Post by toby on Ethernet/IP communication with Omron NX1P2
CODESYS Forge
talk
(Post)
Hey guys, I'm very much a noob with networking, it's my achillies heel, and this is my first networking project using Ethernet/IP. Any help offered is GREATLY appreciated. I'm trying to network a Codesys Project with an Omron NX1P2 PLC. I'm using EIP due to hardware restrains. I've added the fieldbus, EIP scanner (as the master), and made a Network Variable List. On the Sysmac Studio end, I've made the variables and set them to network inputs/outputs, registered them in EIP settings, but when I try to set the target device (the Codesys project), I suspect I need to import an EDS file for the EIP mapping. Back in the Codesys project, I'm not sure how to: - Make an EDS file to share with Sysmac Studio - How to link the target device (Omron PLC) to the EIP fieldbus - How to map the inputs from the Omron PLC. Im sorry for my very open request for help, i'm kind of lost looking through the various forums/video/tutorials as many of them dont match what im trying to do. Any help, or sample programs would be so so greatly appreciated. If you need any further clarifications, please feel free to ask. Thanks in advance, Toby
Last updated: 2024-01-24
Post by danieldiaz on Problem with FB execution
CODESYS Forge
talk
(Post)
Hello everyone, I've been working on a system which needs an error function, with this purpose I've created a FB programmed in LD, after debugging I run the simulation. It seems that the variable linked to a coil doesn't change the value when the contacts are associated to input variables. When I use internal variables the logic works properly. I don't know if the problem is related to the variables definition or with the logic program. As you can see in the image, I1 and I2 are variables declared on the FB, the rest are input variables. If I force the eStop and Reset signals to TRUE the coil value should change, but it doesn't. However in the second network if I1 is TRUE the coil change to TRUE as it has to be. To sum up, my doubt is why that coil doesn't change its value? I would like someone to shed a light on this. Thanks!
Last updated: 2024-04-02
Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh
CODESYS Forge
talk
(Post)
Hi, I was hoping I could send the two files "application.app" and "application.crc" directly to the directory "/home/codesys/PlcLogic/Application" instead of logging into the device with codesys, downloading the program to the controller and then do the "create boot application", so it will reboot with the correct program running. I think i also need to edit the file "eRUNTIME.cfg" located in the "/home/codesys/ folder, because when I create the boot application from the codesys IDE, these lines are added to the file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app=0x212520, 0x2DBC747E, 2DBC747E.app I think the "eRUNTIME.cfg" file is the same as CODESYSControl.cfg I also dont know the purpose of the hexadecimal numbers etc. that is generated. When I tried to replicate what codesys was doing, I placed the same files in the same folder as when codesys generated the boot file. And also added the lines in the eRUNTIME.cfg file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app The controller did not boot up with any program, so my method did not work at all. I guess these lines tells the controller to run an application and where to find it? Could any of you help me with the best way to get the compiled program to the controller without using codesys or wago-software?
Last updated: 2024-05-28
Post by mil581 on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Hello everyone! I'm facing a weird issue with CODESYS Control Win V3 x64 on a fresh Windows install. The situation is as follows: CODESYS Modbus TCP Server (Slave) is running and I can see live values in the mapping display of Modbus settings: GVL (e.g., 32, 42, 50). Port 502 is LISTENING according to netstat. When connecting via Modbus Poll or Node-RED, the connection status changes to ESTABLISHED and everything reports as fine. The Problem: Despite the successful connection, all holding registers return 0 no matter what. It's like the OS accepts the TCP handshake, the request counter goes up but the data payload never reaches Modbus Client (in this case Node-RED or Modbus Poll). Quick Stats: Firewall: Completely OFF. Unit ID: Verified & Matching. IP: Tried 127.0.0.1 and 192.168.0.1. Interface: Correctly bound in Ethernet Device settings. I already tried absolutely everything from changing IP address, subnet, port, deleting the project and starting new one and even nuking my old Windows install. Since I am near completion of my bachelor thesis only thing left for me to do is connect SoftPLC to NodeRED via Modbus but this issue is driving me crazy for weeks. I do not know what to do anymore.
