Post by george32 on Readable IO names CODESYS Forge talk (Post)
Hello Folks, I have a quite basic understanding of how PLC programming works. However I keep getting stuck on 1 problem I could not get my head around. The problem is as follow: I have a PLC with 60 IO (20 inputs, 40 outputs). Each IO is defined as a function block. Furthermore I have an external IO card connected trough a CanBus connection. This IO card has 4 analog input channels (USINT), 4 digital inputs (Bool) and 4, digital outputs (Bool) Because I have 2 different components which both has data have I made 4 arrays to store the data off every component in one variable. PLC_Input: Array [1..20] of BOOL; PLC_Output: Array [1..40] of BOOL IOCard_Input: Array [1..8] of BOOL IOCard_Output: Array [1..4] of BOOL Because the control and reading of the different in and outputs is done by a TCP connection I want to use some kind of enumeration or struct to give each index a name so that my main would be a little bit more readable instead of all the magic numbers. Also this would make my program more dynamic for the furter in case I need to changes some in the IO nummers. For example: pump is placed on the fysical terminal strip number place 54, which is the 3th output of the IO card in the program: if I am sending a message with value 54 I would like to control IOCard_Output[3]. If there is a solution or methode to get this done, I can eventually do the following in my main program: IOCard_Output[Pump]. I have tried the following: IOCard_Output[Pump - 51] with an enumration but this keeps raising an error I hope some of you could help me further with this problem. In gross lines: I want to couple all the different IO to a more readable name and this readable name should control the right Array index Thanks in advance, George
Last updated: 2024-09-26

Post by hclai on Maximum Array Index Issue CODESYS Forge talk (Post)
I was trying to use a table object in visualization. I want to dynamically show the valid rows in the table. However, it does not work when there is 1 row. i put the maximum array index to 1. it does not show the 1st row. when i change to 2, it show the second row only. my project with older visualization profile version is working perfectly fine. I did some test and realized that i must use a Row Selection variable to change from 0 to 1. With this change of Row selection, then the row 1 will show up.
Last updated: 2025-06-19

Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64 CODESYS Forge talk (Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25

Post by smeitink on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module CODESYS Forge talk (Post)
Hi all, I'm looking for help with an issue I've come across while trying to facilitate Modbus communication between a WAGO PFC200 PLC using a 750-652 communication module and an iEM2050 Series Single Phase Energy Meter. I believe to have everything wired and setup correcty, but I keep running into a "Error time out" message, and by now I don't really know what else to try. My setup is as follows: A PFC200 Wago PLC, which has 2 750-652 Serial Interfaces extension modules connected to its field bus. I'm using one of these to talk to a Schneider iEM2050 - kWh-meter over modbus. I have connected terminal 23 (A) of the iEM2050 to connector 6 (A) on the 750-652. I have connected terminal 24 (B) of the iEM2050 to connector 2 (B) of the 750-652. I'm using 200mm of twisted together wires to connected them both, and I have placed a 120 ohm resistor between A and B at both ends. I've attached relevant pinout images to this post. I then wrote a simple program that configures the Mobus port, as per the datasheet of the iEM2050. You can find an image of the relavent page attached to this post too. This is my program: PROGRAM PLC_PRG VAR Master: FbMbMasterSerial; xIsConnected: BOOL; xError: BOOL; iIndex: INT := 1; xTrigger: BOOL; utQuery : typMbQuery := ( bUnitId := 1, // The Modbus unit or slave address bFunctionCode := 4, // Function code for reading input registers uiReadAddress := 1829, // adress for the Power on off counter uiReadQuantity := 1 // Quantity of registers to read ); iStep: INT; oStatusModbus: WagoSysErrorBase.FbResult; utResponseModbus: typMbResponse; xConnect: BOOL := FALSE; delayTimer: TON; END_VAR Master( xConnect:= xConnect, I_Port:= _750_652_24_1, udiBaudrate:= 9600, usiDataBits:= 8, eParity:= WagoTypesCom.eTTYParity.Even, eStopBits:= WagoTypesCom.eTTYStopBits.One, eHandshake:= WagoTypesCom.eTTYHandshake.None, ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485_HalfDuplex, xIsConnected=> xIsConnected, xError=> xError, oStatus=> oStatusModbus, eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU, tTimeOut:= T#5S, utQuery:= utQuery, xTrigger:= xTrigger, utResponse:= utResponseModbus); delayTimer(IN := TRUE, PT := T#3S); // Use the Q output of the timer to set xConnect after the delay IF delayTimer.Q THEN xConnect := TRUE; END_IF CASE iStep OF 0: //Wacht totdat de master de poort geopend heeft IF xIsConnected THEN iStep := 1; END_IF 1: //Stuur request naar de slave xTrigger := TRUE; iStep := 2; 2: //Wacht totdat de master klaar is met het afhandelen van de request IF NOT xTrigger THEN iStep := 3; END_IF END_CASE The TON delay before opening the port is due to a an error I encountered when opening it straight away. This seems to be a bug, as described here. However, the TON solved that particular issue. I tried reading multiple registers, but like I said, I still always end up with the "Error time out". What else can I test or try at this point?
Last updated: 2024-02-24

