Post by damian177 on CM4S GPIO's in Codesys
CODESYS Forge
talk
(Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28
Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10
Post by mborchert on PFC100 Error "Bus not running"
CODESYS Forge
talk
(Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17
Post by ron-rp on Errors with VisuUserManagement library
CODESYS Forge
talk
(Post)
Hi all, I've played a bit with the VisuUserManagement library, and some other security option in my project, and I started getting this error when logging in - see attached pic. something to do with a specific screen in the library - VUM_Login. Also, Codesys started to ask me to log in to the library when logging in, asking to log in as user of the groups Maintainer or Owner, which I dont know either users (attached pic). when I close the login screen and try to log in to the PLC again, everything works again until I close and open Codesys. I do use user and password to login to the PLC, and this login screen is fine I know the user and pass I setup. anyone know what did I do wrong here and how to fix it?
Last updated: 2024-06-25
Post by kunz on Responsive Design Example
CODESYS Forge
talk
(Post)
Hello everyone, I have a problem with the example project Responsive Design Example, which is available here in Codesys Forge. I wanted to try switching the visualization depending on the device type. To do this, I used a smartphone to access it. I can see via breakpoints that the Smartphone visualization is selected, but the visualization of the normal monitor still appears on the smartphone. Could there be a problem with the libraries, or why is the device not assigned the correct visualization page? I dont know how do further debuggin or troubleshooting. Here the page to the example: https://forge.codesys.com/prj/codesys-example/responsive-desi/home/Home/ Thank you very much.
Last updated: 2024-06-27
Post by peterned on Programatically restart Codesys OPC UA server?
CODESYS Forge
talk
(Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19
Post by askic on Generate FBs from source
CODESYS Forge
talk
(Post)
Hello, I'm coming from Siemens (TIA) world and currently learning Codesys. I'd like to know if there is an option to add external txt file with ST code for creation of a function block and then use this file as a source file from which FB will be generated? For example, in TIA, there is an option add external source file to the project structure and then use option "Generate blocks from source". This would create a FB. Does Codesys have something similar? This external source file would look like this: FUNCTION_BLOCK Scaling VAR_INPUT x, k, n : REAL; END_VAR VAR_OUTPUT y : REAL; END_VAR VAR END_VAR y := k*x+n; END_FUNCTION_BLOCK
Last updated: 2024-07-31
Post by jnoyau on Visualisaion while in simulation
CODESYS Forge
talk
(Post)
Hi all, Im new to Codesys 3.5, and am in the process fo making a visualisation i'd eventually export towards a Wago device. The issue I'm having currently is that when I compile and connect to the simulated program, my simulation won't launch. On the Visualisation tab, all I get is a text message (where previously there was my prepared visualisation) that says "The visualisation awaits a connection. Start the application" One thing to note: I work with Codesys 3.5 in french, so this is a rough translation. And a second: I'm not getting any errors nor warnings about the visualisation tab itself upon compiling Is there a step i'm missing after launching my simulation? Or would it be some really specific issue caused by the way I've set up my program? Thanks, J
Last updated: 2024-07-31
Post by c3po on SNMP Communication with WAGO 750-8212 PFC
CODESYS Forge
talk
(Post)
Hello folks, my problem is a bit bigger for just one question. So let's start with the easiest. But first, my system setup: It's a WAGO 750-8212 PFC with some I/O-modules. I try to communicate with the controlsystem over SNMP using the IIoT library from codesys. https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_iot_snmp_service.html Is there some expirience with this kind of communication? It's just about transfering some data from PFC to network and setting some analogsettings from network to the PFC. So my easiest question: Do I ever need the SNMP_Agent or can I use the SET / GET function as standalone, without the agent? (maybe some more questions will follow, if someone will answer to my request) thanks so far
Last updated: 2024-08-21
Post by khaledkhalil on Question about the hairaichy of UaExpert
CODESYS Forge
talk
(Post)
Hello, I am Examining this Example from Codesys Tutorial about OPC-UA server here https://www.youtube.com/watch?v=aJhzN3Uk-Do&list=PLWtD08CpmZcSV26aWh1axCAef5c5HxX-3&index=1&t=1167s. Now i am running to problem, when i create instances and i want them to appear directly under the object directory, However, it always appear with me under Objects >> Device set >> Device Name in CODESYS. I need to know how i can change the directory of my instances 'inst_3' and so on. So they can be under objects directly. I tried to modify the settings, but couldn't find any leads till now. Thanks in advance for helping
Last updated: 2024-09-12
Post by yannickasselin on codesys VLAN tagging
CODESYS Forge
talk
(Post)
I ordered a cheap managed switch and tested it as soon as I received the switch. It works great! I even went a bit further. As you can see in the screenshot, I created 2 Codesys containers. Each one having 2 fieldbuses. The first one has EtherCAT and EtherNet/IP and the second one has EtherCAT and Modbus/TCP. All going through the same ethernet port from the PC to the switch. The switch splits it up into 4 different networks. The hardest part was to figure out how to configure the switch. @eschwellinger, thank you very much.
