Post by bartg on Open a POU in the editor via scripting
CODESYS Forge
talk
(Post)
Hi, I would like to automate opening some specific pous and visualisations in the codesys environment I found out that I can open it by using : system.commands["42f6acb9-bd6e-42e7-94bb-6e2a03973b83"].execute() But the POU has to be selected in the Devices or POUs navigator. Does anyone know how I can select a specific POU in the navigator? Or how I can open a specific POU? I can retreive the guid of the POU. Thx
Last updated: 2024-05-30
Post by greenwood on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline
CODESYS Forge
talk
(Post)
Hallo, und vielen Dank für die Antwort. Ich habe 'Modbus_Slave_COM_Port' in eine Watchliste genommen. Leider reichen meine Kenntnisse nicht aus, um aus dem Ergebnis irgendwelche Schlüsse zu ziehen. xBusy und xError wechseln zwischen true und false (im Gegentakt), der angezeigte Fehler ist 'Response Timeout'. iChannelIndex wechselt zwischen 0 und -1. Wenn ich das richtig verstehe bedeutet das wohl, das der Servotreiber auf Anfragen einfach nicht reagiert. Ich hänge einen screenshot vom Watchfenster an, vielleicht kann jemand mehr herauslesen als ich. Nochmal danke fürs Lesen und Überlegen!
Last updated: 2024-05-31
Post by talhaali on Create an alarm list without use of Alarm config
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Create an alarm list without use of Alarm config
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by mozed on Signature verification faited fro the following package
CODESYS Forge
talk
(Post)
Good morning, I'm trying to open a project but codesys tells me that there are certain packages that I don't have and that I need to download them. Once the installation of the packages begins, it shows me a error that the signature of certain packages does not correspond to that coming from the accepted installation context. Do you have a solution to my problem please, it is very urgent in my work. Sincerely
Last updated: 2024-06-11
Post by dario99 on Error when creating a new HTML5 visualisation
CODESYS Forge
talk
(Post)
Hello, I'm quite new here. I would like to create a new HTML5 visualisation. I have already imported some templates via the visualisation elements repository, this worked fine. However, when I want to open the html5control.html in the editor or create a new project myself, I always get this error: default filesystem storage could not be found. Did you add storages.plugin to the profile? I can't find this plugin. The Package Designer (V4.1.0.0) and Codesys Visualisation (V4.5.0.0) plugins are installed Can anyone help me? Thank you very much!
Last updated: 2024-06-14
Post by dekelec on Request for IFM ecoPlus21 installation package
CODESYS Forge
talk
(Post)
Hello, I’m looking for the ecoPlus21 development environment used with early IFM controllers (e.g., CR0020_Q firmware). We have an old project created in ecoPlus21 that cannot be opened in CoDeSys 2.3, and IFM no longer provides this software. If anyone still has the ecoPlus21 installer or knows where it can be downloaded, please let me know. It’s needed only for recovery and migration of an existing project. Thanks in advance,
Last updated: 2025-10-17
Post by shaun on GAMP 5 and 21 CFR Part 11
CODESYS Forge
talk
(Post)
Good day I have been asked to do a project. It is for a pharmaceutical application and data needs to be logged. The spec calls for the control system to comply with GAMP 5 and 21 CFR Part 11. From what I can find online it's got to do with electronic records and validation. Has anyone developed any software using this or are there codesys librarys that can make my life easier in writing this code
Last updated: 2025-10-22
Post by alimans on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hi Manuknecht, Did you manage to solve the problem? I’m facing the same issue with Windows RTE SoftMotion — it works fine as long as nothing else is open in Windows, but as soon as I start another application, the EtherCAT DC time and max jitter values spike, and then all axes stop. I’ve already sent a support request to CODESYS, but haven’t received a response yet.
