Search talk: -128到127是什么数据类型

 
<< < 1 .. 779 780 781 782 783 .. 888 > >> (Page 781 of 888)

Post by tvm on SEND_RECV_MSG function block on Schneider Machine Expert CODESYS Forge talk (Post)
Anyone else using the SEND_RECV_MSG function block for RS-485 communication on Schneider Machine Expert? I have had ongoing issues with it for several years, which Schneider tech support is aware of, but hasn't been able to fix. The latest version of Machine Expert (v2.2) appears to have broken some of the functionality altogether. I'd be interested in hearing from anyone else using this platform for serial communication.
Last updated: 2024-01-03

Post by joanm on Programmatically change the IP addresses of the Modbus TCP slave devices CODESYS Forge talk (Post)
Hello all, I am working in a project in which there are multiple Modbus TCP slaves. I need to be able to change the IP addresses of those devices from the HMI and I was planning to use the process depicted here: https://faq.codesys.com/display/CDSFAQ/Modbus+TCP+Slave%3A+Dynamic+Setting+of+the+IP+Address I can see the port number is what is used to specify which slave device we want to modify the IP address of. This said, can I freely set arbitrary port numbers to each device? I mean, can I set the first device to be at port 502, the second one at port 503... Any drawback or restriction? Is there any other way to reference to the device without having to change the port numbers? Thank you all in advance.
Last updated: 2024-01-04

Post by atone on File Creation Issue CODESYS Forge talk (Post)
@eschwellinger does FILE.Copy fails with FILE_OPERATION_DENIED when copying outside from the IEC path for the same reason? I'm looking for a workaround to this limitation.
Last updated: 2024-01-04

Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
Nice to hear that I'm not the only one. I share your suffering. I was on the verge of doing the same.
Last updated: 2024-01-04

Post by sebastian-hk on Codesys auf einen Cortex M4 lauffähig machen CODESYS Forge talk (Post)
Wichtig ist zudem auch noch zu wissen, ob der Cortex M4 Prozesser für eine Codesys Laufzeit ausreicht, oder ob es einige Einbußen gibt. Hat da jemand Praxiserfahrungen sammeln können? Wie es bei Codesys steht, wird kein Betriebssystem wie Linux oder Windows bei diesem Prozessor benötigt. Somit müsste dieser performant genug sein oder sehe ich das falsch?
Last updated: 2024-01-04

Post by domoticom on multiply gives negatives CODESYS Forge talk (Post)
Hi, Attached net gives sometimes negatives, what am I doing wrong ? PS: detectie_nalooptijd_s = INT
Last updated: 2024-01-04

Codesys auf einen Cortex M4 lauffähig machen CODESYS Forge talk (Thread)
Codesys auf einen Cortex M4 lauffähig machen
Last updated: 2024-01-04

Post by tvm on multiply gives negatives CODESYS Forge talk (Post)
It's probably because you have an INT in the input to the MUL function, which will then try to output an INT as well. INT variables can only handle values of -32768 to 32767. Your value of 523000 won't fit in an INT, so it turns into an invalid number. Use a DINT. This is usually better for working with time values anyway, because time values are all 32 bit. Or if you can't, use INT_TO_DINT(gvlp.detectie_nalooptijd_s) in the input to the MUL function.
Last updated: 2024-01-04

Post by tvm on Function block method default arguments CODESYS Forge talk (Post)
This works for me in Schneider Machine Expert 2.2, which is based on Codesys 3.5.19. It did not work in Machine Expert 2.1, which was based on Codesys 3.5.16. METHOD PUBLIC Method1 : INT VAR_INPUT TestVar: INT:= 5; END_VAR Method1:= TestVar; PROGRAM SR_Main VAR TestFB: TEST_FB; Var1: INT; END_VAR Var1:= TestFB.Method1();
Last updated: 2024-01-04

multiply gives negatives CODESYS Forge talk (Thread)
multiply gives negatives
Last updated: 2024-01-04