Last updated: 2024-09-17
Post by pierre on difference between stub file and source file in scriptengine
CODESYS Forge
talk
(Post)
I included the stub files of scriptengine (codesys python api) in a directory scriptengine of a project. I tried to include librarymanager like that: from scriptengine import librarymanager visual studio code detected an error. It said librarmanager could not be found. Indeed in the stub file, this was library_manager. But if I change it in my code, the plugin doesn t work anymore. I found an easy solution to this problem. I ve just changed the copied stub files.(library_manager -> librarymanager) But I think it would be better if you update it yourself in the future.
Last updated: 2024-09-20
Post by pierre on difference between stub file and source file in scriptengine
CODESYS Forge
talk
(Post)
I included the stub files of scriptengine (codesys python api) in a directory scriptengine of a project. I tried to include librarymanager like that: from scriptengine import librarymanager visual studio code detected an error. It said librarmanager could not be found. Indeed in the stub file, this was library_manager. But if I change it in my code, the plugin doesn t work anymore. I found an easy solution to this problem. I ve just changed the copied stub files.(library_manager -> librarymanager) But I think it would be better if you update it yourself in the future.
Last updated: 2024-09-20
Post by andrebrandt on FB string and naming
CODESYS Forge
talk
(Post)
Thank you so much. This worked. Waht im trying to do here is to automatically tag each sensors, valves and so on. There is a preatty nasty tag system i working on. "_320" is not alloved. I can have a tag "+4f=320.004-RT001V" In codesys I want to build the FB in folders. -4f | --320 | --001 This is the system structure. Inside here is all of the sensors and so on. But with Codesys, I cannot tag this like this. So what I'm trying to do now is to Make a folder for the building "4f" and one for the system "320", and a POU _001. Is there a way in init to get folder names?
Last updated: 2024-10-01
Post by ivanj on Codesys V3 + Rpi + PCA9685 + two robot arms
CODESYS Forge
talk
(Post)
greetings to everyone I have a system consisting of rpi3 computer with codesys v3 installed connected to one pca9685 through which the servo motors of the two robotic arms are connected (each robot arm has 6 motors) I managed to get that the pca9685 can only drive 4 servos on the first arm the other 2 on the same robot arm do not respond, nor do the remaining 6 they do not react on the other robotic arm. Power is connected to the pca9685 for motors of sufficient power or amperage. I tried to put another pca9685 but the same thing happens again. What is the possible problem?