Post by trusty-squire on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
Here, it seems to me that we are getting completely off track with the observed problem. If questions clarifying the details of the installation are problematic, it's best to include those details in the original question then... I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. Testing the full program in emulation is entirely different from creating a simplified program to isolate the function causing problems in the real world. I would recommend trying it to isolate the issue. The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem A simple "yes" is the correct answer to my question here... Anyways, you seem to be a very knowledgeable expert, good luck on your problem!
Last updated: 2025-01-18

Post by dtamm on How to read string from CharBufferPtr? CODESYS Forge talk (Post)
I am trying to implement a mechanism to send alarm SMS. For this, I have created an Alarm Class with a Notification Action which calls a POU. This POU implements IAlarmNotifiable making it selectable in the Alarm Class configuration. IAlarmNotifiable has an Execute method which is called by the alarm class. Now, I want to extract the alarm message of the triggered alarm. The Execute method comes with a VAR_INPUT itfAlarm: AlarmManager.IAlarm which supplies a method called GetMessage. The help text says: Returns the message text, that has been configured for the alarm. The result is a pointer to the buffer, where the message text is stored The type of the result is CharBufferPtr, and at some place I read that it can be interpreted as a pointer to string. But I cannot manage to extract the alarm message, all I get are numbers. I have tried the following: psAlarmText := itfAlarm.GetMessage(__SYSTEM.TYPE_CLASS.TYPE_STRING)^; sAlarmText := TO_STRING( itfAlarm.GetMessage(__SYSTEM.TYPE_CLASS.TYPE_STRING)^ ); So how do I get access to the alarm message as clear text? (In this case, "Larm 1")
Last updated: 2024-02-21

Post by william-blandon on RecipeManCommands.ReloadRecipes CODESYS Forge talk (Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23

Post by simone on Collapse all CODESYS Forge talk (Post)
Hi, I'm wondering if it exist a button or a keyboard shortcut (much much better) for "collapse all" the open folder on a codesys project. It would really be nice to have. Also: Are there some options or configuration for set a default zoom for the different editor (or even one global), for example I would like to have 100% on ST, LD editor and have 80% on Visualization Editor; and also have a button to set all the zooms to default, now it seems that every file mantain the one previously set. I'm working with the 3.5.20.10 right now Thanks!
Last updated: 2024-11-21

Post by voffi on projects.open not working for file based storage project CODESYS Forge talk (Post)
Hello! Opening a project from a python script given at the CODESYS command line does not work for me with a file based storage project. Example: Running projects.open("test.project", primary = True) works but converting the project to a file based storage project and then give the folder name as an argument to project.open Running projects.open("test.fbsproj", primary = True) does not work. We decided to work with file based storage for the project. Is there a scripting API for file-based storage to e.g. convert it while running the script back or how to open file based storage project with projects.open? Thank you! voffi
Last updated: 2025-09-05

Post by sean-barton on Function block method default arguments CODESYS Forge talk (Post)
I have default arguments specified for function block methods but when calling a method, an error is produced requiring me to supply all the arguments despite there being default values. According to the online documentation, under section "Calling a Method" and subsection "argument passing" of the following link: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_obj_method.html "Passing an argument for an input ... can be omitted ... for which a default or initial value was specified in the declaration..." I have found this to be the case for all Codesys IDEs I've used, 3.5.11, 3.5.16, 3.5.17, 3.5.19. Am I missing something?
Last updated: 2023-12-21