Post by tvm on multiply gives negatives CODESYS Forge talk (Post)
you might have some slight inaccuracies with using a REAL. See here for an explanation: https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z0000019ZSMSA2&l=en-US It might not matter, depends on how accurate you need it. I usually stick with integer types for something like this
Last updated: 2024-01-04

Post by domoticom on multiply gives negatives CODESYS Forge talk (Post)
thnx, meanwhile I added a INT_TO_REAL, now it works. Can I leave it like this or better DINT ?
Last updated: 2024-01-04

Post by atone on File Creation Issue CODESYS Forge talk (Post)
Found it! Set ForceIecFilePath to 0 in CODESYSControl.cfg
Last updated: 2024-01-04

Post by joanm on Function block method default arguments CODESYS Forge talk (Post)
The new TwinCAT 4026 will add those default parameters, as TwinCAT drinks from Codesys I guess that will be implemented soon (or maybe, it already is given what tvm says in the previous post).
Last updated: 2024-01-04

Function block method default arguments CODESYS Forge talk (Thread)
Function block method default arguments
Last updated: 2024-01-04

Post by jmohre on External file with relative path CODESYS Forge talk (Post)
I try to add a simple text file to my PLC application, so that is download everytime the application is downloaded to the target. What I did is to add an external file to the application and this works perfect as long as the external file location does not change. It looks like the external file path is stored absolute in project. But if different users work on the project they may have different locations where for their working directory. Is there an option to store the external file path relative e.g. to the project file? Or does s.o. know a different solution to add a text file to application in order to download automatically with the application? Thanks
Last updated: 2024-01-04

Post by pmasip on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05 CODESYS Forge talk (Post)
So none of the images from the 64bit archive work with any Codesys Control versions? I have tried the last Pi OS with every Codesys Control version and they don't work. I was wondering if there's any stable combination of versions.
Last updated: 2024-01-04

Raspberry Pi CODESYS Forge talk (Thread)
Raspberry Pi
Last updated: 2024-01-04

Post by ahessel on Raspberry Pi CODESYS Forge talk (Post)
Hello Mr. Schwellinger, why is there no release note at a central point with such incompatibilities? I also wasted a whole day until I found this thread by chance. best regards Andreas
Last updated: 2024-01-04

Post by vformanek on irq-set piority is not working in plc-shell CODESYS Forge talk (Post)
Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html But the irq-set is not changing the priority. See the image bellow....
Last updated: 2024-01-05

System Date and Time Function CODESYS Forge talk (Thread)
System Date and Time Function
Last updated: 2024-01-05

Post by atone on System Date and Time Function CODESYS Forge talk (Post)
SysTimeRtcConvertUtcToLocal is marked as obsolete, but there's not hint on the actual implementation. Which function should I use instead? Edit: even the new online help is still using SysTimeRtcConvertUtcToLocal as example...
Last updated: 2024-01-05

unable to access .py library CODESYS Forge talk (Thread)
unable to access .py library
Last updated: 2024-01-05

Post by shubh on unable to access .py library CODESYS Forge talk (Post)
i am trying to import .py libraries of Utest in codesys environment, i have tried sys.path.append() still i am unable to access that library.
Last updated: 2024-01-05

Post by anderson on function block output CODESYS Forge talk (Post)
I'm trying to make a CNC machine, but I'm having problems because the drive I'm using only has the option of communicating through digital inputs. In this case, I should use the CLP's digital outputs to communicate with it, correct? However, in the function blocks it seems that they are already pre-programmed and I didn't find the pulse output options, for example, so that I could associate a digital output from the PLC to connect this to the drive's pulse input. My question is: is it possible to associate the pulse output of the function block with a digital output of the PLC? and how to do this?
Last updated: 2024-01-05

<< < 1 .. 779 780 781 782 783 .. 888 > >> (Page 781 of 888)

Showing results of 22179

Sort by relevance or date