Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I updated the docker container runtime to version 4.11.0.0. and build the container with this "Dockerfile" FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.11.0.0" ENV EDGE_VERSION "4.11.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package '*codemeter*.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package '*codesyscontrol*.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codemeter start && /etc/init.d/codemeter-webadmin start && /etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"] Now cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 8.00 of 2023-Nov-28 (Build 5967) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. But still CODESYS development system reports that it needs a dongle and when I click install that "value cannot be null. Parameter name: containerToLicenses" It seems that Codemeter is forced to look for a dongle instead of a CMsoftcontainer. Can you confirm that CODESYS licensing works also when CODESYS is installed in a Docker container?
Last updated: 2024-03-21

Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Post)
For those who will step on this thread. Everything is fine, I had only to increase by 1 my place holders number. For sure the system is occupying the number 1 without being declared ... Below the modification I made to get my code working. [SysFile] PlaceholderFilePath.2=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.3=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.4=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.5=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22

Post by fabian on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
Hi all, Is there an update on this topic? Same problem here, I can not add more than 10 Modbus-Slave channels. Is there a workaround? Many thanks! Fabian Codesys 3.5.19 SP2, Modbus 4.3.0.0, Name: Modbus TCP Slave Hersteller: 3S - Smart Software Solutions GmbH Kategorien: Modbus TCP Slave Typ: 89 ID: 0000 0005 Version: 4.1.0.0 Bestellnummer: - Beschreibung: Ein Geraet, das als Slave für einen Modbus TCP Master konfiguriert ist. Version Konfiguration 3.5.11.0
Last updated: 2023-08-28

Post by ernesto881124 on ernesto881124 CODESYS Forge talk (Post)
Hello good morning everyone I would like to ask a question, is it possible to directly connect a device that only contains modbus RTU communication through an R-45 connector, directly to the PC? Or would you need an intermediate device to achieve communication? It would be of great help to me because I cannot achieve communication between the Codesys simulator plc and a Fuji Frenic mini VFD, please help me if anyone has had the same experience. Thank you so much
Last updated: 2023-09-13

Post by transmin01 on CANbus issue CODESYS Forge talk (Post)
Update: This initial issue was when using a Linux target PLC. Since then I have created a Win10 target PC and the Codesys software reported an issue associated with the device version (see attached). I am assuming this is an incompatibility with the xml file from the manufacturer and the firmware version on the module and I am chasing this up with Beckhoff. Question is, why would this not report with a Linux target?
Last updated: 2023-09-14

Post by transmin01 on PCAN serial "No CAN driver found" CODESYS Forge talk (Post)
Hi, I am using a PCAN mini CAN board which has the Windows drivers installed on the target PLC. PCAN board can be seen in device manager. However, I am getting "No CAN driver found" error. I have read the post https://forge.codesys.com/forge/talk/CODESYS-V2/thread/44aae19318/ and have uncommented the CmpPCANBasicDrv driver in the CodesysControl.cfg file in development PC and have copied it to the target PC. Current CodesysControl.cfg file attached. Is there anything else I am missing? Regards
Last updated: 2023-09-14

Post by timvh on CANbus issue CODESYS Forge talk (Post)
On a PC with the Control Win, this is probably related to the fact that the CAN drivers are not loaded. Go to the folder where your Control Win Configuration file is: - E.g. C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE - Open the CODESYSControl.cfg - Remove the semi-colon in front of the CAN driver you want to use (section ComponentManager). - Set the component ID to the next number in the list (e.g. Component.8) - Save this file and restart the Control Win.
Last updated: 2023-09-14

Post by jeffgamsby on Accessing ModbusTCP addresses from python CODESYS Forge talk (Post)
Hi, I am new to modbusTCP and I am trying to access Input registers from codesys (3.5.SP13). The offset is 16#0000 and I am trying to access Channel 1[24] %IW24 to pull analog values. I am using pyModbusTCP and I need to supply a modbus address and the number of registers to read. What does 16#0000 mean in terms of the actual offset, how do I translate this number plus the channel to access this info via python? Any help would be appreciated, thank you.
Last updated: 2023-09-20

