Post by paulg on Converting hex bytes to float
CODESYS Forge
talk
(Post)
I'll be capturing a hex stream over serial into a RasPi and I'd like to convert a group of bytes into a float. I see this is available (https://content.helpme-codesys.com/en/CODESYS%20Development%20System/cdsoperatorrealto.html) but not its inverse (i.e. BYTE_TO_REAL). The packets will be 18 bytes but I'll be selecting 4 byte segments from the middle, swapping byte endianness (i.e. changing 0x51847641 to 0x41768451), and converting to float; I believe they adhere to IEEE 754. Is there a pre-built function for some or all of this, or do I need to follow (https://forge.codesys.com/forge/talk/Engineering/thread/dc5829c7ea/)? Thanks!
Last updated: 2024-08-02
Post by paulpotat on Exclude traces when searching with ctrl+F
CODESYS Forge
talk
(Post)
Hello, I was wondering if there is a way in codesys to exclude the traces from the search when using the "ctrl+F" window ? That would be nice to improve the search functionnality when looking for a specific variable. Sometimes when I iterate through all occurences with the "find next" button, it opens the trace configuration window. I would expect to be able to close it and go to the next occurence with the "find next" button, but after closing the trace configuration window the search says it has reached the end of the scope (even if in reality there are other occurences of the variable elsewhere). I tried to enable / disable the "search up" checkbox but it's not changing anything. I hope somebody have insight on this, BR
Last updated: 2024-08-06
Post by micik on Download EtherCAT project on SoftPLC (ControlWin-V3 x64)
CODESYS Forge
talk
(Post)
Hello, I have almost exactly problem already discussed here in this old thread: https://forge.codesys.com/forge/talk/Engineering/thread/03af9426eb/ However, this is quite old and I assume not completely relevant. In my case, I use v3.5.20 on windows 11, so Winpcap is no longer supported on newer OS. Also, this hint about adding entry to the .cfg file under ProgramFiles(x86) is also not relevant anymore. I guess, I need to add entry SysEthernet to this .cfg file: C:\ProgramData\CODESYS\CODESYSControlWinV3x64...\CODESYSControl.cfg like this one: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=SysEthernet But I'm not sure about Npcap vs WinpCap. Please, if applicable, update these instructions.
Last updated: 2024-08-08
Post by micik on Ethercat project loaded to Win V3 x64 bit SoftPLC
CODESYS Forge
talk
(Post)
Hello, I have almost exactly problem already discussed here in this old thread: https://forge.codesys.com/forge/talk/Engineering/thread/03af9426eb/ However, this is quite old and I assume not completely relevant. In my case, I use v3.5.20 on windows 11, so Winpcap is no longer supported on newer OS. Also, this hint about adding entry to the .cfg file under ProgramFiles(x86) is also not relevant anymore. I guess, I need to add entry SysEthernet to this .cfg file: C:\ProgramData\CODESYS\CODESYSControlWinV3x64...\CODESYSControl.cfg like this one: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=SysEthernet But I'm not sure about Npcap vs WinpCap. Please, if applicable, update these instructions. I hope it is still possible to
Last updated: 2024-08-22
Post by micik on Reverse bytes in an array
CODESYS Forge
talk
(Post)
Hello, I'm getting the data in Codesys that is an array of 8 bytes. From this array, I need to foram LREAL number, however, because of different endiannes I need to reverse bytes in this array and then copy to a LREAL variable. For this I'm using a loop and it works OK. I wonder if there is a built in function to do this. I have found CAA Memory library but it has functions like reverse bytes in DWORD. But it seems it doesn't have what I need. https://content.helpme-codesys.com/en/libs/CAA%20Memory/Current/CAA_Memory/Reverse-Bit-Swap-ByteWord-order/ReverseBYTEsInDWORD.html What I need is a function to reverse bytes in an 8 byte array, or something similar.
Last updated: 2024-08-22
Post by micik on Reverse bytes in an array
CODESYS Forge
talk
(Post)
Hello, I'm getting the data in Codesys that is an array of 8 bytes. From this array, I need to foram LREAL number, however, because of different endiannes I need to reverse bytes in this array and then copy to a LREAL variable. For this I'm using a loop and it works OK. I wonder if there is a built in function to do this. I have found CAA Memory library but it has functions like reverse bytes in DWORD. But it seems it doesn't have what I need. https://content.helpme-codesys.com/en/libs/CAA%20Memory/Current/CAA_Memory/Reverse-Bit-Swap-ByteWord-order/ReverseBYTEsInDWORD.html What I need is a function to reverse bytes in an 8 byte array, or something similar.
Last updated: 2024-08-22
Post by lukebouchard on NVL generating ADwin packets instead of UDP?
