Post by yongchaow on Can't connect to Device Raspberry Pi 4 from CODESYS IDE V3.5 SP19
CODESYS Forge
talk
(Post)
Hi, eschwellinger, I have the same problem, but I can not resolve the problem following this forum. There are my situation: pi@RevPiXXXX:~ $ uname -a Linux RevPiXXXX 5.10.120-rt70-v7l #1 SMP PREEMPT_RT Thu, 28 Jul 2022 10:36:48 +0200 armv7l GNU/Linux After "top": It looks like runtime is not running. One more piece of information to refer to, when I reboot the device it is possible to scan the device. Looking forward your reply.
Last updated: 2024-04-25
Post by arundara on OPC UA Server Stops after 5 consecutive disconnections of ethernet port
CODESYS Forge
talk
(Post)
Hello Every one, During testing of OPC UA communication between UA Expert software and the CODESYS SoftPLC on a Linux environment, an observation was made. When the Ethernet cable was disconnected and reconnected with 2-minute intervals, on the 5th attempt, the OPC UA connection failed to establish in UA Expert software. At this juncture, restarting the CODESYS SoftPLC enabled the reestablishment of OPC UA communication. The same result was obtained when testing on a Raspberry Pi SoftPLC. What is the reason behind this phenomenon? and whether there are settings to stop this behavior? Please help. Thanks & Regards.
Last updated: 2024-02-13
Post by oi18ct on ARM SL Development Board Recommendation
CODESYS Forge
talk
(Post)
Hello codesys forum, My company is looking at developing a solution with Codesys ARM SL. The requirements will not tax the capabilities of Codesys. I would like to buy an AMR 7 or 8 Dev Board for experimenting. I am looking for a recommendation as I have minimal experience with Linux. Any input from the forum would be most appreciated as the hardware requirements as provided by Codesys for ARM SL seem pretty minimal (basically a arm7 or 8 with Debian is all). Our needs are small in scale- something like 8 digital inputs, 6 digital outputs, 2 analog inputs and 1 analog output. A small gui will be published via web visualization for external display (no local display). Communications with ModbusTCP and uart/RS485. It may be necessary to access i2c and make c or python calls to some existing code that is pretty small. Something like the EMCraft STM32MP1 SOM Starter Kit or Octavo Systems OSD32MP1-RED development board? Ideally something that has a path to a SoM for production. Kontron appears to have some interesting options too. Just having a hard time deciding where to start. Thanks in advance... LC
Last updated: 2023-11-11
Post by dominggus on when going online, stuck on "Syncing file "visuelemsdatetime.tl_datetime.txt"
CODESYS Forge
talk
(Post)
Hi, We are currently using a Raspberry Pi 4 CM4 module in a EdgeBox RPI 200 - Industrial Edge Controller running the latest CODESYS Runtime Package 4.11.0.0. On the PC (actually an Intel Macbook Pro running Windows 10 in Parallels) we run CODESYS V3.5.19.50. Yesterday end of day when I was about to logoff and head home, I wanted to send the latest build to the Raspberry I clicked the Login button to compile a new version and then sync the application and all the files, it get's stuck on the last file to sync (see attached screenshot). This takes eternally, although sometimes, when I use my SFTP client (Cyberduck) and go into the raspberry and refresh the directory /var/opt/codesys/PlcLogic/visu/, or when I open the actual file visuelemsdatetime.tl_datetime.txt, it gets un-stuck (forcing a refresh, which might fix the syncing issue) and CODESYS continues and I can click the Start button to start the application. But this SFTP force refresh trick does not always help either... What could be the issue here? network connectivity? Can someone please help me out?
Last updated: 2024-03-02
Post by hermsen on Control Runtime Toolkit
CODESYS Forge
talk
(Post)
Hi, there is a plethora of hardware available for it to be succesful on. In theory every ARM32/64 or x86/64 device is a potential target. Next to this there are embedded device platforms for which specific toolchains are available. A good starting for manufactureres of CODESYS capable devices is available here: https://www.codesys.com/the-system/codesys-inside.html. That should give you a good reference point.