Last updated: 2025-10-23
Post by kenth1973 on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
My MC_Phasing FB was stuck in iPhasingState=1 and error output HIGH on one axis. I could manually overwrite the state to 0 in the instance data. During normal run I see the state change from 0 to 10 to 100 back to 0 (maybe more states that I couldnt catch with the naked eye) But - what are the states numbers and their different explenations? This is not explained in the FB guide on codesys. (the pictures show state = 0 after I reset)
Last updated: 2025-11-22
Post by antonz on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
That's what I found as well Shaun. I have seen it at least in versions 3.5.21.1 and 3.5.21.3. There seems to be an issue with the FBD/LD package v4.6.0.0. The workaround proposed by Tim works but needs to be done manually on every code change/addition. For now we manually downgrade the FBD/LD package from v4.6.0.0 down to v4.5.0.0 after installation of CoDeSys. Same as you did. I hope this gets fixed on a next patch.
Last updated: 2025-11-21
Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18
Post by jegerjon on Find index based on values
CODESYS Forge
talk
(Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20
Post by jegerjon on Find index based on values
CODESYS Forge
talk
(Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20
Post by sven01 on Documentation / Usage Help For Scripting Engine Libraries
CODESYS Forge
talk
(Post)
Hi, I am still not able to figure out how to use the the classes and their functions. 😔 Let's say I would like to use the function "importfile()" from the class "ScriptTextListObject.ScriptTextListMarker". I would be grateful for an additional example. Thanks! 😊
Last updated: 2023-08-21
Post by kunz on Profinet Device keeps abort connection with AR alarm.ind(err)
CODESYS Forge
talk
(Post)
Can somebody explain what the error Connection aborted: AR alarm.ind(err) exactly mean? I have the same Problem and dont know how to solve the issue
Last updated: 2023-08-21
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by janderson on OPC UA Server limitations, large array crashes runtime
CODESYS Forge
talk
(Post)
when using an array of structs, the runtime crashes. but when using an array of LREALS, it'll do 100k at least
Last updated: 2023-08-23
Post by eschwellinger on Connection to device closed
CODESYS Forge
talk
(Post)
is there a way to check the plclog on Opus A3 by using cmd line under Linux? This log is what you need to check for the disconnection problem
Last updated: 2023-08-24
Post by reinier-geers on Ping By Name
CODESYS Forge
talk
(Post)
How can i ping my computer by name ? My controler uses SysSockPing , But seems only by IP adres, not by name. IP adres changes. So how can i ping by name or know that im connected
Last updated: 2023-08-24
Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
check this faq section here: https://faq.codesys.com/plugins/servlet/mobile?contentId=102137886#content/view/102137886
Last updated: 2023-08-25
Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Post)
Turns out I managed to get a connection to my PLC. It seems that a few weeks ago Wago released something with version 4.3.3(25). So I reset my PLC to Factory-Reset, set it to the 192.168.1.17 IP and changed the IP to the one I wanted with the Wago EthernetSettings tool. Then updated the latest firmware using the WAGOupload tool. Now the PLC came back up without a PLC runtime running, so in the Web-tool I wen't to the "Configuration"/"PLC Runtime" and selected the runtime version "CODESYS V3". I uninstalled all Codesys versions and installed the version from the download package of Wago together with all the packages the bundle provided. After creating a new project I didn't select the old PFC200 runtime, but one of the dozens of new device profiles, that it now listed. With these settings I was then able to connect to my PLC. Now I hope I'll get the existing project that I had ported to this new structure. Sorry for the noise. Chris
Last updated: 2023-08-26
Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
Hi Rossano, thank you for the feedback, you are right this need to be changed in the faq section. Regards Edwin
Last updated: 2023-08-28
Post by reinier-geers on Ping By Name
CODESYS Forge
talk
(Post)
To bad. Controller uses Version 9.2 But i dont see a lower version of net bas Service. Maybe i can try a linux command.
Last updated: 2023-08-29
Post by eschwellinger on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
this is a security issue not to read/write in the plc allowed path I would recommend to update and change the path in the application were the files are😏
Last updated: 2023-08-30