Last updated: 2025-12-25
Post by yannickasselin on Lenze i950 Servo and WAGO PFC200
CODESYS Forge
talk
(Post)
I don't have time to go through the whole manual but as I said earlier, the servo drive does not support any of the modes needed for SoftMotion Light to work. If you want to use the full SoftMotion, you could use SMC_Homing function block to do the homing. This function block does not use the Homing Mode. It still uses the CSP mode and does the logic in Codesys runtime instead of in the servo drive. Read the documentation about it to see if it fits your needs. But if your controller only supports SoftMotion Light, I am afraid you will not be able to use the i950. I do a lot of motion stuff with different servo brands. Some support all the modes needed for SoftMotion Light and some don't. You really need to make sure the modes are supported before choosing a brand over another. I tend not to use brand specific controllers in order not to be limited by their supported features. I usually choose a PC (Linux or Windows) and install the Codesys runtime and licences myself. This is the most flexible way to use Codesys in my opinion. Depending on how many axes are needed in your project, a full SoftMotion license may not be more expensive than SoftMotion Light because SoftMotion is available as Application based license whereas SoftMotion Light is not. But of course, SoftMotion is harder on the CPU than SoftMotion Light.
Last updated: 2026-02-13
Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Thread)
Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
Last updated: 2023-08-21
How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Thread)
How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
Last updated: 2023-08-28
When Keyboard Key is in Hold, then Webvisu is extreme slow and latent
CODESYS Forge
talk
(Thread)
When Keyboard Key is in Hold, then Webvisu is extreme slow and latent
Last updated: 2023-09-20
Bug in LD/FBD editor - ModbusFB.ClientRequest does not show ETrigTo-inherited variables
CODESYS Forge
talk
(Thread)
Bug in LD/FBD editor - ModbusFB.ClientRequest does not show ETrigTo-inherited variables
Last updated: 2022-12-04
Linie mit einem variablen P. sowie Rechteck nur in x-wachchs
CODESYS Forge
talk
(Thread)
Linie mit einem variablen P. sowie Rechteck nur in x-wachchs
Last updated: 2013-10-11
How do I list the folder names found in a PLC Directory?
CODESYS Forge
talk
(Thread)
How do I list the folder names found in a PLC Directory?
Last updated: 2015-05-07
how to run the machine using CNC editor in codesys
CODESYS Forge
talk
(Thread)
how to run the machine using CNC editor in codesys
Last updated: 2007-10-24
Aufrufen von Scripten (Python) aus CODESYS. Beschreiben von globalen Variablen in Codesys durch Script
CODESYS Forge
talk
(Thread)
Aufrufen von Scripten (Python) aus CODESYS. Beschreiben von globalen Variablen in Codesys durch Script
Last updated: 2017-09-10
Read values in V3.5 SP9 Patch 5 vs V3.5 SP13 Patch 2
CODESYS Forge
talk
(Thread)
Read values in V3.5 SP9 Patch 5 vs V3.5 SP13 Patch 2
Last updated: 2019-02-11
How to intercept a variation in the RetainPerstist variables (for saving to file)
CODESYS Forge
talk
(Thread)
How to intercept a variation in the RetainPerstist variables (for saving to file)
Last updated: 2018-08-03
Is it possible to replace a table row header for a text in a text list?
CODESYS Forge
talk
(Thread)
Is it possible to replace a table row header for a text in a text list?
Last updated: 2021-10-21
Modbus TCP - no values in BeagleBone IEC 61131-3 control engine
CODESYS Forge
talk
(Thread)
Modbus TCP - no values in BeagleBone IEC 61131-3 control engine
Last updated: 2016-12-14
How to set "Always updatevariables" to "enable 2" by default in DeviceDescription.
CODESYS Forge
talk
(Thread)
How to set "Always updatevariables" to "enable 2" by default in DeviceDescription.
Last updated: 2020-12-10
"Update boot project" is default unchecked by login in V3.5 SP14 Patch1
CODESYS Forge
talk
(Thread)
"Update boot project" is default unchecked by login in V3.5 SP14 Patch1
Last updated: 2019-04-22
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
Should I be looking for anything in particular in the PLC Log? Attached is the xml file from the PLC logger.
Last updated: 2023-09-26
AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030
CODESYS Forge
talk
(Thread)
AlarmMgr Database Error in method WriteToStorage: Error code = 30531, Action = 1030
Last updated: 2023-11-21
Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Thread)
Codesys Communication Manger - Required information model version exists in the model repository but is not found
Last updated: 2024-06-28
Data Sources Manager causing exception due to float or double type in OPC server
CODESYS Forge
talk
(Thread)
Data Sources Manager causing exception due to float or double type in OPC server
Last updated: 2024-07-01
Post by thommy54 on CODESYSControl_User cfg richtig konfigurieren
CODESYS Forge
talk
(Post)
Und was ist mit dem Abschnitt [SysFile] ? Kann der sowohl in der /etc/CODESYSControl.cfg als auch in der /etc/CODESYSControl_User.cfg vorhanden sein ???
Last updated: 2024-07-02
The current baud rate could not be determined in CR0020 IFM with maintenance tool
CODESYS Forge
talk
(Thread)
The current baud rate could not be determined in CR0020 IFM with maintenance tool
Last updated: 2024-07-09