Personal Data

Username:
lorenzop
Joined:
2021-07-01 09:31:40

Projects

  • No projects to display.

User Activity

  • Modified a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello there, today i'm having problem about the communication between HMI (Weintek, protocol CODESYS V3 Ethernet) and Raspberry pi At the power up everything is fine and communication work properly, then when I perform a download of the panel project it seems like the port (or the protocol) remains busy and the communication does not work. if I stop and restart runtime on Raspberry the communication doesn't restore. If I delete application on RasPi and download again communication doesn't restore....

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello there, today i'm having problem about the communication between HMI (Weintek, protocol CODESYS V3 Ethernet) and Raspberry pi At the power up everything is fine and communication work properly, then when I perform a download of the panel project it seems like the port (or the protocol) remains busy and the communication does not work. if I stop and restart runtime on Raspberry the communication doesn't restore. If I delete application on RasPi and download again communication doesn't restore....

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Yes yes, I can do the communication between HMI panel and PLC, even the import of symbols, what I was asking is something else. I have an external management system of a customer in his PC who, in order to satisfy the 4.0 requirements, must read from my PLC a GVL block and write some recipes on a GVL block. On siemens I can easily make these data available and in profinet I come to take them with the management system, on codesys instead I don't know how to make them available not having available...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Ciao Gatto, utilizzo una Raspberry della Elsist come PLC e un pannello Weintek MT8092XE, tra loro due comunicano in Ethernet. Il gestionale deve ancora essere fatto ma si pensava ad una comunicazione Modbus TCP/IP oppure Profinet. Ti ringrazio per avermi risposto e spero che si riesca a trovare la soluzione. Buona giornata

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello there, I have to send my variables that are in a GVL block to an external management system. These variables must be able to be written, same with another group of GVLs that must be read I give an example with TIA PORTAL from siemens On TIA PORTAL I can go to the properties of a DB, uncheck the compressed variables and the various offsets of the variables appear. I communicate the slot and rack data and my job is done, the owner of the management software is able to communicate and take variables...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello there, I have to send my variables that are in a GVL block to an external management system. These variables must be able to be written, same with another group of GVLs that must be read I give an example with TIA PORTAL from siemens On TIA PORTAL I can go to the properties of a DB, uncheck the compressed variables and the various offsets of the variables appear. I communicate the slot and rack data and my job is done, the owner of the management software is able to communicate and take variables...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I'm 3.5 SP17, i think i have profinet package because I use Siemens g120c inverters in profinet, but if i miss this package how i recover it?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    It gives me this error

View All