Last updated: 2024-10-02
Post by rmaas on TargetVisu for Linux SL not starting
CODESYS Forge
talk
(Post)
Hello, I am trying to get TargetVisu for Linux working but i am having some troubles. The problem is that after installation it is not starting automatically on boot and i cannot start it from the update Targetvisu tool. When i try i get the following error (see attached screenshot) The file /opt/codesysvisualization/scripts/codesysvisualization_start.sh is missing... Steps performed: - installed fresh Debian 12.7 on virtual machine - installed all required libraries as described here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html - then installed the TargetVisu for Linux SL 4.13.0.0 using the Codesys IDE Does someone know how i can fix this? Best Regards, Rinie
Last updated: 2024-10-02
Post by dsa28 on OPC UA subscriber not operational
CODESYS Forge
talk
(Post)
Hello All, Hopefully I can get some help configuring an OPC UA subscriber in a CODESYS runtime in a Raspberry Pi 5 that tries to retrieve data from an OPC UA publisher (in this case running in a TwinCAT system). I tried to follow the steps described in the page to implement the OPC UA subscriber: https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_opcua_pubsub.html Seems that the example provided was created with version 3.5.16.0. Now with version 3.5.20.20 is not possible to open the complete project neither convert it. Anyway, after configuring all IPs and ports used in the OPC UA connection function block but the connection state always shows DISABLED. Can someone help me to do the proper configuration of the OPC UA subscriber? Many thanks in advance.
Last updated: 2024-10-22
Post by etienneneu on loading delay with the option "check client animations and overlay of native elements"
CODESYS Forge
talk
(Post)
Hello guys, I have the following problem with the Codesys visualization (4.6.0) and Codesys V3.5.20.20. I would like to use my own HTML5 elements for my visualization. To do this, I have to select the option “Support client animations and overlay of native elements” in the visualization manager. But with the selection of this option, the visu has a massive loading delay when changing frame content. This happens even if I have not even added HTML5 elements. However, if this option is deactivated, then changing the content of the frames works without any problems, it loads instantly. I have already tried to change various refresh rates but without success. Have any of you experienced this and been able to fix it?
Last updated: 2024-10-30
Post by pistola on Case Function - Multiple Conditions, Is it possible?
CODESYS Forge
talk
(Post)
Looking at the help (https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_st_instruction_case.html). I don't think it is possible but I figured I'd ask. I'm looking at have a case that evaluates two variables, instead of having multiple If Else statements I was hoping I could just use a case. Example * Case Var1 & Var 2 of 10 & 10: Instruction Code 10 & 20: Instruction Code 20 & 20: Instruction Code End_Case Obviously I tried typing as noted above and Codesys threw an error. But I was wondering if there was a different way of programming to make something like this work? If not I'll just use a bunch of If Else Statements, Thanks.
Last updated: 2024-11-03
Post by sigurdrb on Codesys and error messages, warnings exceptions etc.
CODESYS Forge
talk
(Post)
Hi, I tried some different libraries (CmpApp etc.) to find some global variables that I could read out as a variable in the codesys environment. Do any one of you know which libraries are best suited for this, and how I can read it out? My goal is to send messages, warnings etc. to the system that communicates to the PLC. Currently if something goes wrong I need to see the logfiles, or go online with the controller. I think I could save a lot of time if I could read the errors from our user interface that is connected to the PLC by TCP/IP.
Last updated: 2024-11-06
Post by gatto on Undertanding Application Based Licenses
CODESYS Forge
talk
(Post)
Hi, i think you are right. Did you press the key shopping cart? Codesys tells you the license. What I don't appreciate is that i need an additional license for communication. The system reports opc ua but this cheats you. This is communication that also concerns the tag symbols that codesys eth v3 exchanges with an operator panel. Attached is a screenshot of my case where you can see that communication opc ua is cheating you. 512 tags included in the program license are few. So, I had to buy 2 licenses. one for the program and one for communication. I don't like this policy.
Last updated: 7 days ago
Post by ellocco on Kann mich nicht am Gerät anmelden
CODESYS Forge
talk
(Post)
CODESYS V3.5 SP18: Mit Hilfe eines anderen Forumsbeitrags von @automa konnte ich ein Problem lösen: Ich kann mich wieder beim (virtuellen) Gerät anmelden. :-) Die Lösung ist das Löschen bestimmter Dateien oder eines ganzen Ordners: Ich habe den ganzen Ordner (nachdem ich eine Sicherheitskopie angefertigt hatte) gelöscht. Es ist ein Ordner unterhalb von: c:\Users\All Users\CODESYS\CODESYSControlWinV3x64\ Es ist für mich ein wenig überraschend, den Ordner "c:\Users\All Users" kann ich bei mir gar nicht sehen und wenn ich ihn öffne, werde ich umgeleitet auf: "C:\ProgramData". Aber die andere Frage bleibt offen, wie kann ich die Sicherheitsverwaltung aktivieren?
