Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26
Post by jbcregen on Accessing parameters from a structure or function block with the web interface
CODESYS Forge
talk
(Post)
I have a project with hundreds of OPC-UA variables available on the network. A lot of these variables are used actively in various scripts that run in background in the OS (Linux). I'm experimenting with Automation Server and I have a hard time understanding how the web interface populates its parameters list for a given PLC (<plc details="" parameters="" for="" plc="" 'xyz'="">).</plc> In this page, it looks like the only variables available are the ones that are of a "base" type : bool, TIME, String, INT, etc. All the variables that are nested into function blocks or structures are not available in the web interface, even if they are available to any OPC-UA client. Is this a limitation of the Automation Server or is there something that can be done in Codesys?
Last updated: 2025-12-01
Post by jasperclauwaert on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS)
CODESYS Forge
talk
(Post)
Hi everyone, I’m working on a WAGO PFC100 with CODESYS. During development everything worked fine, but in the final stage I set several variables to PERSISTENT RETAIN. When I go online, most of these persistent variables cannot be monitored. Instead, I see: <Value of the expression cannot be retrieved> Interestingly, a few variables do show their values correctly, but the majority do not. The variables are not used as pointers or in any unusual way. The application compiles and runs without errors. Has anyone experienced this before? Is this a known issue with PFC100 or CODESYS? Any ideas on what could cause this behavior? Thanks in advance! Jasper
Last updated: 2025-10-23
Post by jasperclauwaert on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS)
CODESYS Forge
talk
(Post)
Hi everyone, I’m working on a WAGO PFC100 with CODESYS. During development everything worked fine, but in the final stage I set several variables to PERSISTENT RETAIN. When I go online, most of these persistent variables cannot be monitored. Instead, I see: <Value of the expression cannot be retrieved> Interestingly, a few variables do show their values correctly, but the majority do not. The variables are not used as pointers or in any unusual way. The application compiles and runs without errors. Has anyone experienced this before? Is this a known issue with PFC100 or CODESYS? Any ideas on what could cause this behavior? Thanks in advance! Jasper
Last updated: 2025-10-23
Post by marek71 on Ambiguous use of name - CO136
CODESYS Forge
talk
(Post)
My PLC is WAGO PFC200 Firmware Revision 26. target After updating WAGO_Devices_and_Libraries with newer Firmware 27, CODESYS wants to update all libraries to new versions. I will only add that I did not update the Firmware in the PLC. After compiling the program, I received the following errors: ------ Build started: Application: Device.Application ------- Typify code... [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): FbSerialInterface_internal: C0136: Ambiguous use of name 'RTS_IEC_RESULT' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0032: Cannot convert type 'Unknown type: 'RTS_INVALID_HANDLE'' to type 'POINTER TO BYTE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0136: Ambiguous use of name 'RTS_INVALID_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): Initialize [FbSerialInterface_internal]: C0046: Identifier 'RTS_INVALID_HANDLE' not defined [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_tx_empty: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_get_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_is_line_available: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): COMSW_SET_MODE: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' [ERROR] wagosyscom_internal_pfc, 1.0.2.5 (wago): comextra_set_line_state: C0136: Ambiguous use of name 'RTS_IEC_HANDLE' Compile complete -- 10 errors, 0 warnings Build complete -- 10 errors, 0 warnings : No download possible The problem was caused by the WagoSysPlainMem(WAGO) library in the original version 1.5.3.0 after updating to 1.5.3.1. After returning to version 1.5.3.0, the problems disappeared. Probably the version number of this library is responsible for supporting the appropriate Firmware Revision. Can anyone confirm or deny my suspicions?
Last updated: 2024-07-06
Post by abauza on Image Pool using in other libraries
CODESYS Forge
talk
(Post)
Hi im Albert, im developing libraries for my PLCs and i have some issues on visualization part. First of all I have done a library that have a image pool with a list of 4 gifs "ImagePoolErrors" (i've tested in other projects and it works) but the problem comes when i create another library that in the visualization part contains images from my image pool library, when i simulate a program that includes a instance of my second library object the visualization images dont show, any of them, i've checked all the references and tried some options of the image properties but without any difference. Here is the screenshots of the first library (that contains Image Pool) and the second library (that includes images of the image pool first library) and the visualization simulation (with the missing image gif issue). Any idea of what i forgotten in the process? If you need any detail of the library or of the project or you need the library file, ask me, thank on advance
Last updated: 2024-08-19
Post by dkugler on Visualisierung wechseln über SPS Variable Codesys 3.5
CODESYS Forge
talk
(Post)
Abgeschaltet? Wie wäre es auf codesys.com -> Menü Button oben rechts -> Support -> Online Hilfe: die Zwei Wörter "current visu" einzutippen? -.-
Last updated: 2024-08-26
Post by ph0010421 on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
My guess is that's a STRING, not an INT type. And it's 128 bytes, not bits
Last updated: 2024-09-23
Post by opineiro on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
Thanks, I'm going to try it!
