Post by dhumphries on Minimum system requirements for codesys control standard S
CODESYS Forge
talk
(Post)
I'm working on a low cost project and I'm considering installing the Codesys runtime on a PC running Linux Debian instead of buying a PLC with a pre-installed runtime. For my needs the Control Standard S license should be capable of running some IO over ethernet/ip, and a webvisu. The PC I am considering has a AMD GX-424CC 2.4GHz processor (4 core/4 thread) and 4GB RAM. This may compare to a raspberry pi4, but I know an X86 processor doesn't directly compare to an ARM processor, and a processor can have a high clock speed but other factors like L2/L3 cache can influence the overall performance. I can't find any published specs for the processor and RAM requirements to run the Codesys Control runtime, does anybody have a link to the minimum system requirements or experience using devices that are at or below the minimum system requirements. A raspberry pi with the control for raspberry pi SL runtime license would be the lowest cost option, but the license is not for commerical use. This restriction is somewhat vague, can anybody clarify if this means I can use a raspberry Pi runtime for in-house automation, what about if I am selling an integrated system that uses a raspberry Pi as a controller?
Last updated: 2023-12-25
Post by aseitzinger on CODESYS Control for Linux SL on virtual machine?
CODESYS Forge
talk
(Post)
Hello, there in different information available regarding the possibility to run CODESYS Control for Linux SL on a virtual machine. https://forge.codesys.com/trg/linux-sl/home/Home/ says CODESYS Control for Linux SL is a runtime system, which can run on any Debian based X86 PC, VM or Cloud container... https://store.codesys.com/media/n98_media_assets/files/2302000005/3/CODESYS%20Control%20for%20Linux%20SL_de.pdf says CODESYS Control for Linux SL can not be used on virtual hardware Currently I run the package mentioned on a virtualized debian machine running in PROXMOX Virtual Environment 7.4-17 and apart from huge jitter it runs without problems. The CODESYS key is passed as a USB defice to the VM. I wonder why there are different statements regarding the suitability in virtual machines and if the jitter would be reduced by installing CODESYS runtime on the host installing CDS runtime on the host and using a preemptive kernel (if available for the PROXMOX installation leaving CDS runtime where it is (on the virtualized debian machine) and install a preemptive kernel on the host and on the guest... Any advice is appreciated. Greets Arno
Last updated: 2024-01-08
Post by edepalos on Text list from sd card
CODESYS Forge
talk
(Post)
Hi guys, I have a textlist in my project which is working just as expected in a drop down list. I would like to move this text list to a sd card and access it from there, because I want to ease the editing of the contents of this textlist. I'm imagining a solution like the operator shuts down the plant, takes the sd card out, edits the textlist on the card with a windows machines notepad, then reinserts the card in the PLC and restarts the plant, having the new content of the textlist populating the dropdown list. I'm sorry that I'm asking you to spoonfeed me, but I did not find anything straightforward to do this... I saw in the Project>Project settings>Visualisation a relative path thingy, but I have the plant in operation and I would not like to make 100 trial and errors right now... I'm also not interested in SysLib file read commands and stuff, I would just like to access the file from the cards part, I don't want to replace its contents dynamically or such... nor I have language files or recipes... Thank You in advance! Br, Ede
Last updated: 2024-01-16
Post by alex00 on DCS / Central Engineering with Codesys support
CODESYS Forge
talk
(Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19
Post by alex00 on DCS / Central Engineering for Codesys
CODESYS Forge
talk
(Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by brell on Automatic xExecute NBS.TCP_write
CODESYS Forge
talk
(Post)
I've recently started experimenting with CODESYS for a project and am fairly new to it. I'm currently working with Function Block Diagrams (FBD) to set up TCP communication between a server and a client, where the client is implemented as a Python script. Once the communication is established, my connection status changes to True, which is the expected behavior. My challenge arises with the TCP write module, which requires the xEnable_write flag to toggle between True and False. If xEnable_write remains True, the module only performs a single write operation. To address this, I introduced a falling edge trigger (F_TRIG), expecting it to help in toggling xEnable_write and it does, However, I've encountered an issue where in the beginning after connxion established I need to manually set xEnable_write to True for the system to work as intended. I'm looking for a way to automate this process so that xEnable_write becomes True automatically upon establishing a connection . Initially, I tried setting xEnable_write to True from the start, but this approach didn't work well since it left the flag permanently True, preventing further toggling. I also experimented with using a TON timer, but I faced similar issues. I am seeking a solution that automatically toggles xEnable_write between True and False after a connection is established, ensuring continuous write operations without manual intervention. Any advice or guidance on how to achieve this would be greatly appreciated."
Last updated: 2024-03-05
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via CmpApp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Hello mates, I'm working with CODESYS V3.5 SP20 on a Raspberry Pi and I use "Raspberry Pi MC SL" as device on the project. I've installed the Control Standard L (multicore) license on a Wibu System usb-Dongle (cmStick/4.50) that already had another license from another vendor. I follow the online activation procedure from CODESYS documentation. Raspberry Pi has already CodeMeter installed for the other license. When I plugin the dongle on Raspberry and start the Runtime from Raspberry Pi Update in CODESYS I receive the message that I'm on Demo mode because the license is missing. I double checked that the license is activated in the dongle, through the WebAdmin of CodeMeter and the second license runs properly without any issue. I have already try to change the dongle from HID to MSD device and backward but the the Runtime cannot recognize the Dongle. I have also try to stop and start the Runtime through CODESYS without success. Is there anything else I can do to fix this issue?
