Post by hfelek on TargetVisu for Linux Package on runtime 4.12.0.0 install error due to Qt dependencies.
CODESYS Forge
talk
(Post)
Hi, I am trying to make my runtime support TargetViso on 4.12.0.0 runtime. First when I tried to install package I got error due to missing libraries that are generated through qt-base. After compiling and installing related qt lib when I tried to install the package, I didnt get lib dependencies error but I got another error: [ERROR] The installed QT Version does not meet the minimum required version 6.4.2. Please install version 6.4.2 or higher and try again. When I check Qt version I get the following response QMake version 3.1 Using Qt version 6.5.0 in /usr/local/qt6/lib. I tried with Qt version 6.9.0 but that didn't help. Any idea on what coudl be the reason. When I looked for codesys related processes the related libraries were included within environment.
Last updated: 2024-08-27
Post by elektron785 on Dongle von Linux-Modul (ARM64) nicht erkannt
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe Lizenzen für CoDeSys gekauft und auf einem Dongle installiert, in der Hoffnung, dass ich diese mit einem Verdin-Modul von Toradex verwenden kann. Leider wird mir aber im Lizenz-Manager angezeigt, dass der Dongle nicht gesteckt ist. Ich habe bereits beide USB-Ports versucht, aber die Fehlermeldung bleibt gleich. Ist das überhaupt die richtige Vorgehensweise über den Lizenz-Manager oder gibt es da noch eine andere Möglichkeit? Ich gehe mal davon aus, dass die Lizenz nicht automatisch erkannt und verwendet wird? Wie im angehängten Bild "usb" zu sehen ist, wird der Dongle auch als solcher erkannt.
Last updated: 2024-09-02
Post by micik on False Notification Application Error with raspberry pi 4
CODESYS Forge
talk
(Post)
Hello, I have just went through all steps shown on Codesys YT channel https://www.youtube.com/watch?v=RPoPscbo3Kc And it works, I have installed PI OS 32 bit and choose Single Core. However, immediattely when I create standard project with Raspberrz pi device, "Application" is underlined, like there is an error, but in reality there are no errors, and I cannot see what are these 3 messages like shown in attachment. Aside for this red underline, everything seems to work fine. How to correct this? Thank you! Update: I have found what errors are, but not sure how to correct them: Identifier 'IoDrvGPIO' not defined Function block 'IoDrvGPIO' must be instantiated to be accessed 'IoDrvGPIO' is no component of 'IoDrvGPIO'
Last updated: 2024-09-03
Post by thn-power on How to change OPC NodeId IdentifierType
CODESYS Forge
talk
(Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20
Post by danielbeers on Automation Server + Pi Gateway + PLC w/ CAN
CODESYS Forge
talk
(Post)
Hello, I have a project using some EPEC PLC's. Some of them are programmable using Ethernet and some use CAN. We currently have a Raspberry Pi that is acting as a gateway to the Codesys Automation Server and is successfully working for the PLC's communicating over ethernet. I am trying to achieve a similar result for the PLC's that have only CAN access. I have PEAKCan drivers on the Pi, and can successfully send/receive messages. But the Gateway does not recognise the PLC when scanned from the Automation server online. Is there a library or service that exists to translate the CAN messaging, to the Edge Gateway, and be able to achieve remote access with the Automation Server? Or is this not possible without creating something custom? Cheers, Daniel
Last updated: 2024-09-22
Post by timvh on Clarifications regarding the appropriate runtime system to use
CODESYS Forge
talk
(Post)
If you are not using any specific Raspberry Pi functionality, then probably the "universal" Control Linux ARM SL is the approriate runtime to run on the Pi. For the license it doesn't matter which runtime version you choose, because this is not hardware based anymore, but application based. Best is to use the latest version of CODESYS. To determine which license you need, double click on your device, go to the tab License metrics.... Generate the code for your application and see which license you need based on the metrics of your application.
Last updated: 2024-09-24
Post by timvh on FB string and naming
CODESYS Forge
talk
(Post)
I see, you want to initialize the FB. To be able to initialise it like you described, you need to add the FB_Init method to your FB. (right click on the FB, select add object --> method). Then press the arrow down, to select the FB_Init (overwrite default implementation). In the VAR_INPUT section of this method, add the variable --> Tag : STRING; Then in the code section of this method add: THIS^.Tag := Tag; // copy initial value to local variable in FB Search Google if you want to know more about FB_Init. PS, reflection + instance path, is also an option if you want to get the full name of the instance (path) of the Function Block. See: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_instance_path.html
Last updated: 2024-09-30
Post by pernockham on Linking to IO during runtime with hot swap?
