Post by eschwellinger on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
CODESYS Forge
talk
(Post)
check with the CODESYS Installer er if you are on latest Visuversion. 4.9.1.0
Last updated: 2026-01-27
The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
CODESYS Forge
talk
(Thread)
The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
Last updated: 2026-01-27
Conversion of analogue input into Real measurement value
CODESYS Forge
talk
(Thread)
Conversion of analogue input into Real measurement value
Last updated: 2026-01-26
How to get SYM File on CodeSys 3.5
CODESYS Forge
talk
(Thread)
How to get SYM File on CodeSys 3.5
Last updated: 2026-01-27
Post by benwzd on How to get SYM File on CodeSys 3.5
CODESYS Forge
talk
(Post)
Hello, I am looking to obtain the SYM file on CodeSys please? this is to import into PCVue Thanks
Last updated: 2026-01-27
Post by gland on Open project automatic with correct version
CODESYS Forge
talk
(Post)
Goodmorning, The projects we have made (with several persons) are in differents versions, Codesys V3.5 sp18 patch4, V3.5 sp19 patch 2, V3,5 sp19 patch 5 etc V3.5 sp21 patch 3 etc.. Now when we're opening an project thats's not opend before on my pc and we're not sure in witch version it's made it's quite annoying. We don't want to update to the newest version. Is there a way that it's automatic opening the correct version? Is there a program/tool/easy way to do this? Thanks,
Last updated: 2026-01-27
Post by fleaplc on CPU + EtherCAT redundancy
CODESYS Forge
talk
(Post)
Hi all, for a new project I'm looking for a redundant controller with EtherCAT fieldbus I/O. Actually I'm using Beckhoff and it works great! but there's not a solid redundancy yet... Does someone get experience for industrial application (not raspberry) for a redundant Codesys system? If yes please share some info (CPU / OS type, bus, number of managed I/O,... and especially feeling feedback (stability, bugs, performance)... Every suggestion is kindly appreciated!! Fabrizio
Last updated: 2026-01-27
Post by fleaplc on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Did you check the communication with a sniffer ? (ex. Wireshark) to check if the holding get to zero by a wrong writing (client initialization?) o something else?
Last updated: 2026-01-27
Open project automatic with correct version
CODESYS Forge
talk
(Thread)
Open project automatic with correct version
Last updated: 2026-01-27
Mapping values with etherCAT mailbox communication
CODESYS Forge
talk
(Thread)
Mapping values with etherCAT mailbox communication
Last updated: 2026-01-27
Post by mattkaree on Mapping values with etherCAT mailbox communication
CODESYS Forge
talk
(Post)
I am using a WAGO PFC200 PLC as an etherCAT master and a Keyence IV3-G120 with DL-EC1A attached as an etherCAT slave. I am using CODESYS V3.5 SP21 Patch 3. I was able to set up mailbox communication and can see values changing accordingly, but I want to know how I can map these values and reference them in my program. I am able to map the process data objects in the 'EtherCAT I/O Mapping' tab, but there is no where to map the mailbox values in the 'CoE Online' tab. Is there a way I can reference one of these values in my code?
Last updated: 2026-01-27
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
I think I understand my problem. They are most probably related to configuration of the network. When I use DHCP for the unit to my router it all works. However when using static IP I have not managed to reach functioning state. Trying to replicate the situation on my desk. Having a static IP on the "debian host" and a connection to my computer which then routes traffic on to internet. I have entered settings for gateway and netmask. I can ping from my "debian plc host" to internet and also do "curl google.com" so traffic seems to find its way through and back, still "Automation server" will not find the gateway. Any hints how a manual configuration should be done? Is it possibly a "firewall" issue of my "normal router"? Thanks for any help! Per
Last updated: 2026-01-27
Finding out exception code position
CODESYS Forge
talk
(Thread)
Finding out exception code position
Last updated: 2026-01-27
The future and proper use of CAA.BOLT, CAA.SEMA,..
CODESYS Forge
talk
(Thread)
The future and proper use of CAA.BOLT, CAA.SEMA,..
Last updated: 2026-01-27
Auto Declare window disappears by itself in the Ladder editor
CODESYS Forge
talk
(Thread)
Auto Declare window disappears by itself in the Ladder editor
Last updated: 2026-01-27
Post by kambel on IO Drive on C manual
CODESYS Forge
talk
(Post)
Hello, pls help!!! Is there a more detailed manual (for dummies) for writing your own IO drive device in C? Another question: how can I add diagnostics to the IEC IO Drive device so that a red triangle lights up in the project tree in the event of a malfunction?
Last updated: 2026-01-29
Post by kambel on information security of CDS IDE 3.5.15.30
CODESYS Forge
talk
(Post)
Hello Please tell me if it is possible to hide information about devices in the Scan device window on pic.
Last updated: 2026-01-29
information security of CDS IDE 3.5.15.30
CODESYS Forge
talk
(Thread)
information security of CDS IDE 3.5.15.30
Last updated: 2026-01-29
Post by swol on Font Underline on webvisu not shown
CODESYS Forge
talk
(Post)
Over 5 years later - is this still current information?
Last updated: 2026-01-29
Font Underline on webvisu not shown
CODESYS Forge
talk
(Thread)
Font Underline on webvisu not shown
Last updated: 2026-01-29
Redundancy Codesys Runtime, Synchronization
CODESYS Forge
talk
(Thread)
Redundancy Codesys Runtime, Synchronization
Last updated: 2026-01-30
Post by ketanvaishnav on Redundancy Codesys Runtime, Synchronization
CODESYS Forge
talk
(Post)
i am facing same data sync issue. i am use two 750-8212 (FW30) controllers. datas are sync from active to standby during changeover time, but datas are not sync from standby to active.
Last updated: 2026-01-30
Post by timvh on CPU + EtherCAT redundancy
CODESYS Forge
talk
(Post)
It works well with two Wago 750-8210's. I helped a few customers setting this up. But it should work with any device which can control EtherCAT I/O, is real-time and has sufficient network interfaces. Two network adapters can be used to create a redundant EtherCAT network (you need 2 additional switches for this). The other network adapters can be used to interconnect the 2 PLC's (synchronization). We noticed that if you exchange variable lists that there could be some issues if you have long lists. So what we did is use a SoftPLC on a server that contains all the settings which continuously sends network packages (GVL sender) and which is received by both PLC's (network receiver). Switching over is done in milliseconds. The bus doesn't notice the change-over. EtherCAT communication works flawlessly.
Last updated: 2026-01-30
Post by yoeri on Python Scripted Save_Archive with noUI
CODESYS Forge
talk
(Post)
Is there any update on this? Running codesys 3.5.19.70 proj = projects.open(project_path, primary=True, update_flags=flags) This gives an error only when using --noUI exception System.NullReferenceException: Traceback (most recent call last): File "C:\Project\ci\build.py", line 14, in <module> SystemError: Object reference not set to an instance of an object. Exit code: 1</module>
Last updated: 2026-01-30
Python Scripted Save_Archive with noUI
CODESYS Forge
talk
(Thread)
Python Scripted Save_Archive with noUI
Last updated: 2026-01-30
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.