Search talk: Codesys C code integration

 
<< < 1 .. 750 751 752 753 754 .. 912 > >> (Page 752 of 912)

Using ATSCADA iEnergy Tools for SCADA-Based Energy Monitoring CODESYS Forge talk (Thread)
Using ATSCADA iEnergy Tools for SCADA-Based Energy Monitoring
Last updated: 2026-06-13

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
...
Last updated: 2026-06-15

EVC - issues assigning variables from VarGlobal lists CODESYS Forge talk (Thread)
EVC - issues assigning variables from VarGlobal lists
Last updated: 6 days ago

Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation CODESYS Forge talk (Post)
Good morning, I’ve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object I’m running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I don’t understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesn’t report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case I’m working on an isolated single core. I’ve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. I’d like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11

Post by timvh on Sorting array of any-sized structure CODESYS Forge talk (Post)
Look all the way at the end of the link below. This provides a way to use arrays with various lengths: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_array.html
Last updated: 2023-08-18

Post by arvind on communication CODESYS Forge talk (Post)
HI All past two weeks im trying to configure and establish communication between wago rs485 fieldbus coupler(750-315/300-000) with wago pfc 200 plc but not able to communicate can you peoples help me to configure and establish communication using codesys v3.5 and above
Last updated: 2023-08-19

Post by eschwellinger on communication CODESYS Forge talk (Post)
depends on if you use PFC200 SL from CODESYS store or the Wago target for the PFC. If you use the SL product you need to setup the interface by a plcshell command...
Last updated: 2023-08-19

Post by eschwellinger on Stop raspberry from executing a plc program CODESYS Forge talk (Post)
/var/opt/codesys/PLCLogic as soon you have dowloaded the project to the Pi it will run the bootapplication no connection to the pc is needed anymore
Last updated: 2023-08-24

Post by eschwellinger on Same program to more than one PLC CODESYS Forge talk (Post)
just open http://localhost:8080 in Chromium then it will show the webvisu ( sure you need to this in your CODESYS Application)
Last updated: 2023-08-24

Post by bagusd on gateway problem CODESYS Forge talk (Post)
hello, I have a problem with the gateway not being able to connect to the plc, does anyone know why the gateway is difficult to connect to the plc? even though the lan cable has been connected to the plc and codesys gateway V3 has been restarted, thank you
Last updated: 2023-08-25

Post by sedoerr on Warnung C0373 / Dialog nicht instanziert CODESYS Forge talk (Post)
Hallo Leute, in meinem Projekt bekomme ich mehrfach folgende Warnung beim Übersetzen: C0373: Dialog <visudialogs.textinputwithlimits> ist in der Applikation nicht instanziert. Fehlt er im Visualization Manager?</visudialogs.textinputwithlimits> Was genau möchte mir Codesys damit sagen bzw. wie bekomm ich diese Warnung behoben? MFG
Last updated: 2023-08-29

Post by roundex on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
I got same issue but managed to get it to work again by downgrading the Runtime. Here's my specs: CODESYS V3.5.19.0 Runtime Linux SL 4.7.0.0. CSV Utility SL 1.1.0.0 (Licensed IIoT libraries SL) I tried Runtime 4.8.0.0. and 4.9.0.0 but both result in INVALID_HANDLE error.
Last updated: 2023-08-30

Post by tvm on Ranges, Lambdas, on Fixed arrays of structs CODESYS Forge talk (Post)
Have you looked at this? https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ It's not exactly what you're looking for, but I've been able to make some things work more efficiently using this library.
Last updated: 2023-08-31

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
please use latest version 4.9.0.0 and it is mandatory to have a user pi on your device.
Last updated: 2023-09-11

Post by chris12345 on OPC UA datasource low read frequency CODESYS Forge talk (Post)
Hi yr00, the default sampling interval is set to 1s. you can generate your own client settings, this link should help you:- https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2023-09-13

Post by chris12345 on OPC UA datasource low read frequency CODESYS Forge talk (Post)
Hi yr00, the default sampling interval is set to 1s. you can generate your own client settings, this link should help you:- https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2023-09-13

Post by eschwellinger on RPI Zero w - Edge gateway cant install CODESYS Forge talk (Post)
check 'uname -a' by ssh connection - addtional you'll probaly find the reason for not running with application by 'cat /var/opt/codesys/codesyscontrol.log' incase you are using 4.9.0.0 runtime version
Last updated: 2023-09-13

Post by danwoodlock on RPI Zero w - Edge gateway cant install CODESYS Forge talk (Post)
Thanks very much for the explanation. I am basically new to the rpi world, but somewhat familiar with the indraworks/CtrlX versions of codesys. Appreciate your help.
Last updated: 2023-09-13

Post by eschwellinger on RPI Zero w - Edge gateway cant install CODESYS Forge talk (Post)
ok now it is clear - this is a single core Pi Zero W. For this device there is no edge device available. But just for working with CODESYS it is not really needed and yes plc runs only for 2h unlicensed.
Last updated: 2023-09-13

Post by transmin01 on PCAN serial "No CAN driver found" CODESYS Forge talk (Post)
Second question is, how do I determine the correct network ID for my Canbus config in Codesys? I have 2 CANbus ports on the target PC. Regards Trevor
Last updated: 2023-09-14

Post by chris12345 on Calling OPC UA Methods from UaExpert CODESYS Forge talk (Post)
Hi, Is it possible to generate an .xml file with FBs and methods from Codesys? Or do I need a separate program to generate the .xml file? Or is there a otherway to use methods via opc ua from the own project?
Last updated: 2023-09-20

Post by fleaplc on FILE_OPERATION_DENIED CODESYS Forge talk (Post)
By using the CAA FILE library (FB FILE.Open) (raspberry pi, codesys 3.5.19.0) I always get the error FILE_OPERATION_DENIED The file exist, it has r/w/x access and path is correct... Some idea to fix it?
Last updated: 2023-09-25

Post by rschwager on description about the build compiler definition CODESYS Forge talk (Post)
Hi CODESYS moderators and user! Is there any description about the compiler definition in property of application? e.g.: CANOPEN_NO_HEARTBEATPRODUCING Is there more definition? Best regards Robert
Last updated: 2023-09-26

Post by simond on The required device description is not installed.. CODESYS Forge talk (Post)
Hi folks, can someone please tell me how to go about fixing this issue? I am getting this error when I implement an instance of the J1939_Manager. Thanks Simon
Last updated: 2023-10-03

Post by tomas111 on Help with error C0142 CODESYS Forge talk (Post)
There was an exact mistake. I did as they wrote. I created a visualization and transferred it from the old one and everything works. CS 3.5 SP 19. Thank you.
Last updated: 2023-10-04

<< < 1 .. 750 751 752 753 754 .. 912 > >> (Page 752 of 912)