Post by installwhat on C0077 on one machine but not another
CODESYS Forge
talk
(Post)
It doesn't load differently codesys seems to be behaving differently. Original version of ethercat master in project archive is 3.5.15.50, compiler is 16.4 as is codesys I'm using. It builds fine in vm and not on local machine. The reason is not obvious. It builds on local machine with ethercat master at 3.5.16.0. I'd really appreciate advice
Last updated: 2024-06-11
Post by nano on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
this is not easily. From Point of SL-Licenses Codesys didnt provide the informations how to do. We created an own CDS-Component for that Behaviour. This Informations are available for OEM, if you are an OEM you can find the Informations in the RTS-Documentation.
Last updated: 2024-06-14
Post by vitorp on Visualization Toolbox in German
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys. I installed it on my computer and set the language to English. Most of the localized text appears in the correct language, but the Visualization Toolbox and the element properties are in German. I haven't found a way to change them to English. Can someone help me with this?
Last updated: 2024-06-17
Post by matt-purcell on Which Lib to use, connect to a socket with URL instead of IP address
CODESYS Forge
talk
(Post)
I've been searching through these libraries, syssocket and net base services and they all seem to use the same structure for IP address for the connect function, SOCKADDRESS. At a glance, it doesn't look like that'll work, maybe it's just missing in the documentation somewhere?? I'm wondering if anyone has done it.
Last updated: 2024-06-17
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by gatto on variables between two applications
CODESYS Forge
talk
(Post)
Hello, I'm experimenting with two applications. I was able to start stop applications with the CmpApp library. Currently in my test the variables declared in the first application are not visible and writable in the second. I ask if there is the possibility of having variables that are visible both in the first application and in the second.
Last updated: 2024-06-22
Post by nano on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
which ports in detail are configured. the search of the rts works via broadcast-messages, programming with tcp-port on p2p-connection woth port-hopping, handled by runtime after siccesfully handshake. look at this entry on forge https://forge.codesys.com/forge/talk/Runtime/thread/4078a2ed28/
Last updated: 2024-06-23
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
I have now conducted some tests. The problem occurs when the Python script establishes an OPCUA connection, even if I only establish the connection without reading or writing any data. Is there another way to exchange data between Python and CODESYS without having to put in a lot of effort?
Last updated: 2024-06-24
Post by koppit on SysComRead Timeout Parameter
CODESYS Forge
talk
(Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26
Post by mait-tim on Errors after moving from SP18 to SP20/21
CODESYS Forge
talk
(Post)
Hello, Im running into a problem after moving from SP18 to SP20 or SP21. After the update I have an error with the TextFieldInmputHandler.VariableWritten which is implemented if de visualisation part of my software. The interface seems to have changed. I cannot find the new implementation. Does anyone know how to solve this issue.
Last updated: 2025-10-20
Post by mait-tim on Errors after moving from SP18 to SP20/21
CODESYS Forge
talk
(Post)
Hello, Im running into a problem after moving from SP18 to SP20 or SP21. After the update I have an error with the TextFieldInmputHandler.VariableWritten which is implemented if de visualisation part of my software. The interface seems to have changed. I cannot find the new implementation. Does anyone know how to solve this issue.
Last updated: 2025-10-20
Post by kaotic2499 on Upgraded Raspberry 2b to Raspberry 5, Trends Broken?
CODESYS Forge
talk
(Post)
Is there anyone who can assist me? ill just have to raise this as a bug with codesys otherwise. I see this as the only way foward. ill attempt a fresh install of RPI in the next day or two, but thats all i had previously so π€·ββ
Last updated: 2025-10-21
Post by snguyen on Any ways to prevent Infinite scroll when moving an object to the left or top edge?
CODESYS Forge
talk
(Post)
I've been making few HMIs and I'm starting to get annoyed that whenever I try to align an object to the left or top side of the frame, it quickly scrolls into that direction infinitely. Is there a way to prevent that?
