SysProcess] ist das kein Problem, das gibt es in /etc/CODESYSControl.cfg nicht. Aber bei [SysFile] sieht das anders aus. Da sind 5 Zeilen schon in /etc/CODESYSControl.cfg drin. Würde ich diese in die User-Datei rüberschieben, könnte beim nächsten Update was fehlen oder, oder... Lasse ich es so wie es ist, sind meine Einträge beim Update weg - das sollte ja verhindert werden. Kann da jemand genaue Auskunft geben ?? Vielen Dank Thomas
Last updated: 2024-06-28

Read tag values using external program CODESYS Forge talk (Thread)
Read tag values using external program
Last updated: 2024-06-28

Post by tcarlbom on Read tag values using external program CODESYS Forge talk (Post)
This is my first time posting in this forum and I am new to codesys. I am a fullstack developer and I am trying to figure out how the following. What would be the best approach to create a own/custom tag browser? Either directly in codesys ide or using a separate custom program (perhaps a winforms application). 1.a. Shall I parse the .project xml file to get a list of all tags in the project? 1b. Shall I use python scripting in codesys ide to get a list of tags? Once one have selected some tags. These tags shall be exposed to a python program which will be acting as a edge computer. It’s fine to be able to import a file. 2a. I found a library called codesys plchandler which (as I understand) acts a rest api server. Is this correct? If so, can I query the api from a custom python script, ie can query what tags exist in project and or read tag values? My research so far. From earlier projects I know that using opc ua would be perfect for this but from my opinion it’s bloating the plc since it’s resource intensive. So opc ua is not an option. Codesys automation server is neat. But I don’t want to rely on some cloud services and subscription based pricing. There seem to be several interesting codesys libraries like mqtt, tcp server and NVL sender which would help me expose plc tags. But all have a common problem. One have to manually write what tags which will be used in these function blocks. I want a similar experience like “selecting” tags in the opc ua or the codesys tracing, ie a tag browser.
Last updated: 2024-06-28

License issue with visu tags CODESYS Forge talk (Thread)
License issue with visu tags
Last updated: 2024-06-28

Post by jeffg on License issue with visu tags CODESYS Forge talk (Post)
I seem to be having a problem with the license on ver 3.5.19 patch 5 The runtime keeps going into demo mode but it wont tell me the reason I looked at the license software metrics and the visu doesn't appear to be working I attached screen shots of the metrics screen and the license dongle that is plugged in to the windows PC Anyone have any ideas on how to fix this
Last updated: 2024-06-28

Post by exkrim19 on Unable to connect to this device CODESYS Forge talk (Post)
What worked for me with this error was to go to Tools -> Update Raspberry Pi, select Install, and from the popup screen, there are options to change your installation (I changed it to single core, instead of multicore), and I was then able to connect to my Rpi 4.
Last updated: 2024-06-28

Unable to connect to this device CODESYS Forge talk (Thread)
Unable to connect to this device
Last updated: 2024-06-28

Post by nano on WAGO device in Codesys V3 CODESYS Forge talk (Post)
wago uses, as long nobody has changed it byself: root/wago or on most plattforms admin/wago (same like prop. webserver) just google it
Last updated: 2024-06-30

Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Thread)
Codesys Communication Manger - Required information model version exists in the model repository but is not found
Last updated: 2024-06-28

WAGO device in Codesys V3 CODESYS Forge talk (Thread)
WAGO device in Codesys V3
Last updated: 2024-06-30

Import XML CODESYS Forge talk (Thread)
Import XML
Last updated: 2024-06-28

Post by nikgind on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi, yes i did solve it. You have to change the namespace 0 model in the UaModeler. Open the modeler --> Settings --> Edit Settings --> scroll down to the last option "External Model Support" --> Check "Allow replacing built-in..." Now create a new project in the UaModeler. If you have to choose your base models, you can see the option "Find another Opc.Ua.NodeSet2". I have attached the .xml i am using.
Last updated: 2024-06-28

Post by codesysdave on Import XML CODESYS Forge talk (Post)
Great info from 2011... thanks!
Last updated: 2024-06-28

