I have an data structure which intend to list in a table and let user to add the content to the table. How can we able to support for displaying different language in the content of the table? which is dynamic to the user input.
Hi, I had accidentally created an multi core during the control RTE V3 installation (v3.5.17.30). How can I revert back from 2 cores to 1 core setup?
Hi, I am trying to run a batch file located in C:\ drive using the following function SysProcessCreate2(BatchFileName,i_FilePath,SysProcess_Createflag_interactive,pResult); The Batchfile is not able to run. Is there anything that I had missed out
Hi, I am running Control RTE in a PC and trying to connect a Server Program using TCP Client FB from the CAA Netbase service library (3.5.15). However it is not able to connect. Can the IP address set to be '127.0.0.1' (localhost)? I tried with the Control Win x64 and it works fine. My PC has 6 Ethernet ports and do I need to install all the Codesys Ethernet Driver to all the ports? Thanks Regards, Lai
I am using Control RTE with softmotion Dirve (Schneider LXM32 series Ethercat fieldbus). I need to use the Touchprobe FB but not sure how to fill 'Trigger_Ref'. I cannot find any document from schneider and hopefully can get some detail info from Codesys. What is 'iTriggerNumber' in the 'Trigger_Ref'? is it a Digital input number?
Hi, I am having the 3.5.16 runtime in PFC100. I am trying to save/read a file in the file structure but i can only access visu/ I tried to create a folder under the main directory but not able to read/write a file in that directory. Any idea?
Hi Edwin, I believe it got to do with the driver for the ethernet port. i had shutdown and power back and it is not able to install the driver anymore. I successfully update the driver, but it has '!' on the Codesys driver after cycle power. I will put this aside first as i had test with another PC and it all works fine. I may revert back my window OS to default and test again. Thank you for your support.
Hi Edwin, You may log in to the teamviewer anytime from now. Thanks
Hi Edwin, I had raised a ticket in 'My Question'. Hope to hear from you soon. Thanks
Hi Edwin, May I request a Teamviewer support? I had done all the trials and everything seems fine but i cannot browse and select the ethernet port.
Hi Edwin, After a long wait, I got the following as shown in the picture attached
Hi Edwin, On top of that, I cannot browse the ethernet card once i had connected to the soft PLC. Please refer to the picture attached.
Hi, after I run, there is an error on the Ethercat Master stated in the picture attached.
Hi Edwin, Thanks for the fast response. I am able to compile and login now. The control RTE can only access 'CmpEt1000Drv' right? After download and run, the Ethercat master is not able to communicate with my robot through the EL6695. I had tested with control win 3.5.16 x64 with Intel Ethercat driver (SysEthernet) and it is working. How should I proceed from here?
Hi, This is the attached project.
Hi, I had installed the new version of RTE 3.5.16 x64 and try to run the project attached. I had compiled the code without error but once login. The error happen. I will attach the project later.
Hi, I am using Control RTE. I would like to do a electronic caming function which only Softmotion library support the function. However, May I know the following? 1) If using Sercos III fieldbus, what are the PCI card supported? Does the pci card from Bosch support? who will provide the driver? 2) Does Bosch Sercos drive support softmotion profile? if yes, which model? where to get the device description file? 3) Does any Ethercat drive from Bosch support softmotion profile? Thanks
Hi, I am trying to implement CAM for 2 axis (walking beam mechanism). I saw the compatible list of drives that support softmotion but i did not see schneider LXM28E series in the list instead I am able to use schneider LXM32 series drive. Can I still achieve CAM function without softmotion axis? How to proceed if we still want to use the schneider LXM28 series? Thanks