Search talk: i/o drivers

 
<< < 1 .. 83 84 85 86 87 .. 125 > >> (Page 85 of 125)

Post by wmoon on Licensing info not available. CODESYS Forge talk (Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20

Post by danieldiaz on Problem with FB execution CODESYS Forge talk (Post)
Hello everyone, I've been working on a system which needs an error function, with this purpose I've created a FB programmed in LD, after debugging I run the simulation. It seems that the variable linked to a coil doesn't change the value when the contacts are associated to input variables. When I use internal variables the logic works properly. I don't know if the problem is related to the variables definition or with the logic program. As you can see in the image, I1 and I2 are variables declared on the FB, the rest are input variables. If I force the eStop and Reset signals to TRUE the coil value should change, but it doesn't. However in the second network if I1 is TRUE the coil change to TRUE as it has to be. To sum up, my doubt is why that coil doesn't change its value? I would like someone to shed a light on this. Thanks!
Last updated: 2024-04-02

Post by kblundy on Change the Opening Position of the Dialog using VU.FbOpenDialog CODESYS Forge talk (Post)
I hope the community can help me with this. I need to use the Visu Utils FbOpenDialog to control the opening and closing of a dialog. I have the Opening and Closing working, but I can’t get the dialogue's position to be controlled. The code looks like this: PROGRAM OPEN_DIALOG VAR xOpenLatchSettingDialog : BOOL; TopLeftDialog : VisuStructPoint ; fbOpenLatchSettingsDialog : VU.FbOpenDialog ; END_VAR IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog:= FALSE ; TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog(sDialogName := 'visu_AlarmLatchSettings', xExecute := xOpenLatchSettingDialog , xModal := TRUE, itfClientFilter := VU.Globals.OnlyTargetVisu, pTopLeftPosition := ADR(TopLeftDialog)); CloseVisuDialog(sDialogName:= 'visu_AlarmLatchSettings'); ELSE xOpenLatchSettingDialog:= TRUE ; IF fbOpenLatchSettingsDialog.xError THEN xOpenLatchSettingDialog := FALSE; END_IF END_IF I can't seem to work out a way to make the values in TopLeftDialog.iX and TopleftDialog.iY be passed correctly in the call and for it to change the position of the dialogue box. The code is compiled, but the position has not been changed. Any guidance or suggestions for revising this code would be incredibly valuable. Your insights could be the key to solving this issue.
Last updated: 2024-05-05

Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection) CODESYS Forge talk (Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06

Post by paulg on RasPi CAA Serial example - unexpected behavior during debug CODESYS Forge talk (Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06

Post by nikgind on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi I am trying to import a custom information model that I created using UA Modeler. I have only added two new methods and two new object types. It is possible to add the information model to the Communication Manager and the two new object types are shown in the Information Model tab. After compiling i get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://yourorganisation.org/Bsp_3.1/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway I have installed the information model from 15/12/2023 but not from 15/09/2021. Which makes the error message even stranger.
Last updated: 2024-06-09

Post by fizzy-bubblech on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Colleagues, i have the same problems. At the current time, I have to use the new version of the Codesys (3.5.20.10) + Control for Linux SL 4.11.0.0, but it works unstable : theree are a lot of freezes and not-respondings. I tested this on different projects: those that were created in the current version of the project, and those that were migrated from other versions of the development environment. Compiling a project without connecting to a controller is fast enough. The first downloading of the code into the controller, too. But as soon as you need to make edits and download a new code problems begin. Codesys "freezes" at the "Generation code" stage for 15-20 minutes. And only after that time loads the code into the controller. Previously, we used version 3.5.17.60 + Control for Linux SL 4.7.0.0. The process took 1-2 minutes. Do you have any ideas how can i fix it? I will be grateful for your answers.
Last updated: 2024-06-27

Post by farren on How to stay in a method until something is finished. CODESYS Forge talk (Post)
I know I'm thinking about this wrong -- too many decades of procedural and event-driven programming and only a few months of PLC ST programming...... I've created a visualization with a button that when pushed calls a method. I want the method to take a pressure reading, wait one minute and then take another pressure reading. I'm looking for leaks. I'm using TON for the delay. It seems like what is happening is that the method gets called once and it takes the first reading and starts the TON. But then execution continues, leaves that method call, and the second reading never happens. I can force the method to keep running until the whole thing is done with a While loop, but I understand that is considered BAD in PLC programming. If it push the button again to call the method again, it picks up where it left off and if the timer is complete then it runs the remaining code. How do I keep that method running until it is complete with just one call without using a while loop that ties up the PLC for a minute? Thanks! -Farren
Last updated: 2025-10-31

Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs CODESYS Forge talk (Post)
I have a project with several buttons and dialogs. Most of the dialogs are opened using the Open Dialog action of the Input configuration of the buttons. Some dialogs are openend using the FbOpenDialogExtended FB of the Visu Utils library and the FbOpenDialogExtended FB is called in the Execute ST-Code action. I am also using the FileOpenSave dialog from Visu Dialogs which requires an OnDialogClosed action to read out. I realized that the OnDialogClosed action which is meant for the FileOpenSave dialog also triggers if a dialog is closed, which was previously openend using the FbOpenDialogExtended FB. Is there a way to detect which dialog was closed last and specify to which dialogs the OnDialogClosed action reacts?
Last updated: 2023-09-20

Post by lraja on Codesys Programming with phyBOARD®-Pollux i.MX8M Plus CODESYS Forge talk (Post)
Dear All, I am trying to Developing a PLC using phyBOARD®-Pollux i.MX 8M Plus. It is very difficult to find the suitable Codesys control for i.MX8M. I have tried to install CODESYS Control for Linux ARM SL , but unable install it and I am getting the following error, [INFORMATION] Executing SSH command on root@192.168.0.10: Retrieving architecture from package management [ERROR] Expected exit value of command failed: expected 0, received 127 [INFORMATION] Standard output: sh: line 1: dpkg: command not found Kindly check and help phyBOARD®-Pollux i.MX 8M Plus Link : https://www.phytec.eu/en/produkte/single-board-computer/phyboard-pollux/
Last updated: 2023-09-23

Post by simotion on Pointer to Softmotion axis CODESYS Forge talk (Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25

Post by janber0206 on Gateway doesn't come online, regarding a working internet connection CODESYS Forge talk (Post)
Solved (see comment) Setup: Kunbus RevPi Connect+ (a raspberry based PLC) Codesys runtime package: 4.5.0.0 (raspberry, armhf) based on Codesys V3.5.18.20 Edge Gateway: 4.5.0.0 (edgearmhf,armhf) EN: The edge-gateway was added over a year ago to the automation server. I now need to make a few changes to the Codesys software, but the Pi is not showing as online in the Automation Server. Internet connection is established, I have remote access to the Pi via RealVNC. Anyone have an idea how I can solve this? Some screenshots added. DE: Ich muss nun ein paar Änderungen an der Codesys-Software vornehmen, aber der Pi wird im Automation Server nicht als online angezeigt. Die Internetverbindung ist hergestellt, ich habe über RealVNC Fernzugriff auf den Pi. Hat jemand eine Idee, wie ich das Problem lösen kann?
Last updated: 2023-10-26

Post by dhumphries on install codesys runtime on linux CODESYS Forge talk (Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04

Post by fabian on Sys Process Execute Command CODESYS Forge talk (Post)
Hello, I have a question: Once the command is being executed, is there a way to kill it again? As the called application is running in the background, the user can't close it but it shall be closed/terminated, commanded by codesys. I have tried with "SysProcessTerminate" but I guess this is not correct as the RTE crashes when this function is called. Starting the application: IF GVL.xStrtQR THEN GVL.xStrtQR := FALSE; SysProcess.SysProcessExecuteCommand2(pszCommand:=sCmd, pszStdOut:=stdout, udiStdOutLen:= SIZEOF(stdout),pResult := ADR(GVL.pResQRTsk)); END_IF Trying to stop it again: IF GVL.xTrmQR THEN GVL.xTrmQR := FALSE; pResTerm := SysProcess.SysProcessTerminate(hProcess:=SysProcess.SysProcessGetCurrentHandle(pResult:=ADR(GVL.pResQRTsk))); END_IF Codesyscontrol Win x64, 3.5.19.10. Many thanks for any advice pointing to the correct direction.. :-) Regards, Fabian
Last updated: 2023-11-17

Post by mahmutbeyaz on Create a Motion Profile CODESYS Forge talk (Post)
Dear All, I hope first to get notice and somebody answer my question. How can I create a motion profile with the axis following it (once or periodically)? As my research shows, Schineder has a UI-based (Motion Sizer) program that helps create a motion with different configurations, which is Codesys-based. I need to create a motion profile based on position, changing the speed. (i.e., 0-300mm moves with 300 mm/s, 300-400mm moves with 500 mm/s, 500-800mm moves with 1000 mm/s, and 800-0mm moves with 2000 mm/s). MC_PositionProfile does it time-based, which is not working for me as the axis may not stabilize the position in time, which may cause a big failure in the system.
Last updated: 2023-11-30