CODESYS Forge
talk
(Post)
Using Codesys 3.5 SP11 32bit to program a pair of IFM CR711S controllers. They each have an NVL sender and are set up to receive each others messages. One is transmitting properly but not receiving, the other is receiving the first's messages just fine. When I look at the traffic in wireshark, I can see the one transmitting properly as UDP packets on the subnet and port I had specified. The Second is transmitting on the right subnet and port, but is sending 'ADwin Config' packets. Has anyone run into anything simmilar? From some reading on ADwin from google, nothing is enlightening. Both are set up in the same way, have their own ports and List Identifiers. I have deleted the NVL files and regenerated them, cycled power, and even deleted and remade the NVL's so many times.
Last updated: 2024-08-24
Post by hfelek on TargetVisu for Linux Package on runtime 4.12.0.0 install error due to Qt dependencies.
CODESYS Forge
talk
(Post)
Hi, I am trying to make my runtime support TargetViso on 4.12.0.0 runtime. First when I tried to install package I got error due to missing libraries that are generated through qt-base. After compiling and installing related qt lib when I tried to install the package, I didnt get lib dependencies error but I got another error: [ERROR] The installed QT Version does not meet the minimum required version 6.4.2. Please install version 6.4.2 or higher and try again. When I check Qt version I get the following response QMake version 3.1 Using Qt version 6.5.0 in /usr/local/qt6/lib. I tried with Qt version 6.9.0 but that didn't help. Any idea on what coudl be the reason. When I looked for codesys related processes the related libraries were included within environment.
Last updated: 2024-08-27
Post by elektron785 on Dongle von Linux-Modul (ARM64) nicht erkannt
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe Lizenzen für CoDeSys gekauft und auf einem Dongle installiert, in der Hoffnung, dass ich diese mit einem Verdin-Modul von Toradex verwenden kann. Leider wird mir aber im Lizenz-Manager angezeigt, dass der Dongle nicht gesteckt ist. Ich habe bereits beide USB-Ports versucht, aber die Fehlermeldung bleibt gleich. Ist das überhaupt die richtige Vorgehensweise über den Lizenz-Manager oder gibt es da noch eine andere Möglichkeit? Ich gehe mal davon aus, dass die Lizenz nicht automatisch erkannt und verwendet wird? Wie im angehängten Bild "usb" zu sehen ist, wird der Dongle auch als solcher erkannt.
Last updated: 2024-09-02
Post by micik on False Notification Application Error with raspberry pi 4
CODESYS Forge
talk
(Post)
Hello, I have just went through all steps shown on Codesys YT channel https://www.youtube.com/watch?v=RPoPscbo3Kc And it works, I have installed PI OS 32 bit and choose Single Core. However, immediattely when I create standard project with Raspberrz pi device, "Application" is underlined, like there is an error, but in reality there are no errors, and I cannot see what are these 3 messages like shown in attachment. Aside for this red underline, everything seems to work fine. How to correct this? Thank you! Update: I have found what errors are, but not sure how to correct them: Identifier 'IoDrvGPIO' not defined Function block 'IoDrvGPIO' must be instantiated to be accessed 'IoDrvGPIO' is no component of 'IoDrvGPIO'
Last updated: 2024-09-03
Post by dkugler on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
you can give this code snippet a try. It's extracted and simplyfied from my code: Install VisuElemBase lib if not installed yet. Execute in visu task: VAR pClientData : ARRAY [-1..100] OF POINTER TO VisuElemBase.VisuStructClientData; END_VAR VisuElemBase.g_ClientManager.BeginIteration(); pClientData := VisuElemBase.g_ClientManager.GetNextClient(); WHILE pClientData <> 0 DO pClientData[pClientData^.GlobalData.GlobalClientID] := pClientData; END_WHILE You have to make shure every no longer updated pointers in the array have to be deleted and no longer used by your code! Usage of this pointer access at your own risk :-) Works with SP16. From SP17 and newer there will be warnigs etc. using this solution as I remember. It will be great, if Codesys publishes a example or give a hint how to accesse this client values with the VisuUtil lib or other future-proof way!
Last updated: 2024-09-09
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jari-koivuluoma on Newly created texlists wont appear in the selection dropdown
CODESYS Forge
talk
(Post)
When I create a new textlist in Codesys 3.5 SP19 Patch 5, it wont appear in the dropdown menu at Rectangle element > Dynamic texts > Text list. If I just type the name of the textlist to the field (in quotes), I get an error saying that some file is missing. Any good ideas what to do and what is going on. I recently updated to that version and I only now noticed this when I needed to add a new textlist so Im quite screwed with this not being able to add text lists. While im typing this, I tried copying an existing list and modifying it and it seems to show. Any ideas?
