Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
Hello, I'm trying to access the group IDs of the connected user. "CurrentUserGroupId" var shows only the first group ID that the user is assigned, I need the other group IDs that the user is in. I find some structs but I can't find where they are used, like "VUM_User" scruct from visuusermgmt, where can I find this vars? https://content.helpme-codesys.com/en/libs/VisuUserMgmt2%20Interfaces/Current/VUM_User.html abyUserGroupIDs seens perfect but I can't find a GVL where it is used.
Last updated: 2024-07-08

Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
I had my problem solved.
Last updated: 2024-07-10

Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
I had my problem solved.
Last updated: 2024-07-10

Post by eschwellinger on User management CODESYS Forge talk (Post)
CODESYS Automation Server could do this too..
Last updated: 2024-09-04

Post by automa on Defining local variables that can be independent with several users. CODESYS Forge talk (Post)
Hi, I am looking for a way to define a local variable that will be multi user independent. This is so several user can connect at the same time select frames independent of each other.
Last updated: 2023-09-04

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
please use latest version 4.9.0.0 and it is mandatory to have a user pi on your device.
Last updated: 2023-09-11

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
CODESYS runtime version 4.9.0.0 for your Pi. ssh user should be pi. This is for RasperrPi Os 32 bit. If you are on RasperryPi OS 64Bit use Arm 64bit SL product as Runtime.
Last updated: 2023-09-11

Post by hclai on Table Content with Multilanguage CODESYS Forge talk (Post)
I have an data structure which intend to list in a table and let user to add the content to the table. How can we able to support for displaying different language in the content of the table? which is dynamic to the user input.
Last updated: 2024-01-10

Post by ralfki on User management CODESYS Forge talk (Post)
Hello CodeSYS community, Is there a CodeSys function with which you can activate user management or is this only possible with the CodeSYS development environment? Thanks for the support
Last updated: 2024-09-02

Trying to pull Logged In user details and certain other variable values and in turn log to a database CODESYS Forge talk (Thread)
Trying to pull Logged In user details and certain other variable values and in turn log to a database
Last updated: 2024-11-07

Post by ragarcia on How to change login visualization for other visualization after user logged in CODESYS Forge talk (Post)
Hello everyone, I have a web visualization on Codesys and to be able to use the web visualization first an user and a password is requested. After the user logged in, I want to automatically change the visualization to the 'Home' visualization but I am not sure how to do this. In the login visualization I basically have a button with the input configuration to execute the action 'Login' after a click. Once the user is logged in, the visualization is still stuck in the login page and I want to automatically change to Home visualization if the user was succesfully logged in. How can I know the number of web visualization clients connected to my PLC? Thanks in advance
Last updated: 2024-06-04

Post by rafael on Wbm/runtime and visualization login CODESYS Forge talk (Post)
Hello everyone, I’m trying to understand if it is this way or I can change it. I’m making a PLC code and visualization screens, the ideia is to operate via webvisu some controls. So i made a code, made some screens and when i try it in my web browser, first it asks me to insert te user and password of the wbm/runtime of the plc (user: admin, password: wago by default), then i can acess my screens but I have to login again with the user and password that i created in the visualization user managment. My question is: is there a way to disable this first login to the visualization screens (webvisu)? Or create another user/password for this first screen? I have a PFC200 and a Edge Controller, both are working the same way. Thanks in advance Thanks
Last updated: 2024-06-25

Post by yang123 on EtherCAT Can't reconnect to servo drive CODESYS Forge talk (Post)
I am using Ethercat Master 4.6.0.0 and have use the automatic restart slaves feature. But we found of after the Ethercat communication normal and slave drive power-off and power-on the slave can't reconnect sucess. The PLC Log show the drive was al status "6#34 : Invalid DC Timeout Error" and its was reconnection sucess first but seconced later the drive will show the "16#2C : Fatal Sync error" and then drive will can't reconnection. Other slave are reconnect sucess which was link after the can't reconnect's drive the drive was OMRON R88D-1SN
Last updated: 2024-01-23

Post by struccc on Release SP20 - Changes in behaviour? CODESYS Forge talk (Post)
Dear all, I've just started to migrate some of my ancient projects to SP20. There is one strange error (?) I have noticed so far. In a method call, depending on the circumstances I would like to return reference to an object, or an invalid reference: METHOD Add_EVT_OUT : REFERENCE TO FB_MSG VAR END_VAR IF __ISVALIDREF(refMSG_Entry) THEN Add_EVT_OUT REF= MANAGER.AddMsg_EVT_OUT( refMSG_Entry, _Get_EVT_Message(MSG_EVENT.OUT), _Get_EVT_AddCode(MSG_EVENT.OUT) )^; ELSE Add_EVT_OUT := 0; END_IF So far setting a reference variable to 0, did this. But now, the expression Add_EVT_OUT := 0; gives an error: [ERROR] DB_WTP_370: Add_EVT_ACK MSG_TRIGGER_EXT: C0032: Cannot convert type 'BIT' to type 'REFERENCE TO FB_MSG' Naturally... I can write: Add_EVT_OUT := DWORD#0; But is this the correct way? Is there any constant I could use instead, like "NULL"? Or this is totally wrong and to be avoided?
Last updated: 2024-03-24

