Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, I can't compile my code with SP20, but when I use the "read current metrics from device" with SP20 I get the following, with "not yet supported" for the visualization part Is it supposed to be like this ?
Last updated: 2024-04-24

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Update: it seems that the license is detected by CODESYS on my computer but not detected by the runtime on my device. I'm using Codesys control for raspberry pi in the latest version 4.11.0.0 Is there something to do to correct this ?
Last updated: 2024-04-29

Post by yannick on Raspberry PI 5 not working CODESYS Forge talk (Post)
Thanks for your quick help. It's working until I do a reboot of the raspberry PI. After that it goes back to 2024-04-20. How's that possible?
Last updated: 2024-04-29

Post by gseidel on Warning C0564 when compiling CNC project with variables program CODESYS Forge talk (Post)
Hi Fless, thanks for your report! We created an issue in our bug tracker (SM-5109) and will have a look at this issue. Best regards, Georg
Last updated: 2024-04-30

Post by k2saki on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment . CODESYS Forge talk (Post)
Hi Georg. Thank you so much ! Your advice is really helpful for me. I appreciate your great help.
Last updated: 2024-05-01

Post by ademarvribeiro on Upload program CODESYS Forge talk (Post)
Hello. in my experience, always click "Yes to all" to prevent error when go online. in this way, do you granted the infomation about hardware are the same, and dont lose " PLC configuration" for example.
Last updated: 2024-05-01

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Update: I found my error in the Scale function, where I used UINT_TO_REAL instead of DWORD_TO_REAL. I fixed it, errors unchanged.
Last updated: 2024-05-02

Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
Additionally the license is loaded on the soft storage for my device but it shows up as invalid. I just activated it today.
Last updated: 2024-05-02

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
It is either my installation is bad, or there is a bug. I re-created the project in 3.5 SP19 and there are no errors or warnings. Compiles with no errors or warnings. The original was done in 3.5 SP20. Thoughts?
Last updated: 2024-05-03

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06

Post by bschraud on Unerwünschte Username- und Passwortabfrage im Browserfenster CODESYS Forge talk (Post)
Leider habe ich keine Lösung für das Problem gefunden. Glücklicherweise konnte ich die "CODESYS Control for Raspberry Pi MC SL" wieder auf dem 32bit OS zum Laufen bringen.
Last updated: 2024-05-06

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
Ok yes now the loop has stopped when I set sum to zero before the for loop. Why will it retain the sum value from the last call?
Last updated: 2024-05-06

Post by alex-wall on Network Variables not updating CODESYS Forge talk (Post)
This worked for me. I had four identical PLC's. Three of them worked just fine with 255.255.255.255 as the broadcasting address but the 4th would not update the variables. Changed it to 192.168.x.255 and everything worked.
Last updated: 2024-05-07

Post by fugtwad on Automation Builder V2.5 EtherCAT CM579 Master Scan for devices - >No gateway selected CODESYS Forge talk (Post)
Scan from "IP-Configuration" with PC connected to first EtherCAT slave and "EtherCAT" tick box ticked gives slave info. As does ticking the "Emergency" tickbox.
Last updated: 2024-05-20

Post by paro on General question about library versions CODESYS Forge talk (Post)
I think you can use the newer versions. For a explanation from CODESYS, please read this post: https://www.codesys.com/the-system/versions-modularization.html
Last updated: 2024-05-29

Post by jaspergain on Non-existing identifiers CODESYS Forge talk (Post)
Hi, I'm using SP19 Patch 5, the software is also updated from SP18 Patch 5, I forgot to mention this. I will try a newer patch to see if it fixes the issue. Thanks for your help.
Last updated: 2024-05-30

Post by micik on "CAA" meaning in library names CODESYS Forge talk (Post)
Hello, what CAA stands for? Since it is a collection of different libraries, does it mean it is created by some specific organization? Thanks!
Last updated: 2024-05-31

Post by totorovic on IO-LINK Package - new license model CODESYS Forge talk (Post)
Thank you for your answer. Finally I don't confirm that it used to work before. It seems that the IO-link Package is needed is you want to configure the network, but you don't need it if you use generic IO-link devices.
Last updated: 2024-06-06

Post by eschwellinger on Licensing info not available (WAGO PFC200 + Codesys V3) CODESYS Forge talk (Post)
Seems that the Wago Target does not support the licensing. Either use PFC200 SL from CODESYS Store or ask the Wago support for help.
Last updated: 2024-06-10

Post by paulg on CODESYSControl_User.cfg - link to documentation? CODESYS Forge talk (Post)
Is there somewhere in the Codesys help files that generally details what configuration options are available for this file, and what details it logs regarding the configuration file? Or is that going to differ by libraries being used? Thanks!
Last updated: 2024-06-11

Post by brubingh on Download Missing Libraries not working CODESYS Forge talk (Post)
We are working on a project and the customer required 3.5.16 BF4. After working on the project for a few weeks I opened it the next morning and it could not access libraries. IecVarAccess could not be accessed. I checked if windows updated - it did not. So no explanation for why it lost access other than that I shut down the computer for the night. Note that I am using a demo license. I still haven't figured out any reason to purchase a license. So I spent the next hour reinstalling CodeSys. Note that I did NOT uninstall first. After install I waited another 5 minutes for it to open the first time. I clicked File->Open to open the project. Previously I had selected File->Recent Projects - not sure if that makes and difference. But after this process it did open the project and compile it just fine. This is miserable. If this had happened when I went on site to a customer I would have lost hours of work doing the reinstall. Is there a different and quicker fix?
Last updated: 2024-06-13

Post by fajean on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
https://us.store.codesys.com/codesys-control-for-raspberry-pi-sl.html Quoted from the "additional requirements" section : The operating system Raspberry Pi OS (32-bit)
Last updated: 2024-06-14

<< < 1 .. 98 99 100 101 102 .. 135 > >> (Page 100 of 135)

Showing results of 3375

Sort by relevance or date