CODESYS Forge
talk
(Post)
I have a project where a single PLC shall control multiple nodes (up to 10 units?) with IO connected through profinet. Ideally each node should be identical however with time I see situations were different setups/configurations will be used. Codesys PLC (GVLs) |Profinet | |--PNIO-node-1--| | | AIO, | | DIO, | | CNT etc. | |--PNIO-node-2--| | | AIO, | | DIO, | | CNT etc. Ideally I think of a configuration through yaml/xml-files (the assignment/linking of the profinet nodes towards GVL-variables in the PLC as well as scaling, channel configration etc.). Would be grateful if someone could suggest library/-ies that can handle the following: - Verify what IO is connected to a device/node. - Hot-swap/assign link for IO towards GVLs, either automatically or through a HMI.
Last updated: 2024-10-11
Post by timvh on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
RS485 doesn't seem very logical to use in VPLC's in my opinion. I also don't know if this is supported.... But for TCP/IP, I think you still need to configure the Nic settings. See the attached png. In my case enp6s0. When changing this setting, restart the VPLC. What is really nice, is that you don't have to configure the IP address setting in Linux. By setting the Nic to a certain IP address in the CODESYS instance configuration, this is automatically done for you. I only tested this with EtherCAT, but I guess this works the same for Modbus TCP/IP.
Last updated: 2024-10-23
Post by gediminas on Datasource OPC UA client system failure
CODESYS Forge
talk
(Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Ok, with debug you suppress the errors, but that doesn't help you any further. You can find information about the missing drivers here https://forge.codesys.com/forge/talk/Runtime/thread/8981ce928a/ and here https://github.com/stefandreyer/I2C-Multiplex I'll have to have another look at which library you need. But you can easily find out. Create a completely empty project and insert the TCA9548. You don't need the board. Then look in the library and resolve all conflicts If you can compile the project without errors, delete the TCA9548 and insert the ADS1115. The driver should then also run. Small bonus: with the TCA9548 you can expand your network as you wish and use identical sensors multiple times
Last updated: 2024-11-08
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Ok, here are the libraries I use. First of all, try to get the ADS1115 to run completely on its own. Without MUX or other sensors. As muxboard I use this one: https://www.digikey.de/de/products/detail/sparkfun-electronics/BOB-16784/12714950?utm_adgroup=&utm_source=google&utm_medium=cpc&utm_campaign=PMax:%20Smart%20Shopping_Product_Zombie%20SKUs&utm_term=&productid=12714950&utm_content=&utm_id=go_cmp-18521752285_adg-_ad-__dev-c_ext-_prd-12714950_sig-Cj0KCQiA88a5BhDPARIsAFj595gkPXWPT8aa-EixL97BDWjO988WDhcx-iHOVbqb_H8CLpHBcwLuJW0aAu1JEALw_wcB&gad_source=1&gclid=Cj0KCQiA88a5BhDPARIsAFj595gkPXWPT8aa-EixL97BDWjO988WDhcx-iHOVbqb_H8CLpHBcwLuJW0aAu1JEALw_wcB All other boards don't work for me either. The terminating resistor is missing Important: Before you install the drivers, remove all other device drivers. My drivers are all located in ‘Raspberry I2C MUX_11_2023’
Last updated: 2024-11-11
Post by patrik on Application failing to boot after system reboot
CODESYS Forge
talk
(Post)
Hi! I'm having issues with my applications failing to boot up after the hardware getting restarted by the customer. I've attached a picture of the related log lines in the PLC log. I'm running this on a windows server. The version I'm currently running is CoDeSys win V3 x64 3.5.19.50 Is there any way to get more information why it's failing to boot? I've had this issue on several versions of the runtime. I don't think it's version related but I don't know. All I know is that sometimes when the client gets a power outage or something that kills the machine some of my applications fail to boot. Any help is deeply appreciated. Thanks in advance!