Post by appling on License status of Linux 64Bit runtime via CLI CODESYS Forge talk (Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04

Post by cfam on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Good day All I would like to share some information on this site for the Codesys team as well for the future members using Codesys Control for PLCnext if it is allowed. I hope that i Post it in the correct spot. Subject: Codesys, Codesys Control for PLCnext Objective: Using the following Phoenix components to built a PLC Rack and run it on Codesys: Hardware and Software used 1. 2404267, AXC F 2152 - Controller 2. 1088136, AXL F BP SE6 - Module carrier 3. 1088129, AXL SE DO16/1 - Digital module 4. 1337224, AXL SE PD16 GND - Potential distributors 5. 1088127, AXL SE DI16/1 - Digital module 6. 1337223, AXL SE PD16 24V - Potential distributors 7. 1088123, AXL SE AO4 I 4-20 - Analog module 8. 1088134, AXL SE SC-A - Cover 9. Codesys v3.5 SP19 Patch 4 10. Codesys Control for PLCnext V4.10.0.0 Process: Firstly I built the Rack according to the Phoenix Project+ Software tool. Where I rebuilt it onto my test bench . I used the PLCnext Engineer IDE from Phoenix and all Communications where up and running and my PLC program executed successfully. THEN I tried the same PLC Layout with Codesys and Codesys Control for PLCnext. It was not successful and gave me the "Error: Local Bus not Running". I searched the web for answers but was unsuccessful in finding a solution. So I tried to change my configuration and found that the following Modules COULD NOT be recognized by Codesys Control. The result was that the Local Bus Failed to run. 1337224, AXL SE PD16 GND - Potential distributors 1337223, AXL SE PD16 24V - Potential distributors Example 1, Resulted in "Error: Local Bus Not Running": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1337224, AXL SE PD16 GND - Potential distributors Module carrier slot 3: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 4: 1337223, AXL SE PD16 24V - Potential distributors Module carrier slot 5: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 6: 1088134, AXL SE SC-A - Cover Example 2, Result "Successful": Module carrier slot 1: 1088129, AXL SE DO16/1 - Digital module Module carrier slot 2: 1088127, AXL SE DI16/1 - Digital module Module carrier slot 3: 1088123, AXL SE AO4 I 4-20 - Analog module Module carrier slot 4: 1088134, AXL SE SC-A - Cover Module carrier slot 5: 1088134, AXL SE SC-A - Cover Module carrier slot 6: 1088134, AXL SE SC-A - Cover Result: Codesys or Codesys Control for PLCnext, has a PROBLEM to identify the following Modules. 1. AXL SE PD16 24V - Potential distributors 2. AXL SE PD16 GND - Potential distributors Hope that this information could be useful in future. Best regards Jaco Pretorius
Last updated: 2023-12-06

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
Hi there, I'm running the Codesys runtime on Windows 64 and I need to know if it is on "Running" or "Stopped" state just after a system crash. The following commands works perfectly well to (re)start it... net stop “CODESYS Control Win V3 - x64" net start “CODESYS Control Win V3 - x64" ...however I'm unable to determine when it is required to be call; I mean, by checking the System Tray icon, it is possible to know if it is on "Stopped" state, but I wanted to run a .BAT command to retrieve it. How can we do that?
Last updated: 2024-07-02

Post by nico-hefr on Python script command for "Access Control" CODESYS Forge talk (Post)
Hi everyone, I use Python Script to generate some POU in Codesys V3.5 SP19 and I would like to limit the "Access Control" to them thanks to the Python command. Is there any commands that allow to edit the "Properties... >> Access Control" of the POU? The other possibility is to set the permissions with "Project >> User Management >> Permissions... >> Project objects >> Modify >> ... >> myPOU", but I did not find the related Python commands. Otherwise, is there a global setting that allows to set the permissions by default? For example, Modify = Denied for everyone user by default. Thank you in advance for your help, Nico
Last updated: 2024-07-18

