Post by lbartik on MPC predictive control
CODESYS Forge
talk
(Post)
Would this work? https://www.mathworks.com/hardware-support/codesys.html I'm also interested in real-world MPC and have no idea where to start. There is an exciting Python library that is also beyond my grasp: https://www.do-mpc.com/en/latest/index.html Step 1, get PhD(s). Step 2, get job in aerospace/robotics. Step 3, return 15 years later to share this knowledge?
Last updated: 2024-10-19
Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3
CODESYS Forge
talk
(Post)
The problem is that newer PeakCAN cards are with CAN FD support and SJA1000 compatibility isnt mentioned anymore on website. anyway, is it possibile to add a seperate entry for it in: [CmpSJACanDrv] ? Edwin, can you give us a hint how to format it?
Last updated: 2024-12-16
Post by timvh on PLCOpenXML Export/Import with Visualisation
CODESYS Forge
talk
(Post)
A Task is a standard IEC 61131-3 object, so logically that you can export the VISU_TASK. A visualization is no standard IEC 61131-3 object, so not compatible with other IEC tools. Just use the standard export / import functionality. These files are not IEC compatible and can only be used in CODESYS. But these do support visu objects.
Last updated: 2025-01-09
Post by timvh on Library ENUM text representation in visualization
CODESYS Forge
talk
(Post)
Probably the enum from the library doesn't have text support. In that case you need to add your own TextList to the application. In the rectangle you should use the property "dynamic text" to link this object to the textlist which you have created yourself and then link the text index to your enum variable.
Last updated: 2025-01-09
Post by navan on License Reset Request ā CODESYS Control Win V3 Standard L
CODESYS Forge
talk
(Post)
Dear CODESYS Support Team, My IPC hardware failed and was replaced. The CODESYS Control Win V3 Standard L license now shows āActivation Invalidā in CodeMeter Control Center. Please reset or reissue the license to my new IPC. Details: Product: CODESYS Control Win V3 Standard L 32 bit Version: 3.5.20.10 Ticket : Xxxx-xxxx-xxxx-KJE4 New Container ID: (130-......837) Thank you,
Last updated: 2025-10-23
Post by s1mon on Two OneWireMaster on one Raspberry PI 5
CODESYS Forge
talk
(Post)
Took me a while to work on this again. I testes today with a fresh setup and it works now. My OneWireCycle tasks runs for around 10seconds. I guess my mistake was that I put the cycle task for the OneWire Task to a too small number. Thx for the support!
Last updated: 2025-11-22
Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i“m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i“m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i“m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10
Post by ofey on Testing of Codesys program
CODESYS Forge
talk
(Post)
Hi! I thought to hear what you guys think is the best way to test the program in my scenario. I have some PLC programs that have been made and deployed on different PLC's. The program has added the specific devices and IO that is applicable. I have made a test environment for everything outside of the PLC, ie. the same SCADA system that is talking to the PLC, and a program running locally is simulating the plant (level regulation of different tanks). Pr. now I have had to manually change the variables that are reading/writing values from the IO so they read/write via OPC instead. I also have to change the device tree from the specific PLC rack, to the soft PLC. So I kind of end up with two different programs that I have to maintain. I was just wondering if you believe there is an easier way to do this. So I can have the exactly same program and kind of switch between the soft mode, and the "real" mode.
Last updated: 2023-12-07
Post by ellocco on XOR with four Inputs with OR-, NON- and AND-Operators
CODESYS Forge
talk
(Post)
My topic is more of academic nature, I would like to implement an XOR-operation with four inputs on my own (without the predefined XOR-operator) in a function block diagram (FBD). I have two proposals. One works fine and the other one is just an idea, but I do not know, if it is possible to code it in CODESYS V3.5 SP18 in form of a FBD. Here the one that works: And here an idea, which I have not managed to code it as an FBD: Any ideas? Is the 2nd diagram a correct interpretation of the coding task? And is there a way to implement it in form of an FBD in CODESYS V3.5 SP18? Followup (08-Nov-2024): Also in the current version of CODESYS (V3.5SP20Patch3) I have not managed to connect the existing blocks. In the alternative SPS-IDE PLCnext Engineer it is possible.