Post by sushela on Latest Temu Coupon Codes [acq615756] All Users CODESYS Forge talk (Post)
Latest Temu Coupon Codes [acq615756] | All Users If you’re an avid Temu shopper or new to the platform, you’re in for a treat. Temu offers incredible savings with their latest coupon codes, and one of the hottest deals right now is the $100 off discount using the code [acq615756]. Whether you're placing your first order or are an existing customer, this coupon code is designed to offer fantastic value. In this article, we will explore all the benefits of using the Temu Coupon Code [acq615756], breaking it down into different categories to ensure you get the most out of this amazing offer. TEMU Coupon $100 Off for Existing Customers {[acq615756]} Existing customers on Temu can now enjoy a massive discount of $100 off their purchases. If you’ve been shopping on the platform for a while and are looking for a great deal, the [acq615756] code is perfect for you. It's rare to find such generous discounts for repeat customers, making this offer one not to miss. Apply the code at checkout and enjoy significant savings on your next order. TEMU Coupon $100 Off First Order {[acq615756]} If you’re new to Temu, there's an even better reason to start shopping now. By using the [acq615756] code, new users can save $100 on their very first order. This is an ideal way to explore the platform’s wide range of products without breaking the bank. Simply enter the code during your first purchase to redeem the discount. TEMU Coupon $100 Off Code {[acq615756]} The [acq615756] code is one of the most versatile coupon codes available. Whether you’re an existing user or a first-timer, this $100 off coupon can be applied to a broad range of products across the Temu platform. Just enter the code at checkout, and enjoy instant savings on your total. TEMU Coupon $100 Off for Existing Customers UK {[acq615756]} For our shoppers in the UK, the [acq615756] coupon code is a fantastic opportunity to save £100 off your next order. Existing customers can make the most of this discount when shopping from the UK. Whether you’re buying clothing, electronics, or household items, use the code at checkout to enjoy the discount and elevate your shopping experience. TEMU Coupon $100 Off New User {[acq615756]} New users on Temu have a golden opportunity to save big on their very first order with the [acq615756] coupon code. If you're hesitant to make your first purchase, this $100 off deal is a compelling reason to start now. With this code, you can buy more products at a reduced price, making your first shopping experience more rewarding. TEMU Coupon $100 Off for Existing Customers 2024 {[acq615756]} Looking for a way to save in 2024 as an existing customer? The [acq615756] code is here to help. This coupon provides an easy way for repeat shoppers to save $100 on any purchase. Make sure to take advantage of this deal throughout the year and enjoy continuous savings while shopping for your favorite products. TEMU Coupon $100 Off Code UAE {[acq615756]} Shoppers in the UAE can also benefit from the [acq615756] coupon code. Whether you are a new or existing customer, this $100 discount is applicable on your purchases. Be sure to apply the code during checkout and enjoy lower prices on a wide range of items available on Temu. TEMU Coupon $100 Off First Order Free Shipping {[acq615756]} In addition to saving $100 on your first order, Temu sweetens the deal by offering free shipping. Use the [acq615756] code when you make your first purchase and enjoy not only significant savings but also free delivery. It’s the perfect way to start shopping on Temu without any hidden costs. TEMU Coupon $100 Off for Existing Customers Free Shipping USA {[acq615756]} For our shoppers in the USA, the [acq615756] code offers an incredible $100 off your purchase, plus free shipping. Existing customers can benefit from this offer to save even more. Enjoy the convenience of home delivery without the extra cost, making your shopping experience smoother and more affordable. TEMU Coupon Code $100 Off + Free Shipping {[acq615756]} This coupon code [acq615756] is more than just a discount; it’s an all-in-one deal. With $100 off and free shipping combined, you can shop to your heart's content without worrying about shipping fees. This offer applies to all users, both new and returning, ensuring that everyone can enjoy amazing savings. TEMU Coupon $100 Off for Existing Customers Canada {[acq615756]} Canadian customers aren’t left out! Existing shoppers in Canada can use the [acq615756] coupon code to get $100 off their order. Temu continues to expand its presence, and this discount ensures that loyal customers in Canada can shop at discounted rates while enjoying a vast array of products. Conclusion The Temu Coupon Code [acq615756] is an exceptional opportunity for all users, offering $100 off across multiple regions, from the UK to the UAE, USA, and Canada. Whether you’re a new customer or have been shopping with Temu for a while, this code provides incredible value, ensuring that you save big on your next purchase. Don’t miss out on the added benefit of free shipping, and make sure to apply this code at checkout to maximize your savings. Start shopping now and take advantage of these amazing offers before they expire!a
Last updated: 2024-10-26

