Post by lzml on HTML5 visualization controls disabled on CODESYS Control for Linux SL - overlay not supported? CODESYS Forge talk (Post)
Hello, I'm developing a custom HTML5 visualization control (via the HTML5 Control Editor / Tools > Visualization Element Repository) and I'm running into what looks like a target-device limitation when trying to deploy it to CODESYS Control for Linux SL. I'd like to understand whether this is a known/expected limitation or something in my setup. Environment - CODESYS Development System: V3.5.22.0 - Target runtime: CODESYS Control for Linux SL, package version 4.15.0.0 (installed together with CODESYS Edge Gateway for Linux 4.15.0.0) - Visu system libraries (VisuElems, VisuElemsAlarm, VisuInputs, VisuNativeControl, etc.): version 4.7.0.0 - Host OS: Debian RT (minimal/base installation) - We only use WebVisu, not TargetVisu. What I did 1. Built a custom HTML5 control following the official HTML5-API-Examples pattern (.html5control.xml manifest + ElementWrapper.js + CSS), installed it successfully via the HTML5 Control Editor ("Save and Install") into the Visualization Element Repository. 2. In the Visualization Manager, enabled "Support client animations and overlay of native elements" (documented as required for HTML5 controls to work at all). 3. With the project's Device set to CODESYS Control for Linux SL, compiling/downloading fails with: "Overlay is not supported for your target visualization device." (Visualization Manager) Build stops with 1 error, download not possible. Isolating the cause - The Visualization Element Repository confirms the control is correctly installed. - With the project Device set to a Windows-based device, the HTML5 control appears and is enabled in the Toolbox as expected. - With the project Device set to CODESYS Control for Linux SL, the HTML5 control is disabled/missing from the Toolbox entirely, even though it's installed in the repository. This points to the Linux SL device description simply not declaring overlay/HTML5 support, rather than a missing package or Debian-side dependency (WebVisu itself already works fine for standard/native visualization elements on this same target). Questions 1. Does CODESYS Control for Linux SL currently support WebVisu overlay (and therefore custom HTML5 controls)? I found documentation stating overlay support for target visualizations (Windows and Linux) was added starting with CODESYS Development System V3.5.17.0, but that seems to refer to TargetVisu, and our case is WebVisu-only on a Linux runtime. 2. If not currently supported, is this on a roadmap, or is there a different Linux runtime package/edition that does support WebVisu overlay for HTML5 controls? 3. Is there any Linux-side configuration or package needed to enable this (given the check appears to happen against a static device capability declaration rather than a live server check), or is this purely a matter of the device description bundled with the current Control for Linux SL package? Thanks in advance for any pointers.
Last updated: 2026-08-05

Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3 CODESYS Forge talk (Post)
Some findings on this issue: PEAK CAN Driver is the same as in every PCI card from PEAK. I updated the inf file. Here are my steps: 1. Include right VendorID into the *.inf file 2. Disable Windows driver check (Disable WHQL check). This you need because 3S driver is not certified. You will find steps via google or ask chatgpt :) 3. Select: Select driver from a list and navigate to the folder. Say yes to install an uncertified driver. 4. Driver installed and device without errors I did the same with CAN Card from ESD, but here you dont need to include the vendor ID. In ANY CASE it was not successful. The RTIOwdmgeneric is not available in Codesys or anyhow accassable :( I wonder that it fails in two cases, two suppliers, two driver in the same way. How can RTIOwdmgeneric implemented into the project?
Last updated: 2024-12-20

Post by josul on Web Client HTTPS Communication Issue CODESYS Forge talk (Post)
Web Client Library Documentation Company: 3S - Smart Software Solutions GmbH Title: Web Client Version: 1.0.1.7 Categories: Application|Utils Namespace: WEB_CLIENT Author: 3S - Smart Software Solutions GmbH Placeholder: WebClient I encountered an issue using this library above. Note it is now part of Codesys IIoT Libraries SL in the form of Web Client SL, but I am not using this version. I was sending Content-Type: application/json, HTTP POST using a HTTPS URL. No issue observed initially, successful operation. At some point operation stopped and the codesyscontrol.log file started to accumulate errors: ERROR: TlsCreateContext2: Failed to save context. An application reset failed to resume operation and I was unable observe any TCP connection forming to a destination port 443. The error appeared as a TCP_INIT error. I can find no details as to what may have happened or why a reset of the PLC application did not resume operation. Testing with a curl operation proved to be successful, so I am confident there was no fundamental networking issue preventing a TCP connection forming. The solution was to reboot the hardware itself, but this is not satisfactory in the long term. Is there any description of the TLS error I received? Is there any suggestion here that there might be an issue with certificates? Any advice or information is appreciated.
Last updated: 2025-06-05

