  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Yes yes, I can do the communication between HMI panel and PLC, even the import of symbols, what I was asking is something else. I have an external management system of a customer in his PC who, in order to satisfy the 4.0 requirements, must read from my PLC a GVL block and write some recipes on a GVL block. On siemens I can easily make these data available and in profinet I come to take them with the management system, on codesys instead I don't know how to make them available not having available...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Ciao Gatto, utilizzo una Raspberry della Elsist come PLC e un pannello Weintek MT8092XE, tra loro due comunicano in Ethernet. Il gestionale deve ancora essere fatto ma si pensava ad una comunicazione Modbus TCP/IP oppure Profinet. Ti ringrazio per avermi risposto e spero che si riesca a trovare la soluzione. Buona giornata

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello there, I have to send my variables that are in a GVL block to an external management system. These variables must be able to be written, same with another group of GVLs that must be read I give an example with TIA PORTAL from siemens On TIA PORTAL I can go to the properties of a DB, uncheck the compressed variables and the various offsets of the variables appear. I communicate the slot and rack data and my job is done, the owner of the management software is able to communicate and take variables...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hello there, I have to send my variables that are in a GVL block to an external management system. These variables must be able to be written, same with another group of GVLs that must be read I give an example with TIA PORTAL from siemens On TIA PORTAL I can go to the properties of a DB, uncheck the compressed variables and the various offsets of the variables appear. I communicate the slot and rack data and my job is done, the owner of the management software is able to communicate and take variables...

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I'm 3.5 SP17, i think i have profinet package because I use Siemens g120c inverters in profinet, but if i miss this package how i recover it?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    It gives me this error

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I have to import this GSDML file into my project. How can I do it? I'll attach it down here if yuo have to try. Let me know the procedure. Thanks

  • Posted a comment on discussion Forge πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I have to import this GSDML file into my project. How can I do it? I'll attach it down here if yuo have to try. Let me know the procedure. Thanks