Post by askjong on Update variables when OPC UA Client updates. Error ID: 268468277 BadAttributeIdInvalid CODESYS Forge talk (Post)
Hi, I'm connecting to a OPC UA Server using the Data Soruce Manager OPC UA Client. This works well until the OPC UA Server updates and the OPC UA list doesn't match up when i did last clicked the "Update variables" to add variables. All the variables are still the exists and none are removed from the server, but more are added during the engineering process. The error message i get in CODESYS is "Error in OPC UA call BadAttributeIdInvalid, Error ID: 268468277". The issues is fixed when i press the "Update variables" button and just press ok without adding or removing any variables in the list. Is there a way to either automatically update the browsepath if it fails or on startup, or to trigger it by code?
Last updated: 2024-01-08

Post by imdatatas on Auto Declare window disappears by itself in the Ladder editor CODESYS Forge talk (Post)
Hello Everyone, The "Auto Declare" window disappears by itself in the Ladder editor. For example, a new function block is wanted to be added to the Ladder editor. (For example; MC_Jog block and instance name will be fbMcJog). To do this, "Empty box with EN/ENO" is added to the ladder line from the Toolbox on the right and when you type MC_Jog in the empty box and press enter, normally the "Auto Declare" window appears and you are expected to be asked to write the instance name here. However, this "Auto Declare" window closes itself immediately, it does not wait for the user to enter a value or close the window. I often encounter this situation in many IDE versions. Does this seem like a bug? If anyone has encountered a similar problem while creating a new program name, function or function block instance name regarding the "Auto Declare" window and knows a solution, I would be glad if you could share it. Best wishes Imdat
Last updated: 2025-03-06

Post by lucaver89 on Raspberry pi 3 and runtime 4.9.0.0 CODESYS Forge talk (Post)
Good morning, I'm using a raspberry pi3 as plc with the runtime 4.9.0.0. My program has many of retrain variables but when an update is performed the retrain variables comes back to default values. Is the a way to backups the retrain variables n a csv file? Is still the way to restore them from the csv? Thank you for helping Luca
Last updated: 2023-09-23

Post by talhaali on Persistent variables not working for Control Win CODESYS Forge talk (Post)
Hi everyone, I am facing issues with persistent retain variables. It was working fine. I added a few new Persistent variables and it stopped working. If I do cold reset it holds persistent variable values. But when I close control win gracefully, and opens it again then it does not. Even, it is not saving ret file in application.
Last updated: 2024-09-10

Post by pietrobalint on Persistent variables are not read after initialization CODESYS Forge talk (Post)
Hi, I realized that if I replug the power supply the persistent variables lost their value with the new software too. Cold reset do not affect the variables value but hardware reboot still reset the values. Application Composer can't be activated. What is the solution?
Last updated: 2024-10-11

Post by gatto on variables between two applications CODESYS Forge talk (Post)
Hello, I'm experimenting with two applications. I was able to start stop applications with the CmpApp library. Currently in my test the variables declared in the first application are not visible and writable in the second. I ask if there is the possibility of having variables that are visible both in the first application and in the second.
Last updated: 2024-06-22

Post by timvh on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS) CODESYS Forge talk (Post)
It is a known issue. It only happens with CODESYS and Wago controllers and the Persistent Variables. It seems related to using 64 bit variables in the PV list (e.g. LREAL). Internally in the PLC everything works okay. It is just a monitoring issue.
Last updated: 2025-10-26

Post by eschwellinger on Persistent variables are not read after initialization CODESYS Forge talk (Post)
which version of the runtime do you use?
Last updated: 2024-09-02

Post by hambergg on Retain Variables on fRAM CODESYS Forge talk (Post)
Hi regarding NVRAM with SPI or I2C I expected reference too!
Last updated: 2024-09-03

Post by danieldiaz on Problem with FB execution CODESYS Forge talk (Post)
Problem Solved, I was overwriting the variables somewhere else
Last updated: 2024-04-05

Post by pascaljt on Function block for Ethernet/IP CODESYS Forge talk (Post)
Hello, I program a function for an Ethernet/IP controller. I made a structure with input and output corresponding with the map of my controller for the function block. My problem is that I don't know how to do the link between the controller and my PLC (CC 100 from Wago). The addresses declare in Codesys are illogic, The first addresses are 12 and 13 then 7 then 4. How to do corresponding the addresses of the controller and the input / output structure ? IP adress ? Does I must create the all variables of controller with the controller adresses to use with the function block ? Thanks for your help. (I hope I'm clear, I'm not english)
Last updated: 2023-10-26

