Search talk: check object is null

 
<< < 1 .. 77 78 79 80 81 .. 135 > >> (Page 79 of 135)

Post by andrej on Write to File on soft PLC winV3x64 CODESYS Forge talk (Post)
Hello all, I would like to store some data in text file. I use the soft PLC Win V3x64, on Windows 10. I use the SysFile Library 3.5.17.0. If I store the file directly in the in the directory of the PLC i.e. in '/CODESYSControlWinV3x64/E1FA7ABE/PlcLogic/LogAU.txt' the file is correctly filled with the data. However, If I use an absolute path to a different directory no data is stored in the respective file. Despite the fact that the respective file exists and the Filehandler is correctly opened (see in picture _fdSysFHandle <> -1). // sFileName : STRING := 'LogAU.txt'; // STORES FILE IN ../CODESYSControlWinV3x64/../PlcLogic/LogAU.txt' sFileName : STRING := 'C/Temp/LogAU.txt'// DOES NOT WORK --------------------- // FILE DESCRIPTOR _fdSysFHandle := SysFile.SysFileOpen( szFile:= sFileName,am:= SysFile.AM_APPEND,pResult := ADR(_Result)); Does some have an idea where the problem is, resp. how I can get store a file in an arbitrary directory. Thanks a lot and kind regards Andreas
Last updated: 2023-10-24

Post by janber0206 on RPI is license server down CODESYS Forge talk (Post)
I had the same problem. Problem solved: all licences purchased before October 2022 must be updated by Codesys. To do so, simply contact the support in the Codesys Store.
Last updated: 2023-10-30

Post by necatibilgin on Communication betwee 2 codesys devices with PROFINET CODESYS Forge talk (Post)
Hi everybody, Is there any sample project that communicates 2 devices with profinet using Codesys platform on the devices? BR, Necati.
Last updated: 2023-11-03

Post by gurke258 on Codesys Safety EtherCAT with Beckhoff CODESYS Forge talk (Post)
Okay, the solution was so simple... In my case, you first have to add the EL1918 and then the EL2904... then the connection is made automatically. I probably had something else before and then added the EL1918... then it doesn't catch the connection :/
Last updated: 2023-11-08

Post by snhatton on How to switch between dynamic IP address and dynamic? CODESYS Forge talk (Post)
Does this help: https://pimylifeup.com/raspberry-pi-static-ip-address/#:~:text=1%20To%20begin%20setting%20up%20a%20static%20IP,go%20ahead%20and%20restart%20the%20Raspberry%20Pi.%20. Following those instructions, it is possible to configure the ip address as static.
Last updated: 2023-11-08

Post by davidbo on How to switch between dynamic IP address and dynamic? CODESYS Forge talk (Post)
Well. One can do that, I have found a python script which can modify /etc/dhcpcd.conf and I suppose there is a way I can execute it from CODESYS and it seems to be the only way
Last updated: 2023-11-08

Post by oazrad on Async Manager CODESYS Forge talk (Post)
anyone found any sample code for this library? I'm trying to work with AsyncManager but the documentation is not helping? Surly, codesys when they coded this library they had a sample project to test and simulate the functionality for this library. can you share it please ?
Last updated: 2023-11-15

Post by baldeep on Codesys Raspberry Runtime 4.10.0.0 and RSM Utility 3.5.19.0 CODESYS Forge talk (Post)
I had been using Codesys Raspberry 4.9.0.0 Runtime for a Project with CAA File 3.5.19.0. But now with Update 4.10.0.0 and Raspberry pi 64 Bit.....i cannot compile my code as RSM Utility 3.5.19.0 is not recognised. Any help? Regards
Last updated: 2023-11-20

Post by annd on Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2" CODESYS Forge talk (Post)
@pflot59: Thanks, I know this guide but there a slight differences in migrating from eCockpit or from Codesys SL. It is still fine as I wrote above. BR annD
Last updated: 2023-11-23

Post by srigan1986 on SP8 - New scriptengine feature - open:VersionUpdateFlags CODESYS Forge talk (Post)
Is this issue of idling before loading libraries resolved in Codesys 3.5.18.40 ? I am also curious about this version as there seem to be huge difference in the compiler versions which don't recognize the versions with older storage format.
Last updated: 2023-11-24

Post by nathant on Easiest RevPi PLC to configure HMI visualization with? CODESYS Forge talk (Post)
I'm worried that the Core SE (which I was originally going to go with) will not be straight foward in terms of setting up the HMI visualization. This is for an offline application, if that matters.
Last updated: 2023-11-28