Last updated: 2023-12-31
Post by bingo on PLC Shell commands via ST Code
CODESYS Forge
talk
(Post)
Suppose you need to switch PLC IP dynamically between 192.168.1.10\192.168.2.10, First, set PLC IP to 192.16.1.10. Create a PGVL with a flag ‘xUseSecondry’ xUseSecondry : bool ; create a function that use socket to update IP: FUNCTION fSwitchIP : bool VAR_INPUT useMainIP:bool; END_VAR --------------------------------CODE------ if useMainIP then SysSockSetIPAddress(‘0’, ‘192.168.1.10’); PGVL.xUseSecondry := 0; else SysSockSetIPAddress(‘0’, ‘192.168.2.10’); PGVL.xUseSecondry := 1; end_if Now, if during execution, you need to switch IP, call the function ‘fSwitchIP()’, Set input to 1 for main IP, 0 for secondary IP. In order to set secondary IP at startup, you can do the following: in your PLC_PRG add a flag: xInit : bool := 1 ; and the code: if xInit then if PGVL.xUseSecondry then fSwitchIP(0); end_if xInit := 0 ; end_if *Alternative way is to use system events.
Last updated: 2025-03-03
Post by hemuv on Open Numpad with VU.FbOpenDialogExtended
CODESYS Forge
talk
(Post)
Hello Barton, I try to log the changes in Numpad (upon Ok button pressed) that an Element name/Element text variable is changed from so to so. How to get the Element name (or text fields Text Variable) from where the Numpad is called? Numpad is Invoked from Inputconfiguration->onMouseDown->Write a variable. Thanks
Last updated: 2024-11-07
Post by dhumphries on Control Runtime Toolkit
CODESYS Forge
talk
(Post)
I have a video demonstrating the procedure to install the runtime on a linux device. https://youtu.be/rj0dOhgnGjs?si=OJoA-kgc1saxIweR This demonstration shows how to install the runtime on a X86 based controller, it should be the same for an ARM based device, but you'll need to install the add-in for Codesys control for Linux ARM SL (or the 64 bit add-in.)
Last updated: 2023-12-30
Post by jmauer on Codesys 3.5 SP16 Modbus change port settings.
CODESYS Forge
talk
(Post)
Hello, I'm coming to you today because I'm trying to make the baudrate and the slave number dynamic. I've tried the "updateComPortSettings" method on the slave device but it doesn't work and gives the "Modbus_COM_Port" an error. Can you tell me how you got this method to work? Thanks in advance for your help jérémy
Last updated: 2024-02-20
Post by alessandro on SysMemCmp SysMemCpy
CODESYS Forge
talk
(Post)
VAR Data1:ARRAY[1..10] OF SINT ; Data2:ARRAY[1..10] OF SINT ; Data3:ARRAY[1..10] OF SINT ; Data4:ARRAY[1..10] OF SINT ; ex_1 : BOOL ; ex_2 : BOOL ; enable : BOOL :=0 ; END_VAR // PROGRAM // The scope of this example is compare and copy the values of two ARRAY only if some value is different using SysMemCmp and SysMemCpy. // In this 2 example we don't use a FOR cicle for do this, and pBuffer1 and pBuffer2 is just a pointer to ARRAY. See details in Library util.SysMem of Codesys // The compare funcion util.SysMem.SysMemCmp is bidirectional if Data1 chanege respect Data2 ex_1 go to 1 and if Data2 change respect Data1 also // but the copy function util.SysMem.SysMemCpy work only from source ARRAY pSrc:=ADR(Data1) to destination ARRAY pDest:=ADR(Data2) // Example 1 Full ARRAY compare and copy // This compare 2 different equal ARRAY and if there is some difference ex_1 go to 1 and if you give enable he copy Data1 in Data2 ex_1 := TO_BOOL(util.SysMem.SysMemCmp(pBuffer1:=ADR(Data1), pBuffer2:=ADR(Data2), udiCount:=SIZEOF(Data1))); IF ex_1 AND enable THEN util.SysMem.SysMemCpy(pDest:=ADR(Data2), pSrc:=ADR(Data1), udiCount:=SIZEOF(Data1)); END_IF // Example 2 Only selected area of the ARRAY compare and copy // This compare 2 different equal ARRAY starting from position number [3] for 4 byte in this case start at position [3] and finish at position number [6] // and if there is some difference only in area [3..6] of the ARRAY ex_2 go to 1 if you give enalbe he copy Data3[3..6] in Data4[3..6] // if something change in other array position[0..2] or [7..10] are ingnored ex_2 := TO_BOOL(util.SysMem.SysMemCmp(pBuffer1:=ADR(Data3[3]), pBuffer2:=ADR(Data4[3]), udiCount:=4)); IF ex_2 AND enable THEN util.SysMem.SysMemCpy(pDest:=ADR(Data4[3]), pSrc:=ADR(Data3[3]), udiCount:=4); END_IF // Attention udiCount input is intended in <byte> in the example 1 I pass to