TCP Client CODESYS Forge talk (Thread)
TCP Client
Last updated: 2024-07-01

Post by abinvest579 on TCP Client CODESYS Forge talk (Post)
Hi All, I am using codesys based plc to read and control magna power DC supply over LXI protocol using SCPI command. To connect device required socket programming for that i am using Net base service library function block TCP_Client to establish connection over TCP/IP , TCP_Write to write SCPI commands and TCP_Read to read data from Magna power DC supply. I have attached screenshot for logic developed. I am able to connect and write commands to device but i not receiving any information from device. For writing Commands i also tried various end of line character like \n,<nl>, A, D, 10, 13, 0x0A, 0x0D but not received any status from device. For testing purpose i am using simple command '*IDN?' to read data. Also if tried to check on hercules software what data actually plc read, first it read correct data after that is read wrong data as see in screen shot. 'Hello World' was correct read and after that Codesys in replaced with 'Codesysorld' that is not correct way. Same issue also appeared for send data. Any one have face same issue how i can read data directly from device correctly and send data please suggest solution on this.</nl>
Last updated: 2024-07-01

connect IDE to plc that uses modem ppp CODESYS Forge talk (Thread)
connect IDE to plc that uses modem ppp
Last updated: 2024-07-01

Post by hwopereis on How to use Application Trigger in Modbus TCP Server CODESYS Forge talk (Post)
Hi, I'm currently reading and writing several registers with a Modbus TCP server as a subdevice of a Modbus TCP Client. If I read and write cyclically, there are no issues. The problem is this: I see there is also the option to write by "Application", which I would like to use. However, I don't know With the Modbus RTU client, I see there is a trigger variable, xTrigger, to trigger the writing tasks. However, I can't find any such trigger for the Modbus TCP Client. Does anybody know how to implement the trigger behavior for the Modbus TCP client? In particular, I struggle to find the exact "trigger" variable. I'm running Modbus Client version 4.4.0.0 Thanks in advance!
Last updated: 2024-07-01

Post by wbj0t on What the right way to update TCP/COM slave device holding registers CODESYS Forge talk (Post)
Hi all :) I have an plc. This plc has option to be as slave device. There are TCP -> Serial Slave Device and COM -> Serial Slave Device. There are 4096 ModBus holding registers with mark "internal modify" for the both devices above. So, COM Slave has 4096 registers and TCP Slave has 4096 registers. And, finally, I have an ARRAY[0..4095] OF WORD. This array glued with COM Slave and TCP slave. Yes, I need plc's opportunity to be communication both TCP and COM ways for the same registers. For example, the next task structure: * TASK_0: 1. pou_READ_Registers 2. pou_0 3. pou_1 4. ... 5. pou_N 6. pou_WRITE_Registers At the first pou I read registers for the other pous, after job we have sort of state of the plc. At the last pou (6) we write modified registers. It is a good scenario: some one wrote registers for the job, after job we save these (modified) registers. But, what if registers wrote between 1 and 6 pou by operator, for example, at the 3 pou -> the last pou 'pou_WRITE' will rewrite this request from operator. What the right way to work with this logic? Thanks you.
Last updated: 2024-07-01

Post by andrax on CODESYSControl_User cfg richtig konfigurieren CODESYS Forge talk (Post)
Das wurde das schon vor längerer Zeit geändert. Du kannst aus Sicherheitsgründen nicht auf Systemverzeichnisse zugreifen. Auch wenn du die .cfg anpasst, werden diese beim nächsten update wieder überschrieben, so wie du schon sagtest. Am besten nutzt du nur dein Homeverzeichnis, das bleibt weiterhin frei zugänglich.
Last updated: 2024-07-01

Post by wbj0t on connect IDE to plc that uses modem ppp CODESYS Forge talk (Post)
Thanks for reply. I did all understand, thanks you :)
Last updated: 2024-07-01

What the right way to update TCP/COM slave device holding registers CODESYS Forge talk (Thread)
What the right way to update TCP/COM slave device holding registers
Last updated: 2024-07-01

How to use Application Trigger in Modbus TCP Server CODESYS Forge talk (Thread)
How to use Application Trigger in Modbus TCP Server
Last updated: 2024-07-01

Prüfen ob Datei existiert wenn nicht neu erstellen CODESYS Forge talk (Thread)
Prüfen ob Datei existiert wenn nicht neu erstellen
Last updated: 2024-07-01

Post by hwopereis on How to use Application Trigger in Modbus TCP Server CODESYS Forge talk (Post)
I'm now circumventing the problem by creating a separate TCP client for all Write actions. Upon registering a changed variable, I enable this client, until the change is processed.
Last updated: 2024-07-01

Post by shabroz-gill on Data Sources Manager causing exception due to float or double type in OPC server CODESYS Forge talk (Post)
Was this ever resolved? I see the same issue with the version 3.5.19.5
Last updated: 2024-07-01

<< < 1 .. 58 59 60 61 62 .. 887 > >> (Page 60 of 887)

Showing results of 22165

Sort by relevance or date