Post by jantje on Setting up the "Visual Studio Code" debugging environment (using .NET debugging) for use with the ScriptEngine API in Python. CODESYS Forge talk (Post)
Hi Till, Sadly I did not get any feedback on this and was not able to get it to work using Visual Studio Code. I believe I have used a Codesys environment to get something up, but I cant remember any specifics, its too long ago. Good luck with it! Kind regards, Jan
Last updated: 2023-10-02

Post by chris12345 on IO-Link Lizenz CODESYS Forge talk (Post)
Hallo zusammen, ich arbeite mich momentan in das Thema IO-Link ein. Benutze einen Revolution Pi, IO-Link Master (AL1333 IFM), Sensor (OGD500 IFM) und ein IO-Link I/O Modul (AL2205 IFM). EDS-Dateien und IODD Dateien über das Geräte-Repro eingebunden. Bekomme jetzt folgenden Fehler:- Die Lizenz fehlt oder ist ungültig. Die SPS läuft im Demo-Modus. Welche Lizenz wird benötigt, um IO-Link fähigen Sensoren meinen IO-Link Master hinzuzufügen? Benutze die Codesys V3.5 SP19. Gruß Chris PS: Anbei das Bild
Last updated: 2023-10-09

Post by ofey on Symbol configuration / GVL CODESYS Forge talk (Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11

Post by damian177 on Codesys MQTT subscribe CODESYS Forge talk (Post)
Hi, In my project I have MQTT Client like below: //mqtt client mqttClient( xEnable:=connect_to_broker, sHostname :=sHostname, uiPort:= uiPort, xUseTLS:=FALSE, wsUsername:="", wsPassword:="", xCleanSession:=TRUE, sClientId:='694d45587761676f4b6f6e74656e6572', pbWillMessage := ADR(sWillMessage), uiWillMessageSize:=DINT_TO_UINT(Stu.StrLenA(ADR(sWillMessage))), xWillRetain:=FALSE, udiTimeOut:= 10000000); And ten subscriber's , one of those is below: //subscribe a topic1 mqttSubscriber_S1(xEnable:=subscribe, eSubscribeQoS := 0, pbPayload:=ADR(sSubscribeMessage_S1), udiMaxPayloadSize :=SIZEOF(sSubscribeMessage_S1), mqttClient:=mqttClient, wsTopicFilter:=wsSubcribeTopic_S1); TerminateString(ADR(sSubscribeMessage_S1), mqttSubscriber_S1.udiPayloadSize); After connected to broker I set subscribe to TRUE in alls subscribers and my mqttclient recive error : ACKNOWLEDGE_TIMEOUT what can be wrong ?
Last updated: 2023-10-11

Post by ofey on Symbol configuration / GVL CODESYS Forge talk (Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11

Post by eschwellinger on Persistence Manager Backup CODESYS Forge talk (Post)
you need at them moment a download once (for the configuration files generated including addresses) then stop the plc - exchange the persistence file ( without the config file) This will be improved to 3.5.18.6 and 3.5.20.0. (possible then to generate offline bootproject including full persistenmanager files) - this is if you have not 100% the same bootapplication on the devices. In case you copy the whole Application (PLCLogic) directory it should work out of the box - but only with 100% same bootprojects as mentioned above. By the CODESYS Automation Server would help solve this too.
Last updated: 2023-10-19

Post by mondinmr on Jitter problems on imx8 CODESYS Forge talk (Post)
SOLVED!!! In this imx8 max_cstate=1 in kernel boot parameters is not working! We found a workaround: #include <stdio.h> #include <fcntl.h> #include <unistd.h> #include <stdint.h> int main(void) { int fd; uint32_t value = 0; fd = open("/dev/cpu_dma_latency", O_WRONLY); if (fd < 0) { perror("Error opening /dev/cpu_dma_latency"); return 1; } if (write(fd, &value, sizeof(value)) != sizeof(value)) { perror("Error writing to /dev/cpu_dma_latency"); close(fd); return 1; } while (1) { pause(); } } This simple code launched before CODESYS do the same work! Now jitter is identical as measured by cyclictest!
Last updated: 2023-10-19