Post by alexgooi on Modbus TCP interface get stuck CODESYS Forge talk (Post)
Dear Forum, I'm currently experimenting with Modbus interfaces in combination with a virtual controller. I have the following setup (Modbus_Setup.png): I have an IPC with Debian installed on it (Debian 13). On this Debian machine I have installed a docker server and on this docker server a Codesys runtime container is deployed (Codesys_image.png). The Modbus scanner makes connection with and IO coupler and this works well. But when I physically disconnect the ethernet connection between the IPC and the IO coupler the Modbus interface gets stuck in a state where it gets stuck in the busy state (Modbus_Stuck.png). When I plug the cable back in, the IO coupler isn't communicating until the xBusy variable is manually set to False, after this action is performed the communication goes back to normal. I have tried to set the container network to host and bridge (Network.png), but both version gives the same result (stuck scanner). I would expect that the Modbus interface is generating a timeout after 1 sec, because this is how it is setup (Modbus_settings.png), but this is not what happens. I have thought to write a piece of code that writes xBusy to false when it is stuck but because it is an output I'm not able to write to it. I have tried this with another PC (different CPU/motherboard) but this gives the same outcome. I tried updating to the latest version of Virtual control (4.20) but this gives the same result. I also tried to do the same thing with an ethernet IP scanner, and this gives an error after the timeout is expired (so this works well). I have tried to connect to the IO coupler using the Modbus_FB lib (Modbus_FB.png) the FB's are giving the correct errors and behaving as expected. At last I have tried to use a Scanner on a Codesys controller (no IPC) and here the scanner behaves as expected (an alarm is triggered after the timeout has been expired). The version of the Codesys components are listed in the picture Versions.png Is there anyone that can give me a push in the right direction? Kind regards Alex
Last updated: 2026-04-14

Post by alex-at-xana on EThercat Dynamic configuration CODESYS Forge talk (Post)
Hi Everyone, For a fast monitoring system I am using Ethercat oversampling and timestamping inputs. As the customers has a lot of different configurations out in the field, we went for a dynamic Ethercat configuration. Already got the whole detection chain working but now I am stuck since two days in debugging the configuration. Here are my quesitons: I extended the dynamic config example for the EL3632 16#0E303052: //EL3632 pSlave^.SetDCSettings(TRUE,TRUE,80,80,TRUE,4000,0,0); pSlave^.AddSyncManager(16#1000,128,16#26,TRUE,3); pSlave^.AddSyncManager(16#1080,128,16#22,TRUE,2); pSlave^.AddSyncManager(16#1100,0,16#4,TRUE,1); pSlave^.AddSyncManager(16#1110,214,16#20,TRUE,0); pSlave^.AddFMMU(0,214,0,7,16#1110,0,1,1); pSlave^.AddFMMU(0,1,0,0,16#80D,0,1,1); xKnown := TRUE; This leads to a PLL Error for these devices. I double and triple checked the configuraton, but cannot find the issue. There seems to be one difference: the config dialog creates a startup parameter: 16#10F3:16#05, Name: Command_0, Value:0. Bitlen: 16, Stop on fault: false, jumpt at fault: false: next line: 0 a) I do not find information on how to set this in my code. Can you help me there? b) Without trying to set the value, I get a PLL error for these devices in the master log. Is the config wrong? c) Do I need to set the Master to Autoconfigure or Manual? I used autoconfigure for my tests. The stack creates input data addresses for the slaves input data range (pSlaves[i].InputData) which are different from those created when I use the Engineering tools dialogs to configure Ethercat. Specifically, the addresses seem to be aligned at 16 byte boundaries when they are created using the engineering tool, but may appear at uneven addresses when I use the script in dynamic config. I did not try to access ULINT at uneven addresses yet, but I am suspecting this may be a problem. Do I need to manually align the addresses ? Any help is appreciated...
Last updated: 2024-09-10

Post by kunal-pinetics on USB Communication for IP Configuration & Application Update – STM32H Series PLC CODESYS Forge talk (Post)
Hello everyone, I am currently working on a PLC device based on the STM32H series MCU, running CODESYS. At the moment, I can: Change the Ethernet IP address Update/download the PLC application via Ethernet without any issues. However, I would like to implement the same functionality over USB (or Serial via USB) instead of Ethernet. My goals are: Change the device’s Ethernet IP address via USB Download/update the PLC application via USB communication Possibly use USB as a service/programming interface The hardware platform is based on STM32H series, and I am looking for guidance on: Whether CODESYS supports USB device communication for runtime download If a custom USB CDC (Virtual COM Port) implementation is required Whether a specific CODESYS runtime configuration is needed If a bootloader approach is recommended for application updates via USB If anyone has experience implementing USB communication for runtime download or device configuration on an STM32-based PLC, I would really appreciate your guidance. Thank you in advance for your help.
Last updated: 2026-02-26

Temu Coupon Code for 40% Off [[acq615756 "OR" act906655]]: For Both New And Existing Customers CODESYS Forge talk (Thread)
Temu Coupon Code for 40% Off [[acq615756 "OR" act906655]]: For Both New And Existing Customers
Last updated: 2024-10-26

