Codesys auf einen Cortex M4 lauffähig machen
CODESYS Forge
talk
(Thread)
Codesys auf einen Cortex M4 lauffähig machen
Last updated: 2024-01-04
Post by tvm on multiply gives negatives
CODESYS Forge
talk
(Post)
It's probably because you have an INT in the input to the MUL function, which will then try to output an INT as well. INT variables can only handle values of -32768 to 32767. Your value of 523000 won't fit in an INT, so it turns into an invalid number. Use a DINT. This is usually better for working with time values anyway, because time values are all 32 bit. Or if you can't, use INT_TO_DINT(gvlp.detectie_nalooptijd_s) in the input to the MUL function.
Last updated: 2024-01-04
Post by tvm on Function block method default arguments
CODESYS Forge
talk
(Post)
This works for me in Schneider Machine Expert 2.2, which is based on Codesys 3.5.19. It did not work in Machine Expert 2.1, which was based on Codesys 3.5.16. METHOD PUBLIC Method1 : INT VAR_INPUT TestVar: INT:= 5; END_VAR Method1:= TestVar; PROGRAM SR_Main VAR TestFB: TEST_FB; Var1: INT; END_VAR Var1:= TestFB.Method1();
Last updated: 2024-01-04
multiply gives negatives
CODESYS Forge
talk
(Thread)
multiply gives negatives
Last updated: 2024-01-04
Post by tvm on multiply gives negatives
CODESYS Forge
talk
(Post)
you might have some slight inaccuracies with using a REAL. See here for an explanation: https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z0000019ZSMSA2&l=en-US It might not matter, depends on how accurate you need it. I usually stick with integer types for something like this
Last updated: 2024-01-04
Post by domoticom on multiply gives negatives
CODESYS Forge
talk
(Post)
thnx, meanwhile I added a INT_TO_REAL, now it works. Can I leave it like this or better DINT ?
Last updated: 2024-01-04
Post by atone on File Creation Issue
CODESYS Forge
talk
(Post)
Found it! Set ForceIecFilePath to 0 in CODESYSControl.cfg
Last updated: 2024-01-04
Post by joanm on Function block method default arguments
CODESYS Forge
talk
(Post)
The new TwinCAT 4026 will add those default parameters, as TwinCAT drinks from Codesys I guess that will be implemented soon (or maybe, it already is given what tvm says in the previous post).
Last updated: 2024-01-04
Function block method default arguments
CODESYS Forge
talk
(Thread)
Function block method default arguments
Last updated: 2024-01-04
Post by jmohre on External file with relative path
CODESYS Forge
talk
(Post)
I try to add a simple text file to my PLC application, so that is download everytime the application is downloaded to the target. What I did is to add an external file to the application and this works perfect as long as the external file location does not change. It looks like the external file path is stored absolute in project. But if different users work on the project they may have different locations where for their working directory. Is there an option to store the external file path relative e.g. to the project file? Or does s.o. know a different solution to add a text file to application in order to download automatically with the application? Thanks
Last updated: 2024-01-04
Post by pmasip on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
So none of the images from the 64bit archive work with any Codesys Control versions? I have tried the last Pi OS with every Codesys Control version and they don't work. I was wondering if there's any stable combination of versions.
Last updated: 2024-01-04
Raspberry Pi
CODESYS Forge
talk
(Thread)
Raspberry Pi
Last updated: 2024-01-04
Post by ahessel on Raspberry Pi
CODESYS Forge
talk
(Post)
Hello Mr. Schwellinger, why is there no release note at a central point with such incompatibilities? I also wasted a whole day until I found this thread by chance. best regards Andreas
Last updated: 2024-01-04
Post by vformanek on irq-set piority is not working in plc-shell
CODESYS Forge
talk
(Post)
Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html But the irq-set is not changing the priority. See the image bellow....
Last updated: 2024-01-05
System Date and Time Function
CODESYS Forge
talk
(Thread)
System Date and Time Function
Last updated: 2024-01-05
Post by atone on System Date and Time Function
CODESYS Forge
talk
(Post)
SysTimeRtcConvertUtcToLocal is marked as obsolete, but there's not hint on the actual implementation. Which function should I use instead? Edit: even the new online help is still using SysTimeRtcConvertUtcToLocal as example...
Last updated: 2024-01-05
unable to access .py library
CODESYS Forge
talk
(Thread)
unable to access .py library
Last updated: 2024-01-05
Post by shubh on unable to access .py library
CODESYS Forge
talk
(Post)
i am trying to import .py libraries of Utest in codesys environment, i have tried sys.path.append() still i am unable to access that library.
Last updated: 2024-01-05
Post by anderson on function block output
CODESYS Forge
talk
(Post)
I'm trying to make a CNC machine, but I'm having problems because the drive I'm using only has the option of communicating through digital inputs. In this case, I should use the CLP's digital outputs to communicate with it, correct? However, in the function blocks it seems that they are already pre-programmed and I didn't find the pulse output options, for example, so that I could associate a digital output from the PLC to connect this to the drive's pulse input. My question is: is it possible to associate the pulse output of the function block with a digital output of the PLC? and how to do this?
Last updated: 2024-01-05
Post by spiessli on Softmotion axis to CANopen Maxon IDX drive
CODESYS Forge
talk
(Post)
Hi, I want to use Maxon IDX drives for some simple robotic applications. I have used Maxon's Epos for generating a DCF file to import in Codesys (attached). Then I can add the IDX motors under a CANopen manager in the device tree. Unfortunately, I cannot add a "softmotion axis" to the IDX motors. Now I am wondering, why? Without being able to attach a softmotion axis to the device in the device tree, the use of the motor is greatly reduced... spiessli
Last updated: 2024-01-05
Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
Hello, according to Codesys, the problem should be solved with version 4.3.0.0. After the update to version 4.3.0.0 I had the problem that the recipes weren’t saved correctly, but loading was okay. Return to the version 4.2.0.0 didn’t change the behavior. Strange… So I uninstalled the update, cleaned the project and built it new. The known behavior of version 4.2.0.0 was back. Update to version 4.3.0.0, clean and build it new, it works. Even with version 4.2.0.0. Strange, but okay. Notice: ManCommands.LoadRecipe() no longer writes into the PLC. Just as it should be. As of now, I can use the new version.
Last updated: 2024-01-05
Post by eschwellinger on function block output
CODESYS Forge
talk
(Post)
I think you should use a piece of hardware in between your drive (pulse/direction) and the plc like for example Beckhoff EL2521 - so Ethercat might be to choice if you need CNC and SoftMotion. EK1100 and EL2521
Last updated: 2024-01-05
Post by eschwellinger on irq-set piority is not working in plc-shell
CODESYS Forge
talk
(Post)
example: use the following in the plcshell: irq-set-prio eth0 55
Last updated: 2024-01-05
irq-set piority is not working in plc-shell
CODESYS Forge
talk
(Thread)
irq-set piority is not working in plc-shell
Last updated: 2024-01-05
Post by reinier-geers on Add licence
CODESYS Forge
talk
(Post)
Ive got the license dongle. But hey cant see it. When i put in a stick the contoller detects the stick. When i stick the dongle it doesnt detect. So 2 options from codesys who doesnt work
Last updated: 2024-01-05