Post by alimans on Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Post)
Hi Kim, Hi eschwellinger, how you could solve the problem? I am using Codesys V3.5.19.60 and I still have the same problem. It will work only after a warm/cold restart. Thank you in advance for your kind help.
Last updated: 2025-10-22
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
i have update the package 4.13 n the computer and install all update for all package, now impossible to start codesys... when i start to open any project i have a message invalid project...
Last updated: 2025-10-26
Post by jeroenaero on Difference between using OPCUA symbol configuration and OPCUA Server object
CODESYS Forge
talk
(Post)
Hi, What is exactly the difference between using symbol configuration as OPCUA server or using the Codesys object OPCUA server? What are the advantages and disadvantages of using symbol configuration and OPCUA server object. Please let me know
Last updated: 2025-10-30
Post by eschwellinger on EtherCAT status errors
CODESYS Forge
talk
(Post)
Setting IRQ priorities using shell commands irq-list and irq-set-prio for the network adapter which is used for Ethercat. This is here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization_linux.html
Last updated: 2025-11-25
Post by micik on Error, visualisation property handling, VISU_USEPROPERTYINFO
CODESYS Forge
talk
(Post)
@davidking, can you be more specific about where exactly "Compiler Defines" is located. I'm using Codesys v3.5 SP21 Patch2 and cannot find this Compiler Defines option. In the menu Project -> Project Settings there are Compiler options and Compiler warnings, but that is not it.
Last updated: 2025-11-26
Post by durallymax on How to use MQTT in CODESYS Control Win V3
CODESYS Forge
talk
(Post)
With the IIoT library/license or the one provided by the hardware OEM. Several examples online of how to use the MQTT Client SL library.
Last updated: 2025-12-12
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi George - ok thanks - but who created this FB in the first place? Could you lead me to the creator company? Is CODESYS not the old S3 that created this FB? :-)
Last updated: 2025-12-17
Post by mariusz997 on Visualisation - internal error
CODESYS Forge
talk
(Post)
Hi - problem solved. I had 3 version of codesys on system and they didn't like each other. After uninstall all and install again only one version now everything is OK
Last updated: 2025-11-12
Post by emmieturner on Which Lib to use, connect to a socket with URL instead of IP address
CODESYS Forge
talk
(Post)
hi, maybe Net Base Services https://forge.codesys.com/prj/codesys-example/nbs/home/Home/ https://geometrydashlite.online Thank for sharing
Last updated: 2025-11-16
Post by davidbo on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Under Application->"Task Configuration" you can find your task double click on that and you will see a fane to the right. You find the watchdog enable switch it off or increase the time
Last updated: 2025-11-17
Post by tristan on Textfield display problem
CODESYS Forge
talk
(Post)
Hello Tim, I am using CODESYS Visu V4.8.1.0. It works when I turn off the "Support client animation and overlay of native elements". But if I do that, dialog box moving and other options are also disabled so it is a bit problematic. Thank you for helping.
Last updated: 2025-11-27
Post by somlioy on Non-formal invocation of function blocks in CODESYS
CODESYS Forge
talk
(Post)
No that is not possible for function blocks, although it is possible to that with methods and functions as you see in your second pic.
Last updated: 2025-12-05
Post by danamocca on SM3_CNC Sentence modifier
CODESYS Forge
talk
(Post)
Hi! Does anyone have an example of ReadNCFile2 with Sentence Modifier? Current examples on CODESYS help page are outdated and have a lot of errors, like "SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH" calls, which are not present in current version of SMC3_CNC library.
Last updated: 4 days ago
Post by damian177 on Codesys V3.5 + Pixtend v1.3 + RaspberryPi
CODESYS Forge
talk
(Post)
Hi, I use Pixtend v1.3 with my RaspberryPi with Codesys V3.5 SP15 Patch1. Actually in my project I used two packages: - CODESYS Contro for Raspberry PI 3.5.15.10 - PiXtend for CODESYS 1.3.8.0 Now I would like to extend my project about the IIot Libraries SL package, I installed them. Next I added SMS_Service_SL 1.0.0.8 version library and I have problem with compile my project because I get error: [ERROR] PiXtend_DemoProject_q: Library Manager [Device: PLC Logic: Application]: Could not open library '#CAADTUtil'. (Reason: The placeholder library 'CAADTUtil' could not be resolved.) Any have idea what can I do to properly add SMS library to my project?
Last updated: 2023-09-26
Post by simotion on Codesys Softmotion Win V3 x64
CODESYS Forge
talk
(Post)
I have a project in Codesys v3.5 sp19 patch2 that contains softmotion virtual axes. I want to simulation the code (softmotion) on the simulated plc on the pc. The controller in the project is a Codesys Softmotion Win V3 x64. I have started up the Codesys Softmotion Win 64 on the pc. However it seems a 3.5 sp14 controller. When trying to download the project, I get a message that target system is different from connected system (3.5.19 vs 3.5.14). How do I set the connected system to 3.5.20 (there seems no way to set the target system to 3.5.14
Last updated: 2023-10-04
Post by janber0206 on Gateway doesn't come online, regarding a working internet connection
CODESYS Forge
talk
(Post)
Solved (see comment) Setup: Kunbus RevPi Connect+ (a raspberry based PLC) Codesys runtime package: 4.5.0.0 (raspberry, armhf) based on Codesys V3.5.18.20 Edge Gateway: 4.5.0.0 (edgearmhf,armhf) EN: The edge-gateway was added over a year ago to the automation server. I now need to make a few changes to the Codesys software, but the Pi is not showing as online in the Automation Server. Internet connection is established, I have remote access to the Pi via RealVNC. Anyone have an idea how I can solve this? Some screenshots added. DE: Ich muss nun ein paar Änderungen an der Codesys-Software vornehmen, aber der Pi wird im Automation Server nicht als online angezeigt. Die Internetverbindung ist hergestellt, ich habe über RealVNC Fernzugriff auf den Pi. Hat jemand eine Idee, wie ich das Problem lösen kann?
