Difference between CODESYS Control RTE x64 and CODESYS Control RTE V3 x64
CODESYS Forge
talk
(Thread)
Difference between CODESYS Control RTE x64 and CODESYS Control RTE V3 x64
Last updated: 2021-05-10
Migrate from Codesys WIN 32 bit to Codesys RTE 64 bit
CODESYS Forge
talk
(Thread)
Migrate from Codesys WIN 32 bit to Codesys RTE 64 bit
Last updated: 2015-12-15
Is it possible to simulate the codesys visualizations without project file/codesys?
CODESYS Forge
talk
(Thread)
Is it possible to simulate the codesys visualizations without project file/codesys?
Last updated: 2018-10-10
Identifier ioConfigConnector not defined. CODESYS IDE V3.5SP6 corruption after installation of CODESYS IDE V3.5SP10
CODESYS Forge
talk
(Thread)
Identifier ioConfigConnector not defined. CODESYS IDE V3.5SP6 corruption after installation of CODESYS IDE V3.5SP10
Last updated: 2017-10-20
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
CODESYS Forge
talk
(Thread)
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
Last updated: 2021-10-18
Codesys sales and support. Is it true that Codesys wants to get more customers?
CODESYS Forge
talk
(Thread)
Codesys sales and support. Is it true that Codesys wants to get more customers?
Last updated: 2023-07-03
how to convert library from CodeSys 2.3 to CodeSys 3.x ?
CODESYS Forge
talk
(Thread)
how to convert library from CodeSys 2.3 to CodeSys 3.x ?
Last updated: 3 days ago
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by iliyatsukerman on SoftMotion auf PFC200
CODESYS Forge
talk
(Post)
Hallo, Wir würden Ihre Unterstützung bei der Überprüfung der Kompatibilität der folgenden Konfiguration sehr schätzen: • PSTR-LO-16/400FEV ELMO • SCALANCE XC208 • WAGO PFC200 750-8213/40-010 • Die SPS (WAGO) wird gleichzeitig eingesetzt als: o EtherCAT-Master zur Kommunikation mit einem Elmo-Servoantrieb (EtherCAT-Slave, 4 Achsen – generisches CiA 402-Profil), und o Modbus-TCP-Server zur Kommunikation mit einem Siemens Modbus-TCP-Client, welcher zur Fernsteuerung des Elmo-Servoantriebs über die SPS dient. Bitte bestätigen Sie, ob die SPS in der Lage ist, diese Dualfunktion — als EtherCAT-Master und gleichzeitig als Modbus-TCP-Server — ohne Konflikte oder Performanceprobleme zu unterstützen. Insbesondere interessiert uns, ob die CODESYS SoftMotion SL Basislizenz (2305000000-F) notwendig ist, um 4 Servoachsen zu steuern, und ob diese Lizenz auf einer WAGO PFC200 SPS mit CODESYS Version 3.5 Service Pack 19 Patch 40 oder höher unterstützt wird. Alle Achsen im Servoantrieb werden unabhängig voneinander gesteuert. Mit freundlichen Grüßen. ILIYA
Last updated: 2025-07-13
Post by francescoc on Custom log CmpLog
CODESYS Forge
talk
(Post)
Hi, I am trying to create a log in my application. Since I cannot find any documentation regarding modifying the codesys configuration file to be able to log in ms, i tried to create a new log via CmpLog.LogCreate. Below is the part of the code where I create the logger and write a test string. In the log tab of codesys I actually see the new log that was created, but it is empty, and in the folder I cannot find any files. I can't find any detailed documentation. Can you guys give me support? Are there any examples? Thank you IF NOT FirstCycle THEN LogName:= 'LOGS/TestLog'; LogOptions.bEnable:= 1; LogOptions.iMaxEntries:= 5000; LogOptions.iMaxFiles:= 100; LogOptions.iMaxFileSize:= 5000; LogOptions.szName:= LogName; LogOptions.uiType:= CmpLog.LogTypes.LT_TIMESTAMP_RTC_HIGHRES; LogOptions.uiFilter:= CmpLog.LogClass.LOG_ALL; LogHandle:= CmpLog.LogCreate(pOptions := ADR(LogOptions), pResult:= ADR(Result)); LogHandle:= CmpLog.LogOpen(pszName:= LogName, pResult:= Result); Component_Manager.CMAddComponent2('TestLogNEW', 16#00000001, ADR(udiCmpIdNEW), 0); CmpLog.LogAdd2(LogHandle, udiCmpIdNEW, CmpLog.LogClass.LOG_INFO, 1, 1, 'Logger started...'); END_IF IF TestWrite THEN TestWrite:= FALSE; CmpLog.LogAdd2(LogHandle, udiCmpIdNEW, CmpLog.LogClass.LOG_INFO, 1, 1, 'Write test'); END_IF
Last updated: 2024-03-16
