Post by patrik on windows runtime crashes. CODESYS Forge talk (Post)
Faulting application name: CODESYSControlService.exe, version: 3.5.20.30, time stamp: 0x66ebc91d Faulting module name: unknown, version: 0.0.0.0, time stamp: 0x00000000 Exception code: 0xc0000005 Fault offset: 0x0000028010670e31 Faulting process id: 0x0x1F50 Faulting application start time: 0x0x1DB1BA284347B9C Faulting application path: C:\Program Files\CODESYS 3.5.20.30\GatewayPLC\CODESYSControlService.exe Faulting module path: unknown Report Id: d3ac6a03-667a-4d61-ab36-d2ae703fc252 Faulting package full name: Faulting package-relative application ID: My runtime crashes from time to time. I'm not getting anything in the PLC logs. This is from the windows logs. Can anyone help me understand why this is happening?
Last updated: 2025-03-19

Post by agentcousto on (no subject) CODESYS Forge talk (Post)
Hello, I have developed a Python script that I run to import XML files into my project. For this, I use the Python function import_xml(). Everything was working fine when I was using Codesys platform plugins version 2.6.1.2320, but since I upgraded to versions 2.7 and even 2.8, some files are no longer imported correctly. After some research, I identified that all the files containing variables of the type "POINTER TO" are affected. I have attached a screenshot of the error I am encountering. Do you know about this bug? Do you plan to fix it?
Last updated: 2025-03-26

Post by kuegerls on OpC UA server on Raspberry Pi MC SL - Certificate Issue CODESYS Forge talk (Post)
Hello, I have set up an OPC UA server following several guides, including this one: https://revolutionpi.com/documentation/tutorials/opc-ua-codesys-nodered/. The license for the runtime is installed on the device. However, I am unable to create a certificate for the OPC UA server in the security screen. I always get the error message: "The certificate has not been created by the device." Does anyone have an idea what might be causing this issue? Any help would be greatly appreciated! Thanks in advance! Best regards, Stefan
Last updated: 2025-04-02

Post by jampid on Codesys Codebase Library Update CODESYS Forge talk (Post)
Bonjour DIEGORAMONM, très recemment,je pense avoir résolu un problème similaire en allant dans le Placeholder (Espace réservé) du Gestionnaire de bibliothèque. Dans cette nouvelle fenêtre, je sélectionne la bibliothèque qui pose problème, et dans la colonne du milieu je clic pour définir une bibliothèque de version inférieure. à la compilation, je suis passé de 484 erreurs à 0. :) J'espère que ce sera également le cas pour toi. Bon développement JM
Last updated: 2025-04-04

Post by jampid on Codesys Codebase Library Update CODESYS Forge talk (Post)
Bonjour Diegoramonm, Je pense avoir eu un problème similaire. Je l'ai résolu en dégradant la version de la bibliothèque qui me posait problème après également une mise à jour. Ouvrir le gestionnaire de bibliothèque / Ouvrir l'onglet Espace réservé / La fenêtre Placeholders s'ouvre. Sélectionner la bibliothèque voulue puis double cliquer sur la bibliothèque(carré jaune)concernée et choisir une autre version. puis recompiler. Pour moi cela a marché du 1er coup : chance! Bon développment!
Last updated: 2025-04-07

Post by imdatatas on Import from XML problem CODESYS Forge talk (Post)
Hello Everyone, When I try to import some POUs that were previously exported from another project as an XML file, I get an error like in attached image and the process does not complete. "There are no objects in the export file..." I am using SP21 Codesys IDE and I do not know which version this XML (*.export) file was previously exported with. Has anyone encountered the same problem? Regards, imdatatas
Last updated: 2025-04-26

Post by gabrielarffa on Modbus TCP/IP having problems with global variables CODESYS Forge talk (Post)
I'm using Modbus TCP/IP to communicate Codesys with Elipse E3 as the master for a college project. I have made a list of global variables to organize the programming in two different POUs. The problem is, when I try to do the mapping of variables, the program informs me of an error due to the identifiers having a "." on their names. Do I have to reorganize my code to make it an unified block or is there a way to declare their names without changing all the code structure?
Last updated: 2025-05-20

