Post by naduley on Multiple Branches
CODESYS Forge
talk
(Post)
I am trying to create multiple branches in my project and I keep getting gaps in the ladder logic "wiring". I'm not sure if this is a graphical error or something else but every thing I've tried to do to correct it does not work. Has anyone else run into this or know how to correct it?
Last updated: 2025-06-04
Post by zoppp on Visu Frame-configuration___text will not work
CODESYS Forge
talk
(Post)
Yup, I've been having the exact same issue. A workaround that was working until Visu 4.8.0.0 was using TextList as the type in the frame configuration and then wrapping the text in quotes when configuring it. Im not sure if it will work with variables and I know it does not work if the type is text.
Last updated: 2025-06-17
Post by jeindhoven on Deploying to raspberry pi 5 hangs
CODESYS Forge
talk
(Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23
Post by davidbo on How do I stop/start logging in my code using AC_Datalog with composer
CODESYS Forge
talk
(Post)
I have on my Pi successfully deployed an application to which with composer AC_Datalog is added. It starts logging automatically. I want a Visualization with a start/stop button controlling the logging. That must be easy. How do I do that?
Last updated: 2025-07-07
Post by installwhat on Opc remote alarms on Linux box
CODESYS Forge
talk
(Post)
It seems that the hmi sl license only works with windows. If i'm happy using web visu, rather than target visu, is possible to use remote opc-ua remote alarms without the hmi sl? Maybe it can be included in a different license that works on Linux? thanks
Last updated: 2025-07-16
Post by timvh on Reading multiple lines from csv file
CODESYS Forge
talk
(Post)
Not sure, but maybe before you enter step 5, set i, lineindex and charIndex to 0. And the buffer variable should have a size bigger than 1 line. Additionally I think you should set bufferstart to 0 before you enter step 5. And in the OSCAT function you always point to the buffer address, but shouldn't this be (buffer + bufferstart)?
Last updated: 2025-07-23
Post by jampid on SFC comments in program
CODESYS Forge
talk
(Post)
Bonjour, Dans les propriétés des étapes et des transitions, tu peux définir les commantaires.Ensuite, il faut activer les commentaires dans OUTILS/OPTIONS/SFC et cocher les cases Commentaires pour les étapes et les transiti deons. Il en est de même pour les MACRO, les SAUTS et les ACTIONS CEI
Last updated: 2025-07-24
Post by davemansell on control loop library IIR filter
CODESYS Forge
talk
(Post)
Hi there i am experimenting with the IIR filter from the control loop library but have been unable to get it to function no matter what inputs I set I get errorID of wrong_configuration (3). Does someone have a working example that they can share. Best regards Dave
Last updated: 2025-07-29
Post by williamjmak1 on Current Visu name without Current Visu Variable
CODESYS Forge
talk
(Post)
Hello everyone, I was just wondering if anybody knows if there's a way to pull the string name of the current visualization without using the current visu variable. I'm working on a project where we don't want web clients to change the current visualization on the HMI of the machine. Thanks!!
Last updated: 2025-08-07
Post by dkugler on Mail_Service_SL Lib
CODESYS Forge
talk
(Post)
ich meine mich zu erinnern, dass ich schon FB's hatte, die Fehlermeldungen mit löschen des Enable/Execute Bits abgelöscht haben. Dann würde bei dir sobald das Error Bit gesetzt wird, nichts mehr drin stehen. Vielleicht wäre es ein Versuch wert, den String vor dem zurücksetzen des Execute in eine Variable zu speichern, ob dann was drin steht und danach erst ablöschen?
Last updated: 2025-08-20
Post by nilanjan on I want to show the current recipe name in the visualization screen
CODESYS Forge
talk
(Post)
I am having some trouble showing the current recipe name in visualization i am not using the RecipeManCommands i am using the inbuild visualization feature of Saving and Loading recipes. I need it so the user would have a track on which recipe is being used currently.
Last updated: 2025-08-24
Post by stevens on No option to create "Parameter List" in library
CODESYS Forge
talk
(Post)
I am struggling with this issue right now (again). I have nested structures with configurable array sizes. In the past I ever used parameter list. Very easy way! As of now I cannot find any solution. Ridiculous that they deprecated it without an alternative solution.
Last updated: 2025-08-26
Post by sandro66 on Application-based license Modbus Channels
CODESYS Forge
talk
(Post)
Hi, I imported an old project created with version 3.51.20.50 into the new version 3.51.21.20. I'm using ModbusFB.ClientTCP v4.5.0.0. Strangely, I can no longer download the project due to a licensing issue I didn't have before. The number of Modbus channels has gone from 1 to 54!, and there's no license that would work. Can anyone tell me where I'm going wrong? Thanks Sandro
Last updated: 2025-08-27
Post by jcarter on Webvisu Combined Authentication
CODESYS Forge
talk
(Post)
Is there a way to have both a Public No Login Screens with Screens that do require login and File Transfer? My Idea is to have the default page be View Only with a Login Button in the Corner and then Once Logged In you can change settings and download files depending on your user group.