Last updated: 2024-04-22
Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors
CODESYS Forge
talk
(Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02
Post by william-blandon on RecipeManCommands.ReloadRecipes
CODESYS Forge
talk
(Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23
Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win
CODESYS Forge
talk
(Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04
Post by kleeswi on Visualization scaling problem with B&R T30 panel
CODESYS Forge
talk
(Post)
The probelm arises for the B&R T30 panel after updating Codesys from 3.5.17 to 3.5.19 patch 5. We have to use 3.5.19 for other reasons so we cannot downgrade the version. The scaling problem only exists for the B&R 6PPT30.0702.20F025 panel, the B&R T50 panel and a esa lumia panel work. When we choose a fixed resolution it looks also good, however we also want to support the esa lumia panel with a different resolution. The images show the anisotropic and isotropic option. In the anisotropic option it scales the hight correctly but not the width and in the isotropic option is scales both hight and width false, it also does not start in the top left corner. Does someone have any suggestion why it does not work anymore with the new codesys version and are there workarounds? I added all versions with visualization packages as an image, visuElems is 4.4.0.0.
Last updated: 2024-07-29
Post by abauza on Image Pool using in other libraries
CODESYS Forge
talk
(Post)
Hi im Albert, im developing libraries for my PLCs and i have some issues on visualization part. First of all I have done a library that have a image pool with a list of 4 gifs "ImagePoolErrors" (i've tested in other projects and it works) but the problem comes when i create another library that in the visualization part contains images from my image pool library, when i simulate a program that includes a instance of my second library object the visualization images dont show, any of them, i've checked all the references and tried some options of the image properties but without any difference. Here is the screenshots of the first library (that contains Image Pool) and the second library (that includes images of the image pool first library) and the visualization simulation (with the missing image gif issue). Any idea of what i forgotten in the process? If you need any detail of the library or of the project or you need the library file, ask me, thank on advance
Last updated: 2024-08-19
Post by ellocco on XOR with four Inputs with OR-, NON- and AND-Operators
CODESYS Forge
talk
(Post)
My topic is more of academic nature, I would like to implement an XOR-operation with four inputs on my own (without the predefined XOR-operator) in a function block diagram (FBD). I have two proposals. One works fine and the other one is just an idea, but I do not know, if it is possible to code it in CODESYS V3.5 SP18 in form of a FBD. Here the one that works: And here an idea, which I have not managed to code it as an FBD: Any ideas? Is the 2nd diagram a correct interpretation of the coding task? And is there a way to implement it in form of an FBD in CODESYS V3.5 SP18? Followup (08-Nov-2024): Also in the current version of CODESYS (V3.5SP20Patch3) I have not managed to connect the existing blocks. In the alternative SPS-IDE PLCnext Engineer it is possible.
Last updated: 2024-11-08
Post by jinlee on Dynamic I/Os Mapping
CODESYS Forge
talk
(Post)
Hi guys, Recently, I am working at the Dynamic I/Os mapping feature in Ecockpit or Codesys v3.5. I have been trying the libraries. However, it looks like it will not work as I wanted. I want to build the PLC which can detect all the I/Os itself and from there, I can do something on these channels. For example, the current setup is one digital input card, one digital output card and one analogue input card. Then, I want to add one more card into the setup e.g. one more digital input. Then, wago screen can detect this and we can assign them to tasks for example to control digital output. May I know is it possible ? Kind regards
Last updated: 2023-08-18
Post by arnaud on eCockpit - unable to start simulation
CODESYS Forge
talk
(Post)
Hi there! I'm using eCockpit WAGO software to develop HMI's for multiple projects. As I recently starting this, my knowledge on the software is somewhat limited (so maybe my question is a simple one). For most of my projects I can simulate the application and start it to test the code and HMI. However for two projects, I can initiate the "simulation activation" but I cannot start it. Nothing happens when I press start and the visualization shows "The online visualization is waiting for connection. please start the application". - I don't see any errors in the messages - Initially the project are made by a colleague, which moved on. I guess I'm forgetting something, like missing a setting. I appreciate any help I can get. If you need more information to help me out, let me know. Thanks!
Last updated: 2023-08-25
Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
I have a project with several buttons and dialogs. Most of the dialogs are opened using the Open Dialog action of the Input configuration of the buttons. Some dialogs are openend using the FbOpenDialogExtended FB of the Visu Utils library and the FbOpenDialogExtended FB is called in the Execute ST-Code action. I am also using the FileOpenSave dialog from Visu Dialogs which requires an OnDialogClosed action to read out. I realized that the OnDialogClosed action which is meant for the FileOpenSave dialog also triggers if a dialog is closed, which was previously openend using the FbOpenDialogExtended FB. Is there a way to detect which dialog was closed last and specify to which dialogs the OnDialogClosed action reacts?
Last updated: 2023-09-20
Post by alimans on Hex string
CODESYS Forge
talk
(Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20
Post by ggarcia94 on CANOPEN SDO configuration
CODESYS Forge
talk
(Post)
Hello, I´m connected to two drives via CANOPEN. The connection seems to be ok. However, I´m not able to get the PDOs to work even tho they are configured as in the manual of the drives. Looking at the SDOs I´ve seen that for each PDO there is a "Disable PDO" SDO that does not exist in the manual or in the EDS file of the drives. This "Disable PDO" signal has the same Index and Subindex as another SDO used to set and enable the COB-ID of the PDO. I´m assuming this is normal but why is Codesys creating a "Disable PDO" SDO for each PDO and could that be the reason the PDOs are not working?
Last updated: 2023-09-25
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.