Post by gabrielarffa on Modbus TCP/IP having problems with global variables CODESYS Forge talk (Post)
I'm using Modbus TCP/IP to communicate Codesys with Elipse E3 as the master for a college project. I have made a list of global variables to organize the programming in two different POUs. The problem is, when I try to do the mapping of variables, the program informs me of an error due to the identifiers having a "." on their names. Do I have to reorganize my code to make it an unified block or is there a way to declare their names without changing all the code structure?
Last updated: 2025-05-20

Post by wbj0t on Update project from SP20 to SP21 CODESYS Forge talk (Post)
Hello everyone. I have a problem: I installed new version of codesys IDE. When I try open project in this new version, I have many errors about Visu: rectalnge/button/frame/etc does not exist. How update properly project? 20+ pages of visu pages from 100+ frames and all visu elems looks like "Error image". It is not problem of SP20->SP21. Any update has problems from visu side.
Last updated: 2025-06-09

Post by berkdan on SMC_ReadNCFile2 is always busy CODESYS Forge talk (Post)
Hello, I’m using CODESYS V3.5 SP18. When I try to use SMC_ReadNCFile2 to read the file /PlcLogic/gcode.nc, the function block's bBusy output remains TRUE indefinitely. Can you help me understand what I might be doing wrong? Here is how I’m calling the function block. The value of strFileName is 'gcode.nc'. fbReadFile( bExecute := bExecute, sFileName := strFileName, bAbort := bCycleStop, fDefaultVel := RetainVariables.xSlowVelocity, fDefaultAccel := RetainVariables.xAcc, fDefaultDecel := RetainVariables.xDec, b3DMode := TRUE, bParenthesesAsComments := TRUE, fDefaultVelFF := RetainVariables.xFastVelocity, fDefaultAccelFF := RetainVariables.xAcc, fDefaultDecelFF := RetainVariables.xDec, ErrorID => gCNC.eErrorId, errorPos => gCNC.eErrorPos, ErrorProgramName => gCNC.eErrorProgName, bBusy => bReadFileBusy, sentences => sentencesss ); Thanks in advance for your help.
Last updated: 2025-06-16

Post by hickan on safety cpu cannot go online CODESYS Forge talk (Post)
Hi! I am using abb ac500 in automation builder v2.7 I have a problem with a new project. In the normal mode I have no problems, but in safety mode i cannot go online. I get 'Communication Error (#0) Logout Performed' message. I have tried changing the adress (level 1) in communication parameters. I tried 0.0.0.0.0 and 0.1.0.0.0 and 1.1.0.0.0 but it did no difference. What do you think could be causing this? Thanks!
Last updated: 2025-07-08

Post by eschwellinger on CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC CODESYS Forge talk (Post)
I would recommend to ask Moxa for a newer version of Debian. Debian 9 ("Stretch") has reached its end of life and is no longer receiving security updates from the official Debian Security Team as of June 30, 2022. This means any systems still running Debian 9 are vulnerable to security risks and should be upgraded to a newer, supported version of Debian like Debian 10 ("Buster") or Debian 11 ("Bullseye").
Last updated: 2025-07-14

Post by attarzade on Servo motor as an slave and AC motor as an Mster CODESYS Forge talk (Post)
Hello, I would like to control a servo motor via EtherCAT as a slave axis, and have it follow a master axis that is driven by a Control Techniques C200 AC drive (ethercat communication).Could anyone help me with how to achieve this setup? I use codesys version 3.5.20 and crevis Ethercat cards. AC drive is master axis and Servo drive is slave axis Thanks in advance
Last updated: 2025-07-14

Post by jeroenaero on Autostart Targetvisualization 4.16.0.0 doesn't work on Linux device CODESYS Forge talk (Post)
Hi, How can we configure autostart of TargetVisualization on the remote device? The device is a Raspberry PI CM4 with PIXEL Desktop on display. I installed Targetvisu for Linux SL 4.16.0.0 on it. After each restart of the Raspberry PI CM4, we have to start Targetvisu fot Linux SL manually. i tried the step on this page: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html but i don't get it working
Last updated: 2025-07-24

Post by ivan-g on MODBUS CODESYS Forge talk (Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a Facebook post that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05

Post by ivan-g on MODBUS CODESYS Forge talk (Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a FB that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05