Last updated: 6 days ago
Post by mogam on Internal error:System.NullReferenceException: The object reference was not set to an object instance.
CODESYS Forge
talk
(Post)
Hi everyone, I have a my App that reads values from a shared memory than 2 variables x,y were calculated. here as you can see in my code: PROGRAM PLC_PRG VAR szName : STRING := '/SM'; ( Name of the shared memory.) uxiSize : __UXINT := 646 * 2 * SIZEOF(REAL); ( Size of the shared memory. ) hShm : RTS_IEC_HANDLE; ( Handle to the shared memory ) pStart : POINTER TO REAL; ( Pointer to the first element in the memory ) pData : POINTER TO REAL; ( Pointer, which is incremented until the last sign in the memory is reached. ) shared_data :ARRAY[0..645, 0..1] OF REAL; velocity : ARRAY[0..2] OF REAL; ( Velocity array ) position : ARRAY[0..2] OF REAL; ( Position array ) angleDepth : ARRAY[0..645, 0..1] OF REAL; ( Angle and depth array ) xEndOfMemory : BOOL; x : ARRAY[0..645] OF REAL := 1.0; y : ARRAY[0..645] OF REAL := 1.0; (* Result of actions at the memory. *) OpenResult : RTS_IEC_RESULT; ReadResult : RTS_IEC_RESULT; PointerResult : RTS_IEC_RESULT; DeleteResult : RTS_IEC_RESULT; CloseResult : RTS_IEC_RESULT; i : INT; END_VAR ( Open the shared memory ) hShm := SysSharedMemoryOpen2(szName, 0, ADR(uxiSize), ADR(OpenResult)); IF hShm <> RTS_INVALID_HANDLE THEN (* Read the entire shared memory table *) SysSharedMemoryRead(hShm:= hShm, ulOffset:= 0, pbyData:= ADR(shared_data), ulSize:= uxiSize, pResult:= ADR(ReadResult)); (* Fetch the pointer from the shared memory. The pointer is pointing to the first element address *) //pStart := SysSharedMemoryGetPointer(hShm, ADR(PointerResult)); (* Close the shared memory *) //CloseResult := SysSharedMemoryClose(hShm := hShm); (* Read velocity and position data from the shared memory *) FOR i := 0 TO 2 DO velocity[i] := shared_data[i, 0]; position[i] := shared_data[i, 1]; END_FOR; (* Read angle and depth data from the shared memory *) FOR i := 0 TO 645 DO angleDepth[i, 0] := shared_data[(i + 6), 0]; angleDepth[i, 1] := shared_data[(i + 6), 1]; END_FOR; FOR i := 0 TO 645 DO x[i] := angleDepth[i, 1]*COS(angleDepth[i, 0]); y[i] := angleDepth[i, 1]*SIN(angleDepth[i, 0]); END_FOR; END_IF For these values an XY-CHART needs to be done and when i create a visualisation and set the x data and y data when i try to compile, i recieve this error: ------ Übersetzungslauf gestartet: Applikation: Device.Read_App ------- Code typisieren ... [FEHLER] Internal error:System.NullReferenceException: Der Objektverweis wurde nicht auf eine Objektinstanz festgelegt. bei _3S.CoDeSys.LanguageModelManager.LDateType.Accept(ITypeVisitor typvis) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IArrayType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , _IPreCompileContext , _ICompileContext , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , Boolean , Boolean , _IPreCompileContext , _IPreCompileContext , _ICompileContext , Boolean , Boolean& , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(Guid , Boolean , Boolean , Boolean , Boolean& , _ICompileContext& , _ICompileContext& , IProgressCallback , Boolean , Boolean ) Kompilierung abgeschlossen -- 1 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 1 Fehler, 0 Warnungen : Kein Download möglich!