Post by gseidel on AXIS_REF_SM3 Error Codes? CODESYS Forge talk (Post)
Hi SLUCodesys, dwErrorId is a drive specific error number. The drive documentation should be consulted to interpret it. (Note that you should use MC_ReadAxisError to read this error, see https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/MC_ReadAxisError.html. Accessing the internal variable will result in outdated values if the acis error is not mapped by PDO and is not recommended in general.) uiDriveInterfaceError holds errors of the SoftMotion driver for the drive. It is also an internal variable, not intended for direct access. It is intended for logging, the PLC log will contain the drive interface error, consisting of this number and an error text. My recommendation for handling axis errors in the CODESYS application: 1) Use MC_ReadStatus on the axis to find out whether it is in state Errorstop 2) If in Errorstop, there are two possibilities: an error reported by the drive (MC_ReadAxisError) or an error of the SoftMotion function blocks (output MC_ReadStatus.FBErrorOccured). 3) If there is no drive error, you can use SMC_ReadFBError https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/FBError/SMC_ReadFBError.html Best regards, Georg
Last updated: 2025-09-24

Post by nicetuxedo on Can not activate license on Raspberry pi CODESYS Forge talk (Post)
Hello everyone, I'm hoping for some assistance with a license activation issue: a software crash has left my license in a strange state. Here is the sequence of events: I purchased a new license for the Raspberry PI from the official CODESYS web store. I opened the CODESYS and started the online activation process using the ticket number I received. During the activation, the CODESYS software threw an exception and crashed. I was not able to see if the activation completed. After restarting CODESYS, I attempted to run the activation process again with the same ticket number. The License Manager now gives me an error stating that the ticket has already been activated/used. I am now stuck because my installation is not licensed, but the activation server believes my ticket has been consumed. Has anyone encountered this before? Is there a way to have the ticket status reset?
Last updated: 2025-10-08

Post by yannickasselin on Connect to remote PLC via local pc and teamviewer CODESYS Forge talk (Post)
Yes it is possible. I did it a lot of times using TeamViewer VPN. Unfortunately, TeamViewer VPN only works on Windows. If the remote PLC is a Codesys runtime running on Windows, you should be able to login directly using TeamViewer VPN if it is installed on the PC/PLC. If it is not Windows based, you can still do it but you need to have a Windows based PC acting as a gateway in the middle. In this case you need to enable IP Forwarding on the Windows remote PC (the gateway) and you need to setup the gateway IP address on the PLC to be the address of the Windows PC. Then you need to add a route on your local PC to point to the gateway PC for Codesys communication. I know it may not be detailed enough but I did not want to make a whole tutorial on how to do it. Bottom line, it is possible. I do it all the time.
Last updated: 2024-02-02

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
The hole setup is made by 3s. So its a comination of one not two. If Epis decide not to support extra licence whats then the funtion of providing an option with a single license ?? So the idee by 3s has a flod. Epis change the system to add the Stick. I send controller inc stick to Epis. On my software i can see the stick. An then you tel me i need a other license to use an license ?? Makes completly no sense. Codesys should be flexible but is not. I tried Delta. But has no HMI and has its own Codesys ?? Why ?? Then i tried Crist. The block there own system by a password. But dont know the password and cant switch it off. At the end the want me to pay for support to solve ther own made problem. So i send it al back. The extra license is adviced by 3s . Now a few month later still no working solution.
Last updated: 2024-05-01

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
Some new test. Now I cannot connect from Automation server to my gateway in any way also from my office setup with my unit directly connected to my router by dhcp. I can use the IDE and the tool "Connect Edge Gateway" and successfully connect to my server/link to my Automation server account. However no PLC will respond from Automation server "Network scan". I guess the traffic should be initiated by the gateway towards automation server? Any tips on how I can diagnose my problem? Ports to be opened etc? Thing is that this has been working previously but not now (base system has been updated from debian 12 to debian 13, but I dont know at which point it has stopped working). Setup as before. A "Codesys Control for Linux SL" running on a debian 13 installation. Any help/tips appreciated! Per Update. Found the error. Had a wrong gateway-setting. Which meant the PLC could not reach internet. Checked by "ping google.com" from the PLC.
Last updated: 2026-02-12

Post by lzml on HTML5 visualization controls disabled on CODESYS Control for Linux SL - overlay not supported? CODESYS Forge talk (Post)
Thanks for the suggestion - I updated everything via the CODESYS Installer and restarted, but I'm still hitting the same error. What I did - Updated via Tools > CODESYS Installer - Visualization system libraries (VisuElems, VisuElemsAlarm, VisuInputs, VisuNativeControl, etc.): 4.7.0.0 -> 4.10.0.0 - CODESYS Control for Linux SL: 4.15.0.0 -> 4.21.0.0 (based on CODESYS SDK 3.5.22.20) - Restarted CODESYS Development System Checked project environment (Project > Project Environment) after restart - Compiler version: 3.5.22.0 - Library versions: all up to date - Visualization Profile: CODESYS Visualization 4.10.0.0 - SoftMotion version: 4.20.2.0 Result: compiling with Device = CODESYS Control for Linux SL still fails with the same error: "Overlay is not supported for your target visualization device." The custom HTML5 control is still disabled/missing from the Toolbox with this Device selected (same as before), and still appears normally when I switch the Device to a Windows target. Is there anything else specific I should check (e.g. a setting on the Device description itself, a different SL package/edition, or is WebVisu overlay for custom HTML5 controls simply not implemented yet for CODESYS Control for Linux SL regardless of package version)? Any pointer appreciated.
Last updated: 2026-08-05