Last updated: 2023-10-26
Post by dhumphries on install codesys runtime on linux
CODESYS Forge
talk
(Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04
Post by appling on License status of Linux 64Bit runtime via CLI
CODESYS Forge
talk
(Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04
Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state?
CODESYS Forge
talk
(Post)
Hi there, I'm running the Codesys runtime on Windows 64 and I need to know if it is on "Running" or "Stopped" state just after a system crash. The following commands works perfectly well to (re)start it... net stop “CODESYS Control Win V3 - x64" net start “CODESYS Control Win V3 - x64" ...however I'm unable to determine when it is required to be call; I mean, by checking the System Tray icon, it is possible to know if it is on "Stopped" state, but I wanted to run a .BAT command to retrieve it. How can we do that?
Last updated: 2024-07-02
Post by cfam on Codesys Control for PLCnext SL, Bus not running
CODESYS Forge
talk
(Post)
Good day I would appreciate it if you can give me some advice on how to fix my "Bus Not Running Error". I am Using Codesys 3.5 SP20 and Codesys Control PLCnext SL V4.12.0.0. Codesys control was installed on the device and I can log into it but it seems that it does not pick up the PLC or the IO attached (Please see attached Image). The Bus Cycle Task of the AXL F 2152 is set to Main Task and the "Always update Variable" is Enabled on each IO Module. My Main Task interval is set to 100ms and Priority is set to 0. I have tried other options and none seem to work. Your response to this issue will be highly appreciated.
Last updated: 2024-08-12
Post by cfam on Codesys Control for PLCnext SL, Bus not running
CODESYS Forge
talk
(Post)
Good day I would appreciate it if you can give me some advice on how to fix my "Bus Not Running Error". I am Using Codesys 3.5 SP20 and Codesys Control PLCnext SL V4.12.0.0. Codesys control was installed on the device and I can log into it but it seems that it does not pick up the PLC or the IO attached (Please see attached Image). The Bus Cycle Task of the AXL F 2152 is set to Main Task and the "Always update Variable" is Enabled on each IO Module. My Main Task interval is set to 100ms and Priority is set to 0. I have tried other options and none seem to work. Your response to this issue will be highly appreciated.
Last updated: 2024-08-12
Post by expertplas on No connection to opc server from codesys opc client
CODESYS Forge
talk
(Post)
Hello, we have aproblen to connect our CODESYS OPC Client to the OPC Server. We installed the client according the CODESYS manual. We can browse the server and variables can be linked to the PLC. I created a self signed certificate for the CmpOPCUAClent as described. The server has a cerificate also. I copied the certificates to the trusted zone of server and client. But when it comes to data exchange we get an error message. "Communication error in data source OPC UA Library. Error ID : 7001 German : "Kommunikatinsfehler inder Datenquelle OPC UA -Bibiothek. Es wurde kein genauer Fehler angegeben. Fehler ID : 7001" It semms that there is no cerificate exchange. We are working with CODESYS 3.5 SP19 Patch 5. Can anyone here say something about this error or has an idea for a solution? Thanks.
Last updated: 2024-08-19
Post by fredruel on ModbusServer became unreachable if reach maximum of 16 byClientConnections
CODESYS Forge
talk
(Post)
Hello Fraziersedge, the solution of Codesys might be to update your codesys to the lastest version but it was not possible for us. In our Codesys V3.5 SP9 patch 8 I was able to fix this bug. I change my ModbusTCP slave component version or one of the sub component version (ex: SysSocket). Look at the picture in attachement that's the receipe that have work for us. When I got the bug my version of ModbusTCP slave was 3.5.5.0 with SysSocket at 3.5.6.0 and I change to ModbusTCP slave 3.5.14.0 with same version 3.5.14.0 of SysSocket event if I still use codesys V3.5 SP9 patch 8.
Last updated: 2024-08-27
Post by bjarne-pagaard on OPC UA Server Status on Win RTE
CODESYS Forge
talk
(Post)
Hi there, An "OPC Expert" client software is connecting to a Codesys Control RTE (x64) OPC UA Server. It reads only about 25 variables every 5 minutes. The OPC UA Server seems to shut down on the Codesys runtime. Is there any way to get information about the Codesys OPC UA Server status? Restart it? There is nothing in the PLC Logs after the OPC UA Server has started. It works for a while, then it doesn't. Any ideas? Any way of getting more info out of the Codesys OPC UA Server? -Bjarne
Last updated: 2024-10-21
Post by xabier on BUG CODESYS-NO WORK AUTOMATICALLY RESTARSLAVES
CODESYS Forge
talk
(Post)
I detect a Bug of Codesys....NO WORK AUTOMATICALLY RESTARSLAVES. I explain the secuence: I have click in my project the option AUTOMATICALLY RESTARSLAVES In the moment start my Ipc, the network ethercat start correctly I disconnect the wire of my first slave and later connect again the wire..(see the screen Bug Codesys restart slave1) NO work the restart automatic slaves...and is not possible execute of FB MC_REset beacuause appear this error (see the screen Bug Codesys restart slave2) The only way for resolver this problem is execute the FB SMC3ReinitDrive I replay the same with PLC BECKHOFF in Twincat3 and I havent this problem...In the moment connect the wire again in the slave the comunication of ehterCat restart and the slave comunication again with out problem
Last updated: 2024-11-07
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.