Last updated: 2024-11-08
Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation
CODESYS Forge
talk
(Post)
Good morning, Iāve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object Iām running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I donāt understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesnāt report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case Iām working on an isolated single core. Iāve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. Iād like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11
Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server
CODESYS Forge
talk
(Post)
Ok, for the sake of completeness in case anyone else has this problem. I can tell you that what finally worked for me was to change the line: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA", 5), structAData ); to: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA|defaultbinary", 5), structAData ); I'm sure there are many other problems that could cause this very generic error, but this was my problem.
Last updated: 2024-12-30
Post by ameba on PersistentVars and Webvisu Element
CODESYS Forge
talk
(Post)
hello everyone I would like to try to better understand how persistent variables work. I created some boolean variables in the PersistentVars section initialized to the value TRUE. I have tied these boolean variables to toggle switches placed inside the HMI interface pages. Once the PLC program is started, the lever selectors, if operated, change their state, at least at a graphical level, but the persistent variables do not undergo any variation. Initially the above variables were declared as simple global variables, in this case the operation with the levers was correct; I then tried to transform them into persistent ones with the aim of using them as "settings saver" Thank you for support Bye
Last updated: 2025-04-03
Post by davidbo on All the things needed for anonymous login to OPC UA
CODESYS Forge
talk
(Post)
I thought I knew what I am doing, but something is missing what? From Device-Communication Settings select from drop down menu "Device" Select entry "Change Runtime Security Policy" Check the "Allow anonymous login" Select "Symbol Configuration" in your application In settings check "Support for OPC UA features" Check some of the values you want in your set Press the build button in the "Symbol Configuration" Press the button "Configure Symbol Rights" Make sure that Anonymous_OPCUAServer has access right to your "default set" From Device-Communication Settings select "Access Rights" in RemoteConnections-OPCUAServer Anonymous_OPCUAServer should be given modify and view rights I suppose. I can connect with UaExpert but I cannot see my Application or browse my values. What is missing?
Last updated: 2025-09-10
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Thank you for your quick response, I have updated to the 4.17.0 (Virtual control and the license server). Now I am able to see the softcontainer from the Codesys IDE. But when I want to activate the license I get the following message: Licensing info not available. The device does not support this service (See picture). I then tried to active it via the WBM service like you suggested. But when I try this is get an error (see picture for error). I also tried to put RTS- in front of the serial number, but when I try this I get an error that the serial number is not correct. I think I'm getting closer, but I'm not there yet.
Last updated: 2025-10-01
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
If support for a containerized CODESYS runtime with a license isn't feasible, then I've considered an alternative approach: I've purchased and activated a "CODESYS Control Basic S" license on my Windows notebook, where I already have the Codemeter Control Center installed. Upon activation, I can see the CODESYS license as active on my notebook. Subsequently, I followed the instructions provided in this link (https://faq.codesys.com/display/CDSFAQ/How+to%3A+Setup+a+Wibu+Network+Server+Access+for+Licenses) to configure the Wibu runtime in the CODESYS container to access my external license server hosted on my notebook by editing the CODESYSControl_User.cfg file accordingly. However, it's worth noting that I'm still receiving a response from the Licensing Manager indicating that the runtime is persistently searching for a dongle instead of recognizing the soft container. So how can I get my runtime licensed now? Any ideas?
Last updated: 2024-03-20
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I recognized that I have to start the two services "/etc/init.d/codemeter" and "/etc/init.d/codemeter-webadmin" in the docker container as well. If I do so, then the command "cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. So this time there is no indication any more that "Codemeter is not running". But still we are getting the error when using the license manager in CODESYS development system.
Last updated: 2024-03-21
Post by fugtwad on Automation Builder V2.5 EtherCAT CM579 Master Scan for devices - >No gateway selected
CODESYS Forge
talk
(Post)
ABB Automation Builder v2.5.0.22 Premium CodeSys 2.3.9.62 Running on Win 10 VM x64 Goal: I have an EtherCAT topology issue which normally a "Scan for devices.." on the EtherCAT master would shed some light on. Issue: Upon trying such I get a "No gateway selected" error. Question: How might I point the the "scanner" at a gateway? What is working: Gateway is running in system tray. I can go online to PLC. A scan from the "Diagnostics live" tab of the EtherCAT master gives slave status. What I have tried: Restarting gateway in system tray. Exiting system tray gateway and reloading it. Turning off firewall. Contacting ABB support multiple times. Any help appreciated.
Last updated: 2024-05-20
Post by timvh on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
The RTE will take the RTE license. The HMI will take the HMI license. For the Application Based Licenses, the Runtime will take the smallest which is required. So if you have an application running EtherCAT and no visualization, only the Control with support for EtherCAT is used. If you have another runtime which requires the visualization, it will take the smallest Control license which is required and available + the smallest visualization license which is required.
Last updated: 2024-10-01
Post by alimans on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hi Manuknecht, Did you manage to solve the problem? Iām facing the same issue with Windows RTE SoftMotion ā it works fine as long as nothing else is open in Windows, but as soon as I start another application, the EtherCAT DC time and max jitter values spike, and then all axes stop. Iāve already sent a support request to CODESYS, but havenāt received a response yet.
Last updated: 2025-10-23
Post by murdemon on CNC Jumps G20 - SMC_NCInterpreter and long time to process
CODESYS Forge
talk
(Post)
Best way.. in CNC program before G20 jump, set G75. And for fbCheckVel execute if fbInterpreter.bWorking AND fbInterpreter.bLastObjectWasAdministrative; and same for Interpolator. " ..... dumm := fbInterpreter.bWorking AND fbInterpreter.bLastObjectWasAdministrative; //Check velociteses. fbCheckVel(bExecute := (fbInterpreter.bDone or) dumm, bAbort := gCNC.bCycleStop, poqDataIn := fbInterpreter.poqDataOut); "
Last updated: 2024-08-03
Post by ofey on Device parameter - āModbusTCP Configurationā
CODESYS Forge
talk
(Post)
Hi! Do anybody know how I can add and enable the parameter 'Default Modbus TCP slave' on a device? I am currently writing a program where the PLC shall be set up as a Modbus TCP client, but I dont know how to add parameters to devices in codesys. I'm pretty new to the codesys environment. The picture in the attachment is on a similar PLC project where I have not written the code. my goal is to add this parameter in another project.
Last updated: 2023-10-04
Post by josul on Web Client HTTPS Communication Issue
CODESYS Forge
talk
(Post)
Thank you for the suggestion. There is a certificate created in the quarantine directory relating to the URL used for the webclient FB. This certificate should have been valid as it was created only the week before this problem was encountered. I investigated a separate location using the same https URL and it has 2 certificates in the same quarantine directory, 1 is created almost 200 days ago, the other over 100 days ago. There have been no similar problems encountered with these certs or https at all.
Last updated: 2025-06-09
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
I put in a support ticket request for this issue since I need this application to be running reliably for my customer's application. Hope to hear back from support soon to troubleshoot this process.
Last updated: 2023-10-09
Post by eschwellinger on Using the Wago 750-658 CAN Gateway
CODESYS Forge
talk
(Post)
I would ask the Wago Support - they have a CODESYS V3 runtime (not eCOCKPIT) which probably support this? At least worth to ask them.
Last updated: 2024-07-23
Post by eschwellinger on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Seems that the Wago Target does not support the licensing. Either use PFC200 SL from CODESYS Store or ask the Wago support for help.
Last updated: 2024-06-10
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.