Post by paro on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, Problem in your code is that you are not calling the ClientFb cyclic. Please look at the Example from CODESYS: https://forge.codesys.com/prj/codesys-example/modbus/home/Home/ Your code works if the client fb is called cyclic! IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=Ethernet.IPAddress, uiPort:=502); // configure clientSerial clientSerial(iPort:=SysCom.SYS_COMPORT2, dwBaudRate:=SysCom.SYS_BR_115200, byDataBits:=8, eParity:=SysCom.SYS_EVENPARITY, eStopBits:=SysCom.SYS_ONESTOPBIT, eRtuAscii:=ModbusFB.RtuAscii.RTU); // configure clientRequestReadCoils_1 clientRequestReadCoils_1(rClient:=clientTcp, uiUnitId:=42, udiTimeout:=TO_UDINT(T#10MS)); // configure clientRequestWriteSingleRegister clientRequestWriteSingleRegister(rClient:=clientTcp, uiUnitId:=43, udiTimeout:=TO_UDINT(T#10MS)); // configure clientRequestReadCoils_2 clientRequestReadCoils_2(rClient:=clientTcp, uiUnitId:=44, udiTimeout:=TO_UDINT(T#10MS)); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=44, udiTimeout:=TO_UDINT(T#10MS)); END_IF // call the client FB's clientTcp(); clientSerial(); // call client request FB's clientRequestReadCoils_1(rClient:=clientTcp, xExecute:=TRUE, uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataCoils_1[0])); // for more details see Example_TCP, especially ClientRequest control (xExecute, xDone, xError). IF clientRequestReadCoils_1.xDone THEN // get data from aDataCoils_1 ... END_IF clientRequestWriteSingleRegister(rClient:=clientTcp, xExecute:=TRUE, uiItem:=3, uiValue:=123); clientRequestReadCoils_2(rClient:=clientTcp, xExecute:=TRUE, uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataCoils_2[0])); clientRequestReadInputRegisters(rClient:=clientTcp, xExecute:=TRUE, uiStartItem:=16, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0]));
Last updated: 2024-05-29
Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Thread)
Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
Last updated: 2023-08-26
CODESYS Automation Server Connector for 3.5 SP11
CODESYS Forge
talk
(Thread)
CODESYS Automation Server Connector for 3.5 SP11
Last updated: 2023-08-30
Introductory short video series on PLC programming (CODESYS)
CODESYS Forge
talk
(Thread)
Introductory short video series on PLC programming (CODESYS)
Last updated: 2023-08-28
Network Variable List in Codesys 3.5 on CAN
CODESYS Forge
talk
(Thread)
Network Variable List in Codesys 3.5 on CAN
Last updated: 2023-08-05
How to read structure in CodeSys using pythong script?
CODESYS Forge
talk
(Thread)
How to read structure in CodeSys using pythong script?
Last updated: 2017-10-09
Barcode-Reader O2I (TCP/IP) mit Codesys auslesen
CODESYS Forge
talk
(Thread)
Barcode-Reader O2I (TCP/IP) mit Codesys auslesen
Last updated: 2018-04-01
Compiling CoDeSys project using the command line interface
CODESYS Forge
talk
(Thread)
Compiling CoDeSys project using the command line interface
Last updated: 2021-01-27
CodeSys v3 Vendors/PLCs with C-Integration
CODESYS Forge
talk
(Thread)
CodeSys v3 Vendors/PLCs with C-Integration
Last updated: 2018-03-05
General question about Codesys and control RTE
CODESYS Forge
talk
(Thread)
General question about Codesys and control RTE
Last updated: 2020-01-27
Using ScriptEngine in C# for Creating Codesys Project
CODESYS Forge
talk
(Thread)
Using ScriptEngine in C# for Creating Codesys Project
Last updated: 2019-06-24
Newbie questions regarding CodeSys V3 Modbus RTU
CODESYS Forge
talk
(Thread)
Newbie questions regarding CodeSys V3 Modbus RTU
Last updated: 2016-06-09
Codesys Wago Going Online from Different Computer
CODESYS Forge
talk
(Thread)
Codesys Wago Going Online from Different Computer
Last updated: 2022-12-15
Adding a CANBUS device on Codesys Control Linux SL
CODESYS Forge
talk
(Thread)
Adding a CANBUS device on Codesys Control Linux SL
Last updated: 2022-05-25
CODESYS Control Not Showing Up in Devices
CODESYS Forge
talk
(Thread)
CODESYS Control Not Showing Up in Devices
Last updated: 2023-01-02
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.