Post by simotion on Online view : code is scanned CODESYS Forge talk (Post)
If I do online monitoring of code in f.i. a function block, I cannot see if the function block is called or not. In software from other vendors you normally have an indication if the online code you are looking on is scanned at that moment or not. Is there a way in Codesys to determine in the online view if (parts) of the code are scanned or not? Thanks
Last updated: 2023-10-23

Post by davidbo on How to allow a user to handle certificates without access to sourcecode? CODESYS Forge talk (Post)
With CODESYS V3.5 it is possible for a user to do the following things among many others. 1) Handling certificates especially move a certificate to the trusted folder. 2) Change password and create new users for OPC UA access However it requires access to the whole projects and its source code. Something you might not want to hand over to an end user for a stand alone product. Is there a way out of this problem?
Last updated: 2023-11-06

Post by vformanek on OPCUA Datasource, can not login... CODESYS Forge talk (Post)
Hello? I have a problem with datasource... I am trying to connect to a OPCUA server. I create a datasource, but I can not login into it. I need to use login credentials to login... Everything works fine in UAExpert, but in codesys I cant seem to get in properly using the login credentials... I have tried to configure the datasource initializer but seem to keep failing... Do I need to call it somewhere ? Will the find endpoints work with this configured to store my password ? !
Last updated: 2023-11-20

Post by mmoncada on Dinamically loading recipes CODESYS Forge talk (Post)
I'm having trouble with the initial loading of recipes. I can create them and load one or the other, but when the program restarts the recipes are not listed. I'm calling: RecipeManCommands.ReloadRecipes and then RecipeManCommands.GetRecipeCount which returns 0 recipes. None of the methods returns error and if i call them again after RecipeManCommands.CreateRecipe RecipeManCommands.ReadAndSaveRecipe getRecipeCount returns the number of recipes created. When i restart the system, once again they are not listed even though the recipe files are there. Any ideas? Martin Btw, Codesys 3.5 SP 16 Path 9
Last updated: 2023-12-06

Post by nikgind on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi, yes i did solve it. You have to change the namespace 0 model in the UaModeler. Open the modeler --> Settings --> Edit Settings --> scroll down to the last option "External Model Support" --> Check "Allow replacing built-in..." Now create a new project in the UaModeler. If you have to choose your base models, you can see the option "Find another Opc.Ua.NodeSet2". I have attached the .xml i am using.
Last updated: 2024-06-28

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
Just to share, for those who as me are seeking for this and had found no information anywhere in this World: Every time I stop/start the PLC runtime ( turning into 'Stopped' or 'Running' state ) the 'CODESYSControlService' appears at the Taskmanager list, which could suggest a straight correlation. I was expecting a clever solution, but this one solves for while.
Last updated: 2024-07-02

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
It's already there, the service get started as default. I missed to say that sometimes it happens w/o even the system get restarted. Anyway, the main issue here is to know the state of the runtime. We collect a lot of informations about the whole system, and it would be nice to have a way to detect the runtime state.
Last updated: 2024-07-02

Post by installwhat on What is the solution for "Application stopped on recovery switch request"? CODESYS Forge talk (Post)
<Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:47" infoId="1">Axis#=121 , Error=30014 , Emergency 2 <Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:23" infoId="1">TCP Server : WaitClient <Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:23" infoId="1">TCP Server : Init What is "component="<10>"? Is this system a vanilla CODESYS RTE or is it a modified installation. I think more details are required.
Last updated: 2024-07-08

Post by srouse on PFC200BUS not running CODESYS Forge talk (Post)
I started a project in codesys for a WAGO 750-8212 PLC and I am working on getting online with the controller. I can log in to the controller and I can see and control all of the fieldbus couplers that I have. I am unable to get the internal bus working. It just says that the bus is not running and when I scan or devices nothing shows up. Am I missing something important in my device tree?
Last updated: 2024-07-10

Post by nano on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
in the codesyscontrol.cfg or codesyscontrol_user.cfg you have to declare whoch comport-ports from runtime are used. please tell us how the comport is called in linux an post the codesyscontrol.cfg files also write down here, which parameters are used in the python-script and what is parameteized in the modbus-master-comport of your codesys-application. mostly the errors occurs in ine of these areas
Last updated: 2024-07-11