Post by nathant on Saving variable values on power cycle (RevPi Connect) CODESYS Forge talk (Post)
Hello, this seems to be a known issue, but persistent/retain variables don't seem to work properly on RevPi devices. Is there a workaround to this? All I need is for a few configuration variables to be remembered through power cycle.
Last updated: 2023-12-03

Post by fless on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
to get the address just use ADR( ) variables defined in a VAR_IN_OUT block are references pointing to the passed variables. VAR_IN_OUT MyVar: bool; END_VAR VAR adrMyVar: __XWORD; END_VAR adrMyVar := ADR(MyVar);
Last updated: 2025-01-26

[Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8 CODESYS Forge talk (Thread)
[Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8
Last updated: 2025-03-26

Post by jschu on Switch visualization style at runtime CODESYS Forge talk (Post)
Hello , will this be changed in an upcooming version? The current method is to use all the color Variables for buttons and object as changeable variables but the amount of work for this results in a bad cost-benefi ratio.
Last updated: 2025-05-15

Can a table be used as an input to date and time variables on a function block diagram? CODESYS Forge talk (Thread)
Can a table be used as an input to date and time variables on a function block diagram?
Last updated: 2022-09-15

Can a table be used as an input to date and time variables on a function block diagram? CODESYS Forge talk (Thread)
Can a table be used as an input to date and time variables on a function block diagram?
Last updated: 2022-09-15

Post by damian177 on Persistence variables PFC200 CODESYS Forge talk (Post)
Hi, I using persistence variables like below: VAR_GLOBAL PERSISTENT RETAIN id_worker1: ARRAY [0..3] OF INT := [231,234,176,222]; id_worker2: ARRAY [0..3] OF INT := [211,129,125,221]; Initial values can cause some problems?
Last updated: 2023-12-08

Post by alex-wall on Network Variables not updating CODESYS Forge talk (Post)
This worked for me. I had four identical PLC's. Three of them worked just fine with 255.255.255.255 as the broadcasting address but the 4th would not update the variables. Changed it to 192.168.x.255 and everything worked.
Last updated: 2024-05-07

Post by jasperclauwaert on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS) CODESYS Forge talk (Post)
Hi everyone, I’m working on a WAGO PFC100 with CODESYS. During development everything worked fine, but in the final stage I set several variables to PERSISTENT RETAIN. When I go online, most of these persistent variables cannot be monitored. Instead, I see: <Value of the expression cannot be retrieved> Interestingly, a few variables do show their values correctly, but the majority do not. The variables are not used as pointers or in any unusual way. The application compiles and runs without errors. Has anyone experienced this before? Is this a known issue with PFC100 or CODESYS? Any ideas on what could cause this behavior? Thanks in advance! Jasper
Last updated: 2025-10-23

Post by jasperclauwaert on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS) CODESYS Forge talk (Post)
Hi everyone, I’m working on a WAGO PFC100 with CODESYS. During development everything worked fine, but in the final stage I set several variables to PERSISTENT RETAIN. When I go online, most of these persistent variables cannot be monitored. Instead, I see: <Value of the expression cannot be retrieved> Interestingly, a few variables do show their values correctly, but the majority do not. The variables are not used as pointers or in any unusual way. The application compiles and runs without errors. Has anyone experienced this before? Is this a known issue with PFC100 or CODESYS? Any ideas on what could cause this behavior? Thanks in advance! Jasper
Last updated: 2025-10-23

Post by abrarsk on SysCom Library Usage CODESYS Forge talk (Post)
Update: I was able to successfully use the SysCom.lib. I had to install SysTypes2Interface library as well and wrote following code. Declaration hCom : RTS_IEC_HANDLE; pResult : POINTER TO RTS_IEC_RESULT; Implementation hCom := SysComOpen(ComSettings.sPort, ADR(pResult));
Last updated: 2024-08-10

Post by andrax on Variable Length Array - Cannot mix variable and fixed length dimensions? CODESYS Forge talk (Post)
Arrays with variable lengths are a bad idea. This makes your system unstable and can lead to crashes. Declare your array large enough to reserve enough memory
Last updated: 2025-05-24

Post by reinier-geers on Pointer Axis CODESYS Forge talk (Post)
I want to make a FB of MC. But i need a variable for Axis. How do i have to declare that ? ptAxe : AXIS_Ref_SM3; //:= SM_Drive_ETC_Delta_ASDA_A2 ; this is somehowe a problem
Last updated: 2024-01-12

Post by reinier-geers on Axis declare CODESYS Forge talk (Post)
In motioncontrol every block start with Axis. How can i make a variable to make my own FB ? Somthink like : _Axe : pointer to Axis_Ref_MC := Axis_1 ;
Last updated: 2024-02-13