Last updated: 2024-05-24
Post by mogam on Internal error:System.NullReferenceException: The object reference was not set to an object instance.
CODESYS Forge
talk
(Post)
Hi everyone, I have a my App that reads values from a shared memory than 2 variables x,y were calculated. here as you can see in my code: PROGRAM PLC_PRG VAR szName : STRING := '/SM'; ( Name of the shared memory.) uxiSize : __UXINT := 646 * 2 * SIZEOF(REAL); ( Size of the shared memory. ) hShm : RTS_IEC_HANDLE; ( Handle to the shared memory ) pStart : POINTER TO REAL; ( Pointer to the first element in the memory ) pData : POINTER TO REAL; ( Pointer, which is incremented until the last sign in the memory is reached. ) shared_data :ARRAY[0..645, 0..1] OF REAL; velocity : ARRAY[0..2] OF REAL; ( Velocity array ) position : ARRAY[0..2] OF REAL; ( Position array ) angleDepth : ARRAY[0..645, 0..1] OF REAL; ( Angle and depth array ) xEndOfMemory : BOOL; x : ARRAY[0..645] OF REAL := 1.0; y : ARRAY[0..645] OF REAL := 1.0; (* Result of actions at the memory. *) OpenResult : RTS_IEC_RESULT; ReadResult : RTS_IEC_RESULT; PointerResult : RTS_IEC_RESULT; DeleteResult : RTS_IEC_RESULT; CloseResult : RTS_IEC_RESULT; i : INT; END_VAR ( Open the shared memory ) hShm := SysSharedMemoryOpen2(szName, 0, ADR(uxiSize), ADR(OpenResult)); IF hShm <> RTS_INVALID_HANDLE THEN (* Read the entire shared memory table *) SysSharedMemoryRead(hShm:= hShm, ulOffset:= 0, pbyData:= ADR(shared_data), ulSize:= uxiSize, pResult:= ADR(ReadResult)); (* Fetch the pointer from the shared memory. The pointer is pointing to the first element address *) //pStart := SysSharedMemoryGetPointer(hShm, ADR(PointerResult)); (* Close the shared memory *) //CloseResult := SysSharedMemoryClose(hShm := hShm); (* Read velocity and position data from the shared memory *) FOR i := 0 TO 2 DO velocity[i] := shared_data[i, 0]; position[i] := shared_data[i, 1]; END_FOR; (* Read angle and depth data from the shared memory *) FOR i := 0 TO 645 DO angleDepth[i, 0] := shared_data[(i + 6), 0]; angleDepth[i, 1] := shared_data[(i + 6), 1]; END_FOR; FOR i := 0 TO 645 DO x[i] := angleDepth[i, 1]*COS(angleDepth[i, 0]); y[i] := angleDepth[i, 1]*SIN(angleDepth[i, 0]); END_FOR; END_IF For these values an XY-CHART needs to be done and when i create a visualisation and set the x data and y data when i try to compile, i recieve this error: ------ Übersetzungslauf gestartet: Applikation: Device.Read_App ------- Code typisieren ... [FEHLER] Internal error:System.NullReferenceException: Der Objektverweis wurde nicht auf eine Objektinstanz festgelegt. bei _3S.CoDeSys.LanguageModelManager.LDateType.Accept(ITypeVisitor typvis) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IArrayType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IPointerType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei ..(_ISignature , _IPreCompileContext ) bei ..( ) bei ..(String ) bei ..(String , IVariable[]& , ISignature[]& ) bei ..(String , IVariable[]& , ISignature[]& , IScope& ) bei ..visit(_IVariableExpression , AccessFlag ) bei ..(_IUserdefType ) bei ..(_IVariable , IScope5 , _ICompileContext , _ISignature ) bei ..(_ISignature , IScope5 , _ICompileContext ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , _IPreCompileContext , _ICompileContext , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(_ICompileContext , Boolean , Boolean , _IPreCompileContext , _IPreCompileContext , _ICompileContext , Boolean , Boolean& , IProgressCallback ) bei _3S.CoDeSys.Compiler35140.Compiler.(Guid , Boolean , Boolean , Boolean , Boolean& , _ICompileContext& , _ICompileContext& , IProgressCallback , Boolean , Boolean ) Kompilierung abgeschlossen -- 1 Fehler, 0 Warnungen Übersetzung abgeschlossen -- 1 Fehler, 0 Warnungen : Kein Download möglich!