Last updated: 2025-08-28
Post by beavel on Opening and saving files with fileOpenSave dialog
CODESYS Forge
talk
(Post)
1 + Replying in hopes of getting an answer here. I would also like to modify the look of the FileOpenSave Dialog. I have successfully adjusted the looks of the User management Dialogs but can not find a library file to adjust this particular one. Any help would be helpful. @thk @eschwellinger @sheberle .
Last updated: 2025-09-08
Post by kio123 on SysFileOpen not working
CODESYS Forge
talk
(Post)
I have exactly the same problem and tried entering “ForceIecFilePath=0” in the file “CODESYSControl.cfg” ([SysFile]). Unfortunately, this was unsuccessful. Can anyone help in the meantime, e.g., with some sample code or with the FAQ that TimvH refers to above (link no longer works)? Many thanks and best regards
Last updated: 2025-09-15
Post by blitz on Latch alarm variables from the PLC runtime
CODESYS Forge
talk
(Post)
Hi, I have a question. Does anyone know a way to change latch alarm variables from the PLC runtime? In the help there is a method described: https://content.helpme-codesys.com/en/libs/AlarmManager/Current/Interfaces/pou-IAlarm3/SetLatchVarValue.html but I don’t know how to use it correctly.
Last updated: 2025-09-23
Post by jy77812 on Visualization XY Charter Question
CODESYS Forge
talk
(Post)
Hello. I'm using Visualization XY Chart, and when I mark a circle through XY position data, a blue line is displayed in the circle with a red circle. At this time, can't I set the blue line not to be seen in the circle? Currently, whenever XY position is drawn, the line follows.
Last updated: 2025-10-02
Post by dogulas on numeric text box control
CODESYS Forge
talk
(Post)
Ok, this is how I made a numeric text field: use a Text Field properties -> Texts -> Text := %f (or %d or whatever you need) properties -> Text variables -> Text variable := (your numeric variable) properties -> Input configuration -> OnMouseDown -> Configure: Write Variable Input type := VisuDialogs.Numpad Use another variable (your numeric variable) Min val Max val etc. Please tell me there is an easier way to do this.
Last updated: 2025-10-02
Post by rene2 on How can you get the active frame index from a frame
CODESYS Forge
talk
(Post)
I think I struggle with the same issue. I tried the currentVisu variable but this is the active Visualisation. I have a dialog with a frame with frame configuration like in the picture. I would like to use the index te be used to make a button look like it's pressed/selected.
Last updated: 2025-10-14
Post by open on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Hi @ph0010421 and @Ton, Is it possible to program a stopwatch to measure a system running time when it is turn on, and pause when the system is turn off. I tried your examples when stopped, the elapsed time will then be calculated, but i need the time to be continuously counting. Warmest regards,
Last updated: 2023-12-11
Post by snhatton on OPC UA: How to change NodeId ?!
CODESYS Forge
talk
(Post)
You can change the node id by adding the following to /etc/CODESYSControl.cfg: [CmpOPCUAProviderIecVarAccess] CustomNodeName=MyPLC123 Then restart the runtime and the new Node name will appear with the connection. I don't know if it's possible to remove the |var| from the name. I hope this helps!
Last updated: 2023-12-11
Post by nz-dave on Bool turning on in case stament in wrong state?
CODESYS Forge
talk
(Post)
pretty sure its not. ive done a cross reference and only have one write that sets it to true. Only way i can stop it is to remove the function block call from the main pou that is running said case. its got me stumped:/
Last updated: 2023-12-16
Post by ph0010421 on TCP/IP client
CODESYS Forge
talk
(Post)
Hello TCIS_Send needs to be longer than 4 bytes because idata is 28 bytes long. There may be other ways, but I would make a UNION with string/array of bytes. Write your STRING into the AsString part then copy the AsBytes part into TCIS_Send (Elements [3] to [30]) then 252 would be in [31] (I've assumed the idata is always the same length)
Last updated: 2023-12-19
Post by user0815 on Web Socket Client SL -Bibliothek Fehler
CODESYS Forge
talk
(Post)
Es sind keine exceptions im Log. Ein warning (no runtime license - running in demo mode(~2 hours) und der eine Fehler. Also bevor ich probiere was zusenden. Nach dem senden kommen zwei Ausnahmen dazu. Das Bild mit den Ausnahmen packe ich mal oben zu den anderen
Last updated: 2023-12-19
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.