How to download dependencies packages for CODESYS Control for Raspberry Pi SL ? CODESYS Forge talk (Thread)
How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
Last updated: 2025-06-23

Buyer guide for first robot arm and need of general tips for beginner. CODESYS Forge talk (Thread)
Buyer guide for first robot arm and need of general tips for beginner.
Last updated: 2021-01-25

Support for Compute Module 4s (CM4s) with CODESYS Control for Raspberry Pi MC SL CODESYS Forge talk (Thread)
Support for Compute Module 4s (CM4s) with CODESYS Control for Raspberry Pi MC SL
Last updated: 2023-06-30

Looking for a good rugged HMI (5'' inch display) for mobile applications CODESYS Forge talk (Thread)
Looking for a good rugged HMI (5'' inch display) for mobile applications
Last updated: 2018-08-31

Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5) CODESYS Forge talk (Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28

Post by ivanj on Codesys V3 + Rpi + PCA9685 + two robot arms CODESYS Forge talk (Post)
greetings to everyone I have a system consisting of rpi3 computer with codesys v3 installed connected to one pca9685 through which the servo motors of the two robotic arms are connected (each robot arm has 6 motors) I managed to get that the pca9685 can only drive 4 servos on the first arm the other 2 on the same robot arm do not respond, nor do the remaining 6 they do not react on the other robotic arm. Power is connected to the pca9685 for motors of sufficient power or amperage. I tried to put another pca9685 but the same thing happens again. What is the possible problem?
Last updated: 2024-10-02

Post by fless on Warning C0564 when compiling CNC project with variables program CODESYS Forge talk (Post)
Update: We managed to avoid the warnings by changing the order of initialization by adding an attribute to the GVL with the variables. {attribute 'global_init_slot' := '49989'} The variables are initialized right before the regular GVLs (default GVL slot 49990). Note to Codesys: I see the problem, Codesys needs to initialize the CNC objects before the GVLs so they can be used in the GVL. But then you can't use variables from GVLs in CNC programs. Maybe you could disable the warning in your generated CNC objects? At least a note for a workaround would have been nice.
Last updated: 2024-04-02

Post by gseidel on CAM Motion Recover after STO CODESYS Forge talk (Post)
Dear Mr. Kolev, I'm not sure I understood correctly. But this is my take on your question: When the STO of the slave is triggered, store the current master position (e.g. 225 units) After the reset of the slave error, call MC_SetPosition on the virtual master and reset it to the stored position (225 units) Optionally, before MC_CamIn is restartet, move the slave back to the slave position corresponding to the stored master position. (If you do this, no ramping in will be necessary) Restart MC_CamIn, with absolute master position and absolute slave position. Choose the StartMode that is appropriate for your machine. Best regards, Georg Seidel
Last updated: 2026-02-16

Post by imdatatas on Auto Declare window disappears by itself in the Ladder editor CODESYS Forge talk (Post)
Hello Everyone, The "Auto Declare" window disappears by itself in the Ladder editor. For example, a new function block is wanted to be added to the Ladder editor. (For example; MC_Jog block and instance name will be fbMcJog). To do this, "Empty box with EN/ENO" is added to the ladder line from the Toolbox on the right and when you type MC_Jog in the empty box and press enter, normally the "Auto Declare" window appears and you are expected to be asked to write the instance name here. However, this "Auto Declare" window closes itself immediately, it does not wait for the user to enter a value or close the window. I often encounter this situation in many IDE versions. Does this seem like a bug? If anyone has encountered a similar problem while creating a new program name, function or function block instance name regarding the "Auto Declare" window and knows a solution, I would be glad if you could share it. Best wishes Imdat
Last updated: 2025-03-06

Post by farren on How to stay in a method until something is finished. CODESYS Forge talk (Post)
I know I'm thinking about this wrong -- too many decades of procedural and event-driven programming and only a few months of PLC ST programming...... I've created a visualization with a button that when pushed calls a method. I want the method to take a pressure reading, wait one minute and then take another pressure reading. I'm looking for leaks. I'm using TON for the delay. It seems like what is happening is that the method gets called once and it takes the first reading and starts the TON. But then execution continues, leaves that method call, and the second reading never happens. I can force the method to keep running until the whole thing is done with a While loop, but I understand that is considered BAD in PLC programming. If it push the button again to call the method again, it picks up where it left off and if the timer is complete then it runs the remaining code. How do I keep that method running until it is complete with just one call without using a while loop that ties up the PLC for a minute? Thanks! -Farren
Last updated: 2025-10-31