Last updated: 2024-09-19
Post by thn-power on How to change OPC NodeId IdentifierType
CODESYS Forge
talk
(Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20
Post by danielbeers on Automation Server + Pi Gateway + PLC w/ CAN
CODESYS Forge
talk
(Post)
Hello, I have a project using some EPEC PLC's. Some of them are programmable using Ethernet and some use CAN. We currently have a Raspberry Pi that is acting as a gateway to the Codesys Automation Server and is successfully working for the PLC's communicating over ethernet. I am trying to achieve a similar result for the PLC's that have only CAN access. I have PEAKCan drivers on the Pi, and can successfully send/receive messages. But the Gateway does not recognise the PLC when scanned from the Automation server online. Is there a library or service that exists to translate the CAN messaging, to the Edge Gateway, and be able to achieve remote access with the Automation Server? Or is this not possible without creating something custom? Cheers, Daniel
Last updated: 2024-09-22
Post by timvh on Clarifications regarding the appropriate runtime system to use
CODESYS Forge
talk
(Post)
If you are not using any specific Raspberry Pi functionality, then probably the "universal" Control Linux ARM SL is the approriate runtime to run on the Pi. For the license it doesn't matter which runtime version you choose, because this is not hardware based anymore, but application based. Best is to use the latest version of CODESYS. To determine which license you need, double click on your device, go to the tab License metrics.... Generate the code for your application and see which license you need based on the metrics of your application.
Last updated: 2024-09-24
Post by timvh on Visuutils FbOpenDialog(Extended) not open Dialog from POUs
CODESYS Forge
talk
(Post)
I had a similar situation recently where this didn't work, but read to the end to see the solution. The reason is that CODESYS only downloads visualisations (dialogs) if they are part of the project or linked to the project. In your case the dialog is not loaded onto the controller. But the solution is pretty simple: Double click on the Visualization Manager in your application. Select the Tab "Visualizations". Here you can see that your dialog is not "checked". Do this manually and load your project on the controller. Then your code should be able to open the dialog, because now it exists on the controller.
Last updated: 2024-09-28
Post by timvh on FB string and naming
CODESYS Forge
talk
(Post)
I see, you want to initialize the FB. To be able to initialise it like you described, you need to add the FB_Init method to your FB. (right click on the FB, select add object --> method). Then press the arrow down, to select the FB_Init (overwrite default implementation). In the VAR_INPUT section of this method, add the variable --> Tag : STRING; Then in the code section of this method add: THIS^.Tag := Tag; // copy initial value to local variable in FB Search Google if you want to know more about FB_Init. PS, reflection + instance path, is also an option if you want to get the full name of the instance (path) of the Function Block. See: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_instance_path.html
Last updated: 2024-09-30
Post by pernockham on Linking to IO during runtime with hot swap?
CODESYS Forge
talk
(Post)
I have a project where a single PLC shall control multiple nodes (up to 10 units?) with IO connected through profinet. Ideally each node should be identical however with time I see situations were different setups/configurations will be used. Codesys PLC (GVLs) |Profinet | |--PNIO-node-1--| | | AIO, | | DIO, | | CNT etc. | |--PNIO-node-2--| | | AIO, | | DIO, | | CNT etc. Ideally I think of a configuration through yaml/xml-files (the assignment/linking of the profinet nodes towards GVL-variables in the PLC as well as scaling, channel configration etc.). Would be grateful if someone could suggest library/-ies that can handle the following: - Verify what IO is connected to a device/node. - Hot-swap/assign link for IO towards GVLs, either automatically or through a HMI.
Last updated: 2024-10-11
Post by timvh on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
RS485 doesn't seem very logical to use in VPLC's in my opinion. I also don't know if this is supported.... But for TCP/IP, I think you still need to configure the Nic settings. See the attached png. In my case enp6s0. When changing this setting, restart the VPLC. What is really nice, is that you don't have to configure the IP address setting in Linux. By setting the Nic to a certain IP address in the CODESYS instance configuration, this is automatically done for you. I only tested this with EtherCAT, but I guess this works the same for Modbus TCP/IP.
Last updated: 2024-10-23
Post by struccc on HTML5 Controls - string(>80) values
CODESYS Forge
talk
(Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23
Post by gediminas on Datasource OPC UA client system failure
CODESYS Forge
talk
(Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25
Post by phoward131 on Alarm Table Filtering
CODESYS Forge
talk
(Post)
I am having trouble getting the alarm table filtering to work. I downloaded the alarm filter latch example project and ran it on the local Codesys Control Win and the filters worked fine. I am trying to replicate it in my project and everything seems to be set up the exact same way and every time I turn on the filter, it shows no alarms. I even started a blank project and just copied in elements from the example project so that it is exactly the same and when I attempt to filter, it again shows no alarms. Could there be some project settings I need to adjust to make this work? I have attached my project with elements copied from the example project and filtering is not working.
Last updated: 2024-10-28