Last updated: 2024-11-20
Post by kevinrn on Github Actions CI/CD tasks - development topic
CODESYS Forge
talk
(Post)
Hi @steven-schalm, Thank you for your inquiry, and I apologize for the delayed response! We use GitHub Actions cloud runners for this purpose, as it eliminates the need to maintain our own build runners. You can get started by creating a free GitHub account, which includes complimentary minutes for running actions on Windows runners. You can find an example implementation in our repository: https://github.com/powerIO-GmbH/action-codesys-setup I'm currently working on making additional features public, including: Git checkout functionality, Code signing, Custom script execution However, these additions require some preparation before release. Feel free to contribute to the project! BTW: You can also execute this locally, even the yml files with nektos/act on your windows dev machine.
Last updated: 2024-11-27
Post by dsa28 on OPC UA subscriber not operational
CODESYS Forge
talk
(Post)
Hi, Thanks for the reply. Please note that the information and links provided are related to OPC UA Client/Server. My problem was related to OPC UA Pub/Sub. In the end I have managed to establish OPC UA Pub/Sub communication between Codesys and TwinCAT systems. Keep in mind that OPC UA Pub/Sub example is not provided in the latest library version 1.1.0.0. The user needs to download the previous version to get the example. During the configuration I ended up with some doubts regarding the usage of IEC_ARRAY type in the dataset definition (see attachment). Can you please give more information on how to use this type? Many thanks.
Last updated: 2024-11-29
Post by akfarslan on The application does not exist on "device"
CODESYS Forge
talk
(Post)
Dear All, I am using CODESYS 3.5.19 SP4 with a PLC device. When I try to download my program to the device, I get the error: "The application 'Application' does not exist on the device". Additionally, after restarting the device, the program does not run automatically. When I connect to the device using WinSCP, I can see that the application.app file is uploaded to the root directory, but the device does not automatically start the application. I tried using the Create Boot Application option, but it does not resolve the issue. Is there another configuration step I am missing? How can I fix this problem? Thank you, Best regards,
Last updated: 2024-12-17
Post by climblinne on OPC UA Method - How to wait for result?
CODESYS Forge
talk
(Post)
Hello, I am already able to run an OPC UA method in Codesys. Now my question, how can I interact with other tasks (e.g. read an SDO from EtherCAT and return it by the function)? The OPC UA method seems to be called only once (I tried to return BOOL or UINT values). Up to now I only found to do a while loop to wait for the result of the other task. Is there a better way to do it? Is this the way OPC UA functions should be used (for "not too long" function calls) or should I use another mechanism (method: Start, event: Finish, method: getResult)? Regards
Last updated: 2025-01-13
Post by malie on 3.5.19.7 Alarme importieren in Gruppe funktioniert nicht
CODESYS Forge
talk
(Post)
Hallo, ich hab das Problem eine Alarmliste nachdem exportieren mit oder ohne Eweiterung der Liste wird nicht wieder importiert. Unter Meldungen "Import von Alarmen" steht: "Ein Element mit dem gleichen Schlüssel wurde bereits hinzugefügt.(Zeile 0, Spalte 0)" "Import der Alarme erfolgreich abgeschlossen" Es erscheinen aber nirgends die Alarme, in vorherigen Versionen hat das immer ohne Probleme geklappt. Auch ein ändern der ID und der anderen Spalten, hinzufügen und entfernen von Spalten hat leider nicht geklappt. Selbst wenn ich eine Zeile in der Alarmgruppe erstelle die Funktioniert, diese exportiere, die Zeile lösche und wieder importiere kommen immer die gleichen Meldungen und kein Alarm wird importiert. Ich hab die Funktion schon länger nicht mehr gebraucht, deshalb kann ich nicht sagen seit welcher CoDeSys Version die Funktion nicht mehr funktioniert. Hat hier jemand eine Lösung? Gruß Max
Last updated: 2025-02-06
Post by pedegani on "Do you really want to perform" dialog boxes
CODESYS Forge
talk
(Post)
I have the same annoying problem. The confirmation prompt for every single action appeared recently after an update from CODESYS 3.5 SP20 Patch 3 to Patch4, but I don't think it's due to this. Having to confirm every operation while debugging an application is a considerable waste of time and does not help at all to concentrate on development, not to mention that many times you miss the long-awaited event because you are busy looking for the 'yes' button to resume debugging or force a variable. Does anyone know how to disable the confirmation messages?
