  • Posted a comment on discussion Runtime 🇬🇧 on CODESYS Forge

    Hi, I am trying to run a batch file located in C:\ drive using the following function SysProcessCreate2(BatchFileName,i_FilePath,SysProcess_Createflag_interactive,pResult); The Batchfile is not able to run. Is there anything that I had missed out

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hi, I am running Control RTE in a PC and trying to connect a Server Program using TCP Client FB from the CAA Netbase service library (3.5.15). However it is not able to connect. Can the IP address set to be '127.0.0.1' (localhost)? I tried with the Control Win x64 and it works fine. My PC has 6 Ethernet ports and do I need to install all the Codesys Ethernet Driver to all the ports? Thanks Regards, Lai

  • Posted a comment on discussion Motion on CODESYS Forge

    I am using Control RTE with softmotion Dirve (Schneider LXM32 series Ethercat fieldbus). I need to use the Touchprobe FB but not sure how to fill 'Trigger_Ref'. I cannot find any document from schneider and hopefully can get some detail info from Codesys. What is 'iTriggerNumber' in the 'Trigger_Ref'? is it a Digital input number?

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hi, I am having the 3.5.16 runtime in PFC100. I am trying to save/read a file in the file structure but i can only access visu/ I tried to create a folder under the main directory but not able to read/write a file in that directory. Any idea?

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hi Edwin, I believe it got to do with the driver for the ethernet port. i had shutdown and power back and it is not able to install the driver anymore. I successfully update the driver, but it has '!' on the Codesys driver after cycle power. I will put this aside first as i had test with another PC and it all works fine. I may revert back my window OS to default and test again. Thank you for your support.

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hi Edwin, You may log in to the teamviewer anytime from now. Thanks

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hi Edwin, I had raised a ticket in 'My Question'. Hope to hear from you soon. Thanks

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hi Edwin, May I request a Teamviewer support? I had done all the trials and everything seems fine but i cannot browse and select the ethernet port.