Post by davidbo on How to switch between dynamic IP address and dynamic? CODESYS Forge talk (Post)
Well. One can do that, I have found a python script which can modify /etc/dhcpcd.conf and I suppose there is a way I can execute it from CODESYS and it seems to be the only way
Last updated: 2023-11-08

Post by ellocco on Leitungsverzweigung mit einem existierenden Block (z.B. AND-Glied) zu verbinden CODESYS Forge talk (Post)
Thanks for your response and your idea. To sum up, you also have no idea how to connect two existing blocks. Meanwhile I worked with "PLCnext engineer" and the result is:
Last updated: 2024-11-11

Post by ojz0r on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
One thing you could do is create an object with the variable as field with a function and procedure to get the variable (read) and set the variable (write). These are then called from your program and the vizualization.
Last updated: 2025-02-20

Post by eschwellinger on function block output CODESYS Forge talk (Post)
I think you should use a piece of hardware in between your drive (pulse/direction) and the plc like for example Beckhoff EL2521 - so Ethercat might be to choice if you need CNC and SoftMotion. EK1100 and EL2521
Last updated: 2024-01-05

Post by nksr on Is using 'en-gb' and 'en-GB' in visuelems.currentlangauge the same? CODESYS Forge talk (Post)
I am currently programming a language switch program. So, the text flickers between 'en-gb' and 'en-GB' in visuelems.currentlangauge and even if I put a breakpoint, it still flickers. Can you please suggest a solution? Thanks
Last updated: 2024-01-31

Post by jetme on Rampup and rampdown CODESYS Forge talk (Post)
i'm using FB Ramp_INT function to ramp my pump up and down but I will like to ramp up at a different time and also ramp down at a different time. How can I do that.
Last updated: 2024-03-28

Post by jeroenaero on Difference between using OPCUA symbol configuration and OPCUA Server object CODESYS Forge talk (Post)
Hi, What is exactly the difference between using symbol configuration as OPCUA server or using the Codesys object OPCUA server? What are the advantages and disadvantages of using symbol configuration and OPCUA server object. Please let me know
Last updated: 2025-10-30

Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
I have installed: SM_Drive_PosControl 4.18.0.0 and SM_Drive_RaspiStepper_Direct 0.0.0.7 and SM_Drive_RaspiStepper_PulsDir 0.0.0.7 And when I "Generate Code" I immediately get 6 errors (see attached file) What can I do?????
Last updated: 2025-11-09

Post by t-probst on Strong Private Key Protection for Encryption Certificates CODESYS Forge talk (Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22

Post by mubeta on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18

Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14

Post by tk096 on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup CODESYS Forge talk (Post)
Hi, under this circumstances the performance of a Raspberry Pi 4 should be sufficient to run a Softmotion robotics application. A closer look at the project would be required. Maybe you could contact the codesys support? Usually it is recommended to run the planning task cyclically every 2ms with task priority of 0 on a dedicated core. In the task configuration you can have a look at the average and maximum execution time of the planning task. You could use the function block SMC_TuneCPKernel (https://content.helpme-codesys.com/en/libs/SM3_Robotics/Current/SM3_Robotics/POUs/AdministrativeConfiguration/Computation/SMC_TuneCPKernel.html) to define suitable values for the parameters 'fSyncBufferDuration' and 'fPlanningInterval'. However, as previously mentioned, the performance of a Raspberry Pi 4 with realtime patch should be sufficient. The 'fPlanningInterval' parameter specifies the maximum planning step width in seconds. The cycle time of the planning task should not permanently exceed this value. A higher value reduces the computational effort, but can lead to a violation or no full utilization of the set limit values for velocity, acceleration and jerk. From a starting value of 0.016 seconds, the value should be increased gradually until the performance is acceptable. The parameter 'fSyncBufferDuration' specifies the size (in seconds) of the buffer between the planning and fieldbus task. The cycle time of the planning task must not exceed this value at peak times (this will lead to the error SMC_CP_QUEUE_UNDERRUN). A higher value can compensate for peaks in the cycle time of the planning task. At the same time, however, this also increases the latency for executing interrupts and aborting movements.
Last updated: 2024-03-22

Post by ofey on Codesys Soft PLC OPC UA server CODESYS Forge talk (Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14