Last updated: 2024-09-23
Post by arwie on Eoe issues with Windows and Linux
CODESYS Forge
talk
(Post)
You can select the tap name with this environment variable: RTS_EOE_DEV=tap3
Last updated: 2024-10-07
Post by damian177 on url String notation
CODESYS Forge
talk
(Post)
Hi, How to initialize following url: https://mydomain.pl/api/rce-lte?$filter=doba eq '2025-03-18' in sURL : STRING variable ? regards
Last updated: 2025-04-04
Post by hteich on Date and time to String variable
CODESYS Forge
talk
(Post)
Did you find out how to do it? The link posted by lukas didn't help me much further
Last updated: 2025-10-07
Post by goki on Problem mit String in Globaler Variable
CODESYS Forge
talk
(Post)
Hallo Zusammen Gibt es ein Beispiel wie ich dies so im Codesys 3.5 umsetzen kann?
Last updated: 2024-02-09
Post by nmcc on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
Here is a screenshot. I really do not know how to format the variable exchange you are talking about.
Last updated: 2024-02-13
Post by nmcc on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
Here is a screenshot. I really do not know how to format the variable exchange you are talking about.
Last updated: 2024-02-13
Post by bouadel on Trend recording build error - the variable "arrTraceMgrVariablesImpl" is too large
CODESYS Forge
talk
(Post)
Hello do you find a solution ? I have the same Kind regards Adel
Last updated: 2024-04-09
Post by enricoghisla on Functional block
CODESYS Forge
talk
(Post)
How can i access to the variable in the FB from outside without put them in the in/out?
Last updated: 2024-04-16
Post by enricoghisla on Functional block
CODESYS Forge
talk
(Post)
How can i access to the variable in the FB from outside without put them in the in/out?
Last updated: 2024-04-16
Post by automa on How to write variable by name
CODESYS Forge
talk
(Post)
It has been a few years since this topic. Any solutions?
Last updated: 2024-06-04
Post by nano on Persistent variable storage
CODESYS Forge
talk
(Post)
use the persistence manager. with the persistence-manager, you're aböe to define how, when and where you store your data
Last updated: 2024-06-16
Post by rabaggett on No Visu on RasPi
CODESYS Forge
talk
(Post)
OK, I got this to work as shown above in mos89p's comment. What I did: Tools/Update Raspberry Pi. Reloading the runtime seems to have solved the web problem. I can view the visualization on the Pi and laptop using a browser as shown above. Thanks! But Isn't the visualization supposed to take over the screen of the Raspi? When I run visu projects on Windows or Wago, the visualization shows on that device's screen by default.. But this is not happening in this case
Last updated: 2024-06-20
Post by fless on No source code available for profinet library
CODESYS Forge
talk
(Post)
looks like you are running in a bug in the newest version 4.4.0 of the profinet library or the new library triggers a bug in your code. did you update your profinet device too? you could try to downgrade to an older version of the library. via library manager - placeholders, double click Profinet 4.4.0 in the library column and choose an older version.
Last updated: 2023-08-23
Post by rickj on Defining local variables that can be independent with several users.
CODESYS Forge
talk
(Post)
You need to create an array with one element for each possible user. I usually define these arrays in the root screen. FrameIndex : Array [0..MaxUsers] OF INT; Then use the global CurrentClientId (defined by one of the VISU libraries) to index the array element used to select the frame. FrameIndex[CurrentClientId]
Last updated: 2023-10-21
Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port
CODESYS Forge
talk
(Post)
I've also noticed that when I turn off "enp1s0", suddenly the source IP for the ModbusTCP changes to that of "enp2s0", which is what makes sense to me. When I turn it back on, the source IP remains that of "enp2s0".
Last updated: 2024-08-01
Post by abauza on Image Pool using in other libraries
CODESYS Forge
talk
(Post)
Hi I have done some tests and i realised that it's an issue with the visualizator simulator because i uploaded the program to a device and tried to see on the Web browser and I see correcctlu the images of the image pool of the library. I post this for anyone that have the same problem.
Last updated: 2024-08-20
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.