Search talk: -128到127是什么数据类型

 
<< < 1 .. 842 843 844 845 846 .. 888 > >> (Page 844 of 888)

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Update: I found my error in the Scale function, where I used UINT_TO_REAL instead of DWORD_TO_REAL. I fixed it, errors unchanged.
Last updated: 2024-05-02

Post by eschwellinger on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
it is mandatory to activate the OPC DA license into the 32-xxxxxx legacy container (not UFC) you need a remove ticket -> contact CODESYS store - my question to move the license
Last updated: 2024-05-03

OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Thread)
OPC Da Server Code Meter Issues after Enabling License
Last updated: 2024-05-03

Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
I'm trying to get the OPC server setup on my machine and currently I'm not having luck. I went ahead and got my license setup. However when I go to run WinCoDeSysOPC.exe I get an error message that I don't have the code meter licenses installed. Does anyone have any ideas on how I can fix this issue?
Last updated: 2024-05-02

Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
Additionally the license is loaded on the soft storage for my device but it shows up as invalid. I just activated it today.
Last updated: 2024-05-02

Post by mjk97 on CFC Toggle Function CODESYS Forge talk (Post)
Last updated: 2024-05-03

CNC / G-Code streaming processing ( to start quickly in long G-Code File ) CODESYS Forge talk (Thread)
CNC / G-Code streaming processing ( to start quickly in long G-Code File )
Last updated: 2024-05-03

Post by k2saki on CNC / G-Code streaming processing ( to start quickly in long G-Code File ) CODESYS Forge talk (Post)
Is it possible like G-Code streaming processing (like FANUC or SIEMENS DNC Function )? Or Does anyone know the tips for CODESYS Motion to start moving long Long G-Code File quickly? I have to wait long time after "Start" button to start moving, I have to wait finishing interpreting whole G-Code file, ( and I have to prepare huge buffer to store. ) Now, I'm working on my CNC Project using SMC_ReadNCFile2, and SMC_NcInterpreter to preprocess G-Code. I tried to set SMC_Interpolator.xExecute to true to Start while after SMC_NcInterpreter processed more 50-line of G-Code, but that not worked, I had to wait SMC_NcInterpreter processed all lines to start SMC_Interpolator. G-Code have about 2000 lines of XY of G01 (or more over.. ) of short segment that a CAM software has exploded from NURBS Curve.
Last updated: 2024-05-03

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Update: I started over. I saved progress at each step. all compiled zero errors, zero warnings. Pre-processor messages remain, but I can make progress. Until I try to re- load the project file in Codesys. Re-loaded files error as above when compiled, even though they compiled error-free immediately before saving. Is my installation borked? (Not easy to re-install due to IT madness...)
Last updated: 2024-05-03

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
It is either my installation is bad, or there is a bug. I re-created the project in 3.5 SP19 and there are no errors or warnings. Compiles with no errors or warnings. The original was done in 3.5 SP20. Thoughts?
Last updated: 2024-05-03

CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Thread)
CODESYS control for Raspberry Pi 64 SL errors
Last updated: 2024-05-03

suggestion: collapse Ladder networks similar to Siemens' TIA Portal CODESYS Forge talk (Thread)
suggestion: collapse Ladder networks similar to Siemens' TIA Portal
Last updated: 2024-05-03

Post by tiagomachado88 on suggestion: collapse Ladder networks similar to Siemens' TIA Portal CODESYS Forge talk (Post)
Hello, It's just a suggestion to facilitate viewing and monitoring! Regards, Tiago
Last updated: 2024-05-03

Post by garrian on How to sort JSON object in codesys CODESYS Forge talk (Post)
Hi there, I'm testing out MQTT from my Wago PLC using JSON object. I have managed to publish this {"Temperature":15.6,"Setpoint":38.0} to my broker. Now I', trying to subscribe to the same message. The result is this: '{"Temperature":15.6,"Setpoint":38.0}95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' First, why do I see 95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' at the end of the message? Second, how Can i sort out this data to use it in my program? I followed a youtube tutorial which gave me the attached result, which works. But I need some other smart way of doing this when the object gets even more data in it. Any help is very appreciated :)
Last updated: 2024-05-04

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
Last updated: 2024-05-04

Post by hezhikui on Kalman Filter CODESYS Forge talk (Post)
hi,Matteo i find an article,it maybe helpful. see the attachement Hezk
Last updated: 2024-05-05

Kalman Filter CODESYS Forge talk (Thread)
Kalman Filter
Last updated: 2024-05-05

How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Thread)
How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ?
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Thread)
How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ?
Last updated: 2024-05-05

Post by kblundy on Change the Opening Position of the Dialog using VU.FbOpenDialog CODESYS Forge talk (Post)
I hope the community can help me with this. I need to use the Visu Utils FbOpenDialog to control the opening and closing of a dialog. I have the Opening and Closing working, but I can’t get the dialogue's position to be controlled. The code looks like this: PROGRAM OPEN_DIALOG VAR xOpenLatchSettingDialog : BOOL; TopLeftDialog : VisuStructPoint ; fbOpenLatchSettingsDialog : VU.FbOpenDialog ; END_VAR IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog:= FALSE ; TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog(sDialogName := 'visu_AlarmLatchSettings', xExecute := xOpenLatchSettingDialog , xModal := TRUE, itfClientFilter := VU.Globals.OnlyTargetVisu, pTopLeftPosition := ADR(TopLeftDialog)); CloseVisuDialog(sDialogName:= 'visu_AlarmLatchSettings'); ELSE xOpenLatchSettingDialog:= TRUE ; IF fbOpenLatchSettingsDialog.xError THEN xOpenLatchSettingDialog := FALSE; END_IF END_IF I can't seem to work out a way to make the values in TopLeftDialog.iX and TopleftDialog.iY be passed correctly in the call and for it to change the position of the dialogue box. The code is compiled, but the position has not been changed. Any guidance or suggestions for revising this code would be incredibly valuable. Your insights could be the key to solving this issue.
Last updated: 2024-05-05

Post by corriibme on Profinet IO-link master - IODD files CODESYS Forge talk (Post)
I am having the same problem right now. Could you please share more information if you were able to solve the problem?
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

<< < 1 .. 842 843 844 845 846 .. 888 > >> (Page 844 of 888)