Last updated: 2025-02-14
Post by itsthefabs on (no subject)
CODESYS Forge
talk
(Post)
Hallo zusammen, ich nutze eine Wago 8212 als Modbus Client (in früheren Codesys Versionen hieß der Modbus Master) und habe einen weitere Wago 8212 als Modbus Server (früher Modbus Slave). Bisher habe ich für den Client den Funktionsblock FbMbMasterTcp aus der WagoAppPlcModbus-Library genutzt. Zukünftig würde ich das allerdings gerne über das Anhängen eines Modbus-Geräts am Ethernet-Knoten im Projektbaum realisieren. Zum besseren Verständnis habe ich ein Bild beigefügt. Der Modbus mit dem Server läuft auch. Kommt es allerdings zum Fehler des Modbus, z.B. kurzzeitig keine Verbindung oder timeout, wird der Fehler nicht automatisch quittiert. Ich muss dann manuell über den Status des Server-Knotens einen Button mit "Bestätigen" drücken. Im Betrieb kann ich mich aber nicht jedes Mal einloggen um einen Fehler zu quittieren. Gibt es hier irgend einen Trick, wie ich das aus dem Programm-Code quittieren kann? Vielen Dank schon einmal.
Last updated: 2025-02-26
Post by peterkcontrols on Copying 2 byte word to output
CODESYS Forge
talk
(Post)
Hello. I am using codesys 3.5. I would like to know if it is possible to set a variable to an output without declaring in. I have defined a STRUCT and within this struct I have a Struct for inputs called I and a struct for outputs called O. I have declared a variable of the type of this Struct, I would like to set or alias the value in this variable to an input/output value of an IO block that has a module on the ethernet tree. Is it possible to copy the contents of %IW0 -> STRUCT.I ? The size of both of these is 2 bytes. I understand that I can declare a variable with the input like Input01 AT %IX0.0 : BOOL; However how can I make STRUCT.I.D00 AT %IX0.0? Is this possible? Thanks
Last updated: 2025-03-03
Post by trusty-squire on AXIS Rollover
CODESYS Forge
talk
(Post)
If you mean you want to shift the Origin or Zero position of your axis, you can try MC_SetPosition and set the position to 0 (if you want to take the current active position and make it the new 0. Adjust this number accordingly if/as needed). This means the servo drive keeps it's current origin position, and Codesys applies an offset to the servo drive position in the logic. You can also use the homing function of your servo drive using MC_Home and have your drive configured to set the current position as origin when it receives a homing command.
Last updated: 2025-03-11
Post by dkugler on HMI über Webbrowser
CODESYS Forge
talk
(Post)
Auf die Schnelle fällt mir keine Möglichkeit ein, wie die Webvisu aus dem WebBrowser heraus den PC auf dem der Browser läuft, direkt beeinflussen, sprich herunterfahren könnte. Die Webvisu ist ja letztlich nichts anderes, als eine HTML Seite, die im Browser angezeigt wird. Als einzige Lösung fällt mir der file transfer (Beispiel findest du hier https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_visu_logging_of_variable_value_changes-1799730.html) ein. Du könntest über einen Button in der Visu z.B. eine Datei shutdown.txt von der PLC an den IPC senden. Auf dem IPC müsste dann entsprechend ein Dienst laufen, der zyklisch schaut: Datei shutdown.txt vorhanden, wenn ja, Datei löschen und IPC herunterfahren. Viel Erfolg!
Last updated: 2025-03-12
Post by alberto on ExportPLCopenXML is failing
CODESYS Forge
talk
(Post)
I'm trying to export my whole project through the option ExportPLCopenXML. It seems working, but when I'm trying to import the xml I have the following error during the importation process: Object reference not set to an instance of an object. It seems a usual issue with this process that affects to the pointer to user classes inside a procedure. I receive this error for two general functions that have this pointer declarations in the VAR_INPUT section. It seems a bug into the export/import process of CodeSYS and I couldn't skip it so far. Anyone could help me? Thanks in advance.
Last updated: 2025-03-15
Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue
CODESYS Forge
talk
(Post)
Hello, I noticed that version 0.0.0.6 is now available, so I tested it using CODESYS V3.5 SP19 Patch 7 and SoftMotion 4.17.0.0. While the project compiles and downloads without issues, I encountered a problem with the 'Enable: GPIO pin number that is set when the axis is enabled (with MC_Power) (0: not used)' functionality — it no longer works (HIGH level not present at the output pin). I observed the same behavior with version 0.0.0.5, whereas version 0.0.0.4 functions correctly. Could you help me identify what might be causing this issue or suggest how to resolve it? Thanks.
Last updated: 2025-03-19