Post by yann2021 on Execute a .py file with Codesys CODESYS Forge talk (Post)
Hello, I have a Raspberry Pi 3 which has a printer connected to his USB port. I have a PiFace Board on the Raspberry. I have a python script file (.py) to print a logo + a text. The script is working because when I execute it from the Raspberry terminal it works. Now, when I push a button on the PiFace I would like to execute the python script file to print. How can I do that ? Many thanks for your help and advices!
Last updated: 2025-08-26

Post by nha451 on EIP Scanner not receiving data from adapter CODESYS Forge talk (Post)
Hello, I have an EtherNet IP adapter (GoPxL) running with a virtual PLC. I have successfully connected the adapter with green icons next to it. On WireShark I can see the data coming from GoPxL but on CODESYS it shows up as all 0. My firewall is turned off and I have enabled the device to always update variables. I tested my set up with Profinet and I can receive the data. Please let me know if you have any suggestions!
Last updated: 2025-09-12

Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
The problem has been resolved. Two findings are described below for future reference. The new RPi hw delivered during August 2025 has a MAC address from a new vendor series that is not supported by old runtimes. 4.17.0.0 or above is required. 4.17.0.0 does not pick up the correct architecture during installation and aarch64 has to be manually configured either in the GUI under operations or in /etc/codesyscontrol/CODESYSControl_User.cfg under the [CmpRasPi] section.
Last updated: 2025-09-16

Post by esther on subdevicesCollapsed attribute in deviceDescriptor CODESYS Forge talk (Post)
I was trying to use subdevicesCollapsed attribute in device descriptor in order to not expand the subdevices when a new device with subdevices is inserted in the device tree. I use this as follows:<fixed subdevicescollapsed="true">. But it seems it doesn`t work. I am ussing Codesys v3.5 SP16 Patch4. Is anything wrong with this? Or am I mistaken with the use of this attirbute?</fixed>
Last updated: 2025-10-01

Post by gseidel on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR] CODESYS Forge talk (Post)
Hi imdatatas, sorry to hear this issue caused so much overhead for you. Frankly, I'd expect a project created with an older version to compile without errors after opening > it with the latest Codesys version and updating all libraries. Yes, that is a reasonable expectation. I tried a few times but could not reproduce the problem. In case you run into the problem again, we can investigate the issue if you send a project archive. Best regards, Georg
Last updated: 2025-10-02

Post by mputaggio on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
Hello, We encountered the same issues on both recipe library versions 4.2.0.0 and the newest 4.3.0.0. The Arrays of structs get saved correctly but loading them restores only some indexes, while others get lost or completely wrong. We have been using the same recipes for the last two years on recipe manager vers. 3.5.17 withoud issues. There also seems to be a different behaviour in vers. 4.3.0.0 but it's still incorrectly loading the recipes. Did you find any workaround or solution? Codesys version used: 3.5.19.50
Last updated: 2023-12-15

Post by nathant on Some visualization objects disappear when user is logged in? CODESYS Forge talk (Post)
I am deploying a webvisu on Codesys 3.5 SP 19.2 with legacy user management. I noticed that when a user logs in, some text and a rectangle I have (for aesthetics) both disappear. I made sure that none of the objects in question are linked to a state variable. Anyone know the cause/solution to this? Nothing crucial to the machine's function is lost, but it is a little annoying.
Last updated: 2023-12-15

Post by spiessli on Softmotion axis to CANopen Maxon IDX drive CODESYS Forge talk (Post)
Hi, I want to use Maxon IDX drives for some simple robotic applications. I have used Maxon's Epos for generating a DCF file to import in Codesys (attached). Then I can add the IDX motors under a CANopen manager in the device tree. Unfortunately, I cannot add a "softmotion axis" to the IDX motors. Now I am wondering, why? Without being able to attach a softmotion axis to the device in the device tree, the use of the motor is greatly reduced... spiessli
Last updated: 2024-01-05

Post by wehling-h on PI Input value CODESYS Forge talk (Post)
Hi geoweil, have you tried to save changed values to remanent area or using a VAR RETAIN? After restart you have to initialize Counter with last remanent value. Depending on changes per cycle and the possibilitiy of your control unit to write remanent storage. Otherwise you need a buffering system to ensure save backup of last PI_Counter value. May you could read this Thread to get further help: https://forge.codesys.com/forge/talk/Engineering/thread/31e1c8349e/#bf48
Last updated: 2024-01-12