Last updated: 2024-05-24
Post by lsislsis on SIGABRT Error
CODESYS Forge
talk
(Post)
Please help us. Why we take this errors. We try different versions like 4.12.0 and 4.13.0 with same results. ;*********;<loggername>codesyscontrol.log</loggername>;<logoptions>; <enable>1</enable>; <type>normal</type>; <timestamp>rtc high resolution</timestamp>; <deactivatable>0</deactivatable>; <dump>always</dump>; <filter>0x0000000f<filter>; <maxentries>100000</maxentries>; <maxfiles>1</maxfiles>; <maxfilesize>1000000</maxfilesize>;</filter></filter></logoptions>;<entries>;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText;ClassId: LOG_INFO =1;ClassId: LOG_WARNING =2;ClassId: LOG_ERROR =4;ClassId: LOG_EXCEPTION =8;ClassId: LOG_DEBUG =16;ClassId: LOG_PRINTF =32;ClassId: LOG_COM =64;</entries>;*********2024-11-05T08:23:59.728Z, 0x0000100c, 1, 0, 0, VisuFctCheckForUnusedClients: Removing Client with IEC-ID: 1 Time delta: T#33s1ms Locks: Paintbuffer: TRUE 2024-11-05T08:23:59.728Z, 0x0000100c, 1, 0, 0, VisuFctCheckForUnusedClients: Successfully Removed Client at Address: 547195449944, IEC-ID was: 1, EXT-ID: 431000373 2024-11-05T08:28:57.913Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 347055752 2024-11-05T08:28:57.926Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 347055752 Returned IEC-ID: 1 2024-11-05T08:30:51.103Z, 0x0000100c, 1, 0, 0, Visu_PRG: Successfully Removed Client with IEC-ID: 1, Extern-ID: 347055752 2024-11-05T08:37:36.517Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state* We recommend a reboot of the controller now! 2024-11-05T08:37:36.517Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2024-11-05T08:47:42.117Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T08:47:42.117Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2024-11-05T09:14:41.316Z, 0x00000071, 1, 0, 13, Webserver stopped 2024-11-05T09:14:44.485Z, 0x0000013d, 1, 0, 4, Number of licensed cores for IEC-tasks: 1 from 4 2024-11-05T09:14:44.487Z, 0x0000013d, 1, 0, 4, Number of licensed cores for IEC-tasks: 4 from 4 2024-11-05T09:14:44.540Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [Download] 2024-11-05T09:14:55.894Z, 0x00001012, 1, 0, 0, Opened alarm storage file, version: 6 2024-11-05T09:14:55.951Z, 0x0000100c, 1, 0, 0, Visuinitialization starting. 2024-11-05T09:14:55.983Z, 0x0000100c, 1, 0, 0, Visuinitialization done. 2024-11-05T09:14:55.995Z, 0x00000071, 1, 0, 12, Webserver started 2024-11-05T09:15:01.753Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 2279884529 2024-11-05T09:15:01.753Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 2279884529 Returned IEC-ID: 0 2024-11-05T09:34:44.667Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T09:34:44.667Z, 0x00000111, 8, 260, 3, #### Exception: More than 2 exceptions in CH_COMM_CYCLE: Stop logging 2024-11-05T10:13:26.867Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:15:21.966Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:19:12.167Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:26:02.566Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T10:31:42.866Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T11:01:54.468Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T11:09:29.868Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! 2024-11-05T11:14:44.540Z, 0x0000100d, 1, 0, 0, Demo mode expired. 2024-11-05T11:27:20.868Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state We recommend a reboot of the controller now! * Regards
Last updated: 2024-11-05