Post by jnoyau on Visualisaion while in simulation CODESYS Forge talk (Post)
Hi all, Im new to Codesys 3.5, and am in the process fo making a visualisation i'd eventually export towards a Wago device. The issue I'm having currently is that when I compile and connect to the simulated program, my simulation won't launch. On the Visualisation tab, all I get is a text message (where previously there was my prepared visualisation) that says "The visualisation awaits a connection. Start the application" One thing to note: I work with Codesys 3.5 in french, so this is a rough translation. And a second: I'm not getting any errors nor warnings about the visualisation tab itself upon compiling Is there a step i'm missing after launching my simulation? Or would it be some really specific issue caused by the way I've set up my program? Thanks, J
Last updated: 2024-07-31

Post by dawidr on Best practices for querying multiple MODBUS devices CODESYS Forge talk (Post)
Hi! What are the best practices for querying multiple Modbus devices? Single PRG or maybe multiple PRG (so basically multiple thread) per each Modbus device. In my current implementation I'm using single PRG and I'm utilizing FbMbMasterMultiQuerySerial and WagoAppPlcModbus.FbDigitalTwinMbSlaveDevice in eCockpit with PFC200. I've the timer with 2 seconds delay there and it was working fine for single device. But now I have three Modbus devices and for two of them I need to run 2/3 queries to get data from all registers. I noticed that the delays for getting the data from the Modbus devices is much bigger right now.
Last updated: 2024-07-31

Post by paulg on Converting hex bytes to float CODESYS Forge talk (Post)
I'll be capturing a hex stream over serial into a RasPi and I'd like to convert a group of bytes into a float. I see this is available (https://content.helpme-codesys.com/en/CODESYS%20Development%20System/cdsoperatorrealto.html) but not its inverse (i.e. BYTE_TO_REAL). The packets will be 18 bytes but I'll be selecting 4 byte segments from the middle, swapping byte endianness (i.e. changing 0x51847641 to 0x41768451), and converting to float; I believe they adhere to IEEE 754. Is there a pre-built function for some or all of this, or do I need to follow (https://forge.codesys.com/forge/talk/Engineering/thread/dc5829c7ea/)? Thanks!
Last updated: 2024-08-02

Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager CODESYS Forge talk (Post)
Hi, In Codesys V3.5 SP20, using Data Source Manager I am trying to connect to the OPC UA server and receive tags from it. The connection is ok, but the Codesys have a problem with downloading Tags group. The window (downloadingTags.jpg in attachement) never stop. After waiting for a while, I disconnect the connection and only the Server group remains downloaded, with OPC UA server diagnostic data (and this is read in Codesys). Of course, I tried connected via another OPC UA client : UaExpert , and everything works as it should, all tags are downloaded (Uaexpert.jpg screen). Has anyone on the forum encountered the OPC UA client configuration in Codesys? Is it possible to manually request the appropriate tags from the OPC server for reading in Codesys?
Last updated: 2024-09-03

Post by trusty-squire on How to revert to previous version library CODESYS Forge talk (Post)
Hi, I'm experiencing a bug with the latest version of SoftMotion CNC library (4.17), where the 3DPath object in Visu is missing all the important properties. I've verified that a previous app I was working on with library version 4.16 did not have this issue and the issue is duplicated in that project when I update it to 4.17. I've already submitted a bug report, but for the time being I need to revert the project I'm currently working on back a revision. I've tried right clicking on the library but the option to select the version is greyed out. Can anyone help me?
Last updated: 2024-09-05

Post by micik on Start Codesys project and then execute python script from command line CODESYS Forge talk (Post)
Hello, by searching the forum, I have found an example of batch script that can be used to start codesys projct by temporarily setting env variables. However, I'm not sure how to modify this to start Codesys 3.5.20 and whether or not I need to specify "profile" with Codesys version at all. @echo off SET PROJECT=D:\TestScripts\Data\OnlineTest.project SET VARIABLES=POU.testint,POU.testoutput start /wait CoDeSys.exe --profile="CoDeSys V3.4 SP3" --noUI --runscript="D:\TestScripts\Forum_Environment.py" I have tried the following just to open the test project: SET PROJECT=C:\TEST\Example.project start CODESYS.exe --profile="CODESYS V3.5 SP20 Patch 2" But I'm not sure how to specify this project to be open after py script is executed. The py script should first add required library to the project and then project should be open.
Last updated: 2024-09-30

<< < 1 .. 83 84 85 86 87 .. 125 > >> (Page 85 of 125)

Showing results of 3118

Sort by relevance or date