Last updated: 2025-10-24
Post by alessandro on Configuring a CIP object for Explicit Message
CODESYS Forge
talk
(Post)
We used this with shared memory codesys. and work. OpENer is an EtherNet/IPβ’ stack for I/O adapter devices; supports multiple I/O and explicit connections. And we adapt this also for Implicit message. But for arrive to the end we spend a lot of time. :-(((
Last updated: 2025-10-24
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
Hello everyone, following corrupted data on the SD card of our Pi3B+ provided with a machine, we reinstalled a CODESYS image for Raspberry Pi, but we cannot find the 4.9.0.0 runtime that is compatible with the project. Currently, the machine is on 4.1.0.0, and we tried a more recent version 4.13.0.0, but there are error messages. Thanks in advance.
Last updated: 2025-10-24
Post by kporter on SoftMotion, accessing PDO input data via object ref/pointer
CODESYS Forge
talk
(Post)
Now that SP21 is out, what's the answer? I want to get a pointer to the TxPDO and RxPDO structs. I can generate a STRUCT declaration from the ESI file with a bit of Python. I just need to get the pointer from the ETC_Slave.
Last updated: 2025-10-29
Post by fahrettin on CODESYS 3.5.17.30 Setup Error
CODESYS Forge
talk
(Post)
While trying to install CODESYS 3.5.17.30 (64-bit) on my Windows 11 computer, I'm getting the errors below. The first error occurs near the end of the installation. Once you bypass it, the installation returns the second error. Do you have any suggestions for a solution? By the way, I've tried this on several PCs, but I haven't found a solution.
Last updated: 2025-10-30
Post by gseidel on SMC_ERROR SMC_CGR_INVALID_POSPERIOD
CODESYS Forge
talk
(Post)
Hi blitz, that usually means that the modulo period, when converted to increments, is larger than 2^31. (The bus bandwidth is usually 2^32.) What is your "technical unit", do you program in angular degrees? And what is the modulo period? If you want you can post the drive configuration (screen shot of the "General" and "Scaling/Mapping" page). Best regards, Georg
Last updated: 2025-12-16
Post by aniket-b on Scara3 kinematic robot error
CODESYS Forge
talk
(Post)
Thanks Georg for responding. I have followed the suggestion mentioned in the real time problem. However, it does not solve the problem. The weird part is, the robot stops at the same position randomly and it does not stop when I increase the speed of the motion.
Last updated: 2025-12-23
Post by yohayr on Access Violation sherd memory
CODESYS Forge
talk
(Post)
Hi, once in a while I get an Access Violation exception in Sherd memory pointer. the strange thing is that I protect the pointer dereference and I get this exception 1 line after the protection. I added photos of the exception can someone tell me what is that about?
Last updated: 2025-11-25
Post by yohayr on Access Violation sherd memory
CODESYS Forge
talk
(Post)
Hi, once in a while I get an Access Violation exception in Sherd memory pointer. the strange thing is that I protect the pointer dereference and I get this exception 1 line after the protection. I added photos of the exception can someone tell me what is that about?
Last updated: 2025-11-25
Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Post)
Turns out I managed to get a connection to my PLC. It seems that a few weeks ago Wago released something with version 4.3.3(25). So I reset my PLC to Factory-Reset, set it to the 192.168.1.17 IP and changed the IP to the one I wanted with the Wago EthernetSettings tool. Then updated the latest firmware using the WAGOupload tool. Now the PLC came back up without a PLC runtime running, so in the Web-tool I wen't to the "Configuration"/"PLC Runtime" and selected the runtime version "CODESYS V3". I uninstalled all Codesys versions and installed the version from the download package of Wago together with all the packages the bundle provided. After creating a new project I didn't select the old PFC200 runtime, but one of the dozens of new device profiles, that it now listed. With these settings I was then able to connect to my PLC. Now I hope I'll get the existing project that I had ported to this new structure. Sorry for the noise. Chris