Post by nathant on Easiest RevPi PLC to configure HMI visualization with? CODESYS Forge talk (Post)
I'm worried that the Core SE (which I was originally going to go with) will not be straightfoward in terms of setting up the HMI visualization. This is for an offline application, if that matters.
Last updated: 2023-11-28

Post by shabroz-gill on Unable to load boot application on ARMv7 device restart CODESYS Forge talk (Post)
The boot application already exists on the device, i can see the MPC.app file in the proper place. It is not able to load it on startup though
Last updated: 2023-12-01

Post by nizrahel on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
Hi all! I'm working on an home project using a Raspberry Pi 3 device with Codesys for Raspberry Pi 64 SL runtime. I would like to create the HMI interface with Siemens WinCC Unified (or Advanced) configuring the Raspberry as OPC UA server. I tryed everything, but I didn't find the way to let the OPC UA connection works using UaExpert. I tryed to use anonymous connection, authenticated connection and the ip address instead of the server name in the path connection. There is no way to connect to the OPC UA server and I was asking myself if this feature is really supported for the runtime version used. Another strange thing I noted, is that is not possible to quickly create an OPC UA certificate in the Security Screen, as show in any tutorials. I have correctly created the Symbol Configuration enabling the OPC UA feature. I attach to this topic some printscreen of the actual configuration (sorry for the italian language interface, but I didn't find the way to switch to english). Thank you very much in advance for your support and advices!
Last updated: 2023-12-03

Post by user3000 on Can't find an Extended Pulse Timer (TP and LTP) CODESYS Forge talk (Post)
Hello, For my program I need an extended pulse timer, which can be referred to as a retriggerable pulse timer. Where every rising edge of the input resets the elapsed time zero, extending the lenght of the output pulse. The Codesys pulse timer (TP) is a one-shot timer and only resets the elapsed time with the falling edge of the input. There is also a pulse timer (LTP) in codesys, but in my simulation it was also functioning as a one-shot even though the description sounds like LTP should be retriggerable. I have uploaded some timing plots from another PLC program for reference. I am looking for a timer equivalent to the "TEP" diagram. Is there an Extended Pulse Timer in Codesys? Maybe there is a way to manipulate the input so it resets the elapsed time outside the function block?
Last updated: 2023-12-06

Post by voffi on CODESYS Custom Build Step CODESYS Forge talk (Post)
Good morning! Is there a way to run a python script or something else automatically after CODESYS (3.5) did its build or before download? I am searching for something like the Custom Build steps in Visual Studio. Thank you! Voffi
Last updated: 2023-12-07

Post by thn-power on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi, Did you manage to solve the problem? I'm experiencing the same thing using a exported nodeset from UaModeler.
Last updated: 2024-06-28

Post by hwopereis on How to use Application Trigger in Modbus TCP Server CODESYS Forge talk (Post)
I'm now circumventing the problem by creating a separate TCP client for all Write actions. Upon registering a changed variable, I enable this client, until the change is processed.
Last updated: 2024-07-01

Post by psychoengineer on Trouble Writing Files to External Paths in CODESYS CODESYS Forge talk (Post)
Hi! Do you know how to properly configure SysFile for COdesys Control Win64? Where is it that file on the PC disk and whatr to add?
Last updated: 2024-07-05

Post by psychoengineer on Trouble Writing Files to External Paths in CODESYS CODESYS Forge talk (Post)
Hi! Do you know how to properly configure SysFile for COdesys Control Win64? Where is it that file on the PC disk and what to add?
Last updated: 2024-07-05

Post by psychoengineer on Trouble Writing Files to External Paths in CODESYS CODESYS Forge talk (Post)
Hi! Do you know how to properly configure SysFile for COdesys Control Win64? Where is it that file on the PC disk and what to add?
Last updated: 2024-07-05

Post by strannik on SoftMotion SML CODESYS Forge talk (Post)
I use SoftMotion Light libraries in my CodeSys 3.5 project. Activated the license. But probably not all the actions were completed. In the configuration of the axes A message that the driver is running in demo mode. Please tell me what complete actions need to be performed. Thanks
Last updated: 2024-07-06

Post by disha on Export data with the Trend API CODESYS Forge talk (Post)
Can you please share the code as i am the beginner for codesys. I don't have any idea that how sqlite is integrated with the codesys.
Last updated: 2024-07-08

Post by akos on Soft motion kinematic zones CODESYS Forge talk (Post)
Hello Everyone, Is there any solution to define safety/forbidden zones in the coordinate system of the kinematics? Its not enough, to define only limits in my servo axes! I need zones in 3D! :) Thanks for the help!
Last updated: 2024-07-10

Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs CODESYS Forge talk (Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11

<< < 1 .. 77 78 79 80 81 .. 135 > >> (Page 79 of 135)

Showing results of 3370

Sort by relevance or date