Post by timl on Application has invalid license metrics CODESYS Forge talk (Post)
Hallo, ich habe eine Control for Linux SL auf der ich einen TCP Modbus Master anlege, mit dem ich einen Slave auslesen möchte. Das Anlegen funktioniert soweit alles, sobald ich beim ModbusTCPSlaveE/A-Abbild in den Channel eine Variable einfüge, damit ich den Channel auslesen kann, kommt es beim übertragen auf die SPS zu einem Ausnahmefehler. Im Anhang noch eine Bilder der Fehlermeldung und der installierten Lizenzen. CODESYS Version ist V3.5 SP19 Patch 4 Meinem Verständnis nach ist die Modbus Lizenz mit in der Control Standard L inbegriffen und auch in der Lizensierten Softwaremetrik sehe ich keine überschreitung meiner Lizenzbegrenzungen. Daher verstehe ich nicht wieso ich diesen Fehler bekomme und eine auslesung via Modbus nicht möglich ist. Gruß Tim
Last updated: 2024-05-08

Post by t-probst on Strong Private Key Protection for Encryption Certificates CODESYS Forge talk (Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22

Post by davidbo on How to allow a user to handle certificates without access to sourcecode? CODESYS Forge talk (Post)
With CODESYS V3.5 it is possible for a user to do the following things among many others. 1) Handling certificates especially move a certificate to the trusted folder. 2) Change password and create new users for OPC UA access However it requires access to the whole projects and its source code. Something you might not want to hand over to an end user for a stand alone product. Is there a way out of this problem?
Last updated: 2023-11-06

Post by ekristoffe on Beispieldateien finden / Inhalt der Packages CODESYS Forge talk (Post)
Hello @eschwellinger, Why not using one of those 2 folders: C:\ProgramData\CODESYS C:\Users\Public\Documents\CODESYS The main reason is depending on the company and the user right, the end user may not have the access to use those folders. Also having a non version dependent folder may help if the end user uninstall a previous version and forgot all its sample project where in this previous version installation. Thanks.
Last updated: 2023-11-24

Post by nathant on Some visualization objects disappear when user is logged in? CODESYS Forge talk (Post)
I am deploying a webvisu on Codesys 3.5 SP 19.2 with legacy user management. I noticed that when a user logs in, some text and a rectangle I have (for aesthetics) both disappear. I made sure that none of the objects in question are linked to a state variable. Anyone know the cause/solution to this? Nothing crucial to the machine's function is lost, but it is a little annoying.
Last updated: 2023-12-15

Post by installwhat on What is the solution for "Application stopped on recovery switch request"? CODESYS Forge talk (Post)
<Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:47" infoId="1">Axis#=121 , Error=30014 , Emergency 2 <Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:23" infoId="1">TCP Server : WaitClient <Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:23" infoId="1">TCP Server : Init What is "component="<10>"? Is this system a vanilla CODESYS RTE or is it a modified installation. I think more details are required.
Last updated: 2024-07-08

Post by ralfki on User management CODESYS Forge talk (Post)
Hello eschwellinger, at first thank you for your answer. So the only ways to activate the user management are CodeSys delevelopment enviroment and the Codesys Automation Server. So there is no function to activate the user management via code? Do you have an idea how to get back the users when somebody replaced the PLC. Our customers have only our own developed visualization and they also don't want to install further softwares. Do you maybe have a solution for this
Last updated: 2024-09-04

Post by snhatton on Some visualization objects disappear when user is logged in? CODESYS Forge talk (Post)
Did you check the access rights of the visualization elements in question?
Last updated: 2023-12-18

Post by egau on Git - User identification data is lost when codesys is closed CODESYS Forge talk (Post)
It bothers me for sure.
Last updated: 2024-04-04

Post by ac-spr on Runtime variable that indicates a user is online to the code CODESYS Forge talk (Post)
Looking to access a variable at runtime that indicates a user is online to the code. essentially want to use this value to feedback to the user on the HMI. we use turck and bosch rexroth devices if this information helps. I was hoping there was a variable at the application level, or a library that could be used but I was unable to find anything. I know there's a pop up when you try to login/ go online to the code when a user is already logged in, so the system does provide an indication that it knows already online, but has no access to a value from what I can see. Any help is appreciated
Last updated: 2024-04-22

Post by kislov on How to change login visualization for other visualization after user logged in CODESYS Forge talk (Post)
https://content.helpme-codesys.com/en/libs/VisuElemBase/Current/Public-Parts/Interfaces/IUserMgmtEventHandler.html
Last updated: 2024-06-05