udiCount:=SIZEOF(Data1) for compare and copy the intere ARRAY and // SIZEOF pass the size of intere ARRAY in byte to the function input, in this 2 examples I used variable type SINT each one occupie 1 byte and one position in the ARRAY // and in the example 2 I pass udiCount:=4 for compare and copy only 4 position of Data3/4[3..6] if you want to extend this example and use it for an ARRAY OF WORD // remember that each WORD will occupe 2 byte (16 bit) and you will have to pass udiCount:=SIZEOF(Data1) if you need to compare intere ARRAY example 1 // but need udiCount:=(42) for the example 2 because need to compare and copy 4 word each occupie 2 byte (16 bit). // For REAL (32 bit) need udiCount:=SIZEOF(44) for LREAL or (64 bit) need udiCount:=SIZEOF(416) // a good rule is calculate the dimension of the ARRAY in byte without empty space at the end, multiple of data type number for variable bigger then 8 bit // Example : If you want to create an ARRAY for 5 REAL (32 bit) each occupie 4 byte the correct size is ARRAY[0..19] OF REAL 54=20 position. // NOTE : In the example the position of compare function util.SysMem.SysMemCmp is first and the copy function util.SysMem.SysMemCpy inside the IF is after // in one cycle of the program the two array is compared and if there is some difference and enable are copied. // If you move util.SysMem.SysMemCmp after the IF cycle he will copare the ARRAY in the current cycle but the copy of the value will do in the next cycle.</byte>
Last updated: 2025-10-24
RPI How to login for a copy of the SD image
CODESYS Forge
talk
(Thread)
RPI How to login for a copy of the SD image
Last updated: 2023-10-18
Problem with FBD/LD and "Go to the definition" of a Method
CODESYS Forge
talk
(Thread)
Problem with FBD/LD and "Go to the definition" of a Method
Last updated: 2012-02-10
How to record positions in softmotion's x-y axis by X-Y chart of package
CODESYS Forge
talk
(Thread)
How to record positions in softmotion's x-y axis by X-Y chart of package
Last updated: 2018-12-04
How to change the font size of the headline in a table
CODESYS Forge
talk
(Thread)
How to change the font size of the headline in a table
Last updated: 2022-11-25
Trying to negate Boolean values inside of a case statement
CODESYS Forge
talk
(Thread)
Trying to negate Boolean values inside of a case statement
Last updated: 2021-10-29
How to access the value of a variable held in the previous cycle in ST?
CODESYS Forge
talk
(Thread)
How to access the value of a variable held in the previous cycle in ST?
Last updated: 2021-09-01
python script to edit I/O Assignment, [Dynamic Management of I/Os][Compound Safety PLC]
CODESYS Forge
talk
(Thread)
python script to edit I/O Assignment, [Dynamic Management of I/Os][Compound Safety PLC]
Last updated: 2021-07-07
Cannot install runtime mulicore to the newest version of Raspberry Pi4
CODESYS Forge
talk
(Thread)
Cannot install runtime mulicore to the newest version of Raspberry Pi4
Last updated: 2023-07-14
"Out of global data memory". Is there a way to increase the memory?
CODESYS Forge
talk
(Thread)
"Out of global data memory". Is there a way to increase the memory?
Last updated: 2022-03-28
RPi + Codesys: how to obtain a graceful shutdown of the system
CODESYS Forge
talk
(Thread)
RPi + Codesys: how to obtain a graceful shutdown of the system
Last updated: 2018-02-19
What are the network requirements of "Codesys Engeneering" IDE to perform remote access ?
CODESYS Forge
talk
(Thread)
What are the network requirements of "Codesys Engeneering" IDE to perform remote access ?
Last updated: 2020-06-24
Is there any way to get the name of the current action... pou...
CODESYS Forge
talk
(Thread)
Is there any way to get the name of the current action... pou...
Last updated: 2017-03-20
Access to a GVL and seraching for a variable inside of it (Pyhton)
CODESYS Forge
talk
(Thread)
Access to a GVL and seraching for a variable inside of it (Pyhton)
Last updated: 2022-07-25
How to get the amount of free disk space in a plc
CODESYS Forge
talk
(Thread)
How to get the amount of free disk space in a plc
Last updated: 2022-08-08
How to release the memory of a variable in Codesys 2.3
CODESYS Forge
talk
(Thread)
How to release the memory of a